• Title/Summary/Keyword: 이상기둥

Search Result 256, Processing Time 0.022 seconds

A Numerical Analysis of the Pressure Drop according to the Shape of TiO2 Photocatalyst-coated Module in a HVAC Duct (HVAC 덕트 내에 설치된 광촉매코팅 모듈의 형상이 압력강하에 미치는 영향)

  • Hwang, Kwang-Il;Koo, Jae-Hyoek;Kim, Da-Hye;Lee, Hyun-In;Choi, Young-Guk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1055-1062
    • /
    • 2011
  • The purpose of this study is to develop the shape of photocatalyst-coated module for improve the IAQ, which is installed at inside of ductwork and detachable. Including 3 column types(square, circle, diamond) and 2 fin types(diamond and square), totally 5 types are previously declared for numerical analysis and comparison, 5 types are. As the results of numerical analysis, almost the velocity varied at the range of ${\pm}0.3m$ from the module, except the Type A-3(diamond column type) which is affected to ${\pm}0.4m$ range and shows the biggest velocity differences. Among the 5 types, the diamond fin type(Type B-1) is analyzed as the most stable in velocity. And the results of local pressure drop show that the difference of pressure coefficient of Type B-1 is computed as 0.59, and that of Type A-3 is 2.44. Meanwhile, from the effect analysis of the number of module, the flow conflict happens and the pressure difference between before and after the module increases if there are over 3 modules inserted.

Shrinkage Stress Analysis of Concrete Slab in Multi-Story Building Considering Construction Sequence (시공단계를 고려한 고층건물 콘크리트 슬래브의 건조수축 응력해석)

  • 김한수;정종현;조석희
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.457-465
    • /
    • 2001
  • Shrinkage strains of concrete slab in multi-story building are restrained by structural members such as columns or walls, then can induce cracks due to excessive shrinkage stress over tensile strength of member. In this study, a shrinkage stress analysis method of concrete slab in multi-story building considering not only material properties such as shrinkage, creep and reinforcement effect but also construction sequence is proposed. Tensile stresses of slab due to shrinkage are calculated by converting shrinkage strains into equivalent temperature gradients, creep that can release shrinkage stress can be considered by replacing the modulus of elasticity of concrete, Ec , to the effective secant modulus of elasticity of concrete, E$\_$eff/ Reinforcements are also considered by modeling them as equivalent beam elements in FEM program. Results of step by step analysis reflecting construction sequence summed up to calculate stresses of the whole building considering that shrinkage stresses of the building come from the difference of shrinkage between i-th floor and (i-1)-th floor, named as effecitive shrinkage, and it can be varied by construction sequence. The results of 10-story example building show that shrinkage stresses of lower floors are greater than those of upper floors, that is, stresses of lower floors(1∼2FI.) exceed modulus of rupture of concrete, but stress ratios of higher floors are in the range of 27.9∼92.8%.

Comparison of Lentinula edodes Growth Characteristics According to the Amount of Paper Mulberry Sawdust Added (닥나무 톱밥 첨가량에 따른 표고 생육특성 비교)

  • Jeong, Yeun Sug;Jang, Yeongseon;Ryoo, Rhim;Ka, Kang-Hyeon
    • The Korean Journal of Mycology
    • /
    • v.46 no.3
    • /
    • pp.325-331
    • /
    • 2018
  • We aimed to increase the utility of Broussonetia kazinoki (paper mulberry) by using its woody parts as a substrate for Lentinula edodes cultivation. Using different mixing ratios of paper mulberry and oak tree sawdust, five types of column-type media were prepared (1.2 kg each). Two L. edodes strains (NIFoS 2462 and NIFoS 2778) were used in this study. In the first flush, numerous small mushrooms were harvested because the fruited mushrooms were densely packed on the small media. The highest productivity was obtained with a 3:1 mixture of paper mulberry and oak tree sawdust (Q. acutissima:Q. mongolica, 1:1). In particular, for NIFoS 2462, the proportion of paper mulberry in the medium positively correlated with productivity. The size of NIFoS 2778 was uniform in all media tested. By contrast, the mushroom weight of NIFoS 2462 decreased, but the other characteristics were not significantly affected. Collectively, these findings suggest that B. kazinoki sawdust could be used to grow shiitake mushrooms and that some oak sawdust substitution is also possible. Our results could increase the utility of discarded by-products, such as sawdust.

