• Title/Summary/Keyword: 이상 수질

Search Result 1,235, Processing Time 0.034 seconds

Copper Recovery from Waste Water of Electronic Industry in a Fluidized Bed Reactor (유동층 반응기에서 전자 공장폐수로부터 동의 회수)

  • Lim, Wan-Mook;Woo, Kwang-Jae;Cho, Yong-Jun;Kang, Yong;Won, Chang-Whan;Kim, Sang-Done
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.482-488
    • /
    • 1997
  • Copper recovery from waste water of electronic industry has been conducted effectively in a fluidized bed reactor. Initial concentration of copper in the waste water, liquid flow rate in the reactor, reaction temperature and time and current density between the cathode and anode in the reactor have been selected as operating variables. The effects of operating variables on the recovery of copper have been studied. It has found that the copper resolved in the waste water can be recovered continuously by means of a fluidized bed reactor The recovery of copper decreased with an increase in the initial concentration of copper in the waste water, while it increased with increasing reaction time and current density, however, it exhibited its maximum value with the variations of liquid flow rate and reaction temperature. The optimum reaction condition to maintain the copper recovery around 85% is as follows ; $X_o=3wt%$, $U_L=0.5cm/s$, $T=25^{\circ}C$, $I=7A/dm^2$ and t=2hrs within this experimental condition.

  • PDF

A study on the estimation of TMDL run-off pathway coefficients for livestock resources (축분자원화물의 총량관리지침 배출구조계수 산정에 관한 연구)

  • Han, Gee-Bong;Lee, Young-Sin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.3
    • /
    • pp.99-107
    • /
    • 2013
  • In this study, field scale test was conducted to estimate the TMDL coefficients (runoff and leachate:(${\beta}4$)(${\beta}5$)(${\beta}8$)) for the livestock resources applying to agricultural crop land as fertilizer, and the results were obtained as follows. Each waste reduction coefficient(${\beta}4$) was shown to be in the range of 0.94~0.75 for public waste treatment plants and 0.99~0.83 for private waste treatment in the analysis of BOD, COD, SS, T-N, T-P, TOC. Thus private plants showed higher rate. Waste treatment discharge into the land coefficient (${\beta}5$) was also shown to be in the range of 0.4.~0.24 for public plants and 0.75~0.16 for private plants, so it is much lower than other coefficients. However SS and T-P were shown to be much higher for land discharge in private plants than in public plants. Treatment coefficient in the public plants (${\beta}8$) appeared to be average 0.75 for T-P but over 90% treatment efficiency and also large deviation were observed due to 0.2 of some other treatment plants.

The Variation of Water Temperature and the Mass Mortalities of Sea Squirt, Halocynthia roretzi along Gyeongbuk Coasts of the East Sea in Summer, 2006. (2006년 하계 경북 연안의 수온변화와 우렁쉥이 폐사)

  • Lee, Yong-Hwa;Shim, Jeong-Min;Kim, Young-Suk;Hwang, Jae-Dong;Yoon, Suk-Hyun;Lee, Chu;Jin, Hyun-Gook
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.4
    • /
    • pp.15-19
    • /
    • 2007
  • Mass mortalities of the farmed sea squirt, Halocynthia roretzi, occurred in August, 2006 along the Gyeongbuk coasts of the East Sea without any pathological symptom. Suspecting the No. 10 typhoon, Wukong, which had passed over the relevant locations in the middle of August, 2006 as a culprit of the mortalities, we compared water temperature stratifications of the affected coasts before and after the typhoon. Just prior to the typhoon, cold waters lower than $15^{\circ}C$ were stratified at depths deeper than 10m probably by a persisting upwelling of cold bottom waters. The typhoon enforced water off-coast waters into coasts for 5 days, replacing the cold waters at depths $10{\sim}20m$ which can be justified by Ekman Spiral Effect. The results were an increment of water temperature by $10^{\circ}C$ and more at depths where sea squirts were suspended. The sudden elevation of water temperature might drive the sea squirts under abnormal stress to mass mortality.

