• Title/Summary/Keyword: 인체영향

Search Result 1,817, Processing Time 0.035 seconds

Effects of Self-Made Bismuth Shield Installation on Entrance surface Dose Reduction during Endovascular Treatment of Cerebral Aneurysms (뇌동맥류 코일 색전술시 자체 제작한 Bismuth 차폐체 설치의 피부선량 감소 효과)

  • Kim, Jae-Seok;Kim, Young-Kil;Choi, Jae-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.175-183
    • /
    • 2019
  • Cerebral nervous system intervention has been reported frequently due to radiation exposure such as blistering of the skin, hair loss, and erythema due to prolonged procedures. By applying ergonomically manufactured Bismuth (atomic number 83; Bi) shield to endovascular treatment of cerebral aneurysms, we aimed to minimize radiation exposure of scalp and lens from medical radiation exposure. The measurement site was the posterior part of the head, bilateral temporal part, bilateral quadriceps part, nose part, and the measuring part was attached to the optically stimulated Luminescence dosimeter (OSLD) Before and after the use, the entrance surface dose was compared and analyzed. The average entrance surface dose of group A (unshield) was 92.44 mGy, and group B was measured at 67.55 mGy. The average decrease in Group B was 26.92% compared to Group A. The entrance surface dose mean of the occipital region was measured at 146.08 mGy B group at 103.23 mGy and decreased by an average of 29.32% in group B compared to group A. The average entrance surface dose of the bilateral temporal part was measured in group A at 101.90 mGy group B at 72.69 mGy and decreased by an average of 28.67% in group B compared to group A. The average entrance surface dose for bilateral quadriceps part was measured at 27.51 mGy group B at 21.39 mGy and averaged 22.26% less in group B than group A. It is believed that the use of bismuth shields will be an alternative to reducing radiation disturbance due to temporary hair loss and other stochastic effects that may occur after the endovascular treatment of cerebral aneurysms procedure.

Anti-inflammatory Effect of Heat-Killed Enterococcus faecalis, EF-2001 (열처리 사균체 엔테로코커스 패칼리스 EF-2001의 항염증 효과)

  • Choi, Moon-Suk;Chang, Sang-Jin;Chae, Yuri;Lee, Myung-Hun;Kim, Wan-Joong;Iwasa, Masahiro;Han, Kwon-Il;Kim, Wan-Jae;Kim, Tack-Joong
    • Journal of Life Science
    • /
    • v.28 no.11
    • /
    • pp.1361-1368
    • /
    • 2018
  • Inflammation is the most common condition in the human body. Tissue damage triggers inflammation, together with vasodilation and increased blood flow at the inflamed site, resulting in edema. Inflammatory responses are also triggered by lipopolysaccharide (LPS), a Toll-like receptor Enterococcus faecalis, a gram-positive organism, has been reported to possess immunomodulatory and preventive activities; however, its use may present risks of sepsis and other systemic infections. Heat-killed Enterococcus faecalis (EF-2001) has been reported to induce antitumor activity, but its effects on inflammation are not known. In the present study, we investigated the effect of EF-2001 on LPS-induced macrophage inflammatory responses. EF-2001 treatment reduced nitric oxide (NO) production, indicating suppression of inflammatory reactions. EF-2001 showed no cytotoxicity in macrophages. Further investigation of the anti-inflammatory mechanism of EF-2001 indicated that EF-2001 reduced the LPS-induced expression of inducible nitric oxide synthase and cyclooxygenase-2. EF-2001 also reduced f the LPS induction of several inflammatory molecules involved in the nuclear factor-${\kappa}B$ ($NF-{\kappa}B$) and mitogen-activated protein kinase pathways, including ERK, JNK, and p38 phosphorylation, in a concentration-dependent manner. Additionally, EF-2001 inhibited Akt phosphorylation and increased the expression of the inhibitory ${\kappa}B$ ($I{\kappa}B$) protein, an inhibitor of $NF-{\kappa}B$. EF-2001 also inhibited the nuclear translocation of p65. These results suggest that EF-2001 has anti-inflammatory properties and may be useful for treating inflammatory diseases.

