Demand for the Radiological Technologist Independent Act for the Performance of the Duties of a Radiological Technologist (방사선사 직무수행을 위한 방사선사 단독법 제정에 대한 요구도)

  • Kim, Eun-Hye;Lim, Cheong-Hwan;Lim, Woo-Taek;Joo, Young-Cheol;Hong, Dong-Hee;Jung, Hong-Ryang;Moon, Young-Ju;Kim, Hoon;Jung, Young-Jin;Choi, Ji-Won;Yoon, Yong-Su;Cho, Pyong-Kon;Park, Myeong-Hwan;Yang, Oh-Nam;Jeong, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.525-534
    • /
    • 2021
  • In order to provide high-quality medical services to the public and contribute to the improvement of public health, it is necessary to enact an independent law according to the work of radiological technologists. Therefore, this study intends to review the regulations related to radiographers in the Medical Service Technologists, etc. Act. and to present opinions and directions for enactment of individual laws for radiological technologists. An online survey was conducted to 15,000 radiological technologists working in medical institutions and education sites in Korea; 1,027 people (6.85%) responded. The questionnaire consisted of 3 questions on demographic characteristics, 5 questions on the scope of work, and 12 questions on the revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological Technologist Independent Act. Reliability and factor analysis were performed on 9 questions measured on a Likert 5-point scale in "Revision of the Medical Service Technologists, etc. Act. and the establishment of the Radiological echnologist Independent Act" among the questionnaire items. Reliability for the total 9 questions was Chronbach α=0.728. There was a high perception that the regulations related to radiological technologists were insufficient in the current Medical Service Technologists, etc. Act., and the perception that examinations performed by radiological technologists at medical institutions were included in medical practice was high. If the Radiological Technologist Independent Act is enforced, a high percentage of respondents said that they could receive legal protection through the institutionalization of the scope of work, that the status of radiological technologists would be improved, and the scope of work would be expanded. The response that the scope of work of radiological technologists should be included was the highest at 96.6%. In the analysis according to demographic characteristics, it was found that 96.7% of the respondents were agreed regardless of the factors. Radiological technologists will have to work hard to secure the public health by coping with new radiology devices, procedures and treatment methods. Therefore, as the results of this study, it is expected that the enactment and implementation of the Radiological Technologist Independent Act will contribute to the improvement of the quality of treatment for patients and to the public health.

A Study on the Usefulness of an Ankle Joint Examination Assistive Device using a 3D Printing (3D 프린터를 이용한 발목관절 검사 보조기구의 유용성연구)

  • Dong-Hee Hong;Eun-hye Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1099-1108
    • /
    • 2023
  • The mortise view radiography procedure is an ankle joint examination and observes the presence of trauma, sprain, or dislocation suspected in the ankle joint. The auxiliary equipment used during the mortise view radiography procedure can generate artifacts in the radiograph images and is not diverse enough to be custom-made for each patient; not cost-efficient. The purpose of this study is to create a custom assistive device to support mortise view radiography procedure. This study utilized 3D printing technology to create the mortise view radiography procedure assistive device (ShinHan Device; SHD). The lengths of the tibiotalar joint (TTJ), talar calcaneal joint (TCJ), and medial joint (MJ) were measured and evaluated by five researchers using both SHD and the prototype Hologic tool. The mean ranges were found to be 39.42-39.47 mm for TTJ, 31.41-31.57 mm for TCJ, and 21.21-21.23 mm for MJ while using SHD device. On the other hand, the measurements showed mean ranges of 39.73-39.79 mm for TTJ, 31.46-31.50 mm for TCJ, and 21.31-21.35 mm for MJ while using the Hologic tool. Based on this study results, the error ranges at all positions decreased by 24% for TTJ, 17% for TCJ, and 36% for MJ when using SHD device compared to the Hologic tool. Moreover, when SHD was used, it allowed for a highly reproducible examination posture (ICC = 0.99), and it enabled the acquisition of radiograph images without artifacts, which were present in the Hologic tool.

The implementation of remote IPMC control system using android smartphone (안드로이드 스마트폰 기반의 원격 IPMC 제어시스템 구현)

  • Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.3
    • /
    • pp.533-539
    • /
    • 2013
  • Recently, Ionic Polymer Metal Composite (IPMC) systems receive great attention in the fields of the medical and biomedical Engineering because of several merits in terms of new actuators and sensors and fuel cell materials. When the voltage is excited to IPMC system, it moves. Conversely, if there are any movement on the IPMC, the IPMC has charge voltage by the internal properties. Therefore the IPMC can be used as a motion sensor or force sensor. In this paper, we identify characteristics of the IPMC and control its movements from remote locations by the smart-phone system based on visual information for monitoring. Additionally, control of movements of the IPMC is realized by transmit motion commands using the smart-phone system with the blue-tooth communication. Unfortunately, there are some deficiencies to perfectly attain physical properties of the IPMC systems from our experiments in this paper. However, in its utilization point of view, we demonstrate that the IPMC has some potentials as new sensors, actuators, and fuel cells.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

