Analysis of Notched Bar Tensile Tests for Inconel 617 at Room and Elevated Temperatures

Inconel 617 노치시편의 상온 및 고온 인장실험 해석

  • 오창식 (고려대학교 기계공학과 대학원) ;
  • 마영화 (중앙대학교 기계공학과 대학원) ;
  • 윤기봉 (중앙대학교 기계공학과) ;
  • 김윤재 (고려대학교 기계공학과)
  • Published : 2007.05.30

Abstract

In this paper, notched bar tensile tests of Inconel 617 were performed at room ($20^{\circ}C$) and elevated ($800^{\circ}C$) temperature. Finite element analyses are also performed. It is found that, at the room temperature, smooth bar tensile test results could be used to simulate notched bar tensile tests. However, at the elevated temperature, notched bar tensile test results can not be simulated from smooth bar tensile test results. Metallurgical examination reveals that strength weakening results from many cavities over the specimens for smooth bar test at the elevated temperature. "True" tensile properties at the elevated temperature is found using FE simulations. It also suggests that cautious should be taken to determine tensile properties of Inconel 617 at elevated temperatures using smooth bar tests.

Keywords