• Title/Summary/Keyword: 이중에너지

Search Result 995, Processing Time 0.03 seconds

Study on Optimum Contrast Medium Quantity during Abdominal CT using Dual Energy Technique (복부 CT 검사 시 이중에너지 기법을 통한 적정한 조영제 양에 관한 연구)

  • Kang, Min;Choi, Namgil;Han, Jaebok;Kim, Wook;Jang, Yeongill;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2015
  • The purpose of this study is finding optimum contrast medium quantity during abdominal CT using dual energy technique. The study subjects are 30 patients who had received general single energy abdominal CT and received double energy technique follow-up abdominal CT. dual energy technique abdominal CT images were obtained after setting contrast medium quantities at 30%, 40%, 50%, 60% and 70% of contrast medium quantity at the time of single energy technique. Then the contrast enhancement (Hounsfield Unit; HU) was estimated by setting-up the regions of interest at aorta, inferior vena cava, hepatic portal vein and hepatic parenchymal. The obtained values were compared to the values of the same parts measured during single energy technique abdominal CT. The results of the study were as following. The 60% set up group had HU in aorta : $210.80{\pm}13.609$, IVC : $190.40{\pm}25.215$, hepatic portal vein : $198.40{\pm}21.232$ and hepatic parenchymal : $119.20{\pm}7.98$, The single energy abdomianl CT images had HU in aorta : $205.40{\pm}16.426$, IVC : $188.20{\pm}21.476$, hepatic portal vein : $195.40{\pm}22.744$ and hepatic parenchymal : $121.00{\pm}6.595$. Therefore, it is possible to obtain contrast enhancement by dual energy technique abdominal CT similar to the same by single energy technique abdominal CT by setting-up the quantity of contrast medium at 60% of contrast medium at the time of single energy technique abdominal CT. Based on the result of this study, it is possible to decrease existing quantity of contrast medium by _% and the injection velocity can be also decreased. Accordingly, it is believed that the result of study would be quite useful for patients who have renal function disorder, weak vein or side effect of contrast medium in the past.

Evaluation of Radiation Dose for Dual Energy CBCT Using Multi-Grid Device (에너지 변조 필터를 이용한 이중 에너지 콘빔 CT의 선량 평가)

  • Ju, Eun Bin;Ahn, So Hyun;Cho, Sam Ju;Keum, Ki Chang;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • The paper discusses radiation dose of dual energy CT on which copper modulation layer, is mounted in order to improve diagnostic performance of the dual energy CT. The radiation dose is estimated using MCNPX and its results are compared with that of the conventional dual energy CT system. CT X-ray spectra of 80 and 120 kVp, which are usually used for thorax, abdominal, head, and neck CT scans, were generated by the SPEC78 code and were used for the source specification 'SDEF' card for MCNPX dose modeling. The copper modulation layer was located 20 cm away from a source covering half of the X-ray window. The radiation dose was measured as changing its thickness from 0.5 to 2.0 mm at intervals of 0.5 mm. Since the MCNPX tally provides only normalized values to a single particle, the dose conversion coefficients of F6 tally for the modulation layer-based dual energy CBCT should be calculated for matching the modeling results into the actual dose. The dose conversion coefficient is $7.2*10^4cGy/output$ that is obtained from dose calibration curve between F6 tally and experimental results in which GAFCHORMIC EBT3 films were exposed by an already known source. Consequently, the dose of the modulation layer-based dual energy cone beam CT is 33~40% less than that of the single energy CT system. On the basis of the results, it is considered that scattered dose produced by the copper modulation layer is very small. It shows that the modulation layer-based dual energy CBCT system can effectively reduce radiation dose, which is the major disadvantage of established dual energy CT.

Study on Performance Evaluation and Efficiency Comparison for Solar Collector with Thermosyphon Tube-type (태양열집열기의 성능평가 및 열사이폰관형 집열기의 효율 비교 연구)

  • Sim, Han-Sub;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.175-182
    • /
    • 2014
  • The use of solar energy among renewable energy tends to increase because of infinity and cleanness of resources. Even though the consumption rate of solar energy in our country is still low, however, in recent years, the research for solar energy have been widely conducted due to policy support of government. This study was performed to make the system of performance test for solar collector and to investigate thermal efficiency for solar collector with thermosyphon tube-type. As a result, in case of indoors measurement using halogen lamp, thermal efficiency for solar collector with thermosyphon tube-type was increased about 15~22% after 120 minutes compared with that of solar collector with double evacuated tube-type. In addition, in case of outdoors measurement, thermal efficiency of thermosyphon tube-type was showed maximum about 46% higher than double evacuated tube-type.

