• Title/Summary/Keyword: 이종질량

Search Result 98, Processing Time 0.035 seconds

The Relationship of the LV Systolic Function, the LV Dimension and the LV Mass to QT Dispersion in Stable Angina Patients who are with or without Significant Coronary Stenosis (안정성협심증 환자에서 저명한 관상동맥 협착 유무와 좌심실 수축기능, 용적, 질량과 QT Dispersion 간의 관계)

  • Kwon, Jong-Bum;Yoon, Hee-Jeoung;Jin, Seung-Won;Her, Sung-Ho;Kim, Hyung-Doo;Kim, Kyung-Soo;Lee, Jong-Ho;Park, Khun
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.439-446
    • /
    • 2008
  • Background: The aim of this study was to investigate the relationship of the left ventricular (LV) systolic function, the LV dimension and the LV mass with the QT dispersion in patients with stable angina, and we also wanted to compare this relationship between patients with and without significant coronary stenosis on coronary angiography. Material and Method: 174 patients complained of typical angina and they had no associated ST segment or cardiac enzyme abnormalities. The patients were divided into 2 groups based on the results of coronary angiography: the patients with angiographic coronary stenosis ${\geq}50%$ made up group I (n=101), and the patients with angiographic coronary stenosis <50% made up group II (n=73). An echocardiogram for assessing the LV ejection fraction (EF), the LV dimension and the LV mass and a 12.lead electrocardiogram for assessing the QT dispersion were performed before the coronary angiography. Result: The QT dispersion was significantly greater in group I than that in group II (39.8 ms vs. 33.3 ms; p<0.05). For all the patients, all the parameters of LV dimension and LV mass had statistically positive correlation to the QT dispersion, but the LV mass was the only independently significant parameter that was correlated with the increased QT dispersion (p<0.05). For group I, none of the echocardiographic parameters had significant correlation with the QT dispersion. However, the LV dimension and LV mass had significantly positive correlation with the QT dispersion, and the LV mass was also the only independently significant parameter that was correlated with increased QT dispersion in group II (p<0.05). Conclusion: Our study demonstrated a significantly positive correlation of the QT dispersion to the LV dimension and the LV mass in patients with stable angina. These findings are present only in patients without significant coronary stenosis.

Relationship between Systemic Inflammatory Marker, Oxidative Stress and Body Mass Index in Stable COPD Patient (안정된 만성폐쇄성폐질환 환자에서 신체질량지수와 전신 염증인자, 산화 스트레스와의 관련성)

  • Ham, Hyun Seok;Lee, Hae Young;Lee, Seung Jun;Cho, Yu Ji;Jeong, Yi Young;Kim, Ho Cheol;Ham, Jong Ryeal;Park, Chan Hoo;Lee, Jong Deok;Sohn, Hyun Joon;Youn, Hee Shang;Hwang, Young Sil
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.4
    • /
    • pp.330-338
    • /
    • 2006
  • Background: The main factors associated with weight loss in patients with COPD are not well known. Since chronic inflammation and oxidative stress play a major pathogenic role in COPD, these factors may be responsible for the patients' weight loss. Therefore, this study measured the body mass index (BMI) in COPD patients and evaluated the variables, such as systemic inflammatory marker, oxidative stress and lung function, that correlate with the BMI. Method: The stable COPD patients (M:F=49:4, mean age=$68.25{\pm}6.32$) were divided into the lower (<18.5), normal (18.5-25) and higher (>25) BMI group. The severity of the airway obstruction was evaluated by measuring the $FEV_1$. The serum IL-6 and TNF-$\alpha$ levels were measured to determine the degree of systemic inflammation, and the carbonyl protein and 8-iso-prostaglandin $F_2{\alpha}$ level was measured to determine the level of oxidative stress. Each value in the COPD patients and normal control was compared with the BMI. Results: 1) Serum 8-iso-prostaglandin $F_2{\alpha}$ in COPD patients was significantly higher ($456.08{\pm}574.12pg/ml$) than that in normal control ($264.74{\pm}143.15pg/ml$) (p<0.05). However, there were no significant differences in the serum IL-6, TNF-$\alpha$, carbonyl protein between the COPD patients and normal controls. 2). In the COPD patients, the $FEV_1$ of the lower BMI group was significantly lower ($0.93{\pm}0.25L$) than that of the normal BMI ($1.34{\pm}0.52L$) and higher BMI groups ($1.72{\pm}0.41L$) (p<0.05). The lower $FEV_1$ was significantly associated with a lower BMI in COPD patients (p=0.002, r=0.42). The BMI of very severe COPD patients was significantly lower ($19.8{\pm}2.57$) than that of the patients with moderate COPD ($22.6{\pm}3.14$) (p<0.05). 3). There were no significant differences in the serum IL-6, TNF-$\alpha$, carbonyl protein and 8-iso-prostaglandin $F_2{\alpha}$ according to the BMI in the COPD patients. Conclusion: The severity of the airway obstruction, not the systemic inflammatory markers and oxidative stress, might be associated with the BMI in stable COPD patients. Further study will be needed to determine the factors associated with the decrease in the BMI of COPD patients.

