• Title/Summary/Keyword: 의료정보표준

Search Result 323, Processing Time 0.02 seconds

The Medium Access Scheduling Scheme for Efficient Data Transmission in Wireless Body Area Network (WBAN 환경에서 효율적 데이터 전송을 위한 매체 접근 스케줄링 기법)

  • Jang, EunMee;Park, TaeShin;Kim, JinHyuk;Choi, SangBan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.2
    • /
    • pp.16-27
    • /
    • 2017
  • IEEE 802.15.6 standard, a Wireless Body Area Network, aims to transfer not only medical data but also non-medical data, such as physical activity, streaming, multimedia game, living information, and entertainment. Services which transfer those data have very various data rates, intervals and frequencies of continuous access to a medium. Therefore, an efficient anti-collision operations and medium assigning operation have to be carried out when multiple nodes with different data rates are accessing shared medium. IEEE 802.15.6 standard for CSMA/CA medium access control method distributes access to the shared medium, transmits a control packet to avoid collision and checks status of the channel. This method is energy inefficient and causes overhead. These disadvantages conflict with the low power, low cost calculation requirement of wireless body area network, shall minimize such overhead for efficient wireless body area network operations. Therefore, in this paper, we propose a medium access scheduling scheme, which adjusts the time interval for accessing to the shared transmission medium according to the amount of data for generating respective sensor node, and a priority control algorithm, which temporarily adjusts the priority of the sensor node that causes transmission concession due to the data priority until next successful transmission to ensure fairness.

An Image-Based Annotation for DICOM Standard Image (DICOM 표준 영샹을 위한 이미지 기반의 주석)

  • Jang Seok-Hwan;Kim Whoi-Yul
    • Journal of Korea Multimedia Society
    • /
    • v.7 no.9
    • /
    • pp.1321-1328
    • /
    • 2004
  • In this article, we present a new DICOM object able to create image-based annotations in DICOM image. Since the proposed image-based annotation uses images themselves of annotation, various types like character, sketch, and scanning image, etc., can be imported into annotation easily. The proposed annotation is inserted into DICOM image directly but they do not influence original DICOM image quality by using independent data channel. The proposed annotation is expected to be very useful to medium and small clinics that cannot afford picture archiving and communication systems or electronic medical record.

  • PDF

Analyzing Training Program for Hospital Coordinators (병원코디네이터 교육프로그램 분석연구)

  • Yang, Hye-Jung;Suh, Won S.
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.530-539
    • /
    • 2013
  • It is needed to provide a supplicated and standardized training program for hospital coordinators to boost their competencies as professionals. The purpose of this study was to propose a standardized training program for hospital coordinators especially trained at private institutions. Using DACUM method, with 11 professionals, we first developed competencies required for hospital coordinators. They were service mind, attitude, MOT(Moment of Truth) & phone-call etiquette, communication skill, customer behavior, basic medical terminology, insurance, computer skills, etc. Finally, we proposed a standardized training program for hospital coordinators which covers 16 subject areas.

Standardization of the Dental Chart for Comtuterization of The Medical Information (의료정보 전산화를 위한 치과차트의 표준안 제시)

  • Kim, K.T.;Ahn, S.H.;Kim, M.S.;Chun, M.C.;Kim, S.S.;Jun, K.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.253-254
    • /
    • 1998
  • The standardization of the dental chart proposed to computerization of the dental hospital information. To objective standardization, we gathered the dental chart from four university hospital(seoul, yonsei, kyunghee, pusan) and held a conference with dental physicians. From gathered charts, we classified the common and non-common items. We proposed the standardization to choose the most of the common items and necessary non-common things. The proposed chart include those items and the new things which the dental physicians want. After this paper, we will hold a conference with more dental physicians about more data to make more useful proposal.

  • PDF

Design of PC-based CR-PACS using Multiresolution Wavelet Transform (다해상도 웨이블릿 변환을 이용한 PC기반의 CR-PACS 설계)

  • 김광민;유선국
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.305-312
    • /
    • 1998
  • A small PACS based on PC is designed for CR. To receive the digital image from CR, a DICOM Interface Unit (DIU) is designed that complied with the medical image standard, DICOM V3.0. The CR images acquired through the DIU are stored in a file-server; the patient information of the images is stored in a database. To improve the performance of PC and to use it easily, multiresolution images are constructed by wavelet transform and displayed progressively. Wavelet compression method is newly adopted to store the images hierarchically to storage units. In this compression method, the image is decomposed into subclasses of image by wavelet transform, and then the subclasses of the image are vector quantized using a multiresolution codebook. The storage units for CR images were divided into the short-term storage in file-server and the harddisk in viewing station. Image processing tools supported by general PACS is implemented based on PC.

