• Title/Summary/Keyword: 이류체

Search Result 45, Processing Time 0.022 seconds

A Study on the Level-Set Scheme for the Analysis of the Free Surface Flow by a Finite Volume Method (유한체적법에 의한 자유수면 유동해석에서 Level-Set 기법에 대한 연구)

  • Il-Ryong Park;Ho-Hwan Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.2
    • /
    • pp.40-49
    • /
    • 1999
  • A Finite Volume Method for the two-dimensional incompressible, two-fluids Navies-Stokes equation and level-set scheme are used to analyse the interface of two fluids, free-surface flow. The numerical characteristics and the applicability of level-set scheme are brief1y investigated and appraised by solving oscillating small surface wave in a water tank and dam break problems. In the numerical results, a method for improving the convergence of the solution is presented.

  • PDF

A Study on the Development of Two-phase Nozzle Suitable for Multi-purpose Spraying in Orchards (과수원 내 다목적 살포에 적합한 이류체 노즐 개발에 관한 연구)

  • Han, Kwang Ho;Kang, Tae Gyoung;Lee, Dong In;Lee, Chul-Hee
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.1-7
    • /
    • 2020
  • In orchard or crop-growing environments, pesticides are sprayed using various nozzles to prevent pests and improve productivity. Nozzles currently in use are restricted for use in multi-purpose environments, thus, it is necessary to develop new nozzles. In this study, new two-phase nozzles are proposed to improve the performance of the nozzle (flow rate, spray angle, spray particle size). The performance of the two-phase nozzles are predicted through the CFD analysis and the performance of the nozzles is compared with the experiment. The experimental results showed that the proposed two-phase nozzles are available at relatively low operating pressure condition and are capable of extensive spray particle size control. Thus, the proposed nozzles are expected to be available in various orchard environments.

Pulverized Coal Particle Presence Inside CWM Droplet (CWM 방울안의 미분탄 존재)

  • 김종호;김성준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.5
    • /
    • pp.1211-1221
    • /
    • 1990
  • The purpose of this study is to get experimental data on the distribution of CWM (Coal- Water Mixture) droplets size and the presence of pulverized coal particles inside CWM droplets. Atomization of CWM is done by Twin-Fluid Atomizer. The operational parameters are atomizing air pressure, coal particle loading, mean size of pulverized coal particles and sampling positions across spray. Th data analysis is initiated by Impression Sampling Method(Magnesium Oxide Technique) and Photo-technique and counting works are followed. Experimental work induces following research results. The variation of particle loadings in slurry makes no appreciable effects on the mean size of CWM droplets. It is evident that atomizing air pressure has very strong effect on the atomization of slurry. The mean size of atomized fuel droplets is dramatically reduced with the increasing air pressure. The population ratio of droplets without coal particles to total number of droplets is decreased as atomizing air pressure or loading rises and the same trend is obtained as the mean size of coal particles becomes smaller but a certain tendency of coal particle presence inside droplets could not be found from the change of sampling positions.

Spray modelization of air-assisted coaxial atomizer (이류체 분사노즐의 분무예측 모델)

  • Yun, Seok-Ju;Ledoux, M.
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.6
    • /
    • pp.1948-1958
    • /
    • 1996
  • Experimental and theoretical studies on the air-assist coaxial atomizer have been continuously carried out for a long time. But now the importance of the theoretical study is tending to increase as with the development of computer. This study is concerned to the spray modelization, especially, the instability of the liquid jet surrounded by the air stream which flows with high velocity. To study the phenomena of the break up, we used the linear theory based on the classical Kelvin-Helmholtz theory for capillary wave at a simple interface and we investigated the variation of liquid core radius. As a result, we obtained that the drop diameter and the variation of the liquid core radius predicted by using our model are reasonable.

