• Title/Summary/Keyword: 이온선택전극

Search Result 135, Processing Time 0.027 seconds

Differential Pulse Voltammetric Determination of Iron(III) Ion with a Sodium Dodecyl Sulfate Modified Glassy Carbon Electrode (시차펄스전압전류법에서 도데실황산나트륨이 수식된 유리탄소전극에 의한 선택성 있는 철(III) 이온의 정량)

  • Ko, Young Chun;Kim, Jin Ah;Chung, Keun Ho
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.427-432
    • /
    • 1997
  • A selective method for the determination of iron(III) ion with a sodium dodecyl sulfate(SDS) modified glassy carbon electrode was proposed. It was based on the electrostatic attraction and complexation of the SDS modifier, $(DS^-)_n-Fe^{3+}$. The determination of iron(III) ion was performed by a differential pulse voltammetry(DPV), and the reduction peak potential of $(DS^-)_n-Fe^{3+}$ was +0.466(${\pm}0.002$)V vs. Ag/AgCl. For the determination of iron(III) ion, a linear calibration curve was obtained within the iron(III) ion concentration range of $0.50{\times}10^{-5}{\sim}10{\times}10^{-5}mol/L$, and the detection limit was $0.14{\times}10^{-5}mol/L$. $Cu^{2+}$, $Ni^{2+}$, $Co^{2+}$, $Pb^{2+}$, $Zn^{2+}$, and $Mn^{2+}$ showed little or no effect on the determination of iron(III) ion, respectively. But, ion such as each $CN^- $ and $SCN^-$ interfered seriously.

  • PDF

A Study on the Separation of Cadmium from Waste Ni-Cd Secondary Batteries by Ion Substitution Reaction (이온치환 반응을 이용한 니켈-카드뮴 폐이차전지에서 카드뮴의 분리에 대한 연구)

  • Kim, Dae-Weon;Park, Il-Jeong;Ahn, Nak-Kyoon;Jeong, Hang-Chul;Jung, Soo-Hoon;Choi, Joong-Yup;Yang, Dae-Hoon
    • Resources Recycling
    • /
    • v.27 no.4
    • /
    • pp.36-43
    • /
    • 2018
  • In order to recycle waste nickel-cadmium batteries, cadmium was selectively removed by ion substitution reaction so that cadmium and nickel could be separated efficiently. The electrode powder obtained by crushing the electrode in the waste nickelcadmium battery was leached with sulfuric acid. The cadmium in the nickel-cadmium solution was precipitated with cadmium sulfide by the addition of sodium sulfide. Ion substitution experiments were carried out under various conditions. At the optimum condition with pH = -0.1 and $Na_2S/Cd=2.3$ at room temperature, the residual Cd in the solution was about 100 ppm, and most of it was precipitated with CdS.

The Effect of Some Binary Additive Systems in the Electrodeposition of Cadmium (카드뮴 전해석출에서의 이성분첨가물계의 효과)

  • Lee, Kyung Ho
    • Analytical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.161-167
    • /
    • 1996
  • An investigation was made of possible ways in which one could control the relative rates of cadmium deposition and hydrogen evolution by binary additive systems. Benzyl alcohol was employed as an additives due to its ability to form a hydrophobic film which inhibit the electroreduction of water to form hydrogen. The second additive was chosen to make the cadmium(II) ion less hydrophilic and increase its ability to cross the hydrophobic benzyl alcohol film and be electrodeposited at the cathode. It was shown by voltammetric and current efficiency studies that ion pairing and complexing additives could be used to accelerate the reduction of cadmium in the presence of the benzyl alcohol film. It was also shown that the benzyl alcohol film lowered the dielectric constant of the solution near the electrode enough to obtain ion pairing between the sodium ion and the negative chloride complex of cadmium and accelerate the reduction of the cadmium. This acceleration did not occur in the sulfate solution in the absence of chloride since cadmium(II) is primarily present as a positive aquo complex and ion pairing, if it occured, would not accelerate but would hinder reduction of cadmium.

