• Title/Summary/Keyword: 이용희

Search Result 8,884, Processing Time 0.035 seconds

The Neutralization Treatment of Waste Mortar and Recycled Aggregate by Using the scCO2-Water-Aggregate Reaction (초임계이산화탄소-물-골재 반응을 이용한 폐모르타르와 순환골재의 중성화 처리)

  • Kim, Taehyoung;Lee, Jinkyun;Chung, Chul-woo;Kim, Jihyun;Lee, Minhee;Kim, Seon-ok
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.359-370
    • /
    • 2018
  • The batch and column experiments were performed to overcome the limitation of the neutralization process using the $scCO_2$-water-recycled aggregate, reducing its treatment time to 3 hour. The waste cement mortar and two kinds of recycled aggregate were used for the experiment. In the extraction batch experiment, three different types of waste mortar were reacted with water and $scCO_2$ for 1 ~ 24 hour and the pH of extracted solution from the treated waste mortar was measured to determine the minimum reaction time maintaining below 9.8 of pH. The continuous column experiment was also performed to identify the pH reduction effect of the neutralization process for the massive recycled aggregate, considering the non-equilibrium reaction in the field. Thirty five gram of waste mortar was mixed with 70 mL of distilled water in a high pressurized stainless steel cell at 100 bar and $50^{\circ}C$ for 1 ~ 24 hour as the neutralization process. The dried waste mortar was mixed with water at 150 rpm for 10 min. and the pH of water was measured for 15 days. The XRD and TG/DTA analyses for the waste mortar before and after the reaction were performed to identify the mineralogical change during the neutralization process. The acryl column (16 cm in diameter, 1 m in length) was packed with 3 hour treated (or untreated) recycled aggregate and 220 liter of distilled water was flushed down into the column. The pH and $Ca^{2+}$ concentration of the effluent from the column were measured at the certain time interval. The pH of extracted water from 3 hour treated waste mortar (10 ~ 13 mm in diameter) maintained below 9.8 (the legal limit). From XRD and TG/DTA analyses, the amount of portlandite in the waste mortar decreased after the neutralization process but the calcite was created as the secondary mineral. From the column experiment, the pH of the effluent from the column packed with 3 hour treated recycled aggregate kept below 9.8 regardless of their sizes, identifying that the recycled aggregate with 3 hour $scCO_2$ treatment can be reused in real construction sites.

Quantitative Analysis of Amylose and Protein Content of Rice Germplasm in RDA-Genebank by Near Infrared Reflectance Spectroscopy (근적외선 분광분석법을 이용한 벼 유전자원의 아밀로스 함량과 단백질 함량 정량분석)

  • Kim, Jeong-Soon;Cho, Yang-Hee;Gwag, Jae-Gyun;Ma, Kyung-Ho;Choi, Yu-Mi;Kim, Jung-Bong;Lee, Jeong-Heui;Kim, Tae-San;Cho, Jong-Ku;Lee, Sok-Young
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.2
    • /
    • pp.217-223
    • /
    • 2008
  • Amylose and protein contents are important traits determining the edible quality of rice, especially in East Asian countries. Near-Infrared Reflectance Spectroscopy (NIRS) has become a powerful tool for rapid and nondestructive quantification of natural compounds in agricultural products. To test the practically of using NIRS for estimation of brown rice amylose and protein contents, the spectral reflectances ($400{\sim}2500\;nm$) of total 9,483 accessions of rice germplasm in Rural development Administration (RDA) Genebank ere obtained and compared to chemically determined amylose and protein content. The protein content of tested 119 accessions ranged from 6.5 to 8.0% and 25 accessions exhibited protein contents between 8.5 to 9.5%. In case of amylose content, all tested accessions ranged from 18.1 to 21.7% and the grade from 18.1 to 19.9% includes most number of accessions as 152 and 4 accessions exhibited amylose content between 20.5 to 21.7%. The optimal performance calibration model could be obtained from original spectra of brown rice using MPLS (Modified Partial Least Squares) with the correlation coefficients ($r_2$) for amylose and protein content were 0.865 and 0.786, respectively. The standard errors of calibration (SEC) exhibited good statistic values: 2.078 and 0.442 for amylose and protein contents, respectively. All these results suggest that NIR spectroscopy may serve as reputable and rapid method for quantification of brown rice protein and amylose contents in large numbers of rice germplasm.