Development of the Massless Link Model including External Force and Bushing Deformation (외력과 부싱변형을 고려한 무질량 링크 모델 개발)

  • 손정현;최성태;김광석;유완석;이종년
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.163-170
    • /
    • 2001
  • In this paper, a massless link model transmitting external forces is developed to achieve the numerical efficiency in simulation of vehicle suspension systems. Forces acting on links are resolved and transmitted to attached points with a quasi-static assumption. Also, a theoretical derivation and computer implementation of a massless link with bushing elements are proposed. In the massless link with bushing elements, one end is connected to the adjacent body with bushings and the other end is connected with a spherical joint. The deformation of a massless link with bushing elements is theoretically determined by minimizing the potential energy function with quasi-static equilibrium assumption at each time step. Several simulations with a full vehicle model are carried out to compare the efficiency of the developed massless link component. From the results, it is concluded that the proposed approach can reduce the computational time considerably.

  • PDF

Analysis of Cotton/Polyester Fabrics using Pyrolysis Gas Chromatograpy (열분해-GC에 의한 면/폴리에스터 혼방 직물의 분석)

  • 조미숙;김명덕;박성우;윤기준;남재도;이종훈;이영관
    • Polymer(Korea)
    • /
    • v.27 no.3
    • /
    • pp.271-274
    • /
    • 2003
  • A pyrolysis gas-chromatographic method (Py-GC) was utilized for the identification as well as the content measurement of textile materials. Py-GC was applied to natural cotton fiber, synthetic polyester fiber, and their blended fabrics. The characteristic peaks originated from thermally decomposed products were observed, and the area of peak increased with the content of polyester. The products of pyrolized polyester were identified as benzoic acid terephthalic acid, and vinyl benzoic acid, which were characterized by mass spectrometry. This analytic method of offered a quantitative means to identify the content of cotton and polyester.

A Study on the Reduction of Harmful Exhaust Gas with Diesel-Methanol Stratified Injection System in a Diesel Engine (층상연료분사(경유/메탄올)를 이용한 디젤엔진의 유해 배출물 저감에 관한 연구)

  • 강병무;안현찬;이태원;정성식;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.43-50
    • /
    • 2002
  • In the present study, reduction of harmful exhaust gas in a diesel engine using stratified injection system of dual fuel (diesel fuel and methanol) was tried. The nozzle and fuel injection pump of conventional injection system were remodeled to inject dual fuel in order from the same injector. The quantity of each fuel was controlled by micrometers, which were mounted at rack of injection pumps. The injection ratio of dual fuel was certificated by volumetric ratio in injection quantity test. Cylinder pressure and exhaust gas were measured and analyzed under various supply condition of duel fuel. We confirmed that combustion of dual fuel was performed successful1y by using modified injection system in a D.I. diesel. Soot and NOx are simultaneously reduced by stratified injection without large deterioration of thermal efficiency, but THC and CO are relatively increased.

