• Title/Summary/Keyword: 인장시험시편

Search Result 277, Processing Time 0.027 seconds

The Effect of Electrolyte-coating on the Mechanical Performance of Carbon Fabric for Multifunctional Structural Batteries (다기능성 구조전지용 탄소섬유직물의 전해질 코팅이 기계적 성능에 미치는 효과)

  • Park, Hyun-Wook;Park, Mi-Young;Kim, Chun-Gon;Kim, Soo-Hyun
    • Composites Research
    • /
    • v.28 no.5
    • /
    • pp.285-290
    • /
    • 2015
  • Multiscale multiphysics in structural batteries make mechanical property testing difficult. In this research, the effect of electrolyte-coating on the mechanical performance of carbon fabric was studied using a suitable mechanical test method for structural batteries. For this experiment, two types of specimens were determined their dimension according to ASTM. One type of specimen was smaller than the standard dimension. The specimens were coated by spreading the electrolyte material on carbon fabric, hardened using epoxy, and tested for tensile properties using universal testing machine. As a result, it was found that the mechanical properties of carbon fabric were not influenced by electrolyte coating. In addition, the small-scale specimen used in this experiment was determined to be sufficiently reliable.

Crack Growth Instability for Ductile Material Using the Compact Tension Specimen (컴팩트 인장 시편을 이용한 연성 재료의 불안정 균열 성장에 관한 연구)

  • 이홍서;김희송
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.928-937
    • /
    • 1989
  • Applicability of $T_{\delta}$ proposed by Shin et al as an instability parameter for ductile material is investigated, Both general fracture test and instability fracture test are performed using compact tension specimens of structural alloy steel(SCM4), The values of ( $T_{\delta}$)$_{app}$(applied tearing modules) estimated from the real load vs. crack growth curve measured from experiments are compared with those estimated from the limit load vs. crack growth curve. The results are:(1) the $T_{\delta}$ parameter may be used as a crack instability parameter:(2) the use of ( $T_{\delta}$)$_{app}$ estimated from the load-crack growth curve, proposed in this study is reasonably justified.ified.d.

Effect of Wrinkling on Failure Behavior of Thin Membranes (얇은 막재에서 주름이 파괴거동에 미치는 영향)

  • Kim, Young-Ah;Woo, Kyeong-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.11
    • /
    • pp.1005-1012
    • /
    • 2011
  • In this paper, the effect of wrinkling on the failure behavior of thin membrane was studied using geometrically nonlinear shell element post-buckling analysis with global-local analysis strategy. In the analysis, double-edge notched and single-edge notched tensile specimen configurations were considered. The analyses were performed for both cases with allowing and suppressing the wrinkling deformation. The results were investigated focusing on the effect of wrinkle development on the variation of J-integral values at the cut tip. The effect of cut lengths and the specimen lengths were also systematically studied.

Analysis of Notched Bar Tensile Tests for Inconel 617 at Room and Elevated Temperatures (Inconel 617 노치시편의 상온 및 고온 인장실험 해석)

  • Oh, Chang-Sik;Ma, Young-Wha;Yoon, Kee-Bong;Kim, Yun-Jae
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1818-1823
    • /
    • 2007
  • In this paper, notched bar tensile tests of Inconel 617 were performed at room ($20^{\circ}C$) and elevated ($800^{\circ}C$) temperature. Finite element analyses are also performed. It is found that, at the room temperature, smooth bar tensile test results could be used to simulate notched bar tensile tests. However, at the elevated temperature, notched bar tensile test results can not be simulated from smooth bar tensile test results. Metallurgical examination reveals that strength weakening results from many cavities over the specimens for smooth bar test at the elevated temperature. "True" tensile properties at the elevated temperature is found using FE simulations. It also suggests that cautious should be taken to determine tensile properties of Inconel 617 at elevated temperatures using smooth bar tests.

  • PDF

마찰교반접합공정을 적용하여 겹치기 접합을 실시한 복합조직강의 미세조직과 기계적 특성

  • Kim, Sang-Hyeok;Lee, Gwang-Jin;U, Gi-Do
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.103.1-103.1
    • /
    • 2012
  • 본 연구는 차량경량화를 위하여 높은 인장강도와 우수한 인성을 가지는 590MPa급 이상조직강(Dual phase steel)을 이용하여 1991년 TWI(The Welding Institute)에서 개발된 마찰교반접합을 적용하여 접합을 실시하였다. 접합의 공정조건으로 툴의 회전속도는 250~350 RPM, 접합속도로는 50~350 mm/min로 겹치기접합을 실시하였다. 접합에서 사용된 툴은 Megastir에서 제작한 고융점마찰교반접합용 툴인 PCBN(Q-60)을 이용하였고 연구에 사용된 DP590은 포스코(POSCO)에서 제작된 1.4t(mm) 두께인 AHSS(advanced high strength steels)을 사용하였다. 모재인 DP590과 접합체의 미세조직은 광학현미경과 주사전자현미경을 이용하여 관찰하였으며 기계적 특성은 경도시험과 인장시험을 실시하여 조사하였다. 경도의 분포는 모재에서 약 220~230Hv이며 TMAZ부분에서 상승하기 시작하여 접합부에서 약 320Hv까지 상승하는 경향을 보였으며 인장시험 결과 접합속도 100~200 mm/min에서는 모든 시편이 모재에서 파단되어지는 것을 확인할 수 있었다. 위와 같은 결과 300~350 RPM, 100~200 mm/min의 공정조건에서는 접합이 성공적으로 이루어졌으며 차량경량화에 적용이 가능하다고 판단되어진다.

