• Title/Summary/Keyword: 일반촬영검사

Search Result 163, Processing Time 0.02 seconds

Exposure Dose of Thyroid, Breast, and Sexual Gland using a Personal Dosimeter in Multiple CT Examinations (다중 CT 검사 시 개인선량계를 이용한 갑상선, 유방, 생식선의 피폭선량)

  • Kim, Hae-Suk;Kim, Jang-Oh;Lee, Yoon-Ji;Heo, Sung-Hoe;Lee, Chang-Ho;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.345-351
    • /
    • 2020
  • In this study, a dose assessment was conducted on the exposure dose of thyroid, breast and sexual gland using a personal dosimeter in multiple CT examinations currently being conducted in health examinations. The dose assessment was measured by attaching TLD and EPD to the locations of the thyroid, breast and sexual gland during CT examinations of Brain, Brain + C-S, Brain + Low lung, Brain + L-S among CT items. The generated dose of equipment, CTDIvol and DLP, was measured. The study found that effective doses were rated 41.7% higher for thyroid TLD in Brain + C-S CT examinations than for the general public, 156% higher for EPD, 10% for breast EPD in Brain + Low Lung CT examinations, 124.4% higher for reproductive TLD and 339.8% higher for Brain + L-S CT examinations. The CTDIvol and DLP analysis results showed that C-S CTDIvol values were higher than the diagnostic reference levels at 0.6%, Low Lung CTDIvol values at 5.7%, DLP values at 11.8% and L-S CTDIvol values at 1.2%. In order to reduce the exposure dose of patients, indiscriminate examination is reduced and dose limit setting is needed in health examination.

Evaluation of Breast Dose in Mammography for Breast Implant Patient using a Monte Carlo Simulation (몬테칼로 모의모사를 이용한 유방성형술 환자의 유방선량평가)

  • Kim, Ji-Soo;Cho, Yong-In;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.253-259
    • /
    • 2020
  • Mammography has the advantage of being economical, simple and effective in detecting microcalcification, but breast is a highly sensitive organ and is accompanied by the risk of an over-exposure. While accurate dose assessments are important to prevent this, current breast dose assessments are limited to breast implant patients. This purpose of this study was to identify dose variations due to tube voltages by forming a mock-up with breast implants for an accurate dosimetric assessment on breast implant patients. As a result, doses from the presence of breast implants were smaller than those from the absence of the mammal. As the result of the change of the voltage to 26, 28, 30, and 32 kV, the imcreased tube voltage included larger dose regardless of the presence of Breast implant. Therefore, it is believed that diagnosis recommendations for breast implants will be possible if further studies on internal and external bioretical imaging and quality assessment are carried out as the basis for this study.

The Estimation of the Target Position and Size Using Multi-layer Neural Network in Electrical Impedance Tomography (전기 임피던스 단층촬영법에서 다층 신경회로망을 이용한 표적의 위치와 크기 추정)

  • Kim, Ji-Hoon;Kim, Chan-Yong;Cho, Tae-Hyun;Lee, In-Soo
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.35-41
    • /
    • 2018
  • Electrical impedance tomography (EIT) is a kind of nondestructive testing technique that obtains the internal resistivity distribution from the voltages measured at the electrodes located outside the area of interest. However, an image reconstruction problem in EIT has innate non-linearity and ill-posedness, so that it is difficult to obtain satisfactory reconstructed results. In general, a neural network can efficiently model the input and output relationships of a non-linear system. This paper proposes a method for estimating the position and size of a circular target using a multi-layer neural network. To verify the performance of the proposed method, neural network was trained and various computer simulations were performed and satisfactory performance was verified.

Evaluation of Approximate Exposure to Low-dose Ionizing Radiation from Medical Images using a Computed Radiography (CR) System (전산화 방사선촬영(CR) 시스템을 이용한 근사적 의료 피폭 선량 평가)

  • Yu, Minsun;Lee, Jaeseung;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.455-464
    • /
    • 2012
  • This study suggested evaluation of approximately exposure to low-dose ionization radiation from medical images using a computed radiography (CR) system in standard X-ray examination and experimental model can compare diagnostic reference level (DRL) will suggest on optimization condition of guard about medical radiation of low dose space. Entrance surface dose (ESD) cross-measuring by standard dosimeter and optically stimulated luminescence dosimeters (OSLDs) in experiment condition about tube voltage and current of X-ray generator. Also, Hounsfield unit (HU) scale measured about each experiment condition in CR system and after character relationship table and graph tabulate about ESD and HU scale, approximately radiation dose about head, neck, thoracic, abdomen, and pelvis draw a measurement. In result measuring head, neck, thoracic, abdomen, and pelvis, average of ESD is 2.10, 2.01, 1.13, 2.97, and 1.95 mGy, respectively. HU scale is $3,276{\pm}3.72$, $3,217{\pm}2.93$, $2,768{\pm}3.13$, $3,782{\pm}5.19$, and $2,318{\pm}4.64$, respectively, in CR image. At this moment, using characteristic relationship table and graph, ESD measured approximately 2.16, 2.06, 1.19, 3.05, and 2.07 mGy, respectively. Average error of measuring value and ESD measured approximately smaller than 3%, this have credibility cover all the bases radiology area of measurement 5%. In its final analysis, this study suggest new experimental model approximately can assess radiation dose of patient in standard X-ray examination and can apply to CR examination, digital radiography and even film-cassette system.

