Thermal Property of the Roof Green Unit System Using Artificial Lightweight Soil Recycled with Bottom Ash (바텀애시 재활용 인공토양 적용 옥상녹화 유니트 시스템의 열특성)

  • Yoo, Jong-Su;Lee, Jong-Chan;Oh, Chang-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.49-55
    • /
    • 2020
  • In this study, the surface temperature of the roof green system using ALSRBA(Artificial Lightweight Soil Recycled with Bottom Ash) was measured in each season and the thermal property of the ALSRBA was investigated. As a result, it was certified that ALSBRA has superior thermal property than the usual artificial soil. In addition, The daily temperature range in each season was measured to investigate the thermal isolation property of EUS(Existing Unit System) and DUS(Developed Unit System). The result showed that the thermal isolation effect of EUS was lower than that of SPSS(Site-Place-Soil System), but thermal isolation effect of DUS was similar to that of SPSS because DUS has continuous ALSBRA layer by removing unit barrier.

Assessment of Evaluation by Hybrid Waterproof-Roof Barrier Layer for Green System on Artificial Ground (인공지반 녹화시스템 활용을 위한 일체형 방수·방근 시트의 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.4
    • /
    • pp.391-396
    • /
    • 2015
  • The demands about eco friendly space are increased as buildings are denser in downtown, and green system on the roof and the artificial ground are widely being applied. The construction of green system applies a waterproof layer, a root barrier and a protection concrete layer. Assembly of these many layers leads to a long construction term, and cause many defects. This study is to evaluate one layer-hybrid sheet which gets waterproof and root barrier performance simultaneously, which is developed to use in the new green system. As results, the performances of physical properties, durability, waterproof and root barrier not only exceeded quality standards but also showed excellent durability. In addition, mock-up test would be proceed to certify long term performance.

Effects of Substrate Type, Soil Depth, and Drainage Type on the Growth of Sedum kamtschaticum in Extensive Green Roof Systems (저토심 옥상녹화 시스템에서 기린초의 생육에 대한 인공배지 종류, 토심, 그리고 배수 형태의 효과)

  • Huh, Keun-Young;Kim, In-Hye;Ryu, Nam-Hyong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.31 no.4
    • /
    • pp.90-100
    • /
    • 2003
  • 본 연구는 기존 건축물 옥상녹화에 이용 가능한 저토심 옥상녹화 시스템 을 연구하고 개발하고자 수행되었다. 연구목적을 달성하기위해서 시스템의 개념적 모델이 선행 연구로부터 유추되었고 개념적 모델로부터 실험을 위한 시스템들이 제안되었다. 건축물 옥상 위에 설치된 이 시스템들에서 기린초의 생육에 대하여 인공배지 종류, 토심, 그리고 배수 형태의 효과들이 2002년 4월 3일부터 10월 18일까지 연구되었다. 인공배지 종류는 단용과 혼용이고, 토심은 5cm, l0cm,그리고 15cm이며, 배수 형태는 저수$.$배수형과 배수형으로 하였다. 여기서, 인공배지 단용은 폐유리 미분 100에 발포제를 1∼2정도 첨가하고, 착색제를 1정도 첨가한 후, 6∼8$^{\circ}C$/min로 승온하여 750∼85$0^{\circ}C$의 온도에서 발포시킨 다공질 유리를 수냉식으로 급랭하고, 분쇄기로 이송하여 l0mm이하로 분쇄하고 입도를 조절하여 얻어진 다공질 유리 파쇄물과 수피를 부피 비 6:4로 혼합하여 조성된 것이며 인공배지 혼용은 인공배 지 단용에 양토(모래 46%, 미사 40%, 점토 14%)를 부피비 5:5로 혼합하여 조성된 것이다. 피복면적, 지상부와 지하부의 생체중과 건물중, 그리고 시각적 질을 조사하였다. 각 변수들은 던칸의 다중범위 검정으로 통계처리 하였으며 처리들간의 유의수준은 5%였다. 그리고 기존 건축물 옥상에 대한 과부하의 위험을 피하기 위해서 각 시스템의 중량이 평가되었다. 그 결과를 요약하면 다음과 같다. 실험기간 중에 피복면적에 대한 배수 형태의 효과는 유의성 있는 차이를 나타내지 않았다. 인공배지 혼용의 피복면적은 인공배지 단용의 것보다 통계적으로 유의성 있게 높았다. 토심 5cm처리의 피복면적은 나머지 처리들의 피복면적보다 통계적으로 유의성 있게 낮았다. 토심 l0cm처리와 토심 15cm처리는 통계적으로 유의성이 없는 것으로 나타났다. 지상부와 뿌리의 생체중 및 건물중과 시각적 질에 대한 처리들의 효과는 피복면적에 대한 것과 유사하거나 동일하였다. 결과적으로, 기린초의 생육은 인공배지 단용보다 인공배지 혼용에서 더 높았고, 토심 10∼15cm에서 더 높았으며, 배수 형태에서는 뚜렷한 차이를 나타내지 않았다. 이 결과를 토대로, 기존 건축물 옥상에 적용 가능한 시스템의 허용하중과 기린초의 생육을 동시에 고려해볼 때, 저토심 옥상녹화 시스템 은 인공배지 종류에서는 혼용이, 토심은 10cm, 그리고 배수형태는 배수형이 적합하다고 보았다. 제안된 조건으로 조성된 시스템은 인공배지가 포장용수량상태일 때 그 중량이 약 115kg/$m^2$정도로 나타났다.