Analysis and risk assessment of polycyclic aromatic hydrocarbons (PAHs) in seafood from oil contaminated bay (유류 오염지역의 수산물 중 다환방향족탄화수소류 (PAHs) 분석 및 위해평가)

  • Jeong, Ji-Yoon;Choi, Chan-Woong;Ryeom, Tai-Kyung;Cho, Kyoung-Hee;Park, Se-Ryung;Shin, Ho-Sang;Lee, Kwang-Ho;Lee, Hyo-Min
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.187-195
    • /
    • 2010
  • To assess health risk for the intake among residents after the Hebei Spirit oil spill, 16 Polycyclic Aromatic Hydrocarbons (PAHs) in seafood samples from oil contaminated bay were determined by Gas Chromatography-Mass Spectrometry (GC-MSD) and samples were personally collected and purchased by residents. Samples were hydrolyzed with KOH and extracted with methylene chloride. The extracted solution were cleaned up using silica/florisil column and 16 PAHs were eluted by methylene chloride : n-hexane (1:9) mixture and determined by GC-MSD in Selected Ion Monitoring (SIM) mode. The mean recoveries for 16 PAHs ranged from 79% to 85%. The 16 PAHs levels in 126 samples ranged from 0.17 to $6.04\;{\mu}g$/kg and the TEQBaP (Toxic EQuivalents) levels in 126 samples were calculated using benzo(a)pyrene toxic equivalency factor for individual 16 PAHs and ranged from 0 to $0.91\;{\mu}gTEQ$/kg. The average Benzo(a)pyrene dietary exposure of residents was $5.5{\times}10^{-8}\;mg/kg$ bw/day and the average PAHs chronic dietary exposure was $1.3{\times}10^{-5}\;mg$ TEQ/kg bw/day. The margin of exposure (MOE) and the excess cancer risk and were $1.8{\times}10^6$ and $9.8{\times}10^{-8}$, respectively. Therefore, the assessment result was considered as low concern for health risk.

A Study on the Screening of the Novel Genes Associated with Lysosomal Trafficking and Mutation Detection in Fibroblasts of the Patients with Mucolipidosis type II and III (리소좀 교통 이상을 초래하는 뮤코지방증 2형과 3형 환자의 섬유아세포를 이용한 신규 유전자 탐색 및 돌연변이에 대한 연구)

  • Song, Seng Mi;Chang, Soo Hee;Paik, Kyung Hoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.5 no.1
    • /
    • pp.65-75
    • /
    • 2005
  • Purpose: To understand genetic differences and similarities between mucolipidosis and control. Methods: Using the fibroblast of the mucolipidosis II and control, forward and reverse subtracted libraries were constructed. Among these clones, we investigated mutations in the GNPTA (MGC4170) gene, which codes for the ${\alpha}/{\beta}$ subunits of phosphotransferase, and in the GNPTAG gene, which codes for the ${\gamma}$ subunits in 5 Korean patients with mucolipidosis type II or IIIA. Result: Several differentially expressed cDNAs were cloned and their sequences were determined. Mutation analysis of the interested gene, GNPTA was performed and we identified 7 mutations in the GNPTA gene, but none in the GNPTAG gene. The mutations in type II patients included p.Q104X(c.310C>T), p.R1189X(c.3565C>T), p.S1058X(c.3173C>G), p.W894X(c.2681G>A) and p.H1158fsX15(c.3474_3475delTA), all of which are non-sense or frame shift mutations. However, a splicing site mutation, IVS13+1G>A (c.2715+1G>A) was detected along with a non-sense or a frame shift mutation (p.R1189X or p.E858fsX3(c.2574_2575delGA)) in two mucolipidosis type IIIA patients. Conclusion: This report shows that mutations in the GNPTA gene coding for the ${\alpha}{\beta}$subunits of phosphotransferase, and not mutations in the GNPTAG gene, account for most of mutations found in Korean patients with mucolipidosis type II or IIIA.

  • PDF

β-glucan Stimulates Release of TNF-α in Human Monocytic THP-1 Cells (인간 단핵구 THP-1 세포에서 β-glucan으로 인한 TNF-α 분비 증가 효과)