Fine Structure and Histopathological Changes Exposed to Acute High Salinity of the Gill of Japanese Clam, Corbicula japonica (일본재첩, Corbicula japonica 아가미의 정상구조와 고염분 급성노출에 의한 조직병리학적 변화)

  • Park, Jung-Jun;Lee, Jung-Sick;Lee, Jae-Seong
    • The Korean Journal of Malacology
    • /
    • v.27 no.1
    • /
    • pp.15-27
    • /
    • 2011
  • This study was performed to observe ultrastructure of the gill and to ascertain the effect of salinity on histopathological and ultrastructural changes in the gill of the Japanese clam, Corbicula japonica. Experimental period was 7 days. Experimental groups consisted of control, 5, 10, 20 psu. $LC_{50}$ (96 h.) by the probit was 19.55 psu. Mortality was significantly different from the control (p < 0.05). Inner demibranch of the gill of C. japonica was wider 1.37 times than outer demibranch (p < 0.001). The filament zone on the plica can be distinguished by the six epithelial celll cell; frontal ciliated epithelium ($7{\mu}m$), latero-frontal ciliated epithelium ($5{\mu}m$), postlatero-frontal epithelim ($3{\times}8{\mu}m$), and lateral ciliated epithelium ($5{\mu}m$) in the frontal zone, endothelial cellin the intermediate zone, and abfrontal cell in the abfrontal zone. It had one type of secretory cell that was filled with fibrous substances of low electron density. The gill of C. japonica exposed to 5 psu for 7 days was observed partially disappearance of the cilia, and glycogen granule in the filament. In the 10 psu, gill appeared partially modification of epithelial cell and destruction of the glycocalyx. Gill exposed to 20 psu was extended nuclus of the ciliated epithelial cell, destruction of the organelles, and observed glycogen granules infiltration and numerous vacuoles. Moreover, more than 50% filaments were observed that come out chitinous rod from disappearance of epithelial cell in the filament. Therefore, the destruction of the cilia and epithelial cell induce physiological activity and it may be leading directly to death.

The Case Study on the Erection Method of Large Span Structures (대공간 건축물 Erection 공법에 관한 사례 조사 연구)

  • Jung, Hwan-Mok;Lee, Seong-Yeun;Jee, Suck-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.97-104
    • /
    • 2007
  • Recently, the demand of the large span structures has been increasing. The large span structures include such a large scaled structures such as: the shell structure, the space frame structure, the membrane structure and the cable structure, etc. The large span structures are supposed to be confirmed and issued carefully at the initial process of the design besides the construction engineering aspects because of the structural specific cause that should solve and accomodate those large and wide space without columns. In the field of the large span structure construction, the erection construction method has been regarded as a major affected aspects on the construction cost, construction term, and stability. In the field of the large span structure construction, there are various construction method and system could be applied depends on the condition of the construction site and other circumstances such a major construction method as: the element method, the block method, the sliding method, the lift-up method and complexed method, etc. In this study, as the case study of the erection construction method of the large span structures, after survey and study that those existing large span structures construction cases which had applied and adopted the election construction method and analysis and classify into the Uoups by the size, span, ceiling height, structural system in odor to supply and suggest the data for the enhancement and development in the field of the erection construction method as a efficient structural solution of the large span structure construction.

  • PDF

Safety Evaluation of Concert Hall Floor Vibration Using Numerical Analysis Model (수치해석모델을 이용한 콘서트 홀 바닥진동 안전성 평가)

  • Roh, Ji-Eun;Heo, Seok-Jae;Moon, Dae-Ho;Lee, Sang-Hyun;Rha, Chang-Soon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.6
    • /
    • pp.469-477
    • /
    • 2017
  • In this paper, the floor vibration of an example concert hall building was measured and floor safety criteria were analytically checked through comparison between experimental and analytical results. The floor bottom plate model was constructed considering the composite effect and the analytical model was modified to have the natural frequency identical to the measured one. Also, time history analysis was conducted using the dynamic loads induced by human rhythmic movement during a musical performance, and the analytically calculated floor accelerations were similar to the measured one. Based on this model, the floor vibration level due to the group activities of about 400 persons, maximum available persons for the concert hall, was estimated. It was confirmed that the human induced dynamic loads applied to the column and beam would be much lower than the design strength. In addition, the horizontal acceleration level is just 2% of the design seismic load, so the concert hall is safe in both vertical and horizontal excitations by human rhythmic movements.

Development of Multi-span Plastic Greenhouse for Tomato Cultivation (토마토 재배용 연동 플라스틱 온실 개발)

  • Yu, In Ho;Lee, Eung Ho;Cho, Myeong Whan;Ryu, Hee Ryong;Kim, Young Chul
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.428-436
    • /
    • 2012
  • This study aimed to develop the multi-span plastic greenhouse which is suitable for tomato cultivation and is safe against climatic disasters such as typhoon or heavy snow. The width and heights of eaves and ridge of newly developed tomato greenhouse are 7, 4.5 and 6.5 m, respectively. The width is the same but the eaves and ridge heights are 1.8 and 2 m higher than conventional 1-2 W greenhouses, respectively. Cross beam has been designed as a truss structure so it can sustain loads of tomato and equipment. Tomato greenhouse has been designed according to climatic disaster preventing design standard maintaining the high height. In other words, the material dimensions and interval of materials including column and rafter have been set to stand against $40m{\cdot}s^{-1}$ of wind and 40 cm of snow. Tomato greenhouse has been equipped with rack-pinion type roof vents which have been used in glass greenhouse in order to prevent excessive rise in air temperature. This vent type is different from that of 1-2 W type greenhouse which is made by rolling up and down the vinyl at upper part of column. Roof vents are installed at ridge, and thus external air inflow and natural ventilation are maximized. As the height increases, heating cost increase as well and, therefore, tomato greenhouse has been equipped with multi-layered thermal curtain, of which thermo-keeping is excellent, to prevent heat from escaping.

