• 제목/요약/키워드: 이복희

검색결과 459건 처리시간 0.026초

다중 낙뢰에 의하여 발생하는 전계와 자계의 통계적 특성 (Statistical Characteristics of Electric and Magnetic Fields Produced by Multiple-Lightning Return Strokes)

  • 이복희;안창환;성준환;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2158-2160
    • /
    • 1999
  • In order to obtain the detailed informations about the lightning electromagnetic fields, the electric and magnetic fields radiated by lightning return strokes were observed with the electric field sensor of hemi-sphere type and the magnetic field sensor of loop type and their physical characteristics were statistically analyzed. The multiple stroke occurrence numbers was 2.6. In multiple lightning strokes the amplitude of peak and the time interval between the subsequent strokes were decreased as the number of the subsequent strokes increases.

  • PDF

다중 뇌방전에 의하여 발생하는 전계 변화의 특성 (Characteristics of Electric Field Change Associated with Multiple-Lightning Discharges)

  • 이복희;안창환;이승칠;심판섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1650-1652
    • /
    • 1998
  • This paper describes characteristics of electric field waveforms associated with multiple-lightning discharges. The electric field measurment system. consists of hemi-sphere antenna 30 cm in diameter. integrator and data acquisition device. The frequency bandwidth is from 200 Hz to 1.56 MHz, and the sensitivity is 0.96 mV/V/m. The detected electric field signal is digitized every 500 ns with the resolution of 12-bit and the length of 2 kilowords and is registered at a personal computer. Also parameters of the electric fields associated with multiple-lightning discharges are ststistically analyzed.

  • PDF

22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of electric and magnetic fields in the vicinity of 22.9[kV] Distribution Line)

  • 이복희;길형준;안창환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1653-1655
    • /
    • 1998
  • In this paper, measurement and analysis of ELF electric and magnetic fields in the vicinity of 22.9[kV] distribution line have been performed. The height of measuring point from the earth's surface was 1[m], and the distance between the device and the operator was more than 3[m]. The experiments have been carried out by lateral profile, and we have made use of FIELDS program for the sake of comparision the experimental data with the theoretical value. Electric and magnetic fields intensity were strong under a distribution line, and were inversely proportional to lateral distance. The profiles of electric field were M shape and those of magnetic field were $\cap$ shape. Electric and magnetic fields intensity were increased with increasing the measurement height.

  • PDF

뇌격거리측정계 및 뇌방전에 의해 발생하는 전장의 스펙트럼 분석 (Measurement System of a Distance from Lightning Strokes to Observatory and Spectrum Analysis of Electric Fields Radiated from Lightning Discharges)

  • 이복희;장석훈;정광희;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1656-1658
    • /
    • 1998
  • This paper deals with a measurement system of a distance between lightning strokes and observatory station and spectrum analysis of electric fields radiated from lightning discharges. The distance measurement system, which consists of a loop type magnetic field sensor, a microphone and one chip microprocessor, is connected to a personal computer through RS232 port to acquire and process the data. This system is to use a difference of propagation velocity between an electromagnetic wave and a sonic wave produced by lightning discharge. Also, an electric field waveform and a frequency spectrum were investigated by an electric field measurement system with a hemisphere antenna and a spectrum analyzer with a biconical antenna and a log-periodic antenna, respectively. The results would be used as a basic reference to protect the power systems and electric circuits from lightning overvoltages.

  • PDF

PFN을 이용한 펄스발생기의 연구 (A Study on the Pulse Generator using PFN)

  • 이복희;정관모;박종순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1773-1775
    • /
    • 1998
  • This paper deals with the pulse generator using PFN(Pulse Forming Network), and its operation characteristics and application. Two kinds of pulse generator were composed of the best appropriate condition circuit. The output current of the one pulse generator has the rise time of 28 ns and the pulse duration of $7{\mu}s$. The other pulse generator has high current of about 2kA. By use of the former generator with rapid rise time, the impulse impedance characteristic of ground electrodes was investigated with measuring the ground potential rise when the pulse current was injected into the ground electrode.

  • PDF

임펄스 전류에 대한 대규모 접지시스템의 과도접지임피던스 (Transient Impedance of Large-scale Grounding System under Impulse Current)

  • 이복희;엄주홍;이승칠;최원규;박종순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1589-1591
    • /
    • 1998
  • This paper presents experimental results of transient impedance characteristics investigated on the site of a large-scale grounding system using impulse current. The ground potential rise was measured while injecting an impulse current and the transient impedance was determined. As a results, the transient impedance was significantly greater than the stationary grounding resistance due to high inductance of ground conductors and leads.

  • PDF

누설전류의 제3고조파 분석에 의한 ZnO소자의 열화진단기술 (A Technique of Deterioration Diagnosis for ZnO Element by Analyzing the 3rd order Harmonics- of Leakage Current)

  • 이복희;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1740-1742
    • /
    • 1998
  • This paper describes the technique of deterioration diagnosis for ZnO element. Due to the non-linear resistance of ZnO block, the total leakage current contains harmonics when arrester deteriorated. The most significant harmonics is the 3rd order component. So, it can be used as an indicator of the arrester condition. An iron core, which has a very high relative permeability, is used for increasing detection sensitivity and the 3th order harmonics of leakage current was detected by band-pass circuit. And we have verified the reliability and performance of the sensing device through several laboratory tests.

  • PDF

배전용 변압기를 통한 저압전원선으로의 뇌서지 전파 (Propagation of Lightning Surges on Power AC Lines through Distribution Transformers)

  • 이복희;이수봉;이동문
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.468-471
    • /
    • 2002
  • A strong need to improve the quality of electric power is increased because of increasing use of the sensitive and small-sized electronic devices. The surges on the low-voltage ac power lines are induced by nearby lightning return strokes, and the facilities for HA, OA, FA, ME as well as computer are easily damaged by high-voltage transients. The behaviors of lightning surge characteristics transferred from the primary winding to the secondary winding in distribution transformers using a Marx generator were experimentally investigated. The transfer characteristics of lightning surge associated with a custom service ground of secondary side were also examined.

  • PDF

전류구동형 서지카운터 (Current Driving Type Surge Counter)

  • 이복희;안창환;장석훈;정관모;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1712-1714
    • /
    • 1997
  • This paper deals with the surge counter drived by lightning and switching currents. In order to install the effective surge protective devices, it is important to find the parameters of incident surges. In this paper, for the purpose of protecting the electronic circuits and counting the occuring frequency, the current driving type surge counter is designed and fabricated. The surge counter consists of surge protective divices, current detector, metal oxide varistor(MOV), rectifier, capacitor, and electromagnetic counter. This surge counter is able to count the occuring frequency of surges and to clamp lightning surge current. To evaluate the performance of the surge counter, impulse voltage and current were applied at the surge counter by the surge generator. As a result, applied surges were exactly counted and clamped.

  • PDF

봉상접지극의 임펼스 전류에 대한 과도접지임피던스 특성 (Characteristics of Transient Grounding Impedances of Rod Electrodes)

  • 이복희;박종순;양정재;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1645-1647
    • /
    • 1997
  • Electronic circuits are becoming more vulnerable owing to the development of integrated circuit. Computer and info-communication facilities are very sensitive to surges caused by lightning, and they can suffer a malfunction and damage. Recent concern about damage and upset caused by transient overvoltages has focused on surge protection. The most important parameter in surge protection is the transient grounding impedance. In this paper, the transient grounding impedances of a rod electrode have been measured under impulse current waves. Z-t, Z-i and V-i characteristics of the grounding electrode in according to the length of the grounding lead wire were obtained and analyzed.

  • PDF