• Title/Summary/Keyword: 인레이

Search Result 64, Processing Time 0.027 seconds

INFLUENCE OF THREE DIFFERENT PREPARATION DESIGNS ON THE MARGINAL AND INTERNAL GAPS OF CEREC3 CAD/CAM INLAYS (세 가지 다른 인레이 와동 형태가 CEREC3 CAD/CAM의 변연 및 내면 간극에 미치는 영향)

  • Seo, Deog-Gyu;Yi, Young-Ah;Lee, Yoon;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • The aim of this study was to evaluate the marginal and internal gaps in CEREC3 CAD/CAM inlays of three different preparation designs. CEREC3 Inlays of three different preparation designs (n=10) were fabricated according to Group I-conventional functional cusp capping/shoulder preparation, Group II-horizontal reduction of cusps and Group III-complete reduction of cusps/shoulder preparation. After cementation of inlays. the bucco-lingual cross section was performed through the center of tooth. Cross section images of 20 magnifications were obtained through the stereomicroscope. The gaps were measured using the Leica application suite software at each reference point. Statistical analysis was performed using one-way ANOVA and Tukey's test (${\alpha}<0.05$). The marginal gaps ranged from 80.0 to $97.8{\mu}m$ for Group I, 42.0 to $194.8{\mu}m$ for Group II, 51.0 to $80.2{\mu}m$ for Group III. The internal gaps ranged from 90.5 to $304.1{\mu}m$ for Group I, 80.0 to $274.8{\mu}m$ for Group II, 79.7 to $296.7{\mu}m$ for Group III. The gaps of each group were the smallest on the margin and the largest on the horizontal wall. For the CEREC3 CAD/CAM inlays, the simplified designs (groups II and III) did not demonstrate superior results compared to the traditional cusp capping design (group I).

Boe Recent Progress in Prosthodonitics (치과보철분야의 최근동향)

  • Kim, Gwang-Nam
    • The Journal of the Korean dental association
    • /
    • v.21 no.3 s.166
    • /
    • pp.195-198
    • /
    • 1983
  • 저작, 발음, 미관등 3대기능회복에 주안점을 두어왔던 치과보철학은 근년에 와서 l아 및 그 주위조직, 악골 및 악관절, 저작근육들과 그들을 지배하는 신경계통등 구강악계(stomatognathic system)의 total treatment로 더욱 발전되어 가고 있다. 구강악계를 구성하는 조직들은 각기 독립적으로 저작, 발음, 연하등 그 기능적 행위에 참여하는 것이 아니라 서로 긴밀한 협조와 조화에 의하여 이루어 지기 때문에 어떠한 조직의 잘못된 치료는 한 개의 기능적 단위인 구강악계전체에 영향을 미치게된다. 그러므로 치과수복 치료에 있어서 단순한 인레이로 부터 전구강회복에 이르기까지 이들 보철물들은 기능운동시 다른 조직들과 잘 조화되어야 된다는 것은 당연한 사실이다.

  • PDF

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.

Preparation guidelines for CAD/CAM inlay/onlay restorations (CAD-CAM 인레이/온레이 수복을 위한 와동형성의 가이드라인)

  • Son, Song Ae
    • The Journal of the Korean dental association
    • /
    • v.54 no.8
    • /
    • pp.651-657
    • /
    • 2016
  • Currently with the continuous development of ceramic and cementation materials, CAD-CAM(Computer-aided design/Computer-aided manufacture) restorations are becoming increasingly popular in esthetic dentistry. Preparation design is influenced by the selected restorative material, the fabrication method, and the ability to bond the restoration. For long-lasting CAD/CAM inlay/onlay restoration, clinicians should understand the basic knowledge of CAD/CAM restoration's cavity design to obtain the fracture resistance and proper fitting margin. This article gives an overview of preparation guidelines for CAD/CAM inlay/onlay restorations.