  • PDF

MDOF Ionic-Polymer-Metal-Composite Actuators with Selectively Grown Multiple Electrodes (선택적으로 성장 시킨 다중 전극판을 갖는 다자유 IPMC 작동기)

  • Jeon, Jin-Han;Oh, Il-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.294-298
    • /
    • 2008
  • The ionic polymer-metal composite actuators with selectively grown multiple electrodes were developed to mimic the swimming locomotion of a fish. The developed method is based on combining electroplating with the electroless chemical reduction using the patterned mask. The advantages of this fabrication method are that the initial compositing between the polymer and platinum particles can be assured by the chemical reduction method, and the thickness of each electrode can be controlled easily and rapidly by electroplating. By using the fabricated actuator with a multiple degree of freedom, the oscillatory wave of the flexible membrane actuator was generated and a twisting motion was also realized to verify the possibility of mimicking the fish-like locomotion. The frequency response function was analyzed to investigate the natural frequency and the damping factor by a mechanical shaker and direct electrical excitation through the swept-sine method. Present results show that this novel method can be a promising technique to easily pattern each of multiple electrodes and to implement the biomimetic motion of the polymer actuators with good mechanical bending performance.

  • PDF

Ionic Recognition with Quinone-Derivatized Calixarenes in Solution and at Self-Assembled Monlayers

  • Kim Hasuck;Kang Sun Kil;Chung Taek Dong
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.2
    • /
    • pp.69-71
    • /
    • 2000
  • Redox-active calix[4]arenes with carboxylic acid and disulfide groups were prepared and spontaneous deposition on silver and gold surfaces was observed. Owing to their unusual structure, the calix[4]arenes exhibit selective affinity fur alkaline earth metal ions in aqueous media. When annular ionophores are immobilized on the surface, voltammetric and spectroscopic studies show the entrapment of metal ions. Furthermore, it was possible to reversibly capture and remove the ions using strong chelating agents such as ethylenediaminetetraacetic acid (EDTA).

Application of Ion-Selective Electrodes to Measure Ionic Concentrations of Macronutrients in Hydroponics (수경재배 시 다량 이온 농도 측정을 위한 이온 선택성 전극의 응용)

  • Kim, Min-Su;Park, Tu-San;Cho, Seong-In
    • Journal of Biosystems Engineering
    • /
    • v.32 no.1 s.120
    • /
    • pp.37-43
    • /
    • 2007
  • This study was carried out to investigate the applicability of PVC membrane-based ion-selective electrodes for macronutrients (K, Ca, and N) by measuring of potassium, calcium, nitrate ions in hydroponic nutrient solution. The capabilities of two ion-selective membranes with varying chemical compositions for each ion were evaluated in terms of sensitivity, selectivity, and lifetime to choose sensing elements suitable for measuring typical ranges of nutrient concentrations in hydroponic solutions. The selected calcium and nitrate ion-selective membranes showed effectively sensitive responses to calcium and nitrate ions with lifetimes of 25 and 15 days, respectively. The addition of a cation additive to the potassium membrane cocktail allowed its sensitivity to be increased whereas its lifetime was reduced from 30 days to 10 days.

Application of a. Strip Ion-Selective Electrode Sensor for Hydroponic Nutrient Solution Analysis - NO3 Analysis - (양액의 영양분 분석을 위한 Strip형 이온선택성전극 센서 의 응용 -NO3 이온 분석 -)

  • 김기영
    • Journal of Biosystems Engineering
    • /
    • v.28 no.4
    • /
    • pp.335-342
    • /
    • 2003
  • A simple disposable thick-film potentiometric strip has been developed and evaluated for hydroponics application. The strip consisted of low ion-selective electrodes (ISE) fabricated by screen-printing technology. The electrochemical responses of ion sensors for nitrate, ammonium, potassium, and magnesium were measured with specially designed 16-channel low voltage signal transducers. The analytical characteristics of the sensors were comparable with those of conventional ISE sensors. The thick-film sensors exhibit linear relationships over five concentration decades. The concentration of N $O_3$ - ion in standard solution can be determined by direct potentiometric measurements without any conditioning before measurements. However, measurement of $K^{+}$, N $H_4$$^{+}$, and $Mg^{2+}$ ionic concentrations in nutrient solutions seems not feasible.

