Discharge Characteristics near the tip of needle in water (수중에서 침전극 끝단의 방전특성)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Park, Geon-Hun;Jun, Byung-Wook;Kim, Hoe-Gu;Beak, Young-Hwan;Lee, Kyu-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.239-241
    • /
    • 2007
  • In this paper we describe streamer propagations characterizing underwater pre-breakdown and breakdown behaviour under impulse voltages. Streamer corona branches in lower resistivities are much thicker and brighter than those in higher resistivities. The negative streamer channels not only have more branches but also widely spread out than the positive streamer channels. The succession of streamer coronas during re-breakdown produces a stepwise propagation. The pre-breakdown currents consist of the conduction current and streamer corona current pulses.

  • PDF

Influences of the electrode surface states on the spark voltage in gas discharges (기체방전에서 불꽃파괴전압에 미치는 전극표면상태의 영향)

  • 백용현;이복희;전덕규;조성욱;서국철
    • Electrical & Electronic Materials
    • /
    • v.4 no.1
    • /
    • pp.65-72
    • /
    • 1991
  • 본 논문은 전극의 표면상태가 기체방전의 전리성장과 특성에 미치는 영향에 관한 것으로 질소-산소 혼합가스중의 순수전극과 오손전극의 상태에서 전압-전류 특성과 글로우방전 개시전압을 측정하였다. 순수전극의 경우, 압력과 전극간의 거리의 곱이 8(Torr-cm)이하이고 산소의 혼입량이 0.005(%)이하일 때의 전리성장은 암류로부터 안정타운젠트방전을 거쳐 글로우방전으로 이행되었으며 글로우방전 개시전압은 거의 일정하였다. 동일의 전극표면상태에서 조차 방전개시전압은 산소혼입비에 의존하며 방전횟수에 따른 이의 변화는 산소의 함량이 0.1(%)부근에서 크게 나타났다. 방전횟수와 산소혼입량의 증가에 따른 방전개시전압의 상승은 주로 전극표면에서의 산소흡착층의 형성과 부착작용에 의한 NO, $O_{2}$, NO$_{2}$, $O_{3}$와 간은 부이온의 생성에 기인된 것으로 여겨진다.

  • PDF

Development of the Sensor for Measuring the Electric Fields (전계 측정용 센서의 개발)

  • 백용현;이복희;안창환
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.6
    • /
    • pp.630-637
    • /
    • 1991
  • For the measurement of time-varying electric fields and related quantities, a field sensor should be sensitive to the field to be measured, and also designed having an accurate transfer function. In this paper, a theoretical model which adequately describes the operation principle and design of the sensor is presented. A calibration and/or correction technique of the sensor is also studied which enables a precise determination of the response of the sensor to an electric field. As a result, the developed electric field sensor and measuring system are known to be accurate within a bandwidth from a few Hz to 200 MHz. It is found that the sensor can be used directly in the measurement of very fast transient voltages and time-varying electric fields occurring during disconnector operations in a gas-insulated substation. It may be useful also for the study on the electromagnetic environmental parameters.

A Study on the Usage Behavior of An-bang in Apartment Dwellers (아파트 거주자들의 안방 사용행태에 관한 연구)

  • 이복희;한지영;윤재웅
    • Journal of the Korean housing association
    • /
    • v.10 no.2
    • /
    • pp.185-193
    • /
    • 1999
  • This study aims to identify the usage behavior of An-bang space in apartment dwellers through the perception, the residential life style and the use of furniture. The data is collected from interviewing housewives through questionnaire designed for this study. The 210 date were analyzed by using Frequencies, Mean, Factor analysis, ${\chi}^2-test$, t-test, one-way ANOVA and scheffe-test. The main results of the study are as follows: (1) It is called An-bang' or 'large room' rather than 'master's bedroom' although it is recognized as exclusively couple-oriented space. And are founded to be different designation and perception on An-bang space. (2) The residential life style in An-bang is classified as family-centered gathered, rest entertainment, make-up fitting and hobby. And it has significant differences among dwellers according to their personal characteristics. (3) The furniture style and arrangement pattern are mostly modern ones and 'ㄷ' type.

  • PDF

A study on the sensor for measuring the transient electric fields (시변성(時變性) 전계(電界) 측정용(測定用) 센서에 관한 연구)

  • Lee, Bok-Hee;Paek, Yong-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.318-321
    • /
    • 1991
  • For measuring the transient electromagnetic fields and related quantities created by disconnector operations in GIS, one needs the wide bandwidth sensors with simple transfer functions. This paper describes a new developed electric field sensor to measure the very fast transient electric fields and voltages, and the measuring principle, design and construction of planar electric field sensor are described. A calibration and/or correction technique of the sensor is investigated which enables an accurate determination of the sensor response to the time-changing electric fields. As a consequence, the low voltage calibrations certify that a rise time of 1.7 [ns] is achieved for the planar electric field sensor and a total bandwidth extending from several Hz to 200 MHz for the measuring system which presents the constant division ratio as a function of frequency.

