• Title/Summary/Keyword: 유효 길이

Search Result 578, Processing Time 0.025 seconds

Experimental Extraction of Effective Permittivity on the Structures of Coplanar Waveguides (코프래너 도파로 구조에서 S-파라메터를 이용한 유효유전상수 실험적 도출)

  • 지용
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.11
    • /
    • pp.15-20
    • /
    • 2004
  • This paper proposed a very simple method of extracting an effective permittivity from the data of scattering parameters measured on the transmission line of coplanar waveguides in the frequency range of microwave or millimeter waves. This is an extracting method of an effective permittivity $\varepsilon$$_{eff}$ in the case of $\beta$$\ell$ =n$\pi$ (n=integer), where the value of S$_{11}$ changes abruptly following the operating frequency. The experimental value of the effective permittivity $\varepsilon$$_{eff}$ on a dielectric substrate of Rogers 4003$^{TM}$ material of $\varepsilon$$_{r}$ =3.38 showed the value of 2.042, which differs in the error of -3.4% to 8% from those calculated from the previously reported formulae. This result showed that the measurement method was very simple, as well as applied directly to the fabricated circuit patterns, even though the circuit patterns might be complicated or on the substrate of different dielectric materials.s.als.

The Effect of Pressure and Hose Length on the Travelling Distance of Particles in Power Sprayer (토출압력(吐出壓力) 및 호오스길이가 도달성(到達性)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Kwon, Soon Hong;Choi, Kyu Hong
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.30-35
    • /
    • 1983
  • To investigate the factors affecting the transportability of spray droplets, the maximum distance, the effective distance, the ratio of even distribution, and the diameters of particles were measured in accordance with the different pressure levels of power sprayer using 3 hole swath type nozzle, and the results are summerized as follows; 1. The distance of the most dense point from the nozzle was shortened by 0.5 meter with the 100-meter-long hose. The maximum reaching distances were reduced by 1.5 and 1.0 meters for the 13m/m and the 8.5 m/m hoses respectively, and the effective distance were reduced by 0.5 meter for both cases. 2. The effective distance can not be extended beyond 14 meters even if the length of hose is minimized at the rated pump pressure 28 kg/$cm^2$, it was 1 meter longer for 13m/m hose compared to the 8.5m/m one. 3. In case of 13m/m hose, the most dense point can be extended further by 0.5 meter increasing the pump pressure by 8 kg/$cm^2$, and the maximum distance and effective distance were increased by 2.0 and 0.5 meters respectively. There was no significant effect of pressure changes on the transportability in case of 8.5m/m hose. 4. Both the reduction of hose length and the increase of pump pressure influenced in large extent to the atomization effect of droplets. It was noticed that the diameter of droplet is related to the pump pressure and inside diameter of hose. 5. The pressure drop in 100-meter-long and l3m/m hose was 5~7kg/$cm^2$ at the pump pressure range of 25~33kg/$cm^2$, and it is an equivalent of 2% per 10 meter length of hose.

  • PDF

An Improved Stability Design of Plane Frames using System Buckling and Second-order Elastic Analysis (탄성좌굴 고유치 및 2차 탄성해석법을 이용한 평면강절프레임의 개선된 좌굴설계법)

  • Song, Ju-Young;Kyung, Yong-Soo;Kim, Nam-Il;Kim, Moon-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.2
    • /
    • pp.159-168
    • /
    • 2005
  • An improved stability design method for beam-columns of plane frames is proposed based on system buckling analysis and second-order elastic analysis. For this, the tangent stiffness matrix of beam-column elements is first derived using stability functions and a procedure for evaluating effective buckling lengths is reviewed using elastic system buckling analysis. And then the second-order analysis procedure is presented considering $P-\Delta$ effects and is compared with the closed-form solution through numerical examples. Design examples showing the validity of the proposed method we