  • PDF

Development of BNR(Biological Nutrient Removal) Process Using Expanded Polystylene(EPS) Media (Expanded Polystylene(EPS) 여재를 이용한 BNR(Biological Nutrient Removal) 공정 개발)

  • Ryu, Hong-Duck;Min, Kyung-Kook;Lee, Jeong-Hun;Choi, Kyoung-Young;Lim, Heun-Eun;Kim, Chul-Hwan;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Biological nutrient removal(BNR) process used in this study, which was packed with EPS(expanded polystylene) media, has more many advantages in aspect of reducing hydraulic retention time(HRT) of the process and having less effect of temperature in the winter season than commercial process in the present. Bench-scale study was performed using domestic wastewater. In the results, it was observed that the T-N removal efficiencies in HRT 6 hr and HRT 4 hr were 55% and 51%, respectively, showing the small reduction (about 4%) of T-N removal efficiency according to shortening of HRT. In comparison of T-N removal characteristic in summer and winter seasons, it showed that T-N removal efficiencies in summer and winter seasons were 65% and 54%, respectively, showing the 11% lower T-N removal efficiency in winter season than in summer season due to deterioration of nitrification in winter season. In the studies of influent loading rate and C/N ratio, the process showed stable effluent quality under the condition of broad influent loading rate and C/N ratio. Therefore, it is anticipated that the developed process in this study could be applicable to small wastewater treatment plant in nutrient removal.

Evaluation of Filter-Adsorber(F/A) Process for Removal of Disinfection By-products(DBPs) (소독부산물 제어를 위한 실공정 F/A 운영에 관한 고찰)

  • Kim, Seong-Su;Lee, Kyung-Hyuk;Lim, Jae-Lim;Chae, Seon-Ha;Kang, Byeong-Soo;Moon, Pil-Joong;Ahn, Hyo-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1035-1042
    • /
    • 2005
  • Granular Activated Carbon(GAC) is widely used in drinking water treatment. At S and B Water Treatment Plant, GAC is used in place of granular media in conventional rapid filters(GAC Filter-Adsorber) for removal of Disinfection By-products(DBPs). The primary focus of this study is on the performance of existing filter-adsorber, and their operation. It was found that F/A process removed turbidity as effective as sand system. The ratio of Hydrophobic DOM (HPO) and hydrophilic DOM (HPI) fraction in the raw water at S and B WTP was similar. Filter Adsorber presented earlier DOC breakthrough and steady state condition which was contributed by biodegradation during operation period. The removal efficiency of DBPs were used to evaluate the filter performance. The DBPs concentration of F/A treated water was below treatment goal level (THM < $80\;{\mu}g/L$, HAA < $60{\mu}g/L$). The removal efficiency of THM decreased rapidly during operation period. However, HAA were removed steadily regardless of the influent concentration of HAA. These results indicate that the removal of THM depend upon the adsorption mechanism while the removal of HAA depend upon biodegradation as well as adsorption. The decrease of adsorption capacity and characteristic value of GAC may be attributed to the effect of high organic loading, residual free chlorine, coagulants, manganese oxidants and frequently backwashing. This study has confirmed that Filter adsorber process can be considered as effective alternatives for the removal of DBPs, especially HAA.

Evaluation of System operated by Feed-and-discontinuous Bleed Mode using Tubular Type Ultrafiltration Membrane for Water Treatment (Feed-and-discontinuous Bleed 방식으로 운전되는 정수처리용 관상형 한외여과막 시스템의 평가)

  • Choi, Hyeok;Seo, Young-Woo;Kim, Hyung-Soo;Im, Jong-Seong;Hwang, Sun-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2187-2195
    • /
    • 2000
  • A water treatment system using membrane separation technology can provide stable effluent quality and its maintenance is relatively easy comparing to the conventional water treatment system. In addition, the membrane filtration system is very compact such that it can replace existing water treatment processes of coagulation/sedimentation/filtration by only one process. However, a major problem associated with membrane filtration is flux decline with operating time due to concentration polarization and fouling, so a systematic study on evaluation of long-term filtration performance is necessary. A membrane filtration system using tubular type ultrafiltration membranes with MWCO of 30.000 Da was constructed for this study and it had been operated in a feed-and-discontinuous bleed mode. Flux was stabilized after operation of 1.500 hours and maintaining above 25 LMH until 4.000 hours. Contaminants causing SS and turbidity were almost completely removed while the $UV_{260}$ and DOC removals were 55% and 49%, respectively. A simple mass balance equation was developed to predict maximum concentrations of SS, turbidity, $UV_{260}$ and DOC in a operation cycle. For SS and turbidity the measured max, concentrations in each cycle agree well with the predicted values while the measured max, concentrations of $UV_{260}$ and DOC were 59% and 37% of the predicted values, respectively.