Monitoring of residual pesticides in fresh-cut produce in Gangseo, Seoul (서울 강서지역 신선편이식품 원재료 농산물의 잔류농약 모니터링)

  • Kim, Chang-Kyu;Oh, Se-A;Choi, Seong-Seon;Kim, Jeong-Gon;Lee, Jae-Kyu;Kim, Dong-Kyu;Jung, Bo-Kyung;Yuk, Dong-Hyun;Yun, Eun-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.218-223
    • /
    • 2022
  • This study, conducted during 2018-2021 in Gangseo, Seoul, monitored residual pesticides in 14 types of fresh-cut produce, including lettuce, tomato, and celery, in wholesale market and supermarkets. A total of 589 cases (2.9%) were inspected; 17 cases (2.9%) were detected within the criteria, and 2 cases (0.3%) exceeded the maximum residual limit (MRL). When assessing the distribution stage of the pesticide violation, there were two violations in the wholesale market (before distribution), which differed from the supermarkets (during distribution). The detected pesticides, mainly insecticides and fungicides, appeared in the order of flubendiamide, flufenoxuron, and diazinon. A violation rate of 0.3% was found for wholesale market, which is collection area dedicated to fresh-cut produce, and this was lower than that for general agricultural products (1.4-2.5%). Since fresh-cut produce are consumed immediately after simple processing, residual pesticides significantly affect the human body; therefore, continuous monitoring of pesticide residues is required.

Phosphate Concentration Dependent Degradation of Biofilm in S. aureus Triggered by Physical Properties (인산염 농도에 따른 물성 변화로 발생하는 황색포도상구균 바이오필름 제거 현상)

  • Song, Sang-Hun;Hwang, Byung Woo;Son, Seong Kil;Kang, Nae-Gyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.47 no.4
    • /
    • pp.361-368
    • /
    • 2021
  • The objective of this study was to establish technology for removing bacteria with human- and eco-friendly material. Staphylococcus aureus as an important component for balanced equilibrium among microbiomes, was cultured under various concentrations of phosphate. Experimental observation relating to physical properties was performed in an addition of phosphate buffer. Statistically minimum value of size and hardness using atomic force microscope was observed on the matured biofilm at 5 mM concentration of phosphate. As a result of absorbance for the biofilm tagged with dye, concentration of biofilm was reduced with phophate, too. To identify whether this reduction by phosphate at the 5 mM is caused by counter ion or not, sodium chloride was treated to the biofilm under the same condition. To elucidate components of the biofilm counting analysis of the biofilm using time-of-flight secondary ion mass spectrometry was employed. The secondary ions from the biofilm revealed that alteration of physical properties is consistent to the change of extracellular polymeric substrate (EPS) for the biofilm. Viscoelastic characterization of the biofilm using a controlled shear stress rheometer, where internal change of physical properties could be detected, exhibited a static viscosity and a reduction of elastic modulus at the 5 mM concentration of phosphate. Accordingly, bacteria at the 5 mM concentration of phosphate are attributed to removing the EPS through a reduction of elastic modulus for bacteria. We suggest that the reduction of concentration of biofilm induces dispersion which assists to easily spread its dormitory. In conclusion, it is elucidated that an addition of phosphate causes removal of EPS, and that causes a function of antibiotic.

Development of Potassium Impregnated Carbon Absorbents for Indoor CO2 Adsorption (K계열 함침 탄소계 흡착제의 실내 저농도 이산화탄소 흡착성능 강화)

  • Jeong, Se-Eun;Wang, Shuang;Lee, Yu-Ri;Won, Yooseob;Kim, Jae-Young;Jang, Jae Jun;Kim, Hana;Jo, Sung-ho;Park, Young Cheol;Nam, Hyungseok
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.606-612
    • /
    • 2022
  • Relatively high indoor CO2 concentration (>1,000 ppm) has a negative impact on human health. In this work, indoor CO2 adsorbent was developed by impregnating KOH or K2CO3 on commercial activated carbon, named as KOH/AC and K2CO3/AC. Commercial activated carbon (AC) showed relatively high BET surface area (929 m2/g) whereas KOH/AC and K2CO3/AC presented lower BET surface area of 13.6 m2/g and 289 m2/g. Two experimental methods of TGA (2,000 ppmCO2, weight basis) and chamber test (initial concentration: 2,000 ppmCO2, CO2 IR analyzer) were used to investigate the adsorption capacity. KOH/AC and K2CO3/AC exhibited similar adsorption capacities (145~150 mgCO2/g), higher than K2CO3/Al+Si supports adsorbent (84.1 mgCO2/gsample). Similarly, chamber test also showed similar trend. Both KOH/AC and K2CO3/AC represented higher adsorption capacities (KOH/AC: 93.5 mgCO2/g K2CO3/AC: 94.5 mgCO2/gsample) K2CO3/Al+Si supports. This is due to the KOH or K2CO3 impregnation increased alkaline active sites (chemical adsorption), which is beneficial for CO2 adsorption. In addition, the regeneration test results showed both K-based adsorbents pose a good regeneration and reusability. Finally, the current study suggested that both KOH/AC and K2CO3/AC have a great potential to be used as CO2 adsorbent for indoor CO2 adsorption.