Dynamic Behaviour of Masonry inFilled Reinforced Concrete Frames with Non-Seismic Details (진동대실험을 통한 비내진상세를 가지는 RC 골조의 조적채움벽 유무에 따른 동적 거동 평가)

  • Baek, Eun-Rim;Kim, Kyung-Min;Cheon, Ju-Hyun;Oh, Sang-Hoon;Lee, Sang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.121-129
    • /
    • 2017
  • In this paper, the shake table test for the masonry infilled reinforced concrete frame with non-seismic details was carried out in order to evaluate its dynamic behaviour and damage under seismic condition. The tested specimens were the RC frame and the masonry infilled RC frame and the dynamic characteristics, such as a resonant period, acceleration response, displacement response and base shear force response, were compared between them. As a result of the shake table test, RC frame specimen had flexural cracks at the top and bottom of the column and shear cracks at the joints. In the case of masonry infilled RC frame, the damage of the frame was relatively minor but the sliding cracks and diagonal shear cracks on the masonry wall were severe at the final excitation. The resonant period of infilled RC frame specimen was shorter than that of the RC frame specimen because the masonry infill contributed to increase the stiffness. The maximum displacement response of the infilled RC frame specimen was decreased by about 20% than the RC frame specimen. It was analyzed that the masonry infill wall applied in this study contributed to increase the lateral strength of the RC frame with non - seismic detail by about 2.2 times and the stiffness by about 1.6 times.

Analysis of Apparatus Variables for Deformation Strength Test of Asphalt Concrete Based on Correlation with Rutting and Prediction Model for Rutting (소성변형과의 상관성 및 추정모델을 통한 변형강도 시험장치 변수 분석)

  • Kim, Kwang-Woo;Lee, Moon-Sup;Kim, Sung-Tae;Lee, Soon-Jae
    • International Journal of Highway Engineering
    • /
    • v.4 no.4 s.14
    • /
    • pp.41-52
    • /
    • 2002
  • This study dealt with analysis of size effect of testing apparatus for Kim test which measures rut resistance characteristics of asphalt mixture under static loading. Two columns in different diameter with each column having different radios of round cut (Curvature) at the bottom were used for testing asphalt mixture. Deformation load ($P_{max}$) and deformation strength ($K_D$) were found to have relatively high correlation with rut depth and dynamic stability of asphalt concrete. Diameter of specimen was not a significant factor in this test. From the statistical correlation analysis with rutting properties, the radius of curvature and diameter of loading column were found to be important factor affecting the results of the test. Among the radios (r) of curvatures, r=0.5cm and 1.0cm showed much higher correlation than the column without curvature, and r=1.0cm being better between the two. The column with diameter of 4cm showed better correlation than diameter of 3cm. Therefore, the column of 4cm diameter with r=1.0cm was found to be the best among various apparatus sizes. Prediction models for rut depth and dynamic stability were developed for each aggregate mixture based on Kim test variables using SAS STEPWISE procedure. Therefore, if this test method is validated through further study, Kim test can be used for selecting asphalt mixture with the highest resistance against permanent deformation.

  • PDF

A Study on the Fire Spread Risk of Resident Buildings With Pilotis (필로티 건물 이격거리에 따른 화재확산 위험성 연구)

  • Choi, Seung-Bok;Choi, Doo-Chan;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.103-110
    • /
    • 2017
  • With the common tendency in the accordance with the trend, low-stories built edifices that are Pilotis-oriented structured exponentially and constantly increasing its number of buildings. It inevitably contains its risks of facing conflagrations as most of its part is used as parking lots. In the parking lots, the length of the flame has a heavy-weighted possibility that it would get increased because the heat release rate gets relatively high due to the vehicle insulation. Following on top of that, due to the nature of the Pilotisconsisting of pillars, there is a risk of flame spread to the adjacent building if the same Pilotis-structured buildings are adjacent to each other, if the flame spreads to the surroundings due to the influence of the wind. Because the most of the pilotis-structured-buildings have this entrance that makes the residents be able to enter, if the entrance were plugged the resident get a serious risk of a poisonous gas and a flame. Therefore, if the parking-lots of the pilotis-structured-buildings are adjacent to each other it requires a space to prevent the place from the spread of flame. This research studied how far is appropriate to prevent flame spreading with FDS. As a result, the study found that the distance at least 3.0 m is required.