The Effect of Family-Centered Coaching Based on Sensory Integration on the Performance of Children with Autism Spectrum Disorder (감각통합 기반의 가족중심코칭이 자폐스펙트럼장애 아동의 작업수행에 미치는 효과)

  • Kim, Yoon-Sung;Kim, Kyeong-Mi;Chang, Moon-Young;Hong, So Young
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.19 no.2
    • /
    • pp.12-25
    • /
    • 2021
  • Objective : This study explored the effects of family-centered coaching using a sensory integration-based approach on the levels of performance and satisfaction for children with autism spectrum disorder (ASD). Methods : From April 16, 2020 to August 6, 2020, participants included 10 children with ASD, between the ages of three to six who met the inclusion criteria, and their guardians. I used the Canadian Occupational Performance Measure (COPM) to evaluate the children's levels of performance and satisfaction and the Goal Attainment Scaling (GAS) to evaluate their occupational performance. The experimental group (n=5) continued the sensory integration therapy while receiving their personalized family-centered coaching training for 60 minutes per week. This continued for four weeks via home visits and video calls. The control group (n=5) also continued to receive the sensory integration therapy while receiving sensory integration-based general counseling in relation to activity objectives. Results : Statistically significant differences were found in the scores of COPM performance and satisfaction and the GAS scores between the experimental group and the control group, before and after the intervention (p<.05). Statistically significant differences were found in score changes in COPM and GAS, between the two groups (p<.05). Cohen's d also showed a big effect size on the scores of COPM satisfaction (d=2.768) and the GAS scores (d=2.786). Conclusion : This study demonstrated that the sensory integration-based, family-centered coaching had more positive effects on the level of performance and satisfaction of children with ASD, than general counseling.

The Study on Filling Factor of Radiation Shielding Lead-free Sheet Via Screen Printing Method (스크린 프린팅 공법을 통한 방사선 무연 차폐 시트에 관한 연구)

  • Kang, Sang-Sik;Jeong, Ah-Rim;Lee, Su-Min;Yang, Seung-Woo;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.713-718
    • /
    • 2018
  • In many previous studies, monte carlo simulation is used to produce lead-free shielding sheet, and the possibility of radiation shielding capability and weight reduction is presented. But it is difficult to simulation for binder and micro-pores because of In fact it does not provide sufficient information necessary for the commercialization process. Therefore, in this paper, the results of radiation shielding capability corresponding to filling factor was presented by using the screen printing method to provide information on gel-paste required for the commercialization process. In this study, the geometric setup for evaluate of radiation shielding ability was designed to comply with IEC 61331-1:2014 and KS A 4025. In addition, radiation irradiation conditions were 100 kVp filtered with 2.0 mmAl total filtration was applied according to KS A 4021 standard. In this study, Pb $1270{\mu}m$, $BaSO_4$ $3035{\mu}m$, $Bi_2O_3$ $1849{\mu}m$ and $WO_3$ $2631{\mu}m$ were analyzed based on ten value layer. Additionally, the filling factor was analyzed as $BaSO_4$ 38.6%, $Bi_2O_3$ 27.1%, $WO_3$ 30.15%. However, in the case of applying low-temperature high-pressure molding in the future, it is expected that the radiation shielding capability can be sufficiently improved by reducing the porosity while increasing the filling factor.

The Effects of the Extracorporeal Shock Wave Therapy on Complex Pain Scales of Neck-Shoulder in 20s Adults with VDT Syndrome due to prolonged Smartphone Use (장시간 스마트폰 사용으로 VDT증후군을 가진 20대 성인의 체외충격파적용이 목-어깨의 복합적 통증지수에 대한 효과)

  • Seo, Kyo-Chul;Park, Seung-Hwan;Cho, Mi-Suk
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.135-142
    • /
    • 2021
  • The purpose of this study was to determine the effect of extracorporeal shock wave therapy for the neck-shouler muscles of complex pain scales of the 20s adults with VDT Syndrome to prolonged smartphone use. Twenty subjects with neck pain due to VDT syndrome participated in the experiment. They were randomly divided into 10 experimental groups and 10 control groups. Experimental subjects were conducted for 4 weeks, 5 days a week. The experimental group was subjected to extracorporeal shock wave therapy 2000 times at an intensity of 5 Hz and 2.0 bar once, and the control group performed self-stretching exercise for 30 minutes once. Subjects measured and compared neck-shoulder pain with VAS and PPT before and after the experiment. Data analysis was performed with SPSS win 18.0, and correspondence comparison was performed to analyze the results of the experimental group and the control group before and after the experiment. After the experiment, the experimental group decreased more in VAS and PPT of the neck-shoulder muscle. but the control group was no difference. Though these results, extracorporeal shock wave therapy was showed a reduction in pain after treatment than before treatment but there are no difference in the pain reduction after self-stretching exercise. Thus, extracorporeal shock wave therapy is expected to be used as a variety of treatments to reduce neck-shoulder pain as a cause of VDT syndrome.

