• Title/Summary/Keyword: 인수

Search Result 3,448, Processing Time 0.031 seconds

Status of Fish Inhabitation and Distribution of Eight Abundant Species in Relation with Water Quality in Streams and Rivers, Ulsan City (울산 하천 및 강에서의 어류서식 현황 및 8개 대표종의 이화학적 수질 내성범위)

  • Seo, Jin-Won;Lim, In-Soo;Kim, Ho-Joon;Lee, Hye-Keun
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.3
    • /
    • pp.283-293
    • /
    • 2008
  • The objectives of the study were firstly to provide fundamental data for establishment of total maximum daily load (TMDL) management in Ulsan City, and secondly to make practical application of stream health assessment with tolerance range by each species when physiochemical and fish investigations were carried out together. A total of 44 sites in Taehwa River, Hoiya River, Dong Stream, and Cheongryang Stream were selected to monitor water qualities seasonally and fish investigation was performed in August 2006. Among the parameters of water quality, biological oxygen demand (BOD) and dissolved oxygen (DO) related to respiration, total nitrogen (T-N) and total phosphorus (T-P) related to nutrient and eutrophication, and total suspended solids (TSS) and $NH_4$-N were compared with vertical box plot by 8 dominant species. According to the fish investigation, 12 families 33 species were found including endangered species (Pungitius kaibarae) and introduced species (Lepomis macrochirus, Micropterus salmoides), and appearance rate of Korean endemic species was greater in Taehwa River (29.2%) than others. As the results of tolerance range by species, Zacco koreanus, Rhynchocypris oxycephalus, Iksookimia longicorpa, and Squalidus gracilis majimae had limited low range by water quality parameters indicating preference of good water quality. Whereas, Carassius auratus and Pseudorasbora parva were found downstream and urban-streams which were exposed from frequent inflow of pollutants. It concludes that the results help distinguishing sensitive, intermediate, and tolerant species when we evaluate stream health assessment with fish, and further making practical application for conservation and restoration of aquatic ecosystem.

A Survey on the Workplace Environment and Personal Protective Equipment of Poultry Farmers (양계 농업인의 작업장 환경 및 개인보호구 착용 실태조사)

  • Kim, Insoo;Kim, Kyung-Ran;Lee, Kyung-Suk;Chae, Hye-Seon;Kim, Sungwoo
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.454-468
    • /
    • 2014
  • Objectives: This study was conducted to investigate the actual condition of the farm work environment and personal protective equipment as part of the effort to improve livestock work for the safety and health of poultry farmers and provide basic data for establishing plans to improve and develop personal protective equipment. Methods: For this purpose, a questionnaire survey on general information about stables, the poultry work environment, accidents, the wearing of work clothes and personal protective equipment, and the level of awareness related to personal protective equipment was conducted among 148 poultry farmers. Results: As a result, it was found that poultry workplace environment was exposed to such risks as fine dusts; organic dusts; poisonous gases; odorous substances; chicken excrement; contact with chickens, bacteria or viruses; and accidents related to machine operation. Thirteen percent of respondents suffered severe respiratory diseases, and the most frequently injured sites due to accidents were the hands (25.7%), knees (23.8%), arms (17.3%), and head (10.9%). The most frequent type of accident was collisions between the body and obstacles or machinery during movement (36.4%), followed by erroneous machine operation such as feeders and electric shocks (8.5%). Regarding the wearing of work clothes and personal protective equipment, 51.7% of the respondents wore worn-out clothing or everyday clothes, whereas only 32.0% wore work clothes. The percentage of farmers who wore proper protective equipment for the work environment during poultry work was 48.4%. The most frequently used type of protective equipment was boots (38.9%), followed by mask (36.7%), gloves (36.3%), appropriate work clothes (22.6%), quarantine clothes (17.6%), helmets (13.4%), and goggles (12.6%). The rate of wearing goggles was low because they were considered inconvenient and lowered work efficiency. Furthermore, they purchased everyday products available on the market for their personal protective equipment which were not appropriate for maintaining safety in an actual harmful environment and its consequent risks. As a result of the survey of the awareness level related to personal protective equipment, their levels of awareness of accidents and attitude proved to be average or higher, but the practice of wearing protective equipment and the level of knowledge and management of personal protective equipment were lower. Conclusion: This survey found that the wearing status of personal protective equipment among poultry farmers was insufficient even though they were exposed to risks. Most respondents were aware of the necessity of wearing personal protective equipment and of the potential for accidents, but they did not wear proper protective equipment. Their wearing rate was low due to a lack of knowledge about protective equipment, as well as the inconvenience of wearing it. Therefore there is a need to improve and develop specialized personal protective equipment for respiration, hands, and eyes, as well as work clothes that can protect farmers from major harmful matter that is generated in the poultry workplace. Based on the results of this investigation, we will conduct further studies on the required performance and design directions of personal protective equipment while collecting more objective data through field-oriented assessments.

