• Title/Summary/Keyword: 인공 혈관

Search Result 391, Processing Time 0.027 seconds

Artificial intelligence-based blood pressure prediction using photoplethysmography signals

  • Yonghee Lee;YongWan Ju;Jundong Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.11
    • /
    • pp.155-160
    • /
    • 2023
  • This paper presents a method for predicting blood pressure using the photoplethysmography signals. First, after measuring the optical blood flow signal, artifacts are removed through a preprocessing process, and a signal for learning is obtained. In addition, weight and height, which affect blood pressure, are measured as additional information. Next, a system is built to estimate systolic and diastolic blood pressure by learning the photoplethysmography signals, height, and weight as input variables through an artificial intelligence algorithm. The constructed system predicts the systolic and diastolic blood pressures using the inputs. The proposed method can continuously predict blood pressure in real time by receiving photoplethysmography signals that reflect the state of the heart and blood vessels, and the height and weight of the subject in an unconstrained method. In order to confirm the usefulness of the artificial intelligence-based blood pressure prediction system presented in this study, the usefulness of the results is verified by comparing the measured blood pressure with the predicted blood pressure.

The Clinical Experiences of "New Duromedics Valve" Replacement (새로운 Duromedics 인공판막 치환의 임상고찰)

  • Gang, Myeon-Sik;Yu, Gyeong-Jong;Yun, Chi-Sun;Park, Han-Gi
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.979-985
    • /
    • 1997
  • Between October 1991 and May 1995, 256 "New Duromedics Valve"(Edward TEKNA Bileaflet Valve) were implanted in 208 adult patients(171 mitral, 82 aortic and 3 tricuspid) with age ranging from 18 years to 70 years(mean 48.2$\pm$ 11.6 years). Postoperative complication rates were 12.2%, but there was none valve related one. Overall early mortality rate were 1.4%(1.6% for MVR, 2.1% for DVR, and none for AVR or TVR) respectively. Follow-up was 99% completed ranging in duration from 2 months to 46 months. There were 6 valve-related late complications(2.9%) with 2 patients with upper gastrointestinal bleeding, 2 with cerebral thxomtioembolism, 1 with valve thrombosis and 1 with valve endocarditis. Freedom from these valve-related major complications were 89.9% at 40 months. There were 5 late deaths(2.4%). one of these late deaths was considered valve-related. Overall actuarial survival rates at 40 months were 95.5%, 96.8% for mitral, 97.1% for aortic, 100% for tricuspid, and 92.0% for double valve replacement respectively. Preoperative New York Heart Association functional class were 2.9, and 1.3 in post-operative state. We have been trying to keep the international normalized ratio(INR) with range of 2.5 to 3.0. The INR of 4 patients of 5 with anticoagulant ralated complications was beyond the range. To reduce the rate of anticoagulant related complications, we felt very strongly that the INR should be kept between 2.5 and 3.0. In our cases, there was no structural failure or significant hemolysis in the absence of periprosthetic leak. This experience encourages us to continue using the "New Duromedics Valve".omedics Valve".uot;.

  • PDF

Mitral Reconstruction Using Prosthetic Ring in Mitral Valvular Heart Disease (승모판막질환에 있어서 인공판륜을 이용한 승모판막재건술의 임상적 고찰)

  • 나명훈;황경환
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.598-606
    • /
    • 1997
  • Among 136 patients having undergone mitral valve surgery from September of 1994 through August of 1995 in Sejong Heart Institute, forty four patients(18 males, 26 females) underwent mitral valve reconstruction using prosthetic rings and their clinical results were evaluated. Patients'ages ranged from 5 to 63 years(mean age 38.2 years). Mitral valvular diseases were due to rheumatic origin in 30 patients(68%), degenerative in 13(30%), and congenital in one patient(2%). Mitral regurgitation(MR) was in 33 patients(76%), mitral stenosis 2(5%), and mitral stenoinsufaciency 9 patients(19%). The patients were divided into Carpentier's functional groups : type I, 5 patients(11%) : type I, 24 patients(55%) ; type III, 4 patients (9%) i and mixed(II + III), 11 patients(25%). Average number of anatomic lesions of mitral valve per patient was 3.7. The techniques included prosthetic ring amluloplasty(44 patients, 32 Carpentier ring and 12 Duran ring), leaflet mobilization(24, 55%), chordae shortening(23, 52%), chordae transposition(23, 52%), commissurotomy(16, 35%), leaflet resection(9, 20%), papillary muscle splitting(8, 18%), and chordae reimplantation(1, 2%). Average 3.4 surgical procedures were applied on mitral valve per patient. There were two hospital mortality and one reoperation due to development of MR(grade III) after 2 weeks. During the mean follow up of 12 months, patients improved in terms of functional class of the New York Heart Association, which was mean 3.0 preoperatively and 1.3 postoperatively. Doppler echocardiographic studies showed adequate valve area(2.07$\pm$0.11 cm2 mean $\pm$standard error), improved ventricular contractiliy in 41 patients(93%), ab ence of MR in 23(53%), trace MR in 18(42%), and garde II MR in 2 patients(5%).