Monitoring and risk assessment of 1,4-Dioxane in Nakdong river (낙동강 수계 중 1,4-dioxane의 모니터링 및 위해성 평가)

  • Lee, Ji-Young;Kim, Joung-Hwa;Kim, Hyun-Koo;Choi, Jong-Ho;Kim, Seungki;Pyo, Heesoo
    • Analytical Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.383-391
    • /
    • 2008
  • International Agency for Research on Cancer (IARC) has classified it as a possible carcinogen and World Health Organization (WHO) has suggested 50 ng/mL as a guideline value for 1,4-dioxane. Considering the toxicity of 1,4-dioxane and ingestion rate of drinking water, the monitoring of 1,4-dioxane in drinking water in Nakdong river is very important. We analyzed 1,4-dioxane four times per year for the 12 samples of treated water and 4 samples of raw water in Nakdong river in Korea from 2000 to 2007 and surveyed the trend of concentrations of 1,4-dioxane. As a results of analysis, 1,4-dioxane was detected from 0.24 to 240.2 ng/mL in treated water and from 0.39 to 81.9 ng/mL in raw water from 2000 to 2007. The average concentrations are 22.68 ng/mL and 19.15 ng/mL in treated water and raw water, respectively. The detected concentrations was decreased but frequency of detection was not changed since establishment of regulation in 2004. Results of comparison of 95 percentile excessive cancer risk of 1,4-dioxane in treated and raw water were each $6.63{\times}10^{-6}$, $3.17{\times}10^{-6}$ before 2004 and $2.10{\times}10^{-6}$, $1.22{\times}10^{-6}$ after 2004. Also, comparing the detected concentration and frequency for each season, these were more detected the concentration and frequency for 1,4-dioxane in treated and raw water from winter to spring.

Retrieval of Hourly Aerosol Optical Depth Using Top-of-Atmosphere Reflectance from GOCI-II and Machine Learning over South Korea (GOCI-II 대기상한 반사도와 기계학습을 이용한 남한 지역 시간별 에어로졸 광학 두께 산출)

  • Seyoung Yang;Hyunyoung Choi;Jungho Im
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_3
    • /
    • pp.933-948
    • /
    • 2023
  • Atmospheric aerosols not only have adverse effects on human health but also exert direct and indirect impacts on the climate system. Consequently, it is imperative to comprehend the characteristics and spatiotemporal distribution of aerosols. Numerous research endeavors have been undertaken to monitor aerosols, predominantly through the retrieval of aerosol optical depth (AOD) via satellite-based observations. Nonetheless, this approach primarily relies on a look-up table-based inversion algorithm, characterized by computationally intensive operations and associated uncertainties. In this study, a novel high-resolution AOD direct retrieval algorithm, leveraging machine learning, was developed using top-of-atmosphere reflectance data derived from the Geostationary Ocean Color Imager-II (GOCI-II), in conjunction with their differences from the past 30-day minimum reflectance, and meteorological variables from numerical models. The Light Gradient Boosting Machine (LGBM) technique was harnessed, and the resultant estimates underwent rigorous validation encompassing random, temporal, and spatial N-fold cross-validation (CV) using ground-based observation data from Aerosol Robotic Network (AERONET) AOD. The three CV results consistently demonstrated robust performance, yielding R2=0.70-0.80, RMSE=0.08-0.09, and within the expected error (EE) of 75.2-85.1%. The Shapley Additive exPlanations(SHAP) analysis confirmed the substantial influence of reflectance-related variables on AOD estimation. A comprehensive examination of the spatiotemporal distribution of AOD in Seoul and Ulsan revealed that the developed LGBM model yielded results that are in close concordance with AERONET AOD over time, thereby confirming its suitability for AOD retrieval at high spatiotemporal resolution (i.e., hourly, 250 m). Furthermore, upon comparing data coverage, it was ascertained that the LGBM model enhanced data retrieval frequency by approximately 8.8% in comparison to the GOCI-II L2 AOD products, ameliorating issues associated with excessive masking over very illuminated surfaces that are often encountered in physics-based AOD retrieval processes.

