• 제목/요약/키워드: 이동형 음압기

검색결과 12건 처리시간 0.023초

이동형 음압기를 적용한 긴급 전환형 임시음압격리병실의 실내 환경 측정 분석 (Measurement and Analysis of Indoor Environment in Emergency Switching Type Temporary Negative Pressure Isolation Ward that Use Portable Negative Pressure Units)

  • 이원석;이세진;김희강;여명석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권4호
    • /
    • pp.89-97
    • /
    • 2022
  • Purpose: Because of the recent COVID-19 pandemic, there have been many cases of using portable negative pressure unit to convert general wards into temporary negative pressure isolation wards. The purpose of this study is to analyze the indoor environment of the switching type wards. Methods: Field measurements and experiments were conducted in a medical facility. Air volume, wind speed and pressure difference were measured in non-occupant state. Dispersion tests were performed with gas and particle matter. Results: The pressure difference between the wards and the corridor was higher than -2.5 Pa in normal situation. However, in the gas and particle dispersion tests, it was found that there were concerns about the spread through leakages in low-airtight walls or ceilings. In addition, it was confirmed that the pressure imbalance in ducts through the non-sealed diffusers could cause back flow during portable unit operation. Furthermore, when there was a pressure difference between adjacent wards planned to be at same pressure level, the possibility of the spread through the leakages was found. Implications: When using portable units for making switching type wards, it is necessary to create airtight space and seal the non-operation diffusers. In case of operating the air handling unit, T.A.B must be performed to adjust the duct balancing.

긴급전환형 임시음압격리병실의 기밀도에 따른 최소 급배기 유량차 평가 (Analysis of Minimum Airflow Differences between Supply and Exhaust Air according to Airtightness of Rapidly Converted Temporary Negative Pressure Isolation Rooms)

  • 신희원;김동욱;김지민;정효범;강동화
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권4호
    • /
    • pp.69-77
    • /
    • 2023
  • Purpose: During the COVID-19 pandemic, there have been many cases of converting regular hospital wards into temporary negative pressure isolation wards. The purpose of this study is to evaluate the minimum airflow differences that satisfies the pressure difference criteria(-2.5 Pa) according to airtightness of switching type wards, in preparation for utilization of aging regular wards as negative pressure isolation wards. Methods: Visual inspection and field measurements were conducted using blower door to evaluate airtightness of 5 hospital wards. CONTAM simulation was used to assess the airflow differences when pressure difference between the corridor and wards met the criteria at various levels of airtightness. Results: The ACH50 of evaluated wards ranged from 19.3 to 50.1 h-1 with an average of 37.0 h-1, indicating more than four times leakier than other building types. The minimum airflow differences increased as the airtightness of the wards decreased and the size of the wards increased. Implications: When operating rapidly converted negative pressure isolation wards, understanding airtightness is crucial for determining the minimum airflow differences to maintain the pressure differences. The analysis of this study suggests that improving the airtightness of aging rooms is essential and the minimum airflow differences should be suggested considering both the airtightness and size of rooms.

완전 이식형 전기기계식 인공심장 심실간 공간 압력 파형에 관한 연구 (A Study of Interventricular volume Pressure in a Totally Implantable Electromechanical Artificial heart)

  • 조영호;최원우;박성근;이동준;최재순;김희찬;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.222-226
    • /
    • 1995
  • 인공심장에서의 박출량제어는 전부하에 따른 심박출균형, 심실내 완전충만과 완전구출을 구현하는데 그 목적이 있다. 본 논문에서는 인공심장 내부의 심실간 공간 압력파형을 심박출량의 제어에 활용하였다. 이를 위해서는 심실간 공간의 압력파형을 심실 유입부와 유출부의 혈류량에 대한 정보, 이동작동기의 위치신호와 동기시켜 해석하는 것이 필요하다. 이러한 압력파형의 해석을 바탕으로, 심실간 공간의 음압 크기로 좌,우 심방압을 추정하고 작동기의 좌,우 수축기때 심실간 공간의 음압크기를 비슷하게 유지하도록 작동거리를 제어하면 좌우 심박출 균형을 이룰 수 있음을 확인하였다. 또한, 심실의 완전충만과 완전구출의 실현을 위한 심실 충만 정도를 추정할 수 있게 하는 인자를 제시하였다.

  • PDF

포스트 코로나 시대 신종 감염병 대비를 위한 기존 의료시설의 비상시 운영사례 조사 및 분석 (Investigations on the emergency operation status of existing medical facilities to prepare for emerging infectious diseases in the post-COVID-19 era)

  • 이세진;이원석;김은석;여명석
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권1호
    • /
    • pp.43-51
    • /
    • 2023
  • Purpose: To accommodate the increasing number of patients during the COVID-19 pandemic, numerous portable HEPA filter units (PHUs) were installed in the general wards of existing medical facilities(EMFs) to convert them into emergency conversion facilities (ECFs). The purpose of this study was to build a dataset in preparation for emerging infectious diseases in the post-COVID-19 era by analyzing the construction and operation of ECFs. Methods: Field investigations were conducted during ECF operation periods based on the analysis of heating, ventilation, and air conditioning (HAVC) system design documents for six ECFs across Korea. Interviews were conducted with facility managers during the field investigations. Results: When constructing an ECF within an EMF, the installation status and characteristics of the existing system should be considered. Field investigations and verifications of the operation of HAVC systems must be conducted beforehand for smooth ECF operations. If heating and cooling are required with indoor air circulation type equipment in an ECF zone, the implementation of a heating and cooling method that can satisfy the comfort requirements of the occupants while minimizing cross-contamination is essential. When using PHUs that do not meet the performance standards required by medical equipment, the noise level resulting from such equipment operation must be evaluated and improved. Implications: For EMFs, various guidelines that can be referred to for the construction and operation of ECFs must be developed to prepare for emerging infectious diseases in the future.

고전압 COS 퓨즈로부터 방사된 충격성 소음 저감용 반사형 소음기의 설계 (Reactive Silencer Design for Suppressing Impulse Noise from a High Voltage Cut Out Switch Fuse)

  • 송화영;김덕한;이종석;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.951-954
    • /
    • 2006
  • This Study introduces the design of a reactive type silencer for reducing impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level above 150dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study. the reactive type silencers have been utilized. The performance of noise reduction for them can be expressed by insertion loss. The reactive silencers have been tested for 23 different types with each different porosity, hole diameter and depth. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise. The one-stage, two-stage and three-stage reactive type silencers have been shown to have the insertion losses of about from 35dB (A) to 25dB(A).

  • PDF

LS1P 마이크로폰 핵심측정표준 국제비교 결과 (Results of Key Comparison on LS1P Microphones)

  • 서재갑;조문재;권휴상;서상준
    • 한국음향학회지
    • /
    • 제24권4호
    • /
    • pp.194-201
    • /
    • 2005
  • 국제적으로 음향$\cdot$초음파$\cdot$진동분야의 정밀계측 필요성이 점차 강조되고 있기 때문에 1998년도에 국제도량형위원회(CIPM; International Committee for Weights and Measures) 산하에 음향$\cdot$초음파$\cdot$진동 자문위원회 (CCAUV; Consultative Committee for Acoustics, Ultrasound and Vibration)가 신설되어 활동을 시작하였다. 그 첫 번째 사업의 하나가 1999년부터 시작된 음향분야의 1" 표준 마이크로폰에 대한 핵심측정표준 국제비교 (Key Comparison)이다. 1" 표준 마이크로폰 핵심측정표준 국제비교는 1999년 4월부터 2001년 4월까지 진행되었으며 한국표준과학연구원을 포함한 12개 국가표준기관이 참여하였다. 주관기관 (pilot lab.)은 영국의 National Physical Laboratory (NPL)이 맡았다. 이동용 표준기는 IEC 61094-1에 명시된 1" 표준 음압형 마이크로폰 (LS1P Microphone; Laboratory Standard 1" Pressure Type Microphone) 두 개이며 교정 주파수 범위는 63 Hz부터 8 kHz까지이다. 본 논문에서는 최종 보고서에 수록된 분석 결과를 요약하여 정리하였다.