Determination of Basic Drugs with Ion-Selective Membrane Electrodes Using Ion-Exchanger (이온교환체 이온선택성 전극을 이용한 염기성의약품 정량)

  • 이지연;정문모;허문회;김은정;안문규
    • YAKHAK HOEJI
    • /
    • v.43 no.3
    • /
    • pp.289-293
    • /
    • 1999
  • Many poly (vinyl chloride : PVC) membrane electrodes were investigated for the determination of basic drugs, chlorpromazine, amitriptyline, nortriptyline, etc. These electrodes are based on the use of the ion-association complexes of the basic drugs with eriochrome cyanine R, chromoxane cyanine, chrome azurol S and picric acid as ion-exchange sites in a plasticized PVC matrix. All ion-exchangers except picrate complex were not proper for use, because those complexes in plasticized membrane were excluded into aqueous working solution. These drug electrodes show excellent Nernstian responses in the concentration ranges $10^{-2}~10^{-6}$ mol $dm^{-3}$. Their selectivity with respect to each other, as well as their work-able pH range have been investigated. The major advantages of the proposed methods are their simplicity and speed.

  • PDF

Determination of Mefenamic Acid with Fe(II)-Dipyridyl-Mefenamic Acid Ternary Complex as Ion-exchagner (철-디피리딜-메페남산 삼원착물을 이용한 메페남산의 정량)

  • Nam, Su Ja;Moon, Hyun Sook;Lee, Mi Na;Jung, Moon Mo;Hur, Moon Hye;Ahn, Moon Kyu
    • Analytical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.59-63
    • /
    • 2001
  • A PVC membrane electrodes based on Fe(II)-dipyridyl-mefenamic acid ternary complex as ion exchanger were prepared using o-nitrophenyl octyl ether as a plasticizer. The 2,2'-dipyridyl, 4,4'-dipyridyl and 4,4'-dipyridyl-2,2'-dipyridyl were used as dipyridyl derivative ligand. The electrode dxhibits a fast stable and linear response for $10^{-5}-10^{-3}mol/L$ mefenamate with an anionic slope of -55.98, -49.47, -59.35mV/decade in pH 8.9 borate buffer solution respectively. Potentiometric selectivity measurements revealed negligible interferences from aromatic and aliphatic carboxylic acid salts.

  • PDF

Ion-Selective Electrodes in Drugs Analysis: Verapamil-Selective Polymeric Membrane Electrodes Based on Calix[4]arene and Dibenzo-18-crown-6-ether Ionophores (이온 선택성 전극을 이용한 의약품 정량: Calix[4]arene과 Dibenzo-18-crown-6-ether에 의한 verapamil-선택성 polymeric membrane electrode)

  • 이은엽;김성진;김영학;김재현;허문회;안문규
    • YAKHAK HOEJI
    • /
    • v.39 no.1
    • /
    • pp.61-67
    • /
    • 1995
  • PVC membrane electrodes based on the lipophilic neutral carrier, dibenzo-18-crown-6, cyclic oligomers of teit-butylphenol-formaidehyde condensates, calix[4]arenes as the active sensors for verapamil have been prepared and tested in a variety of plasticizers. At pH 5.0, the electrode exhibits a Nernstian response in the range of 10$^{-2}$~5$\times$10$^{-5}$ M verapamil with a slope of 49.1$\pm$0.5mV per concentration decade. The electrode constructed in this work can be used continuously for at least 1 month before any damage to the membrane occurs. And the analyses of the local anesthetic amine, which are good to select a specific compound in a mixed solution, were also accomplished by using of another neutral carrier, a DB18C6, for comparing with calix[4]arene.

  • PDF