Development of Experimental System for Green Roof System (옥상녹화 효율성 검증실험장비 개발)

  • Park, JaeRock;Kim, SaeBom;Cheon, JongHyeon;Kim, ByungSung;Shin, HyunSuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.495-495
    • /
    • 2017
  • 도시화는 불투수면의 증가를 야기 시켜 물순환 왜곡, 다양한 오염 물질의 유입으로 인한 비점오염물질 유출, 인공 배출열의 증가로 인한 도시열섬효과 등 다양한 문제를 유발한다. 이러한 수리수문학적 및 환경생태학적 문제를 저감하기 위하여 도시지역과 같은 개발 사업에서는 수환경을 가능한 자연 상태로 복원하는 저영향개발(Low Impact Development, LID)기법이 중요한 대안으로 제시되고 있다. LID기법 중 하나인 옥상녹화는 에너지 이용을 최소한으로 한 자연 녹음의 효과적인 이용을 도모하여 환경공생도시 조성과 식물을 매개로한 자연 순환 과정을 도시구조에 도입하여 순환 시스템 재생이 가능 하도록한다. 노지녹화는 두꺼운 자연 토양을 이용하는 반면 옥상녹화는 적재하중의 제약(옥상의 적재하중 조건은 $150{\sim}180kgf/m^2$이다. 비중이 1.6~1.8인 토양을 20cm 객토한 경우, 약 $320kgf/m^2 $이상의 적재하중이 되기에 식재기반의 경량화는 중요한 사안이다.)으로 인해 용적밀도가 작은 인공경량토양 또는 개량토양을 이용하며, 토양 두께도 얇게 설정된다. 또한 토양의 두께는 식물의 크기와 종류 및 토양의 조성에 따라 다르기에 적재하중 조건을 고려한 적절한 토양과 식재 식물의 크기와 종류 결정은 중요하다. 이에 본 연구에서는 옥상녹화식생에 대한 평가와 이에 대한 시험 프로세스가 가능한 실험 장치를 개발하였다. 옥상녹화 효율성 검증실험장비는 1m*1m*0.6m 아크릴 재질의 녹화셀로 경사조절이 가능하도록 설계하여 경사변화에 따른 유출, 침투, 증발산량의 탄성도 모의 평가를 할 수 있다. 또한 4점식 형태의 로드셀을 이용하여 녹화셀에서 발생하는 증발산량을 측정하고 관측된 증발산량은 RS-232c 이상의 통신프로토콜을 사용하여 주기적인 관측치의 송수신이 가능하며 주기적 자료송수신 외에도 옥상 녹화셀의 측면에 하중 표시기를 설치하여 관측이 가능하다. 또한 저면에 바퀴설치를 통하여 이동 실험이 용이하며 현재 부산대학교 양산캠퍼스 한국 GI&LID 실증단지 연구센터 내 옥상녹화 실험장에 옥상녹화 효율성 검증 실험 장비를 설치하여 자연 혹은 인공강우를 통한 유출, 침투, 증발산량의 시험계측을 실시중이다. 이러한 옥상녹화 효율성 검증실험장비는 최대 하중 2,000kg, 측정해상도 0.02kg 이상을 허용하는 로드셀과 녹화셀을 이용하여 하중을 고려한 식생의 종류에 따른 평가가 가능하므로 최적 식재기반 단면구조 개발에 이용될 수 있을 것이다. 또한 토양 함수량 변화 측정으로 옥상녹화에 이용되는 다양한 종류의 식물의 염분에 대한 저항성과 식물의 성장능력을 평가하여 녹화공간에 따른 옥상녹화에 사용할 식생을 결정할 수 있다.