Feature of Spray Transport and Atomization from Two-Phase Swirling Jet with Air-to-Liquid Mass Ratio (공기액체질량비에 따른 이류체 선회형 분사의 분무거동 및 미립화 특성)

  • Lee, Sam-Goo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.39-45
    • /
    • 2004
  • Experiments were performed in a two-phase swirling spray facility that has been described elsewhere. Measurements of spray transport and drop size distribution are analyzed over wide ranges of air to liquid mass flow ratios, utilizing four different internal mixing pneumatic nozzles. The spatial distributions of mean velocities. fluctuating velocities, and velocity-diameter correlation were quantitatively analyzed. Also, the exponential correlation curves were obtained with ALR along the spray centerline, which indicated an approximately identical formulation regardless of ALR. It indicated that the atomization characteristics were remarkably superior in the case of 30o of swirl angle with higher ALR. Among other things. nozzle configuration is one of the significant parameters affecting spray phenomena from an internal mixing nozzle. Turbulence intensities are increasingly degenerated with an increase of nozzle configuration, allowing a rapid increment of drop size distribution.

Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System (이류체 포그 냉방시스템의 제어알고리즘 개발)

  • Nam, Sang-Woon;Kim, Young-Shik;Sung, In-Mo
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.138-145
    • /
    • 2013
  • In order to develop the efficient control algorithm of the two-fluid fogging system, cooling experiments for the many different types of fogging cycles were conducted in tomato greenhouses. It showed that the cooling effect was 1.2 to $4.0^{\circ}C$ and the cooling efficiency was 8.2 to 32.9% on average. The cooling efficiency with fogging interval was highest in the case of the fogging cycle of 90 seconds. The cooling efficiency showed a tendency to increase as the fogging time increased and the stopping time decreased. As the spray rate of fog in the two-fluid fogging system increased, there was a tendency for the cooling efficiency to improve. However, as the inside air approaches its saturation level, even though the spray rate of fog increases, it does not lead to further evaporation. Thus, it can be inferred that increasing the spray rate of fog before the inside air reaches the saturation level could make higher the cooling efficiency. As cooling efficiency increases, the saturation deficit of inside air decreased and the difference between absolute humidity of inside and outside air increased. The more fog evaporated, the difference between absolute humidity of inside and outside air tended to increase and as the result, the discharge of vapor due to ventilation occurs more easily, which again lead to an increase in the evaporation rate and ultimately increase in the cooling efficiency. Regression analysis result on the saturation deficit of inside air showed that the fogging time needed to change of saturation deficit of $10g{\cdot}kg^{-1}$ was 120 seconds and stopping time was 60 seconds. But in order to decrease the amplitude of temperature and to increase the cooling efficiency, the fluctuation range of saturation deficit was set to $5g{\cdot}kg^{-1}$ and we decided that the fogging-stopping time of 60-30 seconds was more appropriate. Control types of two-fluid fogging systems were classified as computer control or simple control, and their control algorithms were derived. We recommend that if the two-fluid fogging system is controlled by manipulating only the set point of temperature, humidity, and on-off time, it would be best to set up the on-off time at 60-30 seconds in time control, the lower limit of air temperature at 30 to $32^{\circ}C$ and the upper limit of relative humidity at 85 to 90%.

Spray Control System Development of Two-Flow Nozzle to Control Spraying Rate and Droplet Size Independently (분무량과 분무입경의 독립적 제어를 위한 이류체노즐 제어시스템 개발)

  • 안형철;이중용;정창주;이종인
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1999.07a
    • /
    • pp.22-27
    • /
    • 1999
  • 최근 정밀농업기술의 중요성이 인식되면서 점살포, 직접살포, 또는 방제목표물의 크기에 따른 분무량 조절 등의 기술이 개발되고 있으나 모든 기술이 분무량 조절에만 치중되어 있다. 일반적인 수압식 노즐의 경우에 분무압을 이용하여 분무량을 제어하면 분무입자의 크기가 적정 이외의 크기로 살포되어 효율적인 방제효과를 얻기가 어렵다. 하나의 제어인자 즉 분무압만을 이용하여 두 가지의 특성 즉 분무량과 분무입자의 크기를 조절하는 것은 이론적으로 불가능하다 정밀방제에 있어 분무입경과 분무량을 독립적으로 조절할 수 있으려면 두 가지 제어인자를 가진 노즐을 이용해야만 가능하며 이러한 범주에 속하는 노즐로는 원심노즐과 이류체노즐, 정전화노즐 등이 있다. (중략)