  • Keum, Bo Ram;Hyeon, Jin Yi;Choe, So Hui;Jin, Ji Young;Jeong, Ji Woo;Lim, Jong Min;Park, Dong Chan;Cho, Kwang Keun;Choi, Eun Young;Choi, In Soon
    • Journal of Life Science
    • /
    • v.27 no.11
    • /
    • pp.1256-1261
    • /
    • 2017
  • ${\beta}$-glucan is a constituent of the cell wall of fungi, yeast and plants. It plays an important role in the immune system such as activation of immunocyte, release of pro-inflammatory and anti-cancer effect. The immune system maintains a healthy immune homeostasis. However, when pathogenic substances enter the body, immune homeostasis can break down and disease can be triggered. Therefore, we studied a substance that regulates immune homeostasis. The purpose of the study we demonstrated whether the ${\beta}$-glucan can be applied to the immune-modulation effects in human monocytic THP-1 cells. ${\beta}$-glucan was incubated in THP-1 cells at various concentrations. The $TNF-{\alpha}$ mRNA expression and protein levels were analyzed by ELISA and Real-time PCR. Additionally, the expression of MAPKs (p38 and JNK), $I{\kappa}B-{\alpha}$ and $NF-{\kappa}B$ p50 were analyzed by western blot. ${\beta}$-glucan enhanced the production of $TNF-{\alpha}$ mRNA expression and protein levels in human monocytic THP-1 cells. In addition, activation of MAPKs (p38 and JNK) and $NF-{\kappa}B$ p50 induced by ${\beta}$-glucan were increased. The study suggests that ${\beta}$-glucan contributes to immune-stimulation effect by production $TNF-{\alpha}$ in human monocytic THP-1 cells, and that MAPKs and $NF-{\kappa}B$ p50 are involved in the process. Synthetically, we have suggested ${\beta}$-glucan may be improved to immune system effect in human monocytic THP-1 cells.

STUDY ON THE INTERFACE BETWEEN LIGHT-CURED GLASS IONOMER BASE AND INDIRECT COMPOSITE RESIN INLAY AND DENTIN (기저재용 광중합형 글래스아이오노머의 치질 및 복합 레진 인레이에 대한 접착양상)

  • Lee, Song-Hee;Kim, Dong-Jun;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.158-169
    • /
    • 2005
  • This study was done to evaluate the shear bond strength between light-cured glass ionomer cement (GIC) base and resin cement for luting indirect resin inlay and to observe bonding aspects which is produced at the interface between them by SEM. Two types of light cured GIC (Fuji II LC Improved, GC Co. Tokyo, Japan and Vitrebond$^{TM}$, 3M, Paul Minnesota U.S.A) were used in this study. For shear bond test, GIC specimens were made and immersed in 37$^{\circ}C$ distilled water for 1 hour, 24 hours, 1 week and 2 weeks. Eighty resin inlays were prepared with Artglass$^{(R)}$ (Heraeus Kultzer Germany) and luted with Variolink$^{(R)}$ II (Ivoclar Vivadent, Liechtenstein). Shear bond strength of each specimen was measured and fractured surface were examined. Statistical analysis was done with one-way ANOVA. Twenty four extracted human third molars were selected and Class II cavities were prepared and GIC based at axiopulpal lineangle. The specimens were immersed in 37$^{\circ}C$ distilled water for 1 hour, 24 hours, 1 week and 2 weeks. And then the resin inlays were luted to prepared teeth. The specimens were sectioned vertically with low speed saw. The bonding aspect of the specimens were observed by SEM (JSM-5400$^{(R)}$, Jeol, Tokyo, Japan) .There was no significant difference between the shear bond strength according to storage periods of light cured GIC base. And cohesive failure was mostly appeared in GIC On scanning electron micrograph, about 30 - 120 $\mu$m of the gaps were observed on the interface between GIC base and dentin. No gaps were observed on the interface between GTC and resin inlay.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Crosshole EM 2.5D Modeling by the Extended Born Approximation (확장된 Born 근사에 의한 시추공간 전자탐사 2.5차원 모델링)

  • Cho, In-Ky;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.2
    • /
    • pp.127-135
    • /
    • 1998
  • The Born approximation is widely used for solving the complex scattering problems in electromagnetics. Approximating total internal electric field by the background field is reasonable for small material contrasts as long as scatterer is not too large and the frequency is not too high. However in many geophysical applications, moderate and high conductivity contrasts cause both real and imaginary part of internal electric field to differ greatly from background. In the extended Born approximation, which can improve the accuracy of Born approximation dramatically, the total electric field in the integral over the scattering volume is approximated by the background electric field projected to a depolarization tensor. The finite difference and elements methods are usually used in EM scattering problems with a 2D model and a 3D source, due to their capability for simulating complex subsurface conductivity distributions. The price paid for a 3D source is that many wavenumber domain solutions and their inverse Fourier transform must be computed. In these differential equation methods, all the area including homogeneous region should be discretized, which increases the number of nodes and matrix size. Therefore, the differential equation methods need a lot of computing time and large memory. In this study, EM modeling program for a 2D model and a 3D source is developed, which is based on the extended Born approximation. The solution is very fast and stable. Using the program, crosshole EM responses with a vertical magnetic dipole source are obtained and the results are compared with those of 3D integral equation solutions. The agreement between the integral equation solution and extended Born approximation is remarkable within the entire frequency range, but degrades with the increase of conductivity contrast between anomalous body and background medium. The extended Born approximation is accurate in the case conductivity contrast is lower than 1:10. Therefore, the location and conductivity of the anomalous body can be estimated effectively by the extended Born approximation although the quantitative estimate of conductivity is difficult for the case conductivity contrast is too high.