Research on Immune Responses Induced by Salmonella Typhimurium Infectionin CRIP1-Deficient Condition (CRIP1결손조건 하에서 Salmonella Typhimurium 감염에 의해 유도되는 면역반응에 관한 연구)

  • Dongju Seo;Se-Hui Lee;Sun Park;Hyeyun Kim;Jin-Young Yang
    • Journal of Life Science
    • /
    • v.34 no.1
    • /
    • pp.48-58
    • /
    • 2024
  • Salmonella is a common food-borne intracellular bacterial pathogen that has triggered significant public health concerns. Salmonella hosts' genetic factors play a pivotal role in determining their susceptibility to the pathogen. Cysteine-rich intestinal protein 1 (CRIP1), a member of LIM/double zinc finger protein family, is widely expressed in humans, such as in the lungs, spleen, and especially the gut. Recently, CRIP1 has been reported as a key marker of several immune disorders; however, the effect of CRIP1 on bacterial infection remains unknown. We aimed to elucidate the relationship between Salmonella infection and CRIP1 gene deficiency, as Salmonella spp. is known to invade the Peyer's patches of the small intestine, where CRIP1 is highly expressed. We found that CRIP1-deficient conditions could not alter the characteristics of bone marrow-derived myeloid cells in terms of phagocytosis on macrophages and the activation of costimulatory molecules on dendritic cells using ex vivo differentiation. Moreover, flow cytometry data showed comparable levels of MHCII+CD11b+CD11c+ dendritic cells and MHCII+F4/80+CD11b+ macrophages between WT and CRIP1 knockout (KO) mice. Interestingly, the basal population of monocytes in the spleen and neutrophils in MLNs is more abundant in a steady state of CRIP1 KO mice than WT mice. Here, we demonstrated that the CRIP1 genetic factor plays dispensable roles in host susceptibility to Salmonella Typhimurium infections and the activation of myeloid cells. In addition, differential immune cell populations without antigen exposure in CRIP1 KO mice suggest that the regulation of CRIP1 expression may be a novel immunotherapeutic approach to various infectious diseases.

Temporal Changes in the Physiological and Psychological Relaxation Effects of a Forest Environment during the Summer (시간 변화에 따른 여름철 산림환경의 생리ᐧ심리적 안정 효과)

  • Injoon Song;Juhyeon Kim;Choyun Kim;Dawou Joung;Yunjeong Yi;Bum-Jin Park;Chorong Song
    • Journal of Korean Society of Forest Science
    • /
    • v.113 no.1
    • /
    • pp.107-117
    • /
    • 2024
  • This study investigated temporal changes in forest physical variables and their effects on thermal comfort and physiological and psychological responses. Environmental factors (air temperature, mean radiant temperature, wind speed, and relative humidity), the predicted mean vote (PMV), and the predicted percentage of dissatisfied (PPD) visitors were continuously measured between 9:00 AM and 6:00 PM. We assessed the physiological and psychological responses (heart rate variability, heart rate, oral temperature, blood pressure, pulse rate, thermal sensation vote, comfort sensation vote, and subjective feelings) of 30 male university students (average age: 21.7±1.9 years), who closed their eyes and relaxed for 5 minutes every hour. Examination of correlations between environmental factors and physiological responses showed that ① the mean radiant temperature, wind speed, and relative humidity significantly changed with time; ② PMV and PPD also showed significant changes over time, and the thermal sensation vote corresponded with PMV; however, the comfort sensation vote did not correspond with PPD; ③ Among the physiological responses, parasympathetic nerve activity, sympathetic nerve activity, heart rate, and diastolic blood pressure significantly varied with time, with parasympathetic nerve activity having the lowest value and sympathetic nerve activity the highest at the highest air temperature (2:00-4:00 PM); and ④ Air temperature, mean radiant temperature, and wind speed showed a negative correlation with parasympathetic nerve activity and a positive correlation with sympathetic nerve activity. These findings indicate that the relaxation effects of the forest environment depend on what time of day people are exposed to it, and the changes occurring in forest environmental factors over time modulate these effects.

The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF