• Title/Summary/Keyword: 이광자 센서

Search Result 27, Processing Time 0.021 seconds

Detection of Intracellular Free Metal Ions with Molecular Two-Photon Sensors (이광자 분자센서를 이용한 생체 내 금속이온 검출)

  • Kim, Hwan-Myung
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.231-237
    • /
    • 2011
  • Two-photon microscopy (TPM) is attracting much attention in biological imaging due to the capability of imaging deep inside the living tissues for a long period of time. For maximum utilization of TPM, it is essential to develop efficient twophoton sensors. Regarding this, many research groups are developing two-photon sensors for specific applications. In this review, we summarize recent results on selected examples of two-photon sensors for intracellular free metal ions in the live cells and tissues to provide a guideline for various imaging applications.

A Study on Dip-Pen Nanolithograpby Process to Fabricate 2D Pbotonic Crystal for Planar-Type Optical Bio-Sensor (평판형 광-바이오센서 (Planar-Type Optical Bio-Sensor)용 2차원 광자결정 제작을 위한 Dip-Pen Nanolithography 공정 연구)

  • Kim, Jun-Hyong;Lee, Jong-Il;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.381-383
    • /
    • 2005
  • 바이오센서 응용을 위한 대칭 및 비대칭 마하젠더 간섭계 광도파로 소자의 설계, 제작 및 광학적 응답특성을 평가하였다. 설계 제작된 광도파로 소자의 압력광원은 각각 1550nm와 632.8nm이고, 코어와 클래딩의 굴절률차는 0.45 $\Delta$%로 설계 제작하였다. 센서부(상위 클래드)의 금 박막의 미소 굴절률 변화에 따른 TE, TM모드의 특성을 분석하였다. 센서의 보다 높은 감도 개선을 위한 나노-광자결정 구조가 주목받고 있는데, 광자결정 구조의 구현를 위한 리소그래피 공정은 높은 분해능과 신뢰성 있는 나노스케일의 공정이 요구된다. 광-바이오센서의 감도 개선을 위해 센서부 표면에 2차원 나노-광자결정 배열을 제안하고 이를 구현하기 위한 Dip-Pen Nanolithography 공정에 대해 고찰하였다.

  • PDF

Thermoluminescence and Photostimulated Luminescence of BaFBr:BaFBr:Eu2+ Phosphor (BaFBr:Eu2+ 형광체의 열발광 및 광자극발광 특성)

  • Doh, Sih-Hong;Seo, Hyo-Jin;Kang, Kab-Jung;Kim, Young-Kook;Kim, Do-Sung;Kim, Sung-Hwan;Kim, Chan-Jung;Lee, Byung-Hwa;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.301-308
    • /
    • 2002
  • BaFBr:$Eu^{2+}$ phosphors were prepared, and the thermoluminescence(TL) and photostimulated luminescence(PSL) of the prepared phosphors were measured. Two glow peaks around 352 and 448 K are observed for x-ray irradiated BaFBr:$Eu^{2+}$ phosphors, and the activation energy of the main glow peak(352 K) was about 0.96 eV. The spectral range of the PSL was $350{\sim}450\;nm$, and the activation energy of the trap giving rise to PSL was about 0.98 eV. The activation energy of the traps giving rise to TL is agreed to those giving rise to PSL within experimental error.

Technical Trends of Sensor Networking (센서 네트워킹 기술 동향)

  • Jeong, H.;Lee, J.O.;Lee, J.Y.;Park, N.S.;Jin, G.J.;Kim, B.S.
    • Electronics and Telecommunications Trends
    • /
    • v.22 no.3 s.105
    • /
    • pp.80-89
    • /
    • 2007
  • 인간과 사물, 컴퓨터간의 유기적인 관계 및 통신을 위하여 유비쿼터스 센서 네트워크기술은 다양한 분야에서 응용 및 기술 개발이 이루어지고 있다. 센서 네트워킹 기술은 유비쿼터스 센서 네트워크 시스템에서 가장 기본적인 구성 요소로 핵심 요소 기술에 대한 IPR 확보 및 지능화 기술 개발에 노력하고 있다. 이에 센서 네트워킹 기술의 특징과 기술에 대한 국내외 동향 및 전망에 대하여 살펴보고자 한다.

Polarization-Maintaining Photonic-Crystal-Fiber-based Polarimetric Strain Sensor with a Short Sensing Head (짧은 센서부를 가진 편광유지 광자결정 광섬유 기반 편광 간섭형 스트레인 센서)

  • Noh, Tae Kyu;Lee, Yong Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.3
    • /
    • pp.131-136
    • /
    • 2014
  • In this paper we have implemented a temperature-insensitive polarimetric fiber strain sensor based on a Sagnac birefringence interferometer composed of a short polarization-maintaining photonic crystal fiber (PM-PCF), a 3-dB fiber coupler, and polarization controllers. The PM-PCF used as a sensor head was 2 cm long, which is the shortest length for a sensing element compared to other polarimetric fiber strain sensors using a PM-PCF. The proposed sensor showed a strain sensitivity of ${\sim}0.87pm/{\mu}{\varepsilon}$ with a strain measurement range from 0 to $8m{\varepsilon}$. The temperature sensitivity was also investigated and measured as approximately $-12pm/^{\circ}C$, when ambient temperature changed from 30 to $100^{\circ}C$. This temperature sensitivity is about 82 times smaller than that of conventional polarization-maintaining fiber (approximately $-990pm/^{\circ}C$). In particular, from a practical perspective we have experimentally and theoretically confirmed that the wavelength selected for the indicator dip location does not make a significant difference in the strain sensitivity.