A Base Study on the Constancy Quality Control Test and Clause of Diagnosis Radiation Equipment (진단용 방사선 발생장치의 수시 정도관리 항목 및 기준에 관한 기초 연구)

  • Heo, Yeji;Kim, Kyotae;Noh, Sicheul;Nam, Sanghee;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.3
    • /
    • pp.105-110
    • /
    • 2014
  • Diagnostic radiation equipment diagnosis and treatment of disease of recent plays a central role, but this is based on the assumption of an appropriate balance of benefits and risks of diagnostic. If balance is not maintained has the potential to give an adverse effect on the health of the public. In the case of an overseas, the importance of (QA) quality assurance of medical equipment is growing, but evaluation criteria of quality assurance has not been clearly presented in domestic. Therefore, the modernization of medical equipment from the point at which the degree of cycle-by-cycle management system of foreign national to be suitable for diagnostic radiation generator entry and quality control standards by introducing a tailoring is necessary. In this study the most frequently used diagnostic radiation generator X-ray imaging apparatus of the general three-year periodic inspections at any time between the periodic inspection items and quality control methods and standards for the establishment of the United States, Canada and abroad, and international electronic literature search Technical Committee (International Electro-technical Commission, IEC) were compared with the provisions of item. Based on the national quality control items when opening frequent inspection items and standards presented as a basis for setting up study.

ERUPTION DISTURBANCE ASSOCIATED WITH A SMALL ODONTOMA (작은 치아종으로 인한 맹출 장애)

  • Song, Ji-Hyun;Lee, Kwang-Hee;Ra, Ji-Young;Lee, Dong-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.490-497
    • /
    • 2007
  • Odontoma is defined as a benign odontogenic tumor containing enamel, dentin as well as cementum and constitued 22% of all odontogenic tumors. Although the lesions are commonly asymptomatic, they may be discovered routine radiographic examination. Odontomas often cause disturbances in the eruption of teeth such as, impaction or delayed eruption, retention of primary teeth, or abnomalities in the position of the teeth such as tipping or displacement of adjacent teeth. Radiologically, odontomas manifest as a dense radiopaque lesion surrounded by a thin radiotransparent halo. However, in some cases, radiopacity was not quite clear and images of the teeth shadowed very tiny odontomas. And at early development stages of odontoma, calcification remains immature and is difficult to diagnose on radiographs. This suggests that when delayed eruption of the teeth is found, periapical radiographs should be taken to clarify whether any small area of radiopaque material exists. This case report shows tiny odontomas involving an impacted tooth and crowding and we remove the tiny odontoma surgically.

  • PDF

A Clinical Review of Acute Respiratory Distress Syndrome (ARDS) Due to Miliary Tuberculosis (급성호흡곤란증후군으로 발현된 속립성 결핵의 임상적 고찰)

  • Ahn, Young-Soo;Lee, Sang-Moo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.1
    • /
    • pp.17-26
    • /
    • 2002
  • Background : The detection and early elimination of the causes for acute respiratory distress syndrome(ARDS) at the initial stage can result in a more favorable prognosis. Miliary tuberculosis as a cause of the ARDS is quite rare. A diagnosis of miliary tuberculosis is difficult due to the diversity of radiological patterns and non-specific clinical finfings, and low sensitivity of sputum examinations for acid-fast bacilli(AFBs). An analysis of the clinical data is the first step in diagnosing these unusual, rare cases. Materials and Methods : In this study the clinical features, laboratory data, radiological findings and diagnostic methods were analyzed in 9 cases with an initial presentation of ARDS due to miliary tuberculosis. The ARDS was defined by the definition of the American-Europian consensus conference 1992. Results : The mean age of the patients was $67{\pm}18$ years (F:M=7:2). The chief complaints were dyspnea(5/9), coughing (3/9) and fever(5/9). On a physical examination, fine or coarse crackles were noted(6/9). The ARDS developed on average 6.7 days after the initial respiratory symptoms. The mean $PaO_2/FiO_2$ of the patients was $133.5{\pm}53.4$, the number of cases with a WBC<5000/$mm^3$ was 4 out of 9 cases. A platelet count<70,000/$mm^3$ was observed in 2 out of 9 cases, and the serum albumin level was $2.6{\pm}0.6$ g/dL. The initial simple chest PA showed ground glass appearances and consolidation in all cases, However, the miliary nodular densities were observed in only 4 out of the 9 cases. HRCT revealed alveolar densities and a consolidation in 5 out of 6 cases, and miliary nodules in 5 out of 6 cases, The diagnosis of tuberculosis was made by a liver biopsy (4/4, 100% sensitivity), a bone marrow biopsy (1/2, 50% sensitivity), and an open lung biopsy (1/1), the sputum AFB was positive in only 2 out of 9 cases. The patient was treated with INH, RFP, EMB, PZA, and steroids. The survival rate was 55.5%. Conclusion : Miliary tuberculosis should be considered as one of the causes for ARDS in areas where there is a high prevalence of tuberculosis. The chief complaints of the patients on admission are dyspnea, fever and coughing without any specific riskfactors. A liver biopsy is particularly useful in ARDS patients with mechanical ventilation to determine the causes of the ARDS if miliary tuberculosis is suspected as being the underlying disease.