  • PDF

Tension Test to Develop a High-strength Wire Net (고강도 선제 포획망 개발을 위한 장력 테스트)

  • Jin, Hyunwoo;Seo, Sanghoon;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.1
    • /
    • pp.31-37
    • /
    • 2022
  • This study is focused on developing a technology to prevent high-strength wire net from expanding damage due to insufficient performance of the existing PVC coating net. For the test method, reference was made to ISO 17746, an international standard. In addition, as a result of referring to the test criteria, a wire net was fabricated with a width of 1,000 mm or more a size of 1 m2 sample. load-displacement curve of the test results was compared to analyze how much performance was improved compared to the existing PVC coating net.

The Tensile Strength at Room Temperature of Brazing Section for Materials used for Liquid Rocket Engine Combustion Chamber (액체 로켓엔진 연소기 사용 재료의 상온 브레이징부 인장강도 특성)

  • 정용현;류철성;최민수
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.73-79
    • /
    • 2003
  • The tensile strength test and the analysis for the section of brazing were performed in the cases of materials used for combustion chamber of regeneratively cooled liquid rocket engine. BNi-2 and BNi-7 based on nickel were used for brazing as filler metal. The properties of material and filler metal were analyzed by tensile strength test and metal microscope for 12 specimens. The tensile-strength of brazing for chrome-copper alloy and other kinds of alloy was higher than that of chrome-zirconium-copper alloy and other kinds of alloy The tensile strength in the case of BNi-2 as filler metal was higher than that of BNi-7 because the wetting property of BNi-2 was better than that of BNi-7.

Testing and Numerical Analysis on the Fracture Characteristics of Composite Adhesive Bonded Single-Lap Joints (복합재료 Single-Lap 본딩 조인트의 파괴 특성에 대한 실험 및 수치해석 연구)

  • 김광수;박재성;장영순;이영무
    • Composites Research
    • /
    • v.16 no.5
    • /
    • pp.45-53
    • /
    • 2003
  • The experimental and numerical investigations on the failure characteristics of the secondary bonded composite single-lap joints were performed. The initiations and growths of cracks were observed using CCD camera and acoustic emission sensor during the tension tests of the joint specimens. The structural behaviors of the specimens were predicted by the geometric nonlinear two-dimensional finite element analysis. The three types of observed initial cracks were included in each finite element models and the strain energy release rates of each specimen models were calculated by VCCT(Virtual Crack Closure Technique) technique. The tension tests showed that the initial cracks occurred in the 60∼90% of final failure loads and the major failure modes of the specimens were adhesive failure and the delamination between the 1st and 2nd ply of laminate. The specimens with the thicker bondline had earlier crack initiation loads but higher crack propagation resistance and eventually better loading capability. The delaminations were mostly observed in the thicker bondline specimens. The mode I values of calculated strain energy release rates were higher than the mode II values in the all specimen models considering the three types of initial cracks. The mode I and total strain energy release rates were calculated as higher values in the order of initial crack in the edge interface, comer interface and delamination between the plies of laminate.

EFFECT OF DENTIN SURFACE WETNESS ON TENSILE BOND STRENGTH OF SELF ADHESIVE RESIN CEMENTS (상아질 표면 젖음성이 수종 자가접착레진시멘트의 인장접착강도에 미치는 영향)

  • Yoon, Sung-Young;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.113-119
    • /
    • 2009
  • The purpose of this study was to compare the tensile bond strength of several self-adhesive resin cements bonded to dentin surfaces with different wet conditions. Three self-adhesive resin cements: Rely-X Unicem (3M ESPE, St. Paul, MN. USA). Embrace Wetbond (Pulpdent. Oakland. MA. USA). Maxcem (Kerr. Orange. CA. USA) were used. Extracted sixty human molars were used. Each self-adhesive resin cement was adhered to the dentin specimens (two rectangular sticks from each molar) in different wet conditions. Tensile bond strength were measured using universal testing machine (EZ Test. Shimadzu corporation. Kyoto. Japan) at a crosshead speed of 1.0mm/min. After the testing. bonding failures of specimens were observed by Operative microscope (OPMI pro, Carl Zeiss. Oberkochen, Germany). T-test was used to evaluate the effect of dentin surface wetness. One-way ANOVA test was used to evaluate the tensile bond strength of self-adhesive resin cements in the same condition. Scheffe's test was used for statistical analyzing at the 95% level of confidence. The result showed that wetness of dentin surface didn't affect tensile bond strength of self-adhesive resin cements and Maxcem showed the lowest tensile bond strength.

A Novel Tensile Specimen and Test Machine for Mechanical Properties of MEMS Materials (MEMS 소재의 기계적 특성 평가를 위한 인장형 시편 및 시험기 제작)

  • Park, Jun-Hyub;Kim, Chung-Youb;Lee, Chang-Seun;Choa, Sung-Hoon;Song, Ji-Ho
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.258-263
    • /
    • 2004
  • Mechanical property evaluation of micrometer-sized structures is necessary to help design reliable microelectromechanical systems(MEMS) devices. Most material properties are known to exhibit dependence on specimen size and such properties of microscale structures are not well characterized. This paper describes techniques developed for tensile testing of materials used in MEMS. Epi-polycrystalline silicon is currently the most widely used material, and its tensile strength has been measured as 1.52GPa. We have developed an uniaxial testing machine for testing microscale specimen using electro-magnetic actuator. The field magnet and the moving coil taken from an audio-speaker were utilized as the components of the actuator. Structure of specimen was designed and manufactured for easy handling and alignment. In addition to the static tensile tests, new techniques and procedures for measuring strength are described.

  • PDF