Minimal Invasive Surgery: A National Survey of Its Members by the Korean Association of Pediatric Surgeons (최소 침습 수술: 대한소아외과학회 회원을 대상으로 한 전국조사)

  • Kim, Dae Yeon;Kim, I.S.;Kim, H.Y.;Nam, S.H.;Park, K.W.;Park, W.H.;Park, Y.J.;Park, J.H.;Park, J.Y.;Park, J.S.;Park, J.Y.;Boo, Y.J.;Seo, J.M.;Seol, J.Y.;Oh, J.T.;Lee, N.H.;Lee, M.D.;Jang, J.H.;Jung, K.H.;Jung, S.Y.;Jung, S.E.;Jung, S.M.;Jung, E.Y.;Jung, J.H.;Cho, M.J.;Choi, K.J.;Choi, S.J.N.;Choi, S.O.;Choi, S.H.;Choi, Y.M.;Hong, J.
    • Advances in pediatric surgery
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Minimal invasive surgery (MIS) has rapidly gained acceptance for the management of a wide variety of pediatric diseases. A questionnaire was sent to all members of the Korean Association of Pediatric Surgeons. Thirty one members (25.4%) took part in the survey that included data for the year 2012: demographic details, opinion regarding minimal invasive surgery and robotic surgery, spectrum of minimally invasive operations, and quantity of procedures. 48.4% of the respondents had more than 10 years experience, 35.5% less than 10 years experience, and 16.1 % had no experience. The respondents of the recommend MIS and perform MIS for surgical procedures are as follow; inguinal hernia (61.3%), simple appendicitis (87.1%), complicated appendicitis (80.6%), reduction of intussusceptions (83.9%), pyloromyotomy (90.3%), fundoplication (96.8%), biopsy and corrective surgery of Hirschsprung's disease (93.5%/90.3%), imperforate anus (77.4%), congenital diaphragmatic hernia (80.6%), and esophageal atresia (74.2%). The MIS procedures with more than 70% were lung resection (100%), cholecystectomy (100%), appendectomy (96.2%), ovarian torsion (86.7%), fundoplication (86.8%), hiatal hernia repair (82.6%), and splenectomy (71.4%). The MIS procedures with less than 30% were congenial diaphragmatic hernia reapir (29.6%), esophageal atresia (26.2%), correction of malroatation (24.4%), inguinal hernia repair (11.4%), anorectal malformation (6.8%), Kasai operation (3.6%).

