• Title/Summary/Keyword: 이미지 교정

Search Result 73, Processing Time 0.025 seconds

Effect of Anteromedial Cortex Oblique Angle on Change of Tibial Posterior Slope Angle in High Tibial Osteotomy Using Computer Assisted Surgery (CAS) (Computer Assisted Surgery(CAS)를 이용한 개방형 근위경골절골술 시 전내측피질골경사각이 경골후방경사각에 미치는 영향)

  • Lee, Ho-Sang;Kim, Jay-Jung;Wang, Joon-Ho;Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.351-361
    • /
    • 2012
  • The leading surgical method for correcting the misalignment of the varus and valgus in the knee joint is the high tibial osteotomy (HTO). In the opening wedge HTO (OWHTO), there is no concern about damaging the peroneal nerve on the lateral tibia of the proximal fibula. OWHTO has been the preferred choice, as the opening of the correction angle can be modulated during the operation. The correction of the varus and valgus on the coronal plane are performed adroitly. Nevertheless, there have been numerous reports of unintended changes in the medial tibial plateau and posterior slope angle (PSA). The authors have developed an HTO method using computer-assisted surgery with the aim of addressing the abovementioned problems from an engineer's perspective. CT images of the high tibia were reconstructed three-dimensionally, and a virtual osteotomy was performed on a computer. In addition, this study recommends a surgical method that does not cause changes in the PSA after OWHTO. The results of the study are expected to suggest a clear relationship between the anteromedial cortex oblique angle of each patient and the PSA, and an optimal PSA selection method for individuals.

Measurement of two-dimensional vibration and calibration using the low-cost machine vision camera (저가의 머신 비전 카메라를 이용한 2차원 진동의 측정 및 교정)

  • Kim, Seo Woo;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.2
    • /
    • pp.99-109
    • /
    • 2018
  • The precision of the vibration-sensors, contact or non-contact types, is usually satisfactory for the practical measurement applications, but a sensor is confined to the measurement of a point or a direction. Although the precision and frequency span of the low-cost camera are inferior to these sensors, it has the merits in the cost and in the capability of simultaneous measurement of a large vibrating area. Furthermore, a camera can measure multi-degrees-of-freedom of a vibrating object simultaneously. In this study, the calibration method and the dynamic characteristics of the low-cost machine vision camera as a sensor are studied with a demonstrating example of the two-dimensional vibration of a cantilever beam. The planar image of the camera shot reveals two rectilinear and one rotational motion. The rectilinear vibration motion of a single point is first measured using a camera and the camera is experimentally calibrated by calculating error referencing the LDV (Laser Doppler Vibrometer) measurement. Then, by measuring the motion of multiple points at once, the rotational vibration motion and the whole vibration motion of the cantilever beam are measured. The whole vibration motion of the cantilever beam is analyzed both in time and frequency domain.

Full-field Distortion Measurement of Virtual-reality Devices Using Camera Calibration and Probe Rotation (카메라 교정 및 측정부 회전을 이용한 가상현실 기기의 전역 왜곡 측정법)

  • Yang, Dong-Geun;Kang, Pilseong;Ghim, Young-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.6
    • /
    • pp.237-242
    • /
    • 2019
  • A compact virtual-reality (VR) device with wider field of view provides users with a more realistic experience and comfortable fit, but VR lens distortion is inevitable, and the amount of distortion must be measured for correction. In this paper, we propose two different full-field distortion-measurement methods, considering the characteristics of the VR device. The first is the distortion-measurement method using multiple images based on camera calibration, which is a well-known technique for the correction of camera-lens distortion. The other is the distortion-measurement method by measuring lens distortion at multiple measurement points by rotating a camera. Our proposed methods are verified by measuring the lens distortion of Google Cardboard, as a representative sample of a commercial VR device, and comparing our measurement results to a simulation using the nominal values.

Prediction of frontal soft tissue changes after mandibular surgery in facial asymmetry individuals (안면비대칭자의 하악골 악교정수술 후 정면 연조직 변화 예측을 위한 연구)

  • Hwang, Hyeon-Shik;Lee, Jessica J.;Hwang, Chung-Hyon;Choi, Hak-Hee;Lim, Hoi-Jeong
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.252-264
    • /
    • 2008
  • Objective: To aid the development of a frontal image simulating program, we evaluated the soft tissue frontal changes in relationship to movement of hard tissue with orthognathic surgery of facial asymmetry patients. Methods: Preoperative and postoperative frontal cephalograms and frontal view photographs of 45 mandibular surgery patients with facial asymmetry were obtained in a standardized manner. Vertical and horizontal changes of hard tissue and soft tissue were measured from cephalograms and photographs, respectively. Soft tissue change in result to hard tissue change was then analyzed. Results: Both vertical and horizontal correlation analysis showed a weak relationship between the changes. Hard tissue points that were picked for 1 : 1 mean ratio with soft tissue points did not show any significant relevance. For each soft tissue change, regressive equation was formulated by stepwise multiple regression analysis, and the equation for soft tissue Menton was most reliable in predicting changes. Both vertical and horizontal hard tissue changes were used together in prediction of vertical or horizontal soft tissue change. Conclusions: The results suggest that computerized image simulation using regression analysis may be of help for prediction of soft tissue change, while 1:1 mean ratio method is not useful.