Evaluation of Usefulness of CT Angiography in the Lower Extremity using Heart Rate (심박동 수를 활용한 Lower Extremity CT Angiography 검사의 유용성 평가)

  • Sung-Sik, Kim;Ho-Sung, Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.53-62
    • /
    • 2023
  • The purpose of this study is to find an optimized imaging technique and evaluate its usefulness by comparing and analyzing the difference in contrast enhancement of lower extremity artery according to the patient's heart rate during lower extremity Computed Tomography Angiography examination. From January 2022 to August 22nd, 139 outpatients who visited Ajou University Hospital and underwent lower extremity angio CT examination were targeted. According to the heart rate, the groups were divided into four groups: A(HR ≤65), B(65 < HR < 80), C(80≤ HR). In addition, among patients with a heart rate of 65 or less, the heart rate was considered, and the scan was divided into D, E, F group with a delay time. The time of arrival of contrast medium and the average value of contrast enhancement were compared and analyzed. As a result of quantitative evaluation, B and C groups with a heart rate of more than 65 times had better HU values in the popliteal artery than A group (HR ≤ 65), and D group showed better HU improvement effects compared to A group (p<0.001). The comparative analysis with other groups was insignificant. The difference in heart rate affected the angiographic intensity of the lower extremities artery. Therefore, it is effective to apply the appropriate test timing for each patient by using the heart rate during the lower extremity angio CT Scan.

The Study on Applicability of Semi-conductive Compound for Radioactive Source Tracing Dosimeter in NDT Field (비파괴 검사 분야의 방사성 동위원소 위치추적을 위한 반도체 화합물의 적용 가능성 연구)

  • Shin, Yohan;Han, Moojae;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.39-44
    • /
    • 2019
  • Radiation safety management is being considered very important since radioactive isotopes such as Co-60 and Ir-192 are widely used in fields such as non-destructive test(NDT). In this study, the applicability of Mercury(II) Iodide($HgI_2$) source for tracing system was evaluated. To make sure the unit cell sensor's reliability, we evaluated the electrical properties of the sensor made with $HgI_2$, and then position dependence of the sensor was analyzed and compared with the dose distribution from the planning system. As a result of the evaluation, high reliability of the sensor was shown through the linearity of R-sq > 0.990 and reproducibility of CV < 0.015. In the position dependence evaluation, the maximum value was measured at the isocenter of the sensor and gradually decreased according to the distance. However, the dose distribution data from the planning system was turned out that has difference with that of the sensor up to 30%. This seems to come from the difference between single-point measuring based planning system and area measuring based sensor.

Proposed Application Design for Community-Based Rehabilitation Services Access in Community Care System: Occupation and Activity Based (커뮤니티케어 제도 내 지역사회중심재활 서비스 접근을 위한 애플리케이션 디자인의 제안 : 작업과 활동 중심으로)

  • Bae, Seong-Hwan;Jang, Yeon-Sig;Baek, Ji-Young
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.4
    • /
    • pp.325-335
    • /
    • 2021
  • Chronic diseases have been increasing recently as the average life expectancy of humans has been extended, and this trend has caused problems such as the widespread demand for health and rehabilitation services and rising medical costs. In order to solve this problem, the community-based rehabilitation has been developed and strengthened in Korea and gradually promoted since 2019. It is important to secure access to clients who want to use services to revitalize community-based rehabilitation. So in this study, as part of the community-based rehabilitation, intends to devise smartphone applications designs and develop a prototype to secure access to community-based occupational therapy services based on occupation and activities. For Occupational Therapy Practice Framework (OTPF), International Classification of Functioning, Disability and Health (ICF), and Allen Diagnostic Module-2 (ADM-2) were used to devise and categorize occupation and activity based application content, and link OTPF, ICF, and ADM-2 through prior research analysis and expert meetings. The derived content was visualized through literature review and activity analysis, and was implemented to enable direct playback within the application using the YouTube API, and finally developed a prototype application. The Android Studio 3.5.2 for Windows 64-bit was used to build the application prototype. In further research, converging various digital technologies for user convenience and additionally researching community-based occupational therapy service providers opinions and service user satisfaction will improve accessibility to community-based occupational therapy services for clients who have difficulty occupational performance in the community.