  • PDF

Development of m-Health Application based on Medical Informatics Standards (의료정보 표준에 기반 한 m-Health 어플리케이션 개발)

  • Park, Hyun Sang;Kim, Hwa Sun;Jung, Hyun Jung;Cho, Hune
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.5
    • /
    • pp.640-653
    • /
    • 2014
  • Recently medical consumers pursue high leveled quality of life through active promotion, prevention, management activity of health as the importance of health during home life is emerged to meet the aging society and chronic diseases. In addition, people are directed to the m-Health for managing yourself their health by using smartphone and various personal health devices, if necessary transmits health data to the physician himself. In the previous studies, m-Health Application were developed and applied in the real clinical environment by adopting the medical information standards was rarely conducted. Therefore, in this study, the m-Health application platform was developed. Developed application was communicate with IEEE 11073 standard protocol using the Bluetooth Health Device Profile in personal health device via smart phone to process blood pressure information, and it converted to HL7 V2.6 ORU_R01 message for send to remote medical server. In addition, we tested the interoperability and safety of the developed application for 23 inpatient and 17 outpatient at D University Hospital. As a result, the blood pressure information has been transmitted without error.

Overview and Prospects of Patient Centered-Smart Hospitals (환자중심 스마트병원의 개요와 전망)

  • Park, Hyunyoung;Cho, Yong Jin
    • Journal of Digital Convergence
    • /
    • v.19 no.7
    • /
    • pp.419-426
    • /
    • 2021
  • With the development of the information and communication technology, the smart hospital has become a new trend in a healthcare industry. This study reviewed the concept, key technologies, applications, and future challenges of a smart hospital, and the user-centered strategies for designing a smart hospital. In smart hospitals, digitally enabled clinical staff will be able to produce better patient outcomes by delivering a more integrated patient-centered care with an efficient manner in connected facilities systems. However, to promote a successful patient-centered smart hospital environment in the future, various obstacles regarding cost, technology, security, and standards should be overcome. It is also necessary for patients and medical personnel to be involved as service users.

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.

Device Adapter Model based on Dynamic Management Module for u-Health gateway (u-헬스 게이트웨이를 위한 동적 관리 모듈 기반의 디바이스 어댑터 모델)

  • Kim, Jong-Tak;Song, Si-Yun;Hwang, Hee-Jeong
    • Journal of Internet Computing and Services
    • /
    • v.11 no.2
    • /
    • pp.41-48
    • /
    • 2010
  • It is essential to guarantee a smooth communication and data exchange in a PHD(Personal Healthcare Device) network for applications providing U-health services. In spite of that, most of PHDs are heterogeneous, so the heterogeneity of their protocols makes it difficult to develop an integrated gateway sending sensed healthcare data to U-health service providers. To solve this problem, we suggest the design and implementation of a device adapter model based on dynamic managed module in this paper. Our model were implemented to work on the OSGi-based gateway middleware and to have interoperability in connection with the HL7 system that is the standard of the Healthcare Information systems. In addition, our model has an architecture supporting a communication based on the object serialization in order to provide extensibility in the functional aspect of applications. Through the experiment on a test-bed which is an implementation of the device adapter module for electrocardiogram and blood-pressure/blood-sugar device having one channel, we have confirmed the accuracy of sensing and sending data.

An adaptive load balancing method for RFID middlewares based on the Standard Architecture (RFID 미들웨어 표준 아키텍처에 기반한 적응적 부하 분산 방법)

  • Park, Jae-Geol;Chae, Heung-Seok
    • The KIPS Transactions:PartD
    • /
    • v.15D no.1
    • /
    • pp.73-86
    • /
    • 2008
  • Because of its capability of automatic identification of objects, RFID(Radio Frequency Identification) technologies have extended their application areas to logistics, healthcare, and food management system. Load balancing is a basic technique for improving scalability of systems by moving loads of overloaded middlewares to under loaded ones. Adaptive load balancing has been known to be effective for distributed systems of a large load variance under unpredictable situations. There are needs for applying load balancing to RFID middlewares because they must efficiently treat vast numbers of RFID tags which are collected from multiple RFID readers. Because there can be a large amount of variance in loads of RFID middlewares which are difficult to predict, it is desirable to consider adaptive load balancing approach for RFID middlewares, which can dynamically choose a proper load balancing strategy depending on the current load. This paper proposes an adaptive load balancing approach for RFID middlewares and presents its design and implementation. First we decide a performance model by a experiment with a real RFID middleware. Then, a set of proper load balancing strategies for high/medium/low system loads is determined from a simulation of various load balancing strategies based on the performance model.