  • PDF

Performance Evaluation for the Application of Roof Green Box Unit System Combined with Engineering P.E.Waterproof and Root Penetration Sheet (엔지니어링 PE방수.방근시트가 결합된 박스 유닛형 옥상 녹화 시스템 적용을 위한 성능평가)

  • Oh, Chang-Won;Hong, Jong-Chul;Park, Ki-Bong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.125-131
    • /
    • 2016
  • According to the increment of urban buildings, the demand of eco-environment space will be also increased. Therefore, the artificial ground green system on a roof will be supplied gradually. In this study, the concept of simplification, unification and prefabrication was widely applied to supply green system. Consequently, the box unit system with a continuous soil layer was developed, and adhesive property, wind resistance and insulation property of this system were evaluated for site application. As a results of adhesive property and wind resistance test, comparing with design wind pressure and wind velocity, this system was safe at the height of 100m building located in urban. In addition, results of temperature measurement for 120 days showed 17% higher insulation property at daytime and 45% higher insulation property at night than normal box unit system owing to continuous soil layer.

Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System (인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구)

  • Park, Chang-Hwa;Oh, Sang-Keun;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.2
    • /
    • pp.189-199
    • /
    • 2011
  • Installation of a proper root barrier in a green roof system is very important in order to protect the concrete slab of roof and the root penetration in the waterproofing layer. To select the proper root barrier materials and methods, it is necessary to understand the environmental conditions affecting the waterproofing-root barrier system in green roof construction site. Therefore, we suggested as the environmental performance indexes four kinds of performance requirements; root penetration, chemical attack by chemical agent or fertilizer, load impact by soil depth and size of plant, and water pressure. The related four test methods were suggested for the inspection of these performance indexes. In this research, we could suggest for kinds of test methods as standard test methods to evaluate the environmental performance of waterproofing-root barrier for greening roof system.

Economics and Ground Cover Growth Characteristics of a New Method of Shallow Soil Artificial Foundation Planting (저토심 인공지반 녹화공법의 경제성 및 도입 가능한 지피식물의 생육특성)

  • Choi, Jin-Woo;Kim, Hag-Kee;Lee, Kyong-Jae;Kang, Hyun-Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.5
    • /
    • pp.98-108
    • /
    • 2009
  • The purpose of this study is to analyze the characteristics of limited methods, economics and breeding appropriateness of native and imported ground cover plants in the methodology of a shallow soil rooftop garden. The new shallow soil rooftop gardening method uses a total of 13cm in soil thickness, including 4.5cm of top soil on a 7.5cm rock-wool-mat stacked onto a 1cm roll-type-draining plate. The total construction cost for each method of soil level within the design price standard for SEDUM BLOCK is 89,433won/$m^2$, and for DAKU is 92,550won/$m^2$. By comparing those two methods, the construction cost of the shallow soil artificial foundation methodology is 45,000won/$m^2$; this shows the new method is 50% less expensive than the existing method of shallow soil rooftop gardening. The experiment was executed on the rooftop of the Korean National Housing Corporation to ensure validity of the shallow soil artificial foundation planting, and the sample plants which were imported and grown now in native covering. A list investigating the growing plants was made of the cover rate in each plant class, both while alive and the dry plant weight. The native ground cover plants, Sedum kamtschaticum, Sedum middendorffianum, Allium senescens, Sedum sarmentosum, Aquilegia buergariana, and Caryopteris incana increased the cover rate, live weight and dry weight in the shallow soil artificial foundation method. Among the imported cover plants, Sedum sprium and Sedum reflexum, the cover rate increased and growth conditions improved. However, some species needed weed maintenance. After examination with the less expensive shallow soil artificial foundation method and growth analysis, it was found that rooftop gardens are a low-cost option and the growth of plants is great. This result shows the new method can contribute to the proliferation of rooftop gardens in urban settings.

