• Title/Summary/Keyword: 의료영상분석

Search Result 520, Processing Time 0.024 seconds

On-line Quality Assurance of Linear Accelerator with Electronic Portal Imaging System (전자포탈영상장치(EPID)를 이용한 선형가속기의 기하학적 QC/QA System)

  • Lee, Seok;Jang, Hye-Sook;Choi, Eun-Kyung;Kwon, Soo-Il;Lee, Byung-Yong
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.127-136
    • /
    • 1998
  • On-line geometrical quality assurance system has been developed using electronic portal imaging system(OQuE). EPID system is networked into Pentium PC in order to transmit the acquisited images to analysis PC. Geometrical QA parameters, including light-radiation field congruence, collimator rotation axis, and gantry rotation axis can be easily analyzed with the help of graphic user interface(GUI) software. Equipped with the EPID (Portal Vision, Varian, USA), geometrical quality assurance of a linear accelerator (CL/2100/CD, Varian, USA), which is networked into OQuE, was performed to evaluate this system. Light-radiation field congruence tests by center of gravity analysis shows 0.2~0.3mm differences for various field sizes. Collimator (or Gantry) rotation axis for various angles could be obtained by superposing 4 shots of angles. The radius of collimator rotation axis is measured to 0.2mm for upper jaw collimator, and 0.1mm for lower jaw. Acquisited images for various gantry angles were rotated according to the gantry angle and actual center of image point obtained from collimator axis test. The rotated images are superpositioned and analyzed as the same method as collimator rotation axis. The radius of gantry rotation axis is calculated 0.3mm for anterior/posterior direction (gantry 0$^{\circ}$ and 170$^{\circ}$) and 0.7mm for right/left direction(gantry 90$^{\circ}$ and 260$^{\circ}$). Image acquisition for data analysis is faster than conventional method and the results turn out to be excellent for the development goal and accurate within a milimeter range. The OQuE system is proven to be a good tool for the geometrical quality assurance of linear accelerator using EPID.

  • PDF

Error Analysis of General X-ray Examination by Using Simulation Training (시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.919-927
    • /
    • 2018
  • The purpose of this study was to present simulation training model for general X-ray examinations and to analyze the errors that occur during the simulation training. From 2012 to 2018, a total of 183 students (77 men and 106 women) participated. The simulated X-ray system used computed radiography (CR) system. The contents of simulation training were patient's care, X-ray examinations accuracy, images stability, etc. As a result, it were found that the patient's position setting error, the accuracy error of the X-ray beam central ray, the image receptor's size and setting error, the error of the grid use, the marking error, and the error of X-ray exposure technical factors. It is expected that improved practical general X-ray examinations training of radiographer will be needed, focusing on these errors, so that we could contribute to the health care of the people by providing precise examinations and high quality medical service.

구내 방사선 촬영에 있어서 Film과 Digital sensor에 따른 피폭선량의 차이에 대한 비교

  • Kim, Ju-Yeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.45-49
    • /
    • 2005
  • 목적 : 기존 구내 방사선 촬영에서 사용되었던 Film에서의 노출선량과 Digital Sensor를 이용한 구내 디지털 촬영에서의 노출선량을 비교하여 현재 광범위 하게 사용 되어지고 있는 Digital Sensor가 환자의 피폭선량을 감소하는데 기여하는 정도를 알아본다. 대상 및 방법 : 치아 우식증이 없는 5개의 구치부 치아를 선택하여 석고 블럭에 매식한 후 교합면과 인접면에 우식병소들을 형성하였다. 이를 필름(Kodak Insight; IS, Kodak Co, USA)과 Digital Sensor(Kodak RVG 6000; Kodak Co, USA)에 XCP Instrument(Rinn Co, USA)를 사용하고, 전면에는 조직등가물질인 Acrylic Resin Block 20mm를 설치하였다. Acrylic Resin Block의 관구 측면 에서는 조사선량계를 부착하여 단계별로 변화시키는 노출조건에 대한 조사선량을 측정하였다. 그리고 이렇게 얻어진 영상을 3명의 방사선학 전공의와 1명 의 보존과 전공의가 평가를 하였다. 결과 : Film과 Digital Sensor를 가지고 촬영한 영상을 분석한 결과 노출선량에서도 Digital Sensor는 Film 노출선량과 비슷한 결과를 도출해 낼 수 있었다. 그러나 Digital Sensor로 촬영된 영상의 경우에는 Film 경우보다 좀더 효과적으로 조사선량을 판단 할 수 있었으며, 또한 영상 판독시 필름보다 폭 넓게 응용 할 수 있었다. 결론 : 본 연구에서는 선량 변화에만 의존하는 것이 아니라 Digital Sensor로 촬영시 영상 조절을 병행한다면 좀더 정확하고 효과적인 진단 활동에 도움이 될 수 있을 것으로 사료된다.

