• Title/Summary/Keyword: 일반강도 콘크리트

Search Result 645, Processing Time 0.028 seconds

Seismic Response of Exterior Beam-Column Subassemblies Using Normal and High-Strength Materials (일반강도 및 고강도 재료를 사용한 보-기둥 접합부의 지진응답)

  • 장극관;서대원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.4
    • /
    • pp.83-94
    • /
    • 1999
  • High-strength concrete has demonstrated characteristics of both increased strength and enhanced durability; hence its use has become more and more widespread. But, due to the lack of experimental evidance on the seismic performance of frame members constructed with high-strength concrete, the current codes of their design provisions are based on normal concrete test. The purpose of this study is to compare the response of the high-strength concrete beam-column-slab subassemblies with the response of a normal-strength concrete specimens. Four assemblies $(f_c'=240kg/\textrm{cm}^2, f_c'=700kg/\textrm{cm}^2)$ with 2/3 scale were designed and tested to investigate seismic behavior.

  • PDF

Absorption and Strength Properties of Landscape Paving Concrete According to Zeolite Coarse Aggregate Replacement Rate (제올라이트 굵은골재 대체율에 따른 조경포장 콘크리트의 흡수 및 강도 특성)

  • Na, Ok-Pin;Lee, Gi-Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.131-139
    • /
    • 2021
  • This study assessed the use of zeolite with high absorption performance in landscape paving concrete as a substitute for aggregate. The absorption performance and strength properties of paving concrete were investigated according to the replacement rate of the zeolite coarse aggregate, and the mechanical properties were investigated through strength tests. The absorption rate of the zeolite aggregate was 14%, which is 2.5 times higher than that of general aggregate. When zeolite coarse aggregate is applied to paving concrete, the absorption rate increases according to the replacement rate. The absorption rate was 5.2% at a replacement rate of 50%, which was 42% higher than that of general paving concrete. The compressive strength increased to 20% of the replacement rate and decreased at a higher replacement, but all the strengths in the construction standard code were satisfied. The flexural strength satisfied the code up to a replacement rate of 10%, but the strength decreased with increasing replacement rate, and the splitting tensile strength was greater than that of paving concrete using general aggregate up to a 20% replacement rate. Overall, zeolite coarse aggregate can be applied as a substitute.

A Proposal of New Model for Stress-Strain Relationship and Stress Distribution of Ultra High-Strength Concrete (초고강도 콘크리트에 적합한 응력-변형율 모델과 응력분포 모델의 제안)

  • 장일영;박훈규
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.197-206
    • /
    • 1997
  • 본 연구에서는 기존의 초고강도 콘크리트에 대한 실험자료를 근거로 합리적인 통계적 기법을 이용하여 초고강도 콘크리트의 설계 실용화를 위한 응력-변형율 관계 모델과 응력분포 모델을 제안하는 것이 목적이다. 이를 위하여 첫째, 콘크리트의 응력-변형율 특성을 결정하는 재료 변수들(탄성계수, 최대 압축강도시 변형율 등)에 대한 검토를 수행하였다. 둘째, 이를 바탕으로 일반성과 정확성을 동시에 갖춘 초고강도 콘크리트(700~1400kg/$\textrm{cm}^2$)에 적합한 응력-변형율 모델을 제안, 비교, 고찰하엿다. 셋째, 제안된 응력-형율 모델로부터 초고강도 콘크리트 구조의 극한강도를 평가하기에 적합한 응력분포모델을 제안, 일반성과 정확성을 비교 검증하였다.

500kg/cm$^2$고강도 콘크리트 - 재료특성$\cdot$현장시공성에 관한 연구

  • 안재현;권영호
    • 어항어장
    • /
    • s.18
    • /
    • pp.69-77
    • /
    • 1992
  • 고강도 콘크리트의 실용화 일환으로 설계기준강도 500kg/cm$^2$ 이상인 고강도 콘크리트의 현장 B/P 생산과 실대구조물의 시공성 및 강도, 온도 특성에 관한 연구를 수행하였다. 이러한 연구를 위해 현장 최적배합비 선정과 레미콘 운반시간에 따른 경시변화 시험을 수행하였고 실대구조물의 코아강도 및 콘크리트 내부온도를 측정하였다. 일반 현장재료와 장비의 사용으로도 고강도 콘크리트의 생산과 시공성을 확보할 수 있었으며 실대구조물의 코아강도가 500kg/cm$^2$ 이상을 나타냄으로써 고강도 콘크리트의 실용화에 대한 가능성을 확인할 수 있었다.

  • PDF

Freezing-and-Thawing Resistance and Strain Characteristics of Recycled Concrete (재생콘크리트의 동결융해저항성과 변형특성)

  • 김광우;이봉학;도영수
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.4
    • /
    • pp.115-122
    • /
    • 1992
  • 폐쇄 폐콘크리트를 재활용한 재생콘크리트의 강도특성을 천연골재를 사용한 일반콘크리트와 비교하였다. 동결융해 처리수의 압축강도와 3점휨 재하시험하의 변형율을 측정하였다. 재생콘크리트는 동결융해 처리 후 압축강도 보존율이 더 높았다. 재생콘크리트는 또한 높은 변형율과 처짐에 민감함을 보였으나 파괴와 관련된 다른 성질들은 일반콘크리트와 유사하거나 더 좋은 것으로 나타났다. 그러므로 폐콘크리트를 구조용 콘크리트 제조에 재 사용이 가능할 것으로 보여진다. 그러나 실제 사용을 위하여는 콘크리트에 있어서 중요한 성질인 압축강도가 더 증진되어야 하며 최대 변형율도 보다 자세히 점검되어야 한다.