  • PDF

Direct Closure of Post-Incubation Tracheoesophageal Fistulas, -Report of 3 Cases- (기관내 삽관 후 발생한 기관식도루의 직접 봉합에 의한 수술적 치료 -3례 보고-)

  • Gang, Jong-Ryeol;Lee, Hong-Seop;Kim, Chang-Ho
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.1045-1049
    • /
    • 1996
  • Post-intubation tracheoesophageal fistula is rare, and its management causes a serious problems to surgeons. We have experienced 4 cases in 3 patients. Simple ditcision and closure of the fistulas were done by trans-cervical approach after weaning of ventilator. The tracheal defect was closed by simple suture, and the esophageal defect was closed in two layers before a viable muscle flap was interposed between the two suture lines in order to prevent recurrence. There was one delayed tracheal stenosls and one recurrent fistula, and these complications were also managed success ully.

  • PDF

Reoperations for Prosthetic Valve Replacement (인공판막치환술후 재수술)

  • 유영선
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1090-1097
    • /
    • 1991
  • Between January 1981 and January 1991, 554 patients underwent prosthetic valve replacement. A bioprosthetic valve was replaced in 238 cases and mechanical valve 316 cases. Thirty-eight patients underwent 40 reoperations for repair or replacement, an average of 53.6 months after initial implantation. There were 21 women and 19 men, aged 12 to 60 years[mean 35.3]. A bioprosthetic valve was implanted in 31 cases and a mechanical valve in 9 cases for initial operation. Indications for reoperation were primary tissue failure in 23 cases[57.5%], endocarditis in 9[22.5%], periprosthetic leak in 4[10%]. and valve thrombosis in 4[10%]. Operations performed included 5 aortic valve replacements, 26 mitral valve replacement, 8 double valve replacements, and 1 thrombectomy. A mechanical valve was replaced in 33 cases[84.6%] and a bioprosthesis in 6[15.4Zo] for reoperation. A second reoperation was required in 2 patients. Surgical mortality was 10% . Among the 34 early survivors followed-up for an average of 19.8 months. there was 1 late death and 3 were lost to follow-up. Among the 30 late survivors being followed up, 28[93.3%] remained in New York Heart Association Class I or II and two in Class III [6.7%].

  • PDF

Re-replacement of prosthetic heart valves: report of 7 cases (인공심장판막의 재치환수술: 7례 보)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.3-11
    • /
    • 1984
  • Prosthetic valve replacement has resulted in marked improvement in the functional status of many patients with valvular heart disease. But valve failure from various causes has necessitated re-replacement of prosthetic valve in some of these patients. This selective group of patients has many inherent problems. This report presents our experience with seven patients who received re-replacement of prosthetic valve in the Seoul National University Hospital from 1981, to 1983. The patients included one woman and six men in the range of 9 and 49 years old. As the first valve operations, there were five MVR using tissue valves, one DVR [Bjork-Shiley and Ionescu-Shiley valve] and one case of modified Bentall operation with composite graft [Ionescu-Shiley valve]. Reoperations on prosthetic valve failure were performed 17 to 54 months after the first operation [mean 34 months]. Amon8 seven patients, there were two cases of prosthetic valve endocarditis and five cases of primary tissue failure. Gross calcification of the xenograft was found in two children with Ionescu-Shiley valve. All except one had relatively successful operative results. The unsuccessful one died intraoperatively from low output syndrome.