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF

Surface Reconstruction Using CORONA KH-4 Imagery (CORONA KH-4 영상을 이용한 3차원 지형정보 취득)

  • Sohn, Hong-Gyoo;Yeu, Bock-Mo;Kim, Gi-Hong;Choi, Jong-Hyun
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2002.03a
    • /
    • pp.145-149
    • /
    • 2002
  • CORONA는 미국이 1960년에서 1972년까지 냉전시대 관심지역에 대한 첩보영상을 취득하기 위하여 운영한 영상취득시스템으로 1995년 일반에 자료가 공개됨에 따라 과거의 고해상도 영상자료를 이용할 수 있는 길이 열리게 되었다. 그러나 현재까지 CORONA 영상처리를 위한 모듈을 제공하는 원격탐측 소프트웨어가 개발되어 있지 않기 때문에 CORONA 영상을 이용하여 수치표고모형이나 정사영상을 제작하기 위해서는 적절한 모델링 방법이 필요하다. CORONA 영상은 파노라마 영상으로 필름 가장자리로 갈수록 왜곡이 많이 생기며 사진기 지표가 없고 위성의 궤도와 위치, 자세, 속도, IMC(Image Motion Compensation)에 대한 자세한 자료를 제공하지 않는 문제점이 있다. 따라서 본 논문에서는 지형복원을 위하여 지상기준점을 이용하는 2가지 모델링 방법을 이용하였다. 첫 번째는 파노라마 왜곡과 촬영 비행체 이동에 의한 왜곡, IMC에 의한 왜곡을 보정하는 모형식을 구성하여 이용하였으며, 두 번째는 위성과 센서에 대한 정보를 필요로 하지 않는 다항식비례모형(RFM; Rational Function Model)을 이용하였다. 대상지역은 서울지역의 입체영상으로 대략 $33km{\times}26km$ 지역이다. 영상은 지상해상도 약 2.7m로 스캐닝하였고 1:1000 수치지도를 통해 20개의 기준점과 36개의 검사점을 관측하였다. 검사점의 위치정확도를 평가해 본 결과 첫 번째 방법은 수평방향으로 평균 3.9m(X), 2.8m(Y)의 오차를 보였으며 표고의 경우 4.2m의 오차를 보여주었다. 두 번째 방법은 수평방향으로 평균 3.2m(X), 2.8m(Y)의 오차를 보였으며 표고의 경우 5.5m의 오차를 보여주었다. 지형복원 정확도를 검증하기 위하여 첫 번째 방법을 이용하여 대상지역 중 일부인 서울 남산지역에 대해 정사영상과 10m간격의 DEM을 제작하였으며 1:1000 수치지도를 통해 제작된 DEM과 비교한 결과 총 43990개 격자점의 표고 차이는 평균 5.98m였다.

  • PDF

Mediastinal Teratoma: A Pictorial Essay (종격동 기형종: 임상 화보)

  • Sang Gyun Kim;Won Gi Jeong;Sang Yun Song;Taebum Lee;Jong Eun Lee;Hye Mi Park;Yun-Hyeon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.597-607
    • /
    • 2022
  • The mediastinum is the most prevalent site of extragonadal teratomas. Patients with mediastinal mature teratomas are usually young adults, and the condition does not show significant sexual differences. Mediastinal teratomas are mostly located in the anterior mediastinum. Patients are usually asymptomatic, although they can have several complications when the teratomas become large or rupture. Most mediastinal teratomas can be diagnosed using CT. Diagnosing ruptured or malignant teratomas is challenging because of their atypical clinical and radiological presentations. In this article, we describe various manifestations of mediastinal teratomas, with an emphasis on radiologic features.