Improving Performance of Recycled Waste Concrete (재생 폐콘크리트의 성능향상에 관한 연구)

  • 이봉학;김광우;박제선;김진영
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.2
    • /
    • pp.136-145
    • /
    • 1995
  • A method for lmprovlng strengths of recycled concrete was studied to make use of it in nolmal concrete structures. Recycled conc~ete was prepared by replacing 50% by weight of coarse aggregate with recycled aggregate. Mix design rnet hod for crushed aggregates was used and specirriens were cured by normal moisture curing method. A plastlciser and a fly ash were added to the mix to improve performance of recycled concrete. Compressive strength, flexural strength, tensile strength, elastic modulus, stress-strain relationship, long-term compressive strength and fracture toughness were evaluated and compared with those of rlormal concretes. Recycled concrete showed, in general, lower compressive strength than normal concreks. It also showed lower elastic modulus, lower tensile and flexural strengths, and higher strain under the same stress level. However, by reducing w /c ratio down to 35% using the plasticiser. average compressive strength(${\alpha}_{28}$) of recycled concrete was reached. with slump of $16{\pm}2$cm, to $225kg/cm^2$ or hlgher, which is an acceptable strmgth level for normal structural concrete. I-Iowevei., elastic modulus and strain should be improved further for practical use of recycled concrctc: in normal structure. Fly ash addition in both concretes showed an effect of irnprovilig long term compressive strength and reducing strengths.

Analysis of a Behavior of Shear Stud in Steel-concrete Composite Beam using High-rise Building (초고층 건물에 적합한 합성보에서 전단스터드의 거동에 관한 비교 분석 연구)

  • Shim, Hak-Bo;Jang, Sung-Hoon;Park, Soon-Joen;Lee, Joo-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.34.2-34.2
    • /
    • 2010
  • 건물이 초고층화됨에 따라 고강도 콘크리트를 구조물에 적용하고 있으며 내화 시 폭열 예방을 위해서 고강도 콘크리트에 섬유를 첨가하는 경우도 있다. 초고층 구조물 합성부재에서 강재보와 콘크리트 슬래브의 합성작용을 위해서는 전단스터드를 필요로 하게 된다. 오늘날 제시된 전단스터드 설계식은 일반강도 콘크리트 실험에 의해 제시되었고 전단스터드는 항복강도에만 제한되는 것으로 나타났다. 따라서 본 논문은 초고층 건물에 적합한 고강도콘크리트를 기존 제안식으로 비교 분석하고 새로운 설계식의 필요성을 확인하며 ANSYS 모델링을 통한 전단스터드의 거동을 분석하는데 그 목적이 있다.

  • PDF

A Study on the Strength Properties and the Temperature Curve of Winter Concrete According to the Difference of Curing Method in Mock-up Test (실물부재시험에서의 양생방법 차이에 따른 한중콘크리트외 온도이력 및 강도특성에 관한 연구)

  • Kim, Young-Jin;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.541-548
    • /
    • 2003
  • This study is to investigate the temperature curve and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of reducing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluation in-place concrete strength.

The Shrinkage Characteristics of Concrete in Using Oxidized Electric-Furnace Slag Aggregate (전기로산화슬래그 골재를 사용한 콘크리트의 수축 특성)

  • Sohn, Yu-Shin;Park, Chan-Gyu;Lee, Seung-Hoon;Choi, Sung-Woo;Ryu, Deug-Hyun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.253-254
    • /
    • 2010
  • This study is about evaluation of shrinkage of concrete used oxidized EFS(electric-furnaceslag) aggregate. As a result, the shrinkage of concrete used oxidized EFS aggregate is decreased to about 40% in proportion to replacement of oxidized EFS aggregate in total aggregate volume.

  • PDF

Theoretical Assessment of Reinforced Steel Fibrous Concrete Beam Equivalent to Conventional RC Beam (일반 RC보와 동등한 강섬유 보강 철근콘크리트 보의 이론적 산정)

  • 이차돈;윤여천
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.1
    • /
    • pp.195-206
    • /
    • 1997
  • 비선형 layered 유한요소법과 비선형 프로그래밍 기법에 의하여 주어진 기존의 철근콘크리트 보의 휨강도 및 연성을 근사하게 나타낼 수 있는 강섬유고강 철근콘크리트 보(Reinforced Steel Fibrous Concrete Beam : RSFC Beam)의 인장 및 압축철근량, 강섬유의 혼입률 등을 산정하였다. 개발된 모델을 이용하여 콘트리트의 압축강도 및 철근비가 서로 다른 일반 철근콘크리트 보에 있어서 강섬유보강 콘크리트를 사용할 경우, 기존 철근을대체하는 강섬유의 량과 또한 이로 인한 인장 \ulcorner 압축 철근량의 변화량을 조사하였다. 기존 문헌에 나타난 강섬유보강 콘크리트보의 전간강도식을 이용하여 일반 철근콘크리트보와 비교하여 강섬유보강 철근콘크리트 보에서 증가될 수 있는 스터럽의 간격을 산정하였다.