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

Components of White and Dark Muscle of Skipjack for Canning (통조림용 가다랑어육의 식품성분)

  • OH Kwang-Soo;KIM Jeong-Gyun;KIM In-Soo;LEE Eung-Ho;KIM Bok-Gyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.23 no.2
    • /
    • pp.178-184
    • /
    • 1990
  • The lipid components, nitrogenous extracts and amino acids of dark muscle(DM) of ski-pjack (Katsuwonus pelamis) were analyzed and compared with those of white muscle (WM). WM was higher in moisture and crude protein content, and lower in crude lipid and ash content than those of DM. Contents of volatile basic nitrogen in WM and DM were 22.7mg/100g and 46.9mg/100g. Total lipid(TL) of WM and DM consisted of $79.7\%,\;71.9\%$ neutral lipid(NL), $6.8\%,\;9.5\%$ glycolipid(GL), and $13.5\%,\;18.6\%$ phospholipid(PL), respectively NL was mainly com-posed of free fatty acid, triglyceride, and PL was mainly occupied by phosphatidyl ethanolamine, phosphatidyl choline. Also Iysophosphatidyl choline and Iysophosphatidyl ethanolamine were identified in PL. In fatty acid composition of TL, NL, GL and PL, WM revealed higher contents in saturates and monoenes such as 16 : 0, 18 : 1, while DM showed higher contents in polyenes such as 22 : 6 especially. The major fatty acids of these samples were generally 16: 0, 18:0, 18:1, 20:5 and 22 : 6. Contents of total free amino acids from WM and DM were 5,982.3mg/100g and 4,450.7 mg/100g (dry base). Of free amino acids, Tau concentration was much higher in DM than in WM, Ala, Gly, Met, Arg, Thr were also high in DM. But His was much higher in concentration in W. Content of inosinic acid(IMP) in WM(680.9mg/100g) was higher than that of DM(73.1mg/100g). The degradations of IMP proceeded very rapidly in DM. DM contained much higher trimethylamine oxide and trimethylamine than those of WM. The profile of combined amino acids in these samples, were very similar, and main amino acids were Glu, Asp, Lys, Ala, Ile and Arg.

  • PDF

Postmortem Degradation of Fish Muscle Proteins 1. Nature of proteolysis and bacterial contribution (어육단백질의 사후분해 1. 단백질분해의 본질과 세균기여)

  • CHUNG Jong Rak;KIM In Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.9 no.2
    • /
    • pp.120-128
    • /
    • 1976
  • Two experiments were conducted to study the nature of protein degradation in fish muscle postmortem, first one with English sole (Paraphyrus vetulus) followed by another with rockfish (Sebastodes spp.). In the first one, proteolysis was measured by the increase of amino-N in gutted fish during storage in ice and in the homogenates prepared from fish of different ice storage during $20^{\circ}C-incubation$. In order to test the possible involvement of fish muscle a cathepsin, a portion of each homogenate sample was exposed to 0.5 Mrad of gamma radiation to destroy viable microorganisms prior to the incubation. Proteolysis was not detected until viable count reached a level above $10^7$ cells per gm fish flesh, corresponding to 31 days of ice storage. Even if fish flesh were mechanically disrupted by means of homogenization and subsequently incubated at $20^{\circ}C$, proteloysis attributable to muscle cathepsin was not detected. In the second with rockfish muscle aseptically prepared from freshly killed fish, the samples were inoculated with a proteolytic strain of fish spoilage Pseudomonad or irradiated at 0, 0.5 and 3.0 Mrad. The four samle groups were stored at $0-2^{\circ}C$ to compare the spoilage pattern of sterile and non-sterile muscle. In sterile muscle both total-N (extracted in 0.5M KCl) and amino-N $(soluble\;in\;70\%\;ethanol)$ declined slightly while the inoculated muscle showing increase in parallel with the increase of number of inoculated bacterium. The results indicate that proteolysis is a part of normal fish spoilage and the onset of proteolysis is delayed until viable count reaches its maximum level. Contribution of fish muscle cathepsin to protein degradation in white flesh fish muscle post-mortem is nil.