  • PDF

Prediction of the Prosthetic Valve size by use of Supraaortic Cineangiogram (Cineangiogram 을 이용한 대동맥판막의 수술전 인공판막 치수의 예)

  • Lee, Young-Thak;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.60-64
    • /
    • 1987
  • We compared between prosthetic aortic valve size and aortic annulus size in supravalvular aortic cineangiogram in 30` RAO view postoperatively. Retrospectively, supraaortic cineangiogram of 27 patients among the patients underwent aortic valve replacement only or double valve replacement from April, 1986 to January, 1987 was examined and measured the aortic annulus size. In comparing the two values, the cases within 1mm is 22, and the cases within 2mm is 25, correlation coefficient yield r = 0.92. In two cases, the difference between two values is within 3mm We concluded that to prevent the complication from mismatching the prosthetic aortic valve size to patient`s annulus size [e.g. left ventricular failure, hemolysis, limited exercise tolerance], prediction of the prosthetic valve size preoperatively by use of cineangiogram is useful.

  • PDF

Subpectoral Relocation Method for Treating the Exposed Well Functioning Cardiac Pacemaker [Report of One Case] (피부괴사로 노출된 인공 심박동기 치험 1)

  • Park, Cheol-Ho;U, Jong-Su;Jo, Gwang-Hyeon
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.191-194
    • /
    • 1987
  • Exposure of the cardiac pacemaker is still a difficult problem associated with high morbidity. Grossly infected pacemaker systems had been required removal and insertion of a new system. It would highly desirable to develop a new method that could salvage an exposed well functioning unit because cardiac pacemaker is very expensive. We have experienced one patient with exposed well functioning cardiac pacemaker, which was relocated to contralateral subpectoral pocket and healed without complication. This relocation of the pacemaker to subpectoral pocket is less simple, expensive and should be considered as an alternative to complete replacement of unit.

  • PDF

Electrical Modelling of Nonlinear Blood-Gas Reaction (비선형 폐 가스 결합특성의 전기적 모델화)

  • 이준탁;정형환
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.175-182
    • /
    • 1991
  • A newly derived O$_2$ Saturation Model which can be adapted to the design and study of Artificial Lung and Blood Gas Calculator etc. is introduced on the basis of Electrical Equivalent Circuits. The presented 4 stage and 2 stage RC circuits have good correlatons with actual chemical reactions of Hemoglobin and Oxygen. However, from results of computer simulations, 2 stage equivalent model is more accurate than 4 stage and conventional O$_2$ saturation models.

  • PDF

Comparison of Repair and Replacement for Mitral Valve Regurgitation (승모판막폐쇄부전에 대한 외과적 치료: 승모판막재건술과 승모판막치환술의 비교)

  • 안지섭;최세영;박남희;유영선;이광숙
    • Journal of Chest Surgery
    • /
    • v.34 no.2
    • /
    • pp.118-124
    • /
    • 2001
  • 배경: 승모판막재건술이 승모판막치환술보다 술후 좌심실기능이 보다 향상될 수 있으며 또한 수술사망율과 인공판막에 관련된 합병즈인 혈전색전증, 심내막염 및 항응고제사용에 따른 출혈빈도는 낮다고 하였다. 방법: 1996년 1월부터 2000년 5월까지 승모판막폐쇄부전으로 진단된 환자 87례를 대상으로 재건술군 59례, 치환술군 28례로 나누어 비교분석하였다. 결과: 술전 환자들의 NYHA 기능분류, 흉부 X-선상 심흉곽의 비, 심초음파상 좌심실박출계수는 두 군간에 유의한 차이가 없었다. 원인질환은 양군에서 퇴행성 병변이 가장 많았다. 체외순환시간은 재건술군에서 유의하게 길었으나 수술사망은 양군에서 없었다. 술후 NYHA 기능분류, 흉부 X-선상 심흉곽의 비는 향상되었으나 두 군간에 차이가 없었으며 술후 좌심실박출계수는 두 군에서 감소되었으나 유의한 차이는 없었다. 결론: 이상의 결과로 승모판막폐쇄부전에 대하여 재건술이 치환술처럼 비교적 안전하게 시행될 수 있는 술식으로 사료된다.

  • PDF