Migration characteristics with Forms of Channels and Bed Conditions (수로의 형상과 하상조건에 따른 이행특성)

  • 차영기;이종석
    • Water for future
    • /
    • v.26 no.1
    • /
    • pp.103-114
    • /
    • 1993
  • Migration characteristics with forms of channels and bed conditions are studied by constant-radius curve (CRC), sine-generated curve (SGC) and small-wave theory (SWT) method. For channels which are meandering and of which bed conditions are of coarse materials, transverse bed slope, depth and velocity distributions are predicted by CRC and SGC method, and the results are compared with measured field data, And for fine bed-materials of the sinuous channels, lateral and downvalley migration rates are computed by SWT method. It is confirmed from this investigation that transverse mass-flux factor plays significant roles in determining of magnitude and direction of meander migration.

  • PDF

Finite Element Model Building Procedure of an External Mounting Pod for Structural Dynamic Characteristics Analysis of an Aircraft (항공기 구조 동특성 해석을 위한 외부 장착 포드의 유한요소모델 구축 절차)

  • Lee, Jong-Hak;Ryu, Gu-Hyun;Yang, Sung-Chul;Jung, Dae-Yoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.72-77
    • /
    • 2011
  • In this study, the natural frequencies and mode shape of an external mounting pod were verified using the modal analysis and modal testing technique for a pod mounted on an aircraft. The procedure associated with the FEM building of an external mounted pod to predict the dynamic behavior of aircraft structures is described. The simplified FEM reflecting the results of the modal testing of a pod is built through the optimization, applied to the structural dynamic model of an Aircraft, used to verified the stability of vibration and flutter of an aircraft.

  • PDF

Vibration Characteristics of a Cantilevercd Beam with a Guided Mass and an Elastic Spring Supports (안내질량을 갖는 탄성지지된 외팔보의 진동 특성)

  • 류봉조;이규섭;이종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.408-413
    • /
    • 1994
  • The paper describes the vibration characteristics of the mechanical system consisting of a uniform cantilevered Timoshenko beam with a guided mass and an elastic spring supports. The free end of the beam does not rotate and the spring attatched to the guided mass is elastically restained against translation. The effect of magnitudes, rotary inertia and the size of the guided mass on the vibration characteristics is fully investigated by the numerical simulation using FEM and experiment. In order to verify the eigenvalue sensitivity for considered system, comparison exact solutions with FEM are conducted, and a good agreement between two solutions is also highlighted.

  • PDF

TM polarized photon tunneling in a frustrated total internal reflection structure (Frustrated Total Internal Reflection 구조에서의 TM 편광된 광자의 터널링)

  • Lee, Byoung-Ho;Lee, Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.112-119
    • /
    • 1996
  • TM polarized photon tunneling time and the position where TM photons appear after two-dimensional tunneling in a frustrated total internal reflection (FTIR) structure are calculated. This is done by converting the FTIR tunneling problem of TM photons to an electron tunneling problem with a position-dependent effective mass for a heterostructure potential barrier. Derived results are compared with TE photon cases.

  • PDF

A Study on the Tool Vibration Measurement Using the Fiber Optic Interferometric Sensor in Lathe Cutting Process (광섬유 간섭계 센서를 이용한 선삭가공 공구진동 측정 연구)

  • Lee, Jongkil
    • 대한공업교육학회지
    • /
    • v.32 no.2
    • /
    • pp.171-187
    • /
    • 2007
  • The purpose of this study is to measure the lathe tool vibration and verify its usefulness using the fiber optic interferometeric sensor instead of using common accelerometer. To compare two vibration signals a Fabry-Perot fiber optic sensor(FOS) is directly attached to the left-side surface of the lathe tool and an accelerometer is attached near to the fiber optic sensor. Measurement signals from the FOS and theoretical results of receptance simulation are compared. When the amplitude of tool vibration increased the frequency shift phenomena was occurred. This means that mass effect occurred and vibration spectrum moved to the low frequency region. Generally this results is agreement to the regenerative chatter. The chatter frequency is not same as the natural frequency of the tool itself. The FOS can also applied to laboratory experiments for students. This experimental technique is perhaps the first attempts because of directly attachment technique. Therefore, suggested Fabry-Perot fiber optic sensor can be used to monitoring the tool wear and vibration.