A Study on Rescue Technique and Safe Tow of Damaged Ship (2) - Failure Mechanisms of Collision and Grounding of Double Hull Tanker - (손상된 선박의 구난 기술 및 안전 예항에 관한 연구 (2) - 이중선체 유조선의 충돌 및 좌초에 의한 손상역학거동 -)

  • Lee Sang-Gab;Choi Kyung-Sik;Shon Kyoung-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.1 no.2
    • /
    • pp.82-95
    • /
    • 1998
  • In this paper, two series of numerical simulations are performed using LS/DYNA3D: The first series of numerical simulations are collision events between a 310,000 DWT double hull VLCC (struck ship) and two 35,000 and 105,000 DWT tankers (striking ships). Collisions are assumed to occur at the middle of the VLCC with the striking ships moving at right angle to the YLCC centerline. The second ones, grounding accidents of two 40,000 DWT Conventional and Advanced Double Hull lanker bottom structures, CONV/PD328 and ADH/PD328 models. The overall objective of this study is to understand the structural failure and energy absorbing mechanisms during collision and grounding events for double hull tanker side and bottom structures, which lead to the initiation of inner shell rupture and cause the kinetic energy dissipation to bring the ship to a stop. These numerical simulations will contribute to the estimation of damage extents of collision and grounding accidents and the future improvements in lanker safety at the design stage.

  • PDF

A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation (가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터)

  • Song, Seung-Ho;Sim, Dong-Joon;Jeong, Byoung-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.349-360
    • /
    • 2006
  • Controller for doubly-fed induction-type wind generation system should be designed with mechanical power on blade. The controller in this paper consists of upper level controller and lower level controller. The upper level controller determines operating modes according to mechanical input power and calculates proper reference values. There are 4 operating modes - minimum speed control, variable torque control, torque limit control and idle mode. The lower level controller performs current regulated PWM control of rotor-side converter and grid-side inverter. A wind turbine simulator is implemented using doubly-fed induction-type generator and DSP based back-to-back converter to verify the performance of designed controller experimentally.

A Study on the Performance of Blind type Double-Skin Facade System with PV modules (PV 모듈을 부착한 블라인드형 이중외피 시스템의 성능에 관한 연구)

  • Jo, Hye-Jin;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2005
  • The present society have been polluted the earth environment by the rapid industrial growth. So, the meaning of sustainable development is doing more important. Therefore the technology skills of sustainable architecture techniques have been studied many-side of energy as like energy saving and substitutive energy. But, See the studies until now, there have been just one system either energy saving or substitutive energy. So, the paper studies about energy saving system with substitutive energy system(the double-skin facade system with PV modules) and presents the performance of system through the analysis of reduction of the energy load, the solar radiation on the slope angle of PV module, the blind effect in system.

The Examination of Pre-Menopause Women's Bone Mineral Density and Its Related Factors by Using the Dual-Energy X-Ray Absorptionmetry (이중에너지 X선 흡수계측법을 이용한 폐경 전 여성의 골감소증 관련요인)

  • Yeo, Jin-Dong;Jeon, Byeong-Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.27-35
    • /
    • 2011
  • The purpose of this study is to examine factors that affect the bone mineral density of pre-menopause women by using the dual energy x-ray absorptionmetry, ultimately contributing to preventing women's osteoporosis that tends to be aggravated since menopause. Out of the subjects, 20.2% were suffering osteopenia. Age was found most important in estimating the level of bone mineral density. Meanwhile, the older women were, the significantly lower their bone mineral density was. It was found that taking exercise has a more positive effect on boss mineral density than not taking. Exercising in a suitable amount was helping women keep their bone mineral density better. Preferring meat to vegetarian diets were significantly affecting women's bone mineral density. Meanwhile, it was found that the shorter menstrual cycle is, the significantly lower bone mineral density is. A multi=regression analysis of bone mineral density and its related factors showed that the older women were, the significantly lower their bone mineral density was. In other words, age was found as the most risk factor of osteoporosis.

A Study on the Design Technique for Energy Performance Indicators of Existing Office Buildings (기존 오피스건물 에너지성능지표에 따른 설계기법 연구)

  • Jung, Hyungtae;Lee, You Na;Kim, Insoo;Ahn, Jong-Wook
    • Journal of Energy Engineering
    • /
    • v.27 no.3
    • /
    • pp.28-35
    • /
    • 2018
  • Guidelines and institutional support for buildings are being promoted around the world as measures for environmental pollution and energy conservation. In Korea, standards are prepared according to the energy saving design standards of new buildings as amended in 2013.09.01 and the zero energy building for new buildings mandatory process is being prepared from the recommendations. Nevertheless, the government's binding power on smaller buildings is insufficient. Energy savings were analyzed for the recently constructed office buildings (application of external insulation technique) and propose a dual envelope techniques were proposed for energy reduction.