이동형 심폐보조시스템의 개발 (Development of Portable Cardiopulmonary Support System)

  • 이혁수;민병구
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.94-99
    • /
    • 2007
  • 협심증과 급성 심근 경색증 등 관상동맥 질환이 급증함에 따라 병원 밖이나 응급실 중환자실 심도자 검사실 등에서 급성 심장 쇼크에 빠지거나 심장마비가 발생하는 경우가 많이 발생하고 있다. 이러한 심혈관 질환에는 정류성 체외생명보조장치가 널리 사용되고 있으나 이러한 장치는 그 무게와 크기로 인해 응급상황에 대처할 수 있는 능력이 작고, 막형 산화기의 전단에 인가되는 압력이 크며, 시스템 구성상 혈액이 공기에 노출된다. 박동성 혈류를 공급하기 위하여 단일 구동펌프를 이용한 시도가 있었으나 회로내의 순간 압력 상승 등으로 인한 여러 가지 단점들이 발생한다. 이러한 기존의 체외생명보조장치의 단점을 극복하고자 한국형 인공심장의 원리를 이용한 이중 박동식 혈액펌프를 개발하였다. 이 시스템의 구동원리는 막형산화기를 중심으로 전.후에 혈액펌프를 위치하여 혈액펌프를 Actuator가 한번씩 짜주는 것이다. 이런 방법으로 구동할 경우 막형산화기 후단에 있는 펌프가 음압을 동시에 일으킴으로, 막형산화기에 인가되는 큰 양압을 줄인다는 가정 하에 시스템을 개발한 것이다. 생체외 실험을 통하여 각 부분의 압력을 측정하고, 총 12건의 동물실험을 통하여 그 장점을 검증하였다

고전압 COS 퓨즈로부터 방사된 충격성 소음의 지속시간 제어에 관한 실험적 연구 (An Experimental Study on the Control of Duration time of Impulse Noise from a High Voltage COS Fuse)

  • 송화영;김덕한;이종석;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.258-261
    • /
    • 2006
  • This study introduces the control of duration time of impulse noises emitted from a high voltage COS fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the peak sound pressure level over 150 dB(A) is generated at the distance of 2m from a COS Fuse. For the purpose of the reduction of impulse noise, in this study, the reactive type silencer has been utilized. And also electrical interrupting test was experimented. From the experimental results, the reactive type silencer has been shown to have the noise reduction of about 13 dB(A). It has been found that the electrical interception performance of the COS fuse was related to the control of the duration time of impulse noise.

  • PDF

직선집속 PVDF 초음파트랜스듀서의 제작과 응용 I. 제작 및 특성평가 (Fabrication of PVDF Line Focus Ultrasonic Transducer and its Application I. Fabrication and Characteristics Evaluation)

  • 윤혁준;하강열;김무준
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.387-390
    • /
    • 1999
  • 누설탄성표면파(Leaky Surface Acoustic Wave : LSAW) 측정에 사용하는 것을 목적으로 PVBF 압전막을 이용하여 직선집속 초음파트랜스듀서를 제작하고 그 특성을 평가하였다. 제작은 한쪽 면이 원통형 구조를 갖는 구리, 알루미늄, 3mmPVC-에폭시 3가지 재료를 배면층으로 사용하여 각각에 PVDF를 부착시켜서 수중에 음파를 방사하도록 구성하였고, 특성평가는 임펄스응답 특성과 음장 특성으로 나누어서 평가하였다. 임펄스응답 특성은 제작한 3종류의 집속 초음파트랜스듀서에 대해 실험적으로 측정하고, Mason 등가회로1)를 이용한 이론적 해석결과와 비교하였다. 음장특성 측정실험은 구리를 배면체로 하여 제작한 집속 초음파트랜스듀서에 대해서 실시하였고, 그 이론적인 계산결과는 Raylelgh-Somme-rfeld 회 절이론2)을 도입하여 초점면에 형성되는 음압분포를 계산하는 것으로 얻어졌다. 실험은 펄스 초음파 송수기 및 $2{\mu}m/step$으로 이동하는 정밀 x-y-z 스테이지를 컴퓨터에 연결하여 자동 측정하는 것으로 수행되었는데, 그 결과는 이론 해석결과와 비교적 잘 일치하였다.

  • PDF