Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers (골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.833-844
    • /
    • 2018
  • Dual energy X-ray absorptiometry is mainly used as an X-ray test method. For equipment manufactured GE and Hologic, cross-calibration analyses (CCA) of machines from the same manufacturer and between units from different manufacturers have been conducted, but the CCA of equipment manufactured in Korea are inadequate. Through CCA, we present a formula of the intersections between the Korean medical equipment company (KEC) with GE and Hologic manufactured DXA, and among the KEC DXA. The CCA was conducted for the European Spine Phantom on DXA from four KEC and three global medical equipment company (GEC) manufacturers. We compared bone mineral density (BMD) values and calculated the CCA equation by linear regression analysis. The standard-deviations (SD) of the BMD values were highest for the Dexxum T for the low, medium, and high spine, which were 0.030, 0.029, and 0.037, respectively. The smallest SD in the low and medium vertebrae were 0.005 and 0.004 for the Horizon Ci, respectively, and 0.005 for the Osteo Pro Max in the high vertebrae. Based on the intersection equations of the KEC DXA established in this study, CCA of various KEC DXA should be established for more accurate follow-up of BMD tests in clinical environments.

Bone Region Extraction by Dual Energy X-ray Absorbtion Image Decomposition (Dual Energy X-ray 흡수 영상의 분해를 통한 뼈 영역 추출)

  • Kwon, Ju-Won;Cho, Sun-Il;Ahn, Young-Bok;Ro, Yong-Man
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.9
    • /
    • pp.1233-1241
    • /
    • 2009
  • Over the 50 percents of women who are older than 45 years have osteoporosis. Because people hardly recognize this disease by themselves, the researches that measure bone mineral density have been doing widely to detect osteoporosis in the early stage. The most widely used methods for bone mineral density measurement are based on the X-ray imaging. Among them, DEXA(Dual-energy X-ray Absorptiometry) imaging is one of the important methods in bone mineral density measurement. DEXA images are useful methods to increase diagnosis efficiency by reducing anatomic noise as two images obtained from two different energy levels. However, it has some problems to a calibration parameter determined by the heuristic method for bone extraction. In this paper, we propose the method to extract bone in DEXA image using calibration parameter based on anatomic attenuation coefficient. The experimental results reveal that the proposed method is effective.

  • PDF

Quantitative Analysis of Bone Mineral Measurements in Different Types of Dual-energy Absorptiometry Systems: Comparison of CT vs DEXA (이중 에너지 조사 방식의 장비별 골밀도 측정의 정량적 비교 분석: CT vs DEXA 비교)

  • Kim, Myeong Seong
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.311-316
    • /
    • 2017
  • Generally assessing bone mineral density (BMD) were performed on dual energy X-ray absorptiometry (DEXA) the same as dual energy CT (DECT) with a rapid-kVp switching. The purpose of this study is to compare the different of BMD value between DEXA and DECT method, and evaluate usefulness of DECT method. Using scanner for BMD measurements were GE, Healthcare Discovery 750 HD for DECT and Hologic QDR 4500W for DEXA. For compare BMD value in each method, scanned lumbar spine phantom and subjects visiting Korean National Cancer Center from April 2015 to December 2015, records of 50 patients. This study was approved by the Institutional Review Board. The mean BMD value measures for spine phantom and for subjects in each scanners presented strong correlation (r=0.948 with p<0.05 for phantom; r=0.635 with p<0.05 and Kendall's tau $({\tau})=0.46$ with p<0.05 for subjects) and linear relationship between DECT and conventional DEXA. DECT technique for BMD measurement will provide a very useful methodology without additional radiation dose.

Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry (대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교)

  • Hyo Jeong Lee;Ji Young Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.173-181
    • /
    • 2021
  • Purpose To evaluate the ability of the Hounsfield unit (HU) measurement of the femoral neck during multidetector computed tomography (MDCT) for assessing osteoporosis compared with dual-energy X-ray absorptiometry (DXA). Materials and Methods Forty-two patients with femoral neck fractures who underwent MDCT and DXA from July to December 2016 were included in this study. HU measurements were made of the cancellous portions of the normal contralateral femoral neck on MDCT. Bone mineral density (BMD) and T-scores were obtained at the femur DXA. Correlations of HU values with BMD and T-scores were analyzed using Spearman's correlation test. Results The mean BMD and T-score of the femoral neck were 0.650 g/cm2 and -2.4, respectively. The mean HU values for the normal, osteopenia, and osteoporosis groups were 131.9, 98.9, and 41.3, respectively. HU values at the femoral neck were positively correlated with BMD (r2 = 0.670; p < 0.001) and T-scores (r2 = 0.676; p < 0.001). Conclusion The HU values of the femoral neck on MDCT are significantly correlated with BMD and T-scores of femur DXA. The HU values may serve as a diagnostic tool for the screening of regional bone quality when MDCT is performed for other reasons.