  • PDF

Variation of Nitrogen Removal Efficiency and Microbial Communities Depending on Operating Conditions of a CANON Process (CANON 공정에서 운전조건에 따른 질소 제거효율 및 미생물군집 변화)

  • Jo, Kyungmin;Park, Younghyun;Cho, Sunja;Lee, Taeho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.6
    • /
    • pp.332-339
    • /
    • 2015
  • Nitrogen removal is one of the most important issues about wastewater treatment because nitrogen is a primary pollutant caused various problems such as eutrophication. We developed a CANON microbial community by using AOB and ANAMMOX bacteria as seeding sources. When 100 mg-N/L of influent ammonium was supplied, the DO above 0.4 mg/L showed a very low TN removal efficiency while the DO of 0.3 mg/L showed TN removal efficiency as high as 71.3%. When the influent ammonium concentration was reduced to 50 mg/L, TN removal efficiency drastically deceased. However, TN removal efficiency was recovered to above 70% after 14 day operation when the influent nitrogen concentration was changed again from 50 mg-N/L to 100 mg-N/L. According to the operating temperature from $37{\pm}1^{\circ}C$ to $20{\pm}1^{\circ}C$, TN removal efficiency also rapidly decreased but gradually increased again up to $70.0{\pm}2.6$%. The analysis of PCR-DGGE showed no substantial difference in microbial community structures under different operational conditions. This suggests that if CANON sludge is once successfully developed from a mixture of AOB and ANAMMOX bacteria, the microbial community can be stably maintained regardless of the changes in operational conditions.

Body Residue-based Approach as an Alternative of the External Concentration-based Approach for the Ecological Risk Assessment (외부환경농도에 기반한 생태위해성 평가방법의 대안으로서 생체잔류량 접근법)

  • Lee Jong-Hyeon
    • Environmental Analysis Health and Toxicology
    • /
    • v.21 no.2 s.53
    • /
    • pp.185-195
    • /
    • 2006
  • 환경오염물질로부터 수생태계 보호를 위한 표준적인 평가 및 관리 수단인 수질환경기준은 오염물질의 독성작용이 일어나는 표적기관에서의 오염물질의 농도에 대한 대체측정치로서 환경 내 오염물질의 농도를 이용해 왔다. 이러한 '외부환경농도에 기반한 접근방법'은 표적기관에서의 독성물질의 농도가 생물체내 농도에 비례하고, 결국 외부환경농도에도 비례할 것이라고 가정한다. 따라서 환경오염물질의 생물이용도나 생물축적 양상의 차이 때문에 고유 독성치를 비교 평가하는데 한계가 있다. 이와 달리 '생물체내 농도에 기반한 접근방법(이하 생체잔류량 접근법)'은 환경오염물질의 생물이용도나 종 특이적 생물축적 양상과 관련된 불확실성을 제거하고, 환경오염물질 고유의 독성을 비교 평가할 수 있게 해준다. 특히 생체잔류량 접근법을 독성동태학 및 독성역학 모델과 함께 사용하는 경우는 실제 현장에서 일어나는 복잡한 노출조건에서의 독성영향을 예측하는데 활용할 수 있다. '생체잔류량 접근법'은 독성기작별 임계잔류량(Critical Body Residue)을 결정함으로써 생물모니터링의 결과를 해석하는데 적용되고 있다. 또한 생태위해성평가를 위해서 필요한 '무영향예측농도(Predicted No-effect Concentration, PNEC)를 예측하기 위한 방법으로 생체 내 잔류량에 기반해서 농도-시간-반응관계를 기술하고, 예측할 수 있는 새로운 유형의 독성역학 및 독성동태학 모델을 제시하고, 생체내 '무영향농도(No Effect Concentration, NEC)'를 추정하게 해 준다. 특히 생체내 NEC는 '무영향관찰농도(No Observed Effect Concentration, NOEC)'와 '영향농도(Effect Concentration, EC)'처럼 분산분석이나 회귀분석모델과 같은 통계적 모델에 기반해서, 농도-반응관계만을 기술할 뿐인 기존 독성모델을 대체할 대안으로 최근에 OECD와 ISO에 의해서 추천되었다.분석을 시행한 결과 인지기능 장애정도 및 MMSEK 점수 증가에 따른 사망위험도는 어느 모형에서도 인지기능 장애정도가 사망에 미치는 위험도는 통계적으로 유의하지 않았다(표 6, 표 7). 이상 본 연구는 농촌지역 노인들에서 인지기능 장애정도가 사망에 미치는 영향을 알아보고자 하였지만, 인지기능 장애정도가 사망에 미치는 영향을 통계적으로 유의하게 고찰하지 못하였다.의한 차이를 보였다. (P<0.05, P<0.001) 5. Excelco로 부식처리된 도재가 5% HF 용액으로 부식처리된 도재보다 부식정도가 더 현저하였다.은 제언을 하고자 한다. 먼저, 학교급식에 대한 식단 작성 시 학생들이 학교에서 제공되기 원하는 식단에 대한 의견을 받고 그 의견에 대한 결과를 게시하여 학생들이 제공되기 원하는 식단을 급식 시 제공하여 학생들이 식단선택에 동참할 수 있는 기회를 주는 것이 바람직하겠다. 또한 영양사는 학급의 반대표와의 정기적인 모임을 가짐으로서 학생들의 불만사항 및 개선 요구사항에대해 서로 의견을 교환하여 설문지조사가 아닌 직접적인 대화를 하여 문제점을 파악하고자 하는 적극적인 자세가 필요하겠다. 특히 아침식사의 결식 빈도가 높았고 이는 급식성과에 부정적인 영향을 줄 뿐 아니라 학교에서 제공하는 음식의 섭취정도에도 영향을 주고 있으므로 학생들에게 학부모와 전담교사 및 학교영양사는 학생들에게 이상적인 아침식사에 대한 교육은 물론이고 아침식사를 실천할 수 있도록 다양한 방안에 대해 함께 연구해야 하겠다. 정부차원에서 학교급식에 아침식사 프로그램을 도입할 수 있는 방안을 연구하고, 아침을 결식하는 학생이 학교에서 수업시작 하기 전에 간단한 식사를 할 수 있는 정책 도입이 필요하다acid의 생성량(生成量)을 측정(測定)하였는데 periodate의 소비량(消費量)은 1.23 mole, formic acid의 생성량(生成量)은 0.78 mole이다.한 경우도 비교적 많이 먹고 있었다(24.3%). 남 여