  • PDF

Evolution of Mechanical Properties through Various Heat Treatments of a Cast Co-based Superalloy (주조용 코발트기 초내열합금의 열처리에 따른 기계적 특성 변화)

  • Kim, In-Soo;Choi, Baig-Gyu;Jung, Joong-Eun;Do, Jeong-Hyeon;Jung, In-Yong;Jo, Chang-Yong
    • Journal of Korea Foundry Society
    • /
    • v.38 no.5
    • /
    • pp.103-110
    • /
    • 2018
  • The effects of a heat treatment on the carbide formation behavior and mechanical properties of the cobalt-based superalloy X-45 were investigated here. Coarse primary carbides formed in the interdendritic region in the as-cast specimen, along with the precipitation of fine secondary carbides in the vicinity of the primary carbides. Most of the carbides formed in the interdendritic region were dissolved into the matrix by a solution treatment at $1274^{\circ}C$. Solutionizing at $1150^{\circ}C$ led to the dissolution of some carbides at the grain boundaries, though this also caused the precipitation of fine carbides in the vicinity of coarse primary carbides. A solution treatment followed by an aging treatment at $927^{\circ}C$ led to the precipitation of fine secondary carbides in the interdendritic region. Very fine carbides were precipitated in the dendritic region by an aging heat treatment at $927^{\circ}C$ and $982^{\circ}C$ without a solution treatment. The hardness value of the alloy solutionized at $1150^{\circ}C$ was somewhat higher than that in the as-cast condition; however, various aging treatments did not strongly influence the hardness value. The specimens as-cast and aged at $927^{\circ}C$ showed the highest hardness values, though they were not significantly affected by the aging time. The specimens aged only at $982^{\circ}C$ showed outstanding tensile and creep properties. Thermal exposure at high temperatures for 8000 hours led to the precipitation of carbide at the center of the dendrite region and an improvement of the creep rupture lifetimes.

Monte Carlo Study Using GEANT4 of Cyberknife Stereotactic Radiosurgery System (GEANT4를 이용한 정위적 사이버나이프 선량분포의 계산과 측정에 관한 연구)

  • Lee, Chung-Il;Shin, Jae-Won;Shin, Hun-Joo;Jung, Jae-Yong;Kim, Yon-Lae;Min, Jeong-Hwan;Hong, Seung-Woo;Chung, Su-Mi;Jung, Won-Gyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.192-200
    • /
    • 2010
  • Cyberknife with small field size is more difficult and complex for dosimetry compared with conventional radiotherapy due to electronic disequilibrium, steep dose gradients and spectrum change of photons and electrons. The purpose of this study demonstrate the usefulness of Geant4 as verification tool of measurement dose for delivering accurate dose by comparing measurement data using the diode detector with results by Geant4 simulation. The development of Monte Carlo Model for Cyberknife was done through the two-step process. In the first step, the treatment head was simulated and Bremsstrahlung spectrum was calculated. Secondly, percent depth dose (PDD) was calculated for six cones with different size, i.e., 5 mm, 10 mm, 20 mm, 30 mm, 50 mm and 60 mm in the model of water phantom. The relative output factor was calculated about 12 fields from 5 mm to 60 mm and then it compared with measurement data by the diode detector. The beam profiles and depth profiles were calculated about different six cones and about each depth of 1.5 cm, 10 cm and 20 cm, respectively. The results about PDD were shown the error the less than 2% which means acceptable in clinical setting. For comparison of relative output factors, the difference was less than 3% in the cones lager than 7.5 mm. However, there was the difference of 6.91% in the 5 mm cone. Although beam profiles were shown the difference less than 2% in the cones larger than 20 mm, there was the error less than 3.5% in the cones smaller than 20 mm. From results, we could demonstrate the usefulness of Geant4 as dose verification tool.