Current Activities in optical Industrial Technlogy Development (광응용 산업기술의 개발현황)

  • 강인구
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.07a
    • /
    • pp.1-4
    • /
    • 1991
  • 근래 금성중앙연구소에서 수행하소 있는 광관련 산업기술 개발 현황의 소재를 통해 한국기업의 기술수준을 짐작할수 있을 것이다. 본 연구소의 광관련 기술 개발은 화합물 반도체를 이용한 광소자, 박막기술을 이용한 액정 및 이미지 센서, 광자기 디스크 그리고 호로그래피 관련분야로 구별될수 있고, 이에 해당하는 과제의 성과를 소개하고자 한다.

  • PDF

Photostimulated Luminescence and Photoluminescence of SrCl2:Eu2+ Phosphors (SrCl2:Eu2+ 형광체의 광발광 및 광자극발광 특성)

  • Doh, Sih-Hong;Seo, Hyo-Jin;Kim, Young-Kook;Kim, Do-Sung;Kim, Sung-Hwan;Kim, Chan-Jung;Lee, Byung-Hwa;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.319-326
    • /
    • 2002
  • $SrCl_2:Eu^{2+}$ phosphors were prepared by the solid phase reaction method, and their photostimulated luminescence(PSL) and photoluminescence(PL) characteristics were investigated. The PSL and PL peak of the $SrCl_2:Eu^{2+}$ phosphors are due to the $5d{\rightarrow}4f$ transition of $Eu^{2+}$ ions in phosphors. The PSL and PL spectrum obtained by the 355nm excitation was observed in $380{\sim}440\;nm$ region with the peak at 407 nm. The dose response of the PSL phosphors were linear within $2.5\;mGy{\sim}200\;mGy$ of 100 kV X-ray. The fading of the phosphors at room temperature was approximately 60% after 20 min.

Photonic Crystals Based on Colloid Self-Assembly (콜로이드 자기 조립체를 이용한 광결정)

  • 박정호;구혜영;김동유
    • Polymer Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.274-285
    • /
    • 2004
  • 콜로이드 결정 (Colloid crystal)이란 용액 상에서 부유 하는 작은 입자들의 자기 조립 (self-assembly)에 의해 형성된 주기적인 2차원 혹은 3차원 구조를 말한다. 이러한 결정 구조는 광학 필터나 스위치, 광 밴드 갭 재료, 바이오 센서 등의 과학 기술적인 응용을 비롯하여 액화 물질의 상 변화 등과 같은 물리적 현상을 규명함에 있어서 중요한 모델을 제시한다. 특히 최근에 콜로이드의 자기 조립체는 자연적으로 갖게 되는 주기적인 유전율 변화 때문에 빛의 진행 방향이나 특성을 조절할 수 있는 광자 결정 (Photonic Crystal) 구조 제작의 경쟁력 있는 접근 방법으로 각광 받고 있다. (중략)

  • PDF

Design and Deposition of Optica Thin Films (광학 박막의 설계 및 증착)

  • 황보창권
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.152-152
    • /
    • 2000
  • Abeles가 특성 행렬을 이용하여 기본 이론을 확립한 이래, 광학 박막의 설계는 개인용 컴퓨터의 출현으로 다양한 방법으로 쉽게 할 수 있으며, 그 응용이 빠르게 증가하고 있다. 또한 이온빔을 이용한 증착 기술의 발전으로 덩어리에 가까운 박막을 증착하고 있으며 박막의 광학적, 기계적 특성을 향상시키고 있다. 최근에는 초고속 다용량 광정보통신, 디스플레이, 레이저, 광센서, 광자기술, 광전자 등의 발전에 따라 고품질의 박막을 제작하기 위한 기술이 발전하고 있으며, 이에 따라 합성 설계 방법과 물질의 기본적 특성을 분석하기 위한 방법도 다양하게 발전되고 있다. (중략)

  • PDF

Digital Imaging Source Identification Using Sensor Pattern Noises (센서 패턴 잡음을 이용한 디지털 영상 획득 장치 판별)

  • Oh, Tae-Woo;Hyun, Dai-Kyung;Kim, Ki-Bom;Lee, Hae-Yeoun
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.12
    • /
    • pp.561-570
    • /
    • 2015
  • With the advance of IT technology, contents from digital multimedia devices and softwares are widely used and distributed. However, novice uses them for illegal purpose and hence there are needs for protecting contents and blocking illegal usage through multimedia forensics. In this paper, we present a forensic technique for identifying digital imaging source using sensor pattern noise. First, the way to acquire the sensor pattern noise which comes from the imperfection of photon detector against light is presented. Then, the way to identify the similarity of digital imaging sources is explained after estimating the sensor pattern noises from the reference images and the unknown image. For the performance analysis of the proposed technique, 10 devices including DSLR camera, compact camera, smartphone and camcorder are tested and quantitatively analyzed. Based on the results, the proposed technique can achieve the 99.6% identification accuracy.