Hydrological performance analysis of green wall through indoor experiment (실내실험을 통한 벽면녹화에 따른 물순환 효과 분석)

  • Ji Hyun Moon;Jae Rock Park;Soon Chul Kwon;Jae Moon Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.302-302
    • /
    • 2023
  • 최근 도시의 왜곡된 물순환 문제를 해결하기 위해서 저영향개발(Low Impact Development, LID) 기법을 적극적으로 도입하고 있다. 저영향개발은 자연의 침투, 증발산, 여과 등의 자연기작을 모방하여 강우유출수를 침투 및 저류시키는 기법으로 물순환 체계를 회복시킬 수 있다. 저영향개발 기법의 하나인 벽면녹화는 건축물이나 기반 시설물의 벽면과 같은 인공지반에 기반을 조성하고 식물을 식재하는 시설로 짧은 시간에 녹지 면적을 만들 수 있다. 또한, 건축물로 인해 생겨난 수직적인 면을 녹지로 활용할 수 있어 도시에 매우 특화된 시설이다. 본 연구는 벽면녹화의 저영향개발 시설로서의 성능을 확인하기 위해 실내 실험을 진행하여 강우유출수 저감효과 및 지체시간 지연효과를 확인하였다. 강우유출수 저감효과는 유입량 대비 저류량을 기준으로 유출저감률을 산정하여 분석하였으며, 총 유출시간을 측정하여 지연효과를 판단하였다. 벽면녹화 현장실험 대상지는 경상남도 양산시 물금읍 부산대학교 양산캠퍼스에 위치한 한국 녹색인프라저영향개발센터이며, 실내에 플랜터형 벽면녹화 시스템을 적용하였다. 부산시 금정구 2012년~2021년의 강수량을 사용해 백분위수 강우사상을 기준으로 30, 50, 70mm/hr의 강우 시나리오를 선정하였다. 물순환 효과를 판단하기 위해 불투수면을 대조군으로 설정하여 불투수면의 유출이 종료되는 시점까지 지표면 유출을 모니터링 하였다. 그 결과, 30, 50, 70mm/hr 시나리오별 유출률은 91.76%, 92.18%, 94.54%로 불투수면과 대비하여 유출이 적게 발생하였으며 총 유출시간은 불투수면대비 47분, 88분, 58분 증가하여 지연효과가 있음을 확인하였다. 본 연구는 실험을 통해 벽면녹화의 수문학적 성능을 분석하고자 유출량 저감효과와 지연효과를 확인하였다. 추후 다양한 강우 시나리오와 제원에 따라 실험이 수행된다면 더 정확히 벽면녹화의 물순환 효과를 확인할 수 있을 것이다.

  • PDF

Assessment of Plant Growth and Soil Properties of Extensive Green Roof System for Rhododendron indicum Sweet (영산홍을 이용한 저관리 옥상녹화 시스템의 식물생육 및 토양특성 평가)

  • Kim, In-Hea;Huh, Keun-Young;Shin, Hyeon-Cheol;Park, Nam-Chang
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.1057-1065
    • /
    • 2010
  • Recent urban concerns over environmental problems have furthered interest in green roof system. Plant growth and load bearing capacity of an underlying roof are key factors to determine an optimal system. This study was carried out to develop an optimal extensive green roof system for shrubs assessing the effects of substrate type and soil depth on the growth of $Rhododendron$ $indicum$ Sweet. in the experimental systems with different soil types and depths from 2001 to 2008. Substrate types of perlite alone and blended with sandy loam (v/v, 1:1) were used on the experimental systems with depths of 30 cm, 45 cm, and 60 cm. The survival rate of the plants on the perlite alone + 45 cm soil depth system (RS-A-45) was 100% during the experimental period, while those on the perlite alone + 30 cm soil depth system (RS-A-30) and perlite blended + 60 cm soil depth system (RS-B-60) showed 33% and 67%, respectively, in 2008. The overall plant growth and soil properties of RS-A-45 were superior to the others. At 8 years after installation, the total weight of RS-A-45 including plant fresh weight was about $376.6kg{\cdot}m^{-2}$ in field capacity indicating RS-A-45 can be optimal extensive and light weight green roof system.