  • PDF

Development of Control System of Twin-Fluid Nozzles for Controlling Spraying Rate and Droplet Size (이류체노즐을 이용한 분무량과 분무입경 제어시스템 개발)

  • 이중용;안형철;정창주
    • Journal of Biosystems Engineering
    • /
    • v.25 no.1
    • /
    • pp.11-18
    • /
    • 2000
  • In precision chemical application increment of biological efficacy with less chemical is the virtue. spraying rate and droplet size is closely related to biological efficacy. this study was performed to develope a spray-control-system that could control spraying rate and droplet size independently. Twin-fluid nozzles were selected and tested to certify if the nozzles were suitable for the objective of this study. Characteritics of the nozzles i.e., spraying rte and droplet size change u8nder the changes of spraying pressure and air pressure were statistically modeled. The model had I to 1 matching property between dependent variables and independent variables. Using the property and the model, inverse relationship could be determined between variables. A feedback spray control system was developed and tested with predetermined error of 5 % in pressure. The system showed 4 % error in spraying rate and 9 % error in droplets size. Performance of the system could be upgraded by fine tuning but, in practical sense keeping air pressure in the field sprayer was the bottle neck of commercialization of the spray system.

  • PDF

Preparation of α-Al2O3 Nanoparticles by flame Spray Pyrolysis (ESP) of Microemulsion (마이크로에멀전의 화염분무열분해(ESP)에 의한 α-알루미나 나노입자의 제조)

  • 이상진;전병세
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.3
    • /
    • pp.242-246
    • /
    • 2004
  • Nano-sized a-alumina with a narrow distribution was prepared by using Flame Spray Pyrolysis (FSP). The microemulsion of water in oil (W/O) was prepared to make ultrafine droplets for FSP process. Kerosene (fuel) as a continuos phase and Al(NO$_3$)$_3$$.$9$H_2O$ (oxidizer) aqueous solution as a dispersed phase were prepared for microemulsification. The microemulsion with dispersion stability was obtained by adjusting the composition of 80 vol% kerosene, 10 vol% aqueous solution, and 10 vol% emulsifying agent. Microemulsion was sprayed onto the flame by using two-fluid nozzle spray gun under the condition of 0.03 ㎫ air pressure. The synthesized products were $\alpha$-alumina phase with the size of 20 to 30 nm.

Study on $SF_6$ hydrate Formation and Dissociation Behavior inside of Bench-scale High Pressure Reactor (Bench-scale 고압반응기 내의 미세액적분사에 따른 $SF_6$ 하이드레이트 형성 거동 연구)

  • Moon, Dong-hyun;Lee, Jae-jeong;Shin, Hyung-Joon;Lee, Ju-Dong;Lee, Gang-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.687-690
    • /
    • 2009
  • 본 연구에서는 가스 하이드레이트 형성과정에서 발생할 수 있는 유도지체시간을 줄이고 전체 가스 저장량과 반응 속도의 향상을 위하여 이류체 분사 방식을 이용하여 물분자의 액적을 최소화하는 실험을 통하여, 미세액적 분사에 따른 하이드레이트 형성 시간을 확인하였으며, 반응기 내부의 온도 변화를 확인하여 반응기 내부의 하이드레이트 형성 거동을 확인하고 이를 통하여 상용화를 위한 반응기 설계의 기초 자료로 활용하고자 하였다.

  • PDF