Transportation Modeling of Conservative Pollutant in a River with Weirs - The Nakdong River Case (수중보를 고려한 하천에서 보존성 오염물질의 이송특성 분석 - 낙동강을 중심으로)

  • Lee, Jungwoo;Bae, Sunim;Lee, Dong-Ryul;Seo, Dongil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.12
    • /
    • pp.821-827
    • /
    • 2014
  • The 4major river project has caused changes in flow and water quality patterns in major rivers in Korea including the Nakdong River where several toxicant release accidents have had occurred. Three dimensional hydrodynamic model, the Environmental Fluid Dynamics Code (EFDC), was applied to evaluate the effect of geomorphological change of the river on the advection and dispersion patterns of a conservative toxic pollutant. A hypothetical scenario was developed using historical data by assuming a toxic release from an upstream location. If there is a toxic release at the Gumi Industrial Complex, the toxic material would be detected after 2.22 and 9.83 days at Chilgok and Gangjung weir, respectively, in the new river system. It was estimated that they took at least 12 times longer than those with the river conditions before the project. Effect of relocation of intake towers for Daegu Metro City to upstream of Gumi City was also evaluated using the developed modeling system. It was observed that hydraulic residence time would be increased due to decreased flow rate and thus due to lowered water level. However, peak concentration differences were found to be about 2% lower in both places due to increased dispersion effect after the relocation.

Variation of Pollutant Removal Efficiency and Backwashing Effect of BAC Basin in Advanced Water Treatment Processes (고도정수공정에서 오염물질 제거효율 변화특성과 BAC조의 역세척에 따른 영향)

  • Park, Soo-Yee;Lee, Sang-Bong;Sin, Sang-Min;Jun, Chang-Jea;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.1
    • /
    • pp.45-53
    • /
    • 2008
  • In this paper, the property of influent water and variations of removal efficiencies in each unit processes were studied based on the experiment data from the advanced water treatment plant in a city of Korea. The microbial species in the biological activated carbon(BAC) after backwashing of activated carbon filtration tank(ACFT) were also identified. The property and the removal efficiencies were evaluated by considering 8-9 items. The variations of 4 items were investigated from the influent and effluent of ACFT. SEM recording were conducted on BAC samples before and after backwashing. And the existence of attached microorganisms were identified through HPC(Heterotrophic Plate Counter) investigation. For the property of influent water, the concentrations of most items were maintained in the constant ranges, some items had seasonal properties. For the removal efficiencies, there were some items showing similar monthly-pattern and increasing with time, other items decreasing at the ozone contactor. Through these investigations, it was possible to distinguish the target items, which were removed by the advanced processes. The existence of microorganisms in ACFT could be predicted based on the variation curve of NH$_3$-N, and this fact were proved by SEM and HPC.