  • PDF

Segmentation and Visualization of Head MR Image Based on Structural Approach (구조적인 기법을 이용한 머리 MR 단층 영상의 조직 분류 및 가시화)

  • 권오봉;김민기
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.283-290
    • /
    • 1999
  • Because MR(Magnetic Resonance) slice images have much information of functions about body organs, it is very effeclive for diagnoses lo analyze and visualize MR slice images. A visuahzation process is composed of medical image acquisition, preprocessmg, segmentation, inlerpolation, rendering. Segmentation and interpolation among thenl ,1re currenl hot topics because of MR slice image imperfections. This paper proposes a method for segmentalion, mlerpolation respectively and addresses 3 D-visualizmg of a head. We segmented head tissues uomg otructural knowledge of head studied by clinical experiments sequentially. We improved the dynamic elastic inlerpolation to Utilize in concave conlour. We compared the proposed segmentation method and the interpolation method with other methods.

  • PDF

A Study on the Analysis of Area for the Planning of Diagnostic Imaging Department (영상의학부 공간계획을 위한 면적분석에 관한 연구)

  • Youn, Woo-Young;Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.12 no.1
    • /
    • pp.61-69
    • /
    • 2006
  • The Diagnostic Imagining Department essentially needs to be transformed by the plan of the room and the medical equipment which should be improved according to a rapid development in technology. And the room should be considered the scale and composition an the time of planning. Because this part is often influenced in a specific character of imaging equipment in the room. The researches on the scale and composition of Diagnostic Imaging Department were the main part in 1980's but after 1990's this kind of researches have not been enough. So this study has an intention of proposing basic data which is used in planning the Diagnostic Imaging Department by analyzing the actual condition of the area organization in general hospital.

  • PDF

A Parametric Imaging Technique for Characterizing Focal Liver Lesions in Contrast-Enhanced Ultrasound (간 병변 분석을 위한 조영증강 초음파 데이터의 영상화기법)

  • Park, So-Jeong;Sung, Myung-Chul;Lee, Seung-Kang;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.369-372
    • /
    • 2012
  • 조영증강 의료 초음파 영상에서 조영제의 확산효과에 대한 분석은 간질환과 연관된 각종 병변을 검출하고 분석하는 과정에서 매우 유용한 정보를 제공한다. 본 연구에서는 초음파 영상에서 조영제의 확산 패턴을 분석하고 이를 영상화하는 방법을 제안한다. 이 과정에서 부수적으로 호흡에 의한 흔들림 현상을 보정하고 노이즈의 영향을 극복할 수 있는 방법론을 고찰한다. 호흡주기에 따른 모멘텀 요소를 고려한 ROI 추적 기법은 측정과정에서의 흔들림과 노이즈에 의한 오류를 최소화 할 수 있게 한다. 조영제의 확산 단계에 따라 서로 다른 노이즈 비율을 고려하여 동적 가중치를 할당하는 방법으로써 흔들림을 보정하였으며, 조영제의 전이 시간과 패턴을 분석하고 그 특성을 분류함으로써 간 병변 분석을 위한 효과적인 영상화기법을 구현하였다. 또한 생성된 영상에서 노이즈를 제거하고 영상을 개선하는 방법으로서 MRF 기반의 최적화 알고리즘을 적용하는 영상 개선 기법을 제시한다.

Implementation of Multi-frame Medical Image Labeling Web Application for Swallowing Disorder Analysis (삼킴장애 분석을 위한 멀티프레임 의료영상 라벨링 웹 애플리케이션 구현)

  • Dong-Wook Lim;Chung-sub Lee;Si-Hyeong Noh;Chul Park;Min Su Kim;Hee-Kyung Moon;Chang-Won Jeong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.05a
    • /
    • pp.8-10
    • /
    • 2023
  • 삼킴장애는 음식물이 입에서 식도로 가지않고 걸리거나 기도(Trachea)로 흡입되는 문제를 갖는 상태이다. 특히 노인이나 신경계 질환을 앓는 환자의 경우 기도로 흡입된 음식덩이가 폐렴을 일으키고 결국에는 사망으로 이어지기에 적절한 치료와 관리가 요구된다. 보통 영상으로 판단할 수 있는 삼킴단계는 구강준비단계(Oral Preparatory Phase), 구강단계(Oral Phase), 인두단계(Pharyngeal Phase), 식도단계(Esophageal Phase) 4가지로 분류하고 삼킴장애는 침습(Penetration)과 흡인(Aspiration)으로 크게 2가지로 분류한다. 본 논문에서는 이러한 6가지 클래스를 가지는 삼킴장애 환자 비디오 파일을 라벨링하기 위한 웹 애플리케이션을 제안한다. 이를 구현하기 위해서 대용량 멀티프레임 이미지를 수신해서 분리하여 저장하도록 개발하였다. 또한 음식덩이를 정교하게 분할할 수 있도록 GrabCut 알고리즘을 적용하여 라벨링할 수 있도록 하였다. 차후 라벨러와 전문의 간의 협업이 가능하도록 라벨링 데이터의 상태를 관리할 수 있도록 개발하고자 한다.