Comparative Analysis of Bone Mineral Contents with Dual-Energy Quantitative Computed Tomography (이중에너지광자선의 전산화단층촬영술을 이용한 정량적 골무기물함량의 비교분석)

  • Choi, Tae-Jin;Yoon, Seon-Min;Kim, Ok-Bae;Lee, Sung-Moon;Suh, Soo-Jhi
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.153-158
    • /
    • 1997
  • Purpose : The Dual-Energy Quantitative Computed Tomography(DEQCT) was compared with bone equivalent $K_2HPO_4$ standard solution and ash weight of animal cadaveric trabecular bone in the measurement of bone mineral contents(BMC). Method and Materials : The attenuation coefficient of tissues highly depends on the radiation energy density and effective atomic number of composition, The bone mineral content of DEQCT in this experiments was determined from empirical constants and mass attenuation coefficients of bone,fat and soft tissue equivalent solution in two photon spectra. In this experiments, the BMC of DEQCT with 80 and $120kV_p$ X rays was compared to ash weight of animal trabecular bone. Results : We obtained the mass attenuation coefficient of 0.2409 0.5608 and 0.2206 in $80kV_p$, and 0.2046, 0.3273 and $0.1971cm^2/g$ in $120kV_p$ X-ray spectra for water bone and fat equivalent materials, respectively. The BMC with DEQCT was acomplished with empirical constants $K_1=0.3232,\;K_2$=0.2450 and mass attenuation coefficients has very closed to ash weight of animal trabecular bone The BMC of empirical DEQCT and that of manufacturing DEQCT were correlated with ash weight as a correlation r= 0.998 and r= 0.996, respectively. Conclusion : The BMC of empirical DEQCT using the experimental mass attenuation coefficients and that of manufacture have showed very close to ash weight of animal trabecular bone.

  • PDF

The Analysis of BMD in Forearm and Hip Joint with DEXA (DEXA에 의한 아래팔과 엉덩관절의 골밀도 분석)

  • Lee, Kwang-Sung;Park, Ui-Su;Jeon, Min-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.168-173
    • /
    • 2015
  • Use of forearm and hip joint bone density scan and find the clinical usefulness of the results that can be inferred as a result of any other region sites injured by a correction factor which if One part up. Groups of 60 patients, 10 patients by age 20-70 were composed of patients measured with the forearm and lumbar spine bone mineral density T-score and Z-score of the survey for each of the three factors that it was Find the correction factor to obtain the relationship. Bone mineral density of the correlation coefficient R = 0.8 correction factor is Y = 1.341X + 0.146. T-score of correlation coefficient R = 0.804 and the correction factor Y = 0.565X - 0.327 is Z-score of the correlation coefficient R = 0.637 correction factor Y = 0.539X - 0.225. It is regarded that there will be a clinical availability which can analogize the result of a part by using the result of the other part. It will be able to determine an auxiliary role in the clinical diagnosis. Correction factor to the equation Y = 1.341X + 0.146 is recommended.

Assessment of Osteoporosis Based on Changes in SNR and ADC Values on MR Diffusion Weighted Images (확산강조영상에서 신호대 잡음비, 현성 확산 계수 변화에 따른 골다공증 평가)

  • Cho, Jae-Hwan;Kim, Yeong-Soo
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.70-77
    • /
    • 2010
  • This study tested how S/N (Signal to Noise Ratio) ratios and ADC (apparent diffusion coefficient) values vary with different T-scores in a group of patients with osteoporosis. Based on DEXA (Dual Energy X-ray Absorptiometry) T-scores for L1.L4 for two groups of subjects consisting of 30 healthy people without osteoporosis and 30 patients who came for treatment of waist (lumbar or low back) pain and were suspected to have osteoporosis as judged from the simple X-ray findings, this study classified every spine into two groups of osteoporosis and osteopenia. Signal intensity measurements were made in the four regions of L1 to L4 on diffusion-weighted MR images obtained using 1.5T MR scanner, while ADC measurements were obtained from ADC map images. As an approach for quantitative analysis, the comparison of the variances in S/N ratios and ADC values for varying T-scores in the selected regions of interest was carried out based on averaged T-scores, S/N ratios, and ADC values. Also, the variances in S/N ratios and ADC values for each of the groups of osteoporosis and osteopenia, which were classified into by T-scores, were compared. For qualitative analysis, a careful naked eye examination of signal intensity differences in the area of L4 was made on T1-weighted sagittal images for each of the healthy (normal), osteopenia, and osteoporosis groups. In the qualitative analysis, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the S/N ratios on diffusion-weighted MR images also decreased, with the greatest decrease in the S/N ratio found in the osteoporosis group. Additionally, among the three groups, the lowest S/N ratio was found in the osteoporosis group. With respect to ADC map, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the ADC values on diffusion-weighted MR images also decreased, with the greatest decrease in the ADC values found in the osteoporosis group. Additionally, among the three groups, the lowest ADC value was found in the osteoporosis group. On the other hand, in the qualitative analysis, the osteoporosis group showed the highest signal intensity. Additionally, among the three groups, the lowest signal intensity was found in the healthy (normal) group. It was found that as osteoporosis progressed, S/N ratio and ADC decreased, whereas signal intensity increased on T1-weighted images. Also, in diagnosing osteoporosis, MRI tests turned out to be (more) effective.

