• Title/Summary/Keyword: 이복희

Search Result 459, Processing Time 0.025 seconds

Performance Evaluation of Protection against Electric Shocks for TT and TN Systems (TT, TN접지계통의 감전보호 성능평가)

  • Lee, Bok-Hee;Choi, Young-Chul;Yoo, Jae-Duk;Shin, Hee-Kyung;Yang, Soon-Man;Kim, Tae-Gi;Lee, Zu-Cheul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.315-318
    • /
    • 2009
  • Electric shock is the accident caused by the current through a person or animal's body. That is characterized by the physiological effects. In this paper, we evaluate performance of protection against electric shocks for TT and TN grounding systems which are used by a low voltage consumer nowadays. The performance of protection against electric shocks for TT grounding system is very excellent in equipotential area of the third class grounding, but the performance is poor outside the equipotential area. The performance of protection against electric shocks for TN grounding system is excellent because the potential difference is less than 50V. Accordingly, the performance of protection for TN grounding system is good as compared with that for TT grounding System.

  • PDF

A study on the improvement of the thermal properties of ZnO arrester blocks (산화아연 피뢰기 소자의 열적 특성 향상을 위한 연구)

  • Kim, Dong-Seong;Lee, Su-Bong;Lee, Seung-Ju;Kim, Dong-Kyu;Yang, Soon-Man;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.335-338
    • /
    • 2009
  • In this study, in order to investigate the thermal and electrical properties of ZnO arrester block against 60[Hz] AC voltage, the changes in leakage current were measured. The temperature distribution appearing on the ZnO arrester blocks was observed using a forward looking infrared camera. In particular, the correlation between the thermal and electrical properties of a ZnO arrester block was analyzed experimentally. From this analysis, the thermal phenomena resulting from the heat generation and dissipation of the ZnO arrester block were interpreted. The degradation and thermal runaway phenomena of ZnO arrester block are closely related to the temperature limit of the ZnO arrester block. The installation of an additional metal electrode has resulted in the decrease of the leakage current due to the heat dissipation.

  • PDF

Determination of the Length of Coaxial Type Carbon Grounding Electrode to Minimize the Fluctuation of Grounding Impedance (접지임피던스의 변동이 최소가 되는 동축형 탄소접지전극의 길이의 산정)

  • Lee, Kang-Soo;Kim, Jong-Ho;Lee, Bock-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.164-170
    • /
    • 2010
  • For the surge currents like lightning or ground fault currents containing high frequency components which cause the electromagnetic interferences for the electronic devices and communication equipment, the grounding impedances give the significantly composite characteristics which are dependent on the frequency of surge currents. In this paper, the analytical model and method for determining the optimal length of the newly developed coaxial type carbon ground electrode which has a little fluctuation in grounding impedance with frequency. The length of minimizing the fluctuation of grounding impedance by changing frequency from 100[Hz] to 1[MHz] was determined, and the validity of this proposed method was confirmed by comparing with the simulated and measured data.

Transient impedance characteristics of counterpoise according to the soil structures (대지구조에 따른 매설지선의 과도접지임피던스 특성)

  • Lee, Bok-Hee;Li, Feng;Jung, Dong-Cheol;Kim, Ki-Bok;Cho, Sung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.311-314
    • /
    • 2009
  • This paper presents the characteristics of grounding impedance of counterpoises buried at various soil structures. Grounding impedance measurements were made by the Fall-of-Potential method. The experiments were carried out in 50 m counterpoise of 25 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the impulse generator having the front time of $1{\sim}60{\mu}s$. As a result, the soil structures greatly influences on the grounding impedance characteristics of counterpoise. The transient grounding impedances strongly depend on the injection mint and the front time of impulse current.

  • PDF

Transient Impedance of the Ground Grid and Deeply-driven Ground Rod (그리드접지와 심매설 접지전극의 과도임피던스)

  • Lee, Bok-Hee;Lee, Su-Bong;Lee, Tae-Hyung;Jung, Hyun-Uk;Jeong, Dong-Cheol;Gil, Hyoung-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.240-243
    • /
    • 2005
  • This paper presents the transient behaviors of grounding system impedance against lighting impulse currents. The dynamic characteristics of the deeply driven ground rod and grounding grid subjected to the impulse current with various rise time were investigated. It was found that the transient ground impedance strongly depends on the configuration and size of grounding electrodes and the shapes of impulse currents, and the inductance of grounding electrodes has a significant affect on the transient ground impedance of grounding system in the short time domain.

  • PDF

Experimental investigations of Breakdown Phenomena in Soils in the vicinity of Ground rod (봉형접지전극 주변에서 토중방전현상에 대한 실험적 고찰)

  • Lee, Bok-Hee;Kim, Byoung-Gun;Lee, Woo-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.279-282
    • /
    • 2005
  • Morden electronic equipments are becoming very important in information oriented society, but they are vulnerable to lightning surges. Soil resistivity in the vicinity of grounding electrodes my be affected by the current flowing from the grounding electrodes into the surrounding soil. Electrical conduction in soils depends on the grain size, compactness, and variability of the grain sizes. When a high current is injected into the soil, and the breakdown phenomenon occur. In the present work, Electrical behaviors related to discharge in soils were investigated. The breakdown voltages in soil were lower than that sparkover voltage in air. The breakdown voltage in the gravel layer is relatively low, and the breakdown was caused by the flashover through the surface of gravels

  • PDF

Protection Effects Associated with Installation Conditions of SPD (SPD의 설치조건이 보호효과에 미치는 영향)

  • Lee, Bok-Hee;Lee, Dong-Moon;Jeong, Dong-Cheol;Lee, Seung-Chil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.298-302
    • /
    • 2005
  • This paper presents the protection effect of SPDs according to installation conditions. To develop the effective protection countermeasures of information and communication equipments against lightning surges, actual-sized experiments in relation to the protection effects on the installation positions of surge protective devices(SPDs), the length of branch circuit the materials and long of conduit were conducted. The best method for protecting the electronic equipments from surges is to install the SPD at the front point of the devices to be protected. The installation method of the metal conduit bonded with common ground conductor were more effective than that of the PVC conduit.

  • PDF

Frequency Dependences of leakage currents flowing through ZnO surge arrester block (ZnO 피뢰기 소자에 흐르는 누설전류의 주파수의존성)

  • Lee, B.H.;Lee, B.;Kang, S.M.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.303-306
    • /
    • 2005
  • This paper presents the frequency-dependent characteristics of leakage currents flowing through ZnO surge arrester block. The leakage current-voltage (I-V) characteristic curves of the commercial ZnO surge arrester blocks were measured. The resistive leakage current was found to increase with increasing frequency in the low conduction region. The capacitance of ZnO block was independent of the magnitude and frequency of the applied voltage. The power losses of ZnO block increase as the frequency of applied voltage increases, because of the dielectric loss related to the frequency of the test voltage.

  • PDF

Lightning impulse characteristics of large-scale ground rods with different length (대형 봉상 접지전극의 길이에 따른 뇌 임펄스 특성)

  • Lee, B.H.;Chang, K.C.;Eom, J.H.;Kim, B.K.;Jeong, D.C.;Kil, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.233-235
    • /
    • 2003
  • To obtain a low ground resistance in high resistivity soil or in insufficient place such as downtown, long vertical ground rods are often used. However, if the lightning current or fault current with high frequency flows into the grounding system, the ground impedance is significantly increased. This paper presents how the impulse current works on the long vertical ground rods with a different length. As a result, it can be estimated what the waveform is composed of and how the GPR is affected by the rate of current change.

  • PDF

Effects of Heterostructure Electrodes on the Reliability of Ferroelectric PZT Thin Film (강유전체 PZT박막의 신뢰도에 미치는 헤테로구조 전극의 영향에 대한 연구)

  • Lee, Byoung-Soo;Lee, Bok-Hee;Lee, Duch-Chool
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.1
    • /
    • pp.14-19
    • /
    • 2003
  • The effect of the Pt electrode and the $Pt-IrO_2$ hybrid electrode on the performance of ferroelectric device was investigated. The modified Pt thin films with non-columnar structure significantly reduced the oxidation of TiN diffusion barrier layer, which rendered it possible to incorporate the simple stacked structure of Pt/TiN/poly-Si plug. When a $Pt-IrO_2$ hybrid electrode is applied, PZT thin film properties are influenced by the thickness and the partial coverage of the electrode layers. The optimized $Pt-IrO_2$ hybrid electrode significantly enhanced the fatigue properties of the PZT thin film with minimal leakage current.