Variation of Air Temperature Inside Carbonate Area Caves (석회암 지역에 분포하는 동굴의 내부 온도 변동 특성)

  • Kim, Lyoun;Park, Youngyun;Lee, Jonghee;Choi, Jaehun;Jung, Qyusung;Kim, Jungtae;Kim, Insu
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.52-63
    • /
    • 2020
  • This study was conducted in order to evaluate the characteristics of air temperature fluctuation inside the Daegeumgul, Ondaldonggul, and Seongnyugul Caves, which are the most representative limestone caves in Korea, and also to assess the effects of air temperature on cave temperature. Temperature was measured hourly at three sites in Daegeumgul, Ondaldonggul, and Seongnyugul Caves from April 13 to June 25, 2019. Additionally, air temperature data for the areas around the caves was provided by the Meteorological Administration. Using this collected data, the basic statistical measure of fluctuation characteristics over time was ascertained, and time series analyses were performed. Wide variation of temperature was exhibited in the order of the cave entrance, the cave water inflow point, and the midpoint. Cave temperature was observed to increase gradually during the study period. There was a vast range in temperature at the Daegeumgul station located approximately 150 m outside the cave, but it remained nearly constant beyond the midpoint. Although the effect of air temperature was not significant due to the influence of visitors, the effect of air temperature on cave temperature gradually decreased from the entrance to the interior. At Ondaldonggul, there was a wide range in temperature recorded at the entrance due to the influence of air temperature, but it stayed almost constant in the interior. However, at the site where cave water flows into the cave, temperature was influenced by the cave water temperature. At Seongnyugul, there was a distinct fluctuation in temperature recorded at the cave entrance, while the middle of the cave remained nearly constant. Temperature fluctuated due to the air temperature at the entrance, while at the middle of the cave, measurements were expected to be affected to a greater extent by the lake water temperature than by the air temperature. However, this pattern was not observed. According to the time series analysis results, in all caves, fluctuations of air temperature affected cave temperature after approximately one hour. Cave size and structure, water presence, the entrance's size and shape, air flow, and visitor patterns can all influence cave temperature. Therefore, consideration of these factors is very important in the pursuit to clearly understand cave temperature characteristics.

Evaluation of the Usefulness of Assist Device for Rosenberg View Test (Rosenberg View 검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Kim, In Soo;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.129-138
    • /
    • 2020
  • Due to the nature of the Rosenberg Method, the patient needs to maintain posture for a certain period of time, and the joint space is observed in various forms depending on the angle of knee flexion, which causes difficulties in examination. In order to solve these problems, Image quality was evaluated in order to evaluate the usefulness of the assistive device by making the assistive device itself. SNR and CNR analysis about the presence or absence of an assistive device using the extremity phantom and the angle of the assistive device itself were not statistically significant(p < 0.05). As a result of measuring the distance between the right and left edges of the medial condyle based on the presence or absence of an assist device, and the absence of assist device (96.00±40.6 mm) and presence of an assist device (134.86±17.68 mm) were statistically significant (p <0.05). To find the aLDFA relationship about the femur and tibia, we measured the right and left aLDFA based on the presence or absence of assist device. As a result, the absence of the right-side aLDFA assist device (74.63°±4.87) and the presence of assist device (79.64°±3.65) were statistically significant (p <0.05). The absence of the left-side aLDFA assist device (76.39°±4.62) and the presence of assist device (79.64°±3.65) were statistically significant (p < 0.05). but, As a result of measuring the distance of the overlapping parts of the right and left proximal tibiofibular joint and the lateral condyle, There were no statistically significant differences between the right and left sides. In conclusion, we confirmed that we can obtain Diagnostically valuable images with a constant knee-to-knee spacing using an assist device we self-created. In addition, we could learn through aLDFA relationship between femur and tibial that the smaller the angle, the more medial condyle overlaps with JSW, We also confirmed the significance by deriving similar values on the normal range values of aLDFA using assist devices. However, it is considered necessary to pay attention to internal and external rotations in order to obtain good quality images by evaluating the distance of overlapping parts between proximal tibiofibular joint and lateral condyle.