3D Medical Data Specification and Visualization Based on XML (XML 기반의 3차원 의료 데이터의 명세 및 가시화)

  • Kim, Seung-Wan;Park, Deok-Gyu;Gwun, Ou-Bong;Lee, Kun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.10 no.4
    • /
    • pp.6-12
    • /
    • 2004
  • 웹은 플랫폼에 의존하지 않고 모든 사람들이 공통으로 이용할 수 있는 인터페이스를 제공하기 때문에 웹브라우저상에 3차원 의료 데이터를 가시화하여 표현한다면 원격 진단, 의료 교육 등에 이용될 수 있다. 이 논문은 3차원 의료정보를 3차원 의료 볼륨 데이터, 3차원 의료 영상, 볼륨 렌더링 응용의 3 종류로 구분하여 이들을 XML로 표현하는 방법 및 텍스처 맵핑 기반의 디렉트볼륨렌더링(Direct Volume Rendering)을 SVG(Scalable Vector Graphics)으로 표현하여 SVG 뷰어 상에 표시하는 방법을 제안한다. 제안 방법의 실행 결과는 웹 브라우저 상에서 의료데이터의 분석이 가능하게 하고, 또한 볼륨렌더링 응용프로그램을 SVG로 표현, 결과 이미지를 SVG 뷰어로의 표시가 가능하다는 것을 보여준다.

  • PDF

Image Analysis Using Digital Radiographic Lumbar Spine of Patients with Osteoporosis (골다공증 환자의 Digital 방사선 요추 Image를 이용한 영상분석)

  • Park, Hyong-Hu;Lee, Jin-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.362-369
    • /
    • 2014
  • This study aimed to propose an accurate diagnostic method for osteoporosis by realizing a computer-aided diagnosis system with the application of the statistical analysis of texture features using digital images of lateral lumbar spine of patients with osteoporosis and providing reliable supplementary diagnostic information by model experimental research for early diagnosis of diseases. For these purposes, digital images of lateral lumbar spine of normal individuals and patients with osteoporosis were used in the experiments, and the values of statistical texture features on the set ROI were expressed in six parameters. Among the texture feature values of the six parameters of osteoporosis, the highest and lowest recognition rates of 95 and 80% were shown in average gray level and uniformity, respectively. Moreover, all the six parameters showed recognition rates of over 80% for osteoporosis: 82.5% in average contrast, 90% in smoothness, 87.5% in skewness, and 87.5% in entropy. Therefore, if a program developing into a computer-aided diagnosis system for medical images is coded based on the results of this study, it is considered possible to be applied to preliminary diagnostic data for automatic detection of lesions and disease diagnosis using medical images, to provide information for definite diagnosis of diseases, to diagnose by limited device, and to be used to shorten the time to analyze medical images.

Clinical application of factor analysis GOD monitor video output and S-curve model (GOD모델과 S-curve모델을 적용한 임상용 모니터 영상출력인자 분석)

  • Kim, Seon-chil;Kwon, Mun-gi;Jang, Ji-pil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.9-12
    • /
    • 2015
  • 임상용 모니터의 출력값 중 가장 큰 영향을 주는 것이 휘도이다. 최근 컬러 모니터의 임상용 사용으로 인해 출력값의 보정은 매우 중요하게 관리되고 있다. 색보정 변위의 특성화가 휘도와 동일한 인자로 영향을 주는지 분석하기 위해 사용된 특성화 보정 모델은 GOG모델과 S-curve모델 이다. 두 개의 모델을 통해 모니터의 휘도는 장치의 출력과 직접적인 관계가 있다는 것을 증명하고 동일한 출력에 입력값을 가질 수 있도록 구성하고자 한다. 동일한 출력을 디스플레이 할 경우 동일한 출력값을 얻어야 한다. 그러나 모니터에 따라 서로 다른 출력값을 산출한다. 컬러모니터의 경우는 출력의 안정성에 휘도뿐만 아니라, 색감(R,G,B) 변화가 큰 역할을 수행한다. 본 연구에서는 분석인자 중 대조도에 영향을 주는 인자를 역추적하여 특성화 보정 S-curve모델을 LCD에 적용하였다. 이는 GOG모델을 적용한 CRT와 동일한 결과를 얻었다. 따라서 인자는 CIEXYZ의 결과값과 동일한 인자를 구할 수 있다.

  • PDF