A Study on the Educational Necessity and Activation Plan of Image Making Program for Life Care (라이프케어를 위한 이미지메이킹 프로그램 교육의 필요성과 활성화 방안)

  • Yoon, Hee
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.429-437
    • /
    • 2020
  • This study is aimed at exploring the current state, necessity and activation of curriculum related to image making program in domestic colleges. To achieve this, an empirical survey was carried out to college students to provide basic data for the development of image making education program in the college curriculum as a measure to guide job interviews with them and improve interpersonal skills of employees-to-be. To achieve this, a survey was carried out to 400 college students in Gwangju and Jeonnam areas. The analysis was conducted to verify the collected data using SPSS v. 21.0 through the process of data coding and data cleaning. The results are as follows. First, the necessity of image making program curriculum showed that they needed the image making program in the college curriculum, the image making program curriculum to get a job and manage an image of employees-to-be after graduation, and other people's help to figure out the images objectively. Second, the educational importance of image making program showed that attitude (behavior) was the highest, followed by manners & greeting, look, speech, relationship, clothes, hairstyle, and makeup. In terms of the important educational factors of image making program, look was the highest, followed by makeup, hairstyle, attitude (behavior), relationship, speech, clothes, and manners & greeting, which look was the most important. Third, the educational influence of image making program showed that the influence on employment was the highest, followed by the influence on relationship, and the influence on life. Fourth, the educational activation of image making program showed that the appropriate educational time for image making program they want was from the second year. Education hours they want were once a week for one semester. And the curriculum they want was liberal arts or an optional course of liberal arts. In terms of image making program-related curriculum contents, manner & greeting was the highest, followed by makeup & coordination, job fair, education to acquire a skill qualification, and training for domestic companies, which their biggest wish was manner & greeting. And image making program leaders they want were major professors. In terms of image making program-related education, speech or voice was the highest, followed by education to analyze communication, education to analyze and practice matching hairstyles and makeup, Education on corporate interviews, and education on walking or posture correction, which their biggest wish was speech or voice and education to analyze communication.

An Anatomical Study using CT Images for the Implantation of Micro-implants (CT 이미지를 사용한 Micro-implants 식립을 위한 매부학적 연구)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.435-441
    • /
    • 2002
  • Surgical microscrews were introduced and used as one method to provide absolute anchorage. Some clinicians implanted microscrews or miniscrews into the basal bone below the roots of the teeth to evade damage to the roots. Because the implanted microscrews were positioned too low the applied force was insufficient to retract the anterior teeth or protract the posterior teeth, and the use of microscrews or miniscrews seemed limited in applying vertical force. However Park implanted microscrews(micro-implants (1.2mm in diameter)) into the alveolar bone between the roots of the posterior teeth to change the direction of the applied force toward increasing horizontal component of the force. Moreover, these microscrew implants were positioned in the alveolar bone between the roots without causing discernable damage to the roots. This study was performed to provide guidelines and anatomic data to assist in the determination of the safe location for micro-implants. By measuring the CT images from 21 patients, anatomical data were obtained which were then used as a guide to determine the location for the implantation of micro-implants. The thickness of the cortical bones at the alveaolar bone region increased from the anterior to the posterior teeth area. The mandibular posterior teeth area showed thicker cortical bone. A greater distance was observed in distance between the second premolar root and first molar root in the upper arch, between the first molar root and the second molar root in the lower arch. The alveolar bone of the posterior teeth area is considered the best site for the implantation of micro-implants.

The establishment of orthodontic web server multimedia database system for continuing education (임상교정 교육용 멀티미디어 데이터베이스 웹서버 구축에 관한 연구)

  • Park, Jae-Woo;Lee, Jong-Ki;Chang, Young-Il;Nahm, Dong-Suk;Kim, Myung-Ki;Yang, Won-Sik;Kim, Tae-Woo;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.245-260
    • /
    • 2000
  • The Objective of this research was to construct the multimedia database system that was necessary for the education of the practitioners and the students. To establish this system, there were technical problems as follows 1) The processing of the images, 2) The rapid processing of the information with the computer network, 3) The development of diagnosis tools, 4) The technique to establish the database system, 5) The link between the database system and the internet, and 6) The method to educate through many cases. The analysis for diagnosis and treatment planning were provided as two parts : model analysis and cephalometric analysis. As a model analysis, arch length discrepancy and Bolton tooth ratio were provided for the part of patient information. Cephalometric analyses were provided in the part of initial diagnosis. The Cephalometric analysis ver 2.0 and the PowerCeph pro 3.3.5 were used to show Tweed, Steiner and Jarabak analysis. In the main part, Kim's analysis and some measurements were added. In the post-treatment or retention part, we show the superimposition of the cephalometrics with which you can find the effectiveness of the various orthodontic treatment The address of this home page is "http://damis.snu.ac.kr/orthodontics"