Change in the Measured Value at 99mTc-MDP Administration before and after Bone Density Measurement using the Dual Energy X-ray Absorptiometry (이중에너지 X선 흡수법을 이용한 골밀도 측정시 99mTc-MDP 투여 전·후 측정값의 변화)

  • Kang, Yong-Gil;Won, Do-Yeon;Jung, Hong-Moon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • Measurement of bone marrow measurements may occur if bone marrow examination performed with bone marrow examination (bone marrow examination) and bone density (bone scan) are performed together recently. Thus, it was examined in clinical aspects that $^{99m}Tc-MDP$ compounds were affected by bone mineral density measurements. The average age of the participants in the experiment was $35.17{\pm}9.45$ and the patient fractures of the lumbar vertebrae that could affect the metabolic disease and bone density measurements affecting the metabolic disease of the 17 subjects. 6 patients with normal bone mineral density T-scores>-1.0 in 12 patients were analyzed before and after the administration of $^{99m}Tc-MDP$. In the lumbar spine, the average of $0.975{\pm}0.084g/cm^2$ and $0.966{\pm}0.078g/cm^2$ were increased by $0.009g/cm^2$. respectively In the right proximal femur, mean values were $0.909{\pm}0.078g/cm^2$ and $0.913{\pm}0.086g/cm^2$. In the right proximal thigh, mean values were $0.909{\pm}0.078g/cm^2$ and $0.913{\pm}0.08 g/cm^2$, respectively, which decreased by $0.004g/cm^2$. In the left side proximal femur, mean $0.887{\pm}0.099g/cm^2$ and $0.881{\pm}0.103g/cm^2$, respectively, increased by $0.007g/cm^2$. Therefore, the BMD changes in the lumbar region were larger than that in the proximal thigh. In addition, $^{99m}Tc-MDP$ did not affect the BMD. And a bone scan test using a technetium-labeled compound emitting a gamma-ray energy of 140 keV did not significantly affect bone density measurements. However, if the nuclear medical examination and the osteoporosis test are to be performed together, the examination should be carried out at intervals considering the exposures of the patient.

The Position for Measuring BMD of the Distal Radius and The Study of the Correlation Between the Distal Radius and Lumba (원위 요골 골밀도의 측정 자세 및 요추 골밀도의 상관관계에 관한 연구)

  • Han, Man-Seok;Jeon, Chul-Min;Kim, Jong-Jin;Seo, Seon-Youl;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • The aim of this study was to evaluate the change of bone mineral density according to distal radius rotation and the correlations of the lowest BMD measured by DXA at the lumba versus distal radius. The eleven males were projected distal radius by DR X-ray and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 21 males. The healthy 11 and 21 volunteers without any history of operations, anomalies, or trauma were enrolled. The experiment was performed by two methods. First, The DR X-ray was measured distal radius of 11 males in pronation and supination with three, six and nine degrees, including a neutral position. The ROI was measured by the m-view program on the PACS monitor. Second, The DXA was measured distal radius of 21 males in pronation and supination with five and ten degrees, including a neutral position to evaluate the changes of BMD according to the rotation. A correlation of the BMD in the distal radius with BMD that lumbar spine was performed, along with analysis of the data by SPSS 12.0v. The mean rotation angle of the distal radius about eleven males DR X-ray measured $7^{\circ}$ of pronation (82%, n = 9), $6^{\circ}$ of supination and $0^{\circ}$ of neutral of (9%, n = 1), The total average rotation angle in 11 male was $5.1^{\circ}$ of pronation. The rotation angle of the distal radius about twenty one males on DXA measured $7.2^{\circ}$ of pronation (43%, n = 9), $7^{\circ}$ of supination (24%, n = 5), and $0^{\circ}$ of neutral (33%, n = 7), The total average rotation angle in 21 people was $4.1^{\circ}$ of pronation. The correlation of the analysis of lumba and distal radius were r = 3.0, p = 0.18. consequently, The correlation was not significance. Because BMD of lumba was not coverd for BMD of the distal radius, with a neutral position, Pronation is needed for BMD in the distal radius with the rotation angle measuring at the lowest BMD. the rotation angle about five degrees of pronation of the distal radius is recommended.