  • PDF

A Study on Dental Hygienists' Health Management and Their Use of Medical Care Services (치과위생사의 건강관리 및 의료 이용 행태에 관한 조사 연구)

  • Yoon, Mi-Sook;Lee, Kyung-Hee
    • Journal of dental hygiene science
    • /
    • v.4 no.1
    • /
    • pp.13-20
    • /
    • 2004
  • The purpose of this study was to examine how dental hygienists health management and to what extent they used medical care services due to occupational diseases. It's ultimately attempted to improve the health care of dental hygienists and promote their health. After relevant literature and data were reviewed, a survey was conducted for five months from June through October, 2003. The subjects in this study were 160 dental hygienists who worked at dental hospital and clinics across the nation. And the collected data were analyzed. The findings of this study were as follows: (1) Concerning job-related health education experience, 83.1 percent, the greatest rate, had no experience to receive education, and the type of service made a significance difference to that(p<0.05). (2) As to in-house medical examination, 98.6 percent felt the need for medical examination, and 56.3 percent had ever their bodies examined. Their health examination experience was significantly different according to age(p<0.01), marital status(p<0.01), type of service(p<0.01), career(p<0.01) and yearly income(p<0.01). (3) Concerning how much they used hospitals after working as dental hygienists, 85.6 percent, the biggest group, had no experience to be hospitalized, and that was significantly different according to age(p<0.05), type of service(p<0.05), career(p<0.01) and yearly income(p<0.05). 51.9 percent had no experience to receive treatment as outpatients, and their career(p<0.01) made a significant difference to that. (4) As for how to cope with casual diseases, 34.4 percent, the largest group, visited pharmacies, and 32.5 percent, the next largest group, saw the doctors. In regard to herb restorative, 68.1 percent had no experience to take herb restorative, and that experience varied significantly with age(p<0.01), career(p<0.05) and annual income(p<0.01).

  • PDF

Study on the beam properties of small field sizes (소조사면 전량분포의 특성에 관한 고찰)

  • Cho JeongHee;Lee SangKyu;An SeungKwon;Park Jell
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • Purpose : The aim of this study is to investigate the properties of small field size and to measure the penumbra and central axis depth dose varying to the jaw setting and off axis distance for indicate this data to small field sizes radiation therapy. Material and methods : The percentage depth dose, beam profile and central axis output dose was measured by farmer type ion chamber and pinpoint chamber using Primart linac with 6MV energy. Beam quality and penumbra variations according to the central axis shift, from center to every 2cm outside increment, and field size, from $1{\times}1cm$ to $10{\times}10cm$ was investigated and compared with that of the standard geometrical condition's results Results : The differences of measured values between two ion chamber was about $37\%$ at 10cm depth with $1{\times}1cm$ field sizes but as field size increased this differences was diminished gradually. Measured data from various off axis distance with the different asymmetric collimations are not changed significantly but as size decreased the dose variation was increased and at $1{\times}1cm$ field size dose difference among off axis distance was as much as $13\%$, and as shallower the measured depth the central axis dose variations among the OAD was increased, penumbra was not changed noticeably depending on off axis distance but the percentage of penumbra from its initial field sizes was strongly dependant on field sizes and penumbra occupation rates of its own field sizes ranging from $6\%$ at $10{\times}10cm$ to $50\%$ at $1{\times}1cm$ field size. Conclusion : For imrt treatment, there are several numbers of different gentry angles with beams of nonuniform fluences are required and several complex factors involved. Among them the characteristics of beam output varying to the geometrical setting and design of collimators are of important to attaining a good treatment results. As mentioned in results the differences of measured values are changed significantly depends on ion chamber volume, depths and field size. For providing quality radiation treatment, especially at small field size, those factor's should have considering deliberately.

  • PDF