  • PDF

Development of Automatic Nut Inspection System using Image Processing (이미지 프로세싱을 이용한 자동 너트 검사 장비 개발)

  • Lee, Sang-Hak;Seo, Myong-Ho;Chung, Tae-Choong
    • The KIPS Transactions:PartA
    • /
    • v.11A no.4
    • /
    • pp.235-242
    • /
    • 2004
  • When manufacturing information and communication device that consists of lots of part, it is important to improve the quality of the produced system by inspecting the system accurately and exclude the defected part. In case of LCD which is recently in a great demand, the inspection process of the nut which bonds the back frame to protect the LCD panel has to be done by human labor. It highly required an automatic inspection system which can inspect the nut without wasting human resources. In this paper, we describe the process of developing a system which automatically inspect the status of nuts inserted during the manufacturing of LCD. The nut inspection vision system developed measures the number of nut's spiral, the distance between pitches, the width of a pitch, and the inside diameter of nut. We have adopted lens with high magnifying power and calibration tool and intended to produce automatic lighting for maintaining a stable environment for a high precision system. We also developed the algorithms for analyzing the nut. We apply the system to real factory field and verify that it is better than the man power in terms of error rate.

Evaluation on the Accuracy of the PPS in the Proton Therapy System, Which Uses the Self Made QA Phantom (자체 제작한 QA Phantom을 이용한 양성자 PPS (Patient Positioning System)의 정확성 평가)

  • Lee, Ji-Eun;Kim, Jae-Won;Kang, Dong-Yoon;Choi, Jae-Hyeok;Yeom, Du-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.115-121
    • /
    • 2012
  • Purpose: The process of the proton treatment is done by comparing the DRR and DIPS anatomic structure to find the correction factor and use the PPS to use this factor in the treatment. For the accuracy of the patient set up, the PPS uses a 6 axis system to move. Therefore, there needs to be an evaluation for the accuracy between the PPS moving materialization and DIPS correction factor. In order to do this, we will use a self made PPS QA Phantom to measure the accuracy of the PPS. Materials and Methods: We set up a PPS QA Phantom at the center to which a lead marker is attached, which will act instead of the patient anatomic structure. We will use random values to create the 6 axis motions and move the PPS QA Phantom. Then we attain a DIPS image and compare with the DRR image in order to evaluate the accuracy of the correction factor. Results: The average correction factor, after moving the PPS QA Phantom's X, Y, Z axis coordinates together from 1~5 cm, 1 cm at a time, and coming back to the center, are 0.04 cm, 0.026 cm, 0.022 cm, $0.22^{\circ}$, $0.24^{\circ}$, $0^{\circ}$ on the PPS 6 axis. The average correction rate when moving the 6way movement coordinates all from 1 to 2 were 0.06 cm, 0.01 cm, 0.02 cm, $0.1^{\circ}$, $0.3^{\circ}$, $0^{\circ}$ when moved 1 and 0.02 cm, 0.04 cm, 0.01 cm, $0.3^{\circ}$, $0.5^{\circ}$, $0^{\circ}$ when moved 2. Conclusion: After evaluating the correction rates when they come back to the center, we could tell that the Lateral, Longitudinal, Vertical were all in the acceptable scope of 0.5 cm and Rotation, Pitch, Roll were all in the acceptable scope of $1^{\circ}$. Still, for a more accurate proton therapy treatment, we must try to further enhance the image of the DIPS matching system, and exercise regular QA on the equipment to reduce the current rate of mechanical errors.

  • PDF

A Design and Implementation of Taegwondo Poomsae Verification Application (태권도 품새 검증 어플리케이션 설계 및 구현)

  • Lee, Won Joo;Jang, Byung Woon;Yu, Ho Sang
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.37-38
    • /
    • 2016
  • 본 논문에서는 Kinect 센서 기반의 태권도(Taegwondo) 품새(Poomsae) 검증 어플리케이션을 설계하고 구현한다. 이 어플리케이션은 는 태권도 품새 검증 어플리케이션으로 태권도 품새 태극 1장을 설계 구현한다. Kinect 센서를 통하여 측정한 사용자의 스켈레톤(skeleton) 위치 정보와 태권도 품새 기본 가이드를 비교함으로써 사용자의 자세와 태권도 품새 기본 가이드의 차이값을 측정한다. 이 측정값의 차이에 따라 기본 점수에서 감점하여 사용자의 품새 정확도를 점수로 산정할 수 있다. 또한 사용자는 Kinect 센서를 통하여 전송된 자신의 품새 이미지와 기본 품새 가이드의 차이를 보고 자신의 품새를 교정할 수 있다.

  • PDF