  • PDF

임상가를 위한 특집 1 - 지르코니아의 역사 및 이론적 배경

  • No, Gyeong-Ho;Ha, Seung-Ryong;Kim, Seong-Hun
    • The Journal of the Korean dental association
    • /
    • v.47 no.12
    • /
    • pp.798-803
    • /
    • 2009
  • 지르코니아는 물리적 성질이 금속과 가장 가까운 세라믹이며, 색상이 치아와 비슷하여 치과분야에서 사용빈도가 증가하고 있는 재료이다. 지르코니아는 zirconium dioxide 결정체로서, 1975년 Garvie가 'ceramic steer' 이라고 명명하였듯이 기존의 세라믹과 비교하여 뛰어난 물성을 지니고 있다. 즉, 높은 내열성과 낮은 열전도도, 산성에서 알카리성까지 이르는 내화학 안정성, 낮은 열팽창성, 높은 강도 및 경도, 내마모성을 가지고 있기 때문에 이전부터 공업용 재료로 넓게 시용되어 왔다. 지르코니아의 상변 이를 이용한 toughening방법이 Garvie에 의해 제시됨으로서 세라믹의 최대 단점인 취성은 어느 정도 극복할 수 있게 되었고 이를 계기로 금관 및 계속가공 의치, 임플란트 지대주, 인레이, 온레이 등 치과의 여러 분야에 지르코니아를 적용할 수 있게 되었다. 최근에는 임플란트 매식체에 있어서도 그 적용을 시도함으로서 심미치과치료에 있어서 중요한 부분으로 자리 잡고 있다. 현재 지르코니아는 치과용 세라믹 중에서 가장 높은 기계적 물성을 보이기 때문에 구치부 에서의 사용 가능성이 시도되고 있으며, 코어의 두께를 감소시킴으로써 보철 술식에서 필요한 강도 및 심미성 두 마리 토끼를 잡을 수 있도록 많은 연구가 이루어지고 있다. 이에 지르코니아의 역사 및 이론적 배경에 대하여 알아보고자 한다.

  • PDF

Bonding efficacy of cured or uncured dentin adhesives in indirect resin (간접 레진수복시 상아질 접착제의 중합 여부에 따른 결합 효능)

  • Jang, Ji-Hyun;Lee, Bin-Na;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.490-497
    • /
    • 2011
  • Objectives: This study examined the effect of the uncured dentin adhesives on the bond interface between the resin inlay and dentin. Materials and Methods: Dentin surface was exposed in 24 extracted human molars and the teeth were assigned to indirect and direct resin restoration group. For indirect resin groups, exposed dentin surfaces were temporized with provisional resin. The provisional restoration was removed after 1 wk and the teeth were divided further into 4 groups which used dentin adhesives (OptiBond FL, Kerr; One-Step, Bisco) with or without light-curing, respectively (Group OB-C, OB-NC, OS-C and OS-NC). Pre-fabricated resin blocks were cemented on the entire surfaces with resin cement. For the direct resin restoration groups, the dentin surfaces were treated with dentin adhesives (Group OB-D and OS-D), followed by restoring composite resin. After 24 hr, the teeth were assigned to microtensile bond strength (${\mu}TBS$) and confocal laser scanning microscopy (CLSM), respectively. Results: The indirect resin restoration groups showed a lower ${\mu}TBS$ than the direct resin restoration groups. The ${\mu}TBS$ values of the light cured dentin adhesive groups were higher than those of the uncured dentin adhesive groups (p < 0.05). CLSM analysis of the light cured dentin adhesive groups revealed definite and homogenous hybrid layers. However, the uncured dentin adhesive groups showed uncertain or even no hybrid layer. Conclusions: Light-curing of the dentin adhesive prior to the application of the cementing material in luting a resin inlay to dentin resulted in definite, homogenous hybrid layer formation, which may improve the bond strength.

EFFECT OF RESTORATION TYPE ON THE STRESS DISTRIBUTION OF ENDODONTICALLY TREATED MAXILLARY PREMOLARS; THREE-DIMENSIONAL FINITE ELEMENT STUDY (수복물의 종류가 근관치료된 상악 제2소구치의 응력분포에 미치는 영향: 3차원 유한요소법적 연구)

  • Jung, Heun-Sook;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.8-19
    • /
    • 2009
  • The purpose of this study was to investigate the effects of four restorative materials under various occlusal loading conditions on the stress distribution at the CEJ of buccal. palatal surface and central groove of occlusal surface of endodontically treated maxillary second premolar, using a 3D finte element analysis. A 3D finite element model of human maxillary second premolar was endodontically treated. After endodontic treatment, access cavity was filled with Amalgam, resin, ceramic or gold of different mechanical properties. A static 500N forces were applied at the buccal (Load-1) and palatal cusp (Load-2) and a static 170N forces were applied at the mesial marginal ridge and palatal cusp simultaneously as centric occlusion (Load-3). Under 3-type Loading condition, the value of tensile stress was analyzed after 4-type restoration at the CEJ of buccal and palatal surface and central groove of occlusal surface Excessive high tensile stresses were observed along the palatal CEJ in Load-1 case and buccal CEJ in Load-2 in all of the restorations. There was no difference in magnitude of stress in relation to the type of restorations. Heavy tensile stress concentrations were observed around the loading point and along the central groove of occlusal surface in all of the restorations. There was slight difference in magnitude of stress between different types of restorations. High tensile stress concentrations around the loading points were observed and there was no difference in magnitude of stress between different types of restorations in Load-3.

Comparative analysis of distance measurement on the rendering screen between dental CAD programs (치과용 CAD 프로그램의 렌더링 화면상 거리측정 비교분석)

  • Cha, Cheol-Ho;Lim, Seon-Young;Bang, Ju-Hyuk;Kim, Seong-Ah;Kim, Seong-Yong;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.11-17
    • /
    • 2021
  • Purpose: This study was to find out whether the rendering screen difference affect to measuring distance in a CAD program according to three types of CAD programs. Materials and methods: The model presented in ISO 12836 for dental scanner evaluation was reduced by 70%. This model was repeatedly scanned 15 times using Trios II (3Shape, Denmark). Using the output STL file, 3Shape CAD, inLab 15, and ExoCAD programs were used to measure the horizontal distance (H) and vertical distance (V) between adjacent point angle, and for each experiment, three groups were set according to the CAD program type. Statistical analysis was performed using One-way ANOVA test and post hoc was performed using Dunnett T3 test. Results: In the horizontal and vertical distance measurement, there was no difference in the average of the measured values between the three groups according to the CAD program (P>.05). Conclusion: There were no effect of the difference in the rendering screen in the horizontal and vertical linear distance measurements of the inlay model on the dental CAD program.

Design of UHF RFID Tag Considering Chip Characteristic (칩 특성을 고려한 UHF RFID 태그 설계)

  • Lee, Hong-Joo;Hwang, Gun-Yong;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.2
    • /
    • pp.194-200
    • /
    • 2011
  • Recently, RFID(Radio Frequency IDentification) market spread in industry region is entering a phase of stagnation due to cost issue. RFID tag inlay cost has become relatively more expensive due to the recent decrease in chip price. Therefore, a simple and rapid design technique for RFID tag has yet to be implemented to achieve low cost. This paper presents a design technique considering chip impedance for antenna design for improved accuracy and computation time. As a result, it is confirmed that analysis error for resonance ranges within 20MHz and readable range error falls within 1.5m.

The flow change of the inlay waxes at various temperatures (온도변화에 따른 인레이 왁스의 유동성 변화)

  • Nam, Sang-Yong;Lee, Duk-Su
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.367-373
    • /
    • 2006
  • This study was performed to observe the flow change of the inlay waxes at various temperatures. The flow of inlay waxes was tested according to the treatment conditions, for 10 minutes at 40$^{\circ}C$, 41$^{\circ}C$, 42$^{\circ}C$, 43$^{\circ}C$, 44$^{\circ}C$, and 45$^{\circ}C$ The flow of inlay waxes at various temperatures was measured with an electro dial gauge. The results were as fellows: 1. The flow change of the inlay waxes at various temperatures was shown to increase in the order of wax A, B, D, C. 2. Wax A was close to ADA specification with 3% flow at 40$^{\circ}C$ and 71% flow at 45$^{\circ}C$, but wax B and D did not reach up to ADA specification with 40% flow at 45$^{\circ}C$. 3. Wax C came up with 3% flow at 40$^{\circ}C$ and 7% flow at 45$^{\circ}C$, and it revealed a very low flow change at 5$^{\circ}C$.

  • PDF