  • PDF

Combined ground impedance of equally-spaced n-vertical ground rods on circle (수직 접지전극의 정n각형배열의 합성 접지임피던스)

  • Seong, Chang-Hoon;Lee, Kyu-Sun;Kim, Ki-Bok;Kim, Tae-Ki;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1572-1573
    • /
    • 2011
  • 접지 저항을 줄이기 위해서 접지전극을 병렬로 시공할 경우 보다 쉽게 원하는 접지저항을 얻을 수 있다. 그러나 근접된 접지전극이 병렬로 매설되어 있을 경우 전위간섭의 영향으로 인해 합성 접지저항은 크게 감소하지 않는다. 현재의 전위간섭을 고려한 병렬접지전극의 합성 접지저항 및 합성 접지임피던스에 관한 연구는 많이 이루어지지 않았다. 본 논문에서 수직 접지전극을 정4각배열로 매설하였을 경우에 모의해석 방법을 제안하였으며 그 정확도를 평가하기 위해 실측값과 비교하였다.

  • PDF

An Analysis of Potential Interference Effects in the Vicinity of a Vertical Ground Rod (수직 접지전극 주변에서 전위간섭 영향분석)

  • Cho, Yong-Seung;Yang, Soon-Man;Yoo, Yang-Woo;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1570-1571
    • /
    • 2011
  • 인접한 독립 접지전극에 접지전류가 인가된 경우 접지전극 상호간 전위간섭을 일으키게 된다. 상용주파수 접지전류에 대한 전위간섭은 많은 분석이 이루어 졌으나, 뇌서지와 같은 고주파수를 포함하는 접지전류에 대한 전위간섭의 분석은 충분히 수행되지 못하였다. 본 논문에서는 상호간 영향을 줄 수 있는 길이 4 m인 수직 접지전극을 대상으로 주파수에 따른 전위간섭의 영향을 분석하였으며, 수직 접지전극의 주변에 나타나는 대지표면전위와 함께 상호 비교 분석하였다. 그 결과, 전위간섭은 접지임피던스의 변화에 의존하는 경향성을 나타내었으며, 수직 접지전극 길이의 1.5배에 해당하는 이격거리에서 접지전극의 전위와 대지표면전위가 거의 일치하는 것으로 나타났다.

  • PDF

Analysis of Lightning Current Distribution for Reducing the Conductive EMI in a Structure (도전성 EMI 저감을 위한 구조체의 뇌격전류 분류율 분석)

  • Cho, Sung-Chul;Lee, Tae-Hyung;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1630-1631
    • /
    • 2011
  • Lightning current distribution in a building directly hit was studied by using a scaled steel frame structure model. As the test current source, impulse current with the rise time of 10 ${\mu}s$ and sinusoidal current with the frequency of 30 kHz were used to confirm the validity of test results. The current distributions at both horizontal and vertical pillars were measured by using CT. From the test results, the reduction effect for the conductive EMI was verified and a design method reducing the conductive EMI was proposed.

  • PDF

Ground impedance of deeply driven rod in high frequency domain (고주파수 영역에서 심매설 접지전극의 접지임피던스)

  • Lee, Bok-Hee;Lee, Tae-Hyung;Lee, Su-Bong;Jeong, Hyun-Wook;Jeong, Dong-Cheol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.247-250
    • /
    • 2004
  • A ground resistance is a good index of performance in a grounding system, but it does not reflect the performance in transient states. Recently long vertical ground rods in urban areas are often installed. But because of the inductance of long ground rods the ground impedance at high frequency might be greater than its resistance at low frequency. In this paper, a ground impedance of deeply driven ground rod has been measured in the frequency range from 10 kHz to 50 MHz. As a result, the ground impedances of a deeply driven ground rods are almost constant at the frequency range less than 100 kHz. However at high frequency the ground impedance showed the strong frequency dependance.

  • PDF

Personnel safety related to a loss of PEN conductor in TN-C-S system (TN-C-S계통에서 PEN도체 단선이 인체안전에 미치는 영향)

  • Kim, Jung-Cheol;Lee, Bok-Hee;Lee, Kyu-Sun;Joe, Jung-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.59-62
    • /
    • 2009
  • In electrical power supply systems, an earthing system determines the electrical potential of the conductors relative to that of the Earth's conductive surface. The choice of earthing system has implications for the safety of the power supply. Note that regulations for earthing (grounding) systems vary considerably among different countries. A protective earth(PE) connection ensures that all exposed conductive surfaces are at the same electrical potential as the surface of the Earth, This paper investigates that when PEN conductor of TN-C-S system is disconnected, dangerous touch voltage is caused at personnel body. According to this paper, we can understand that when TN-C-S system is applied in Korea, what we should set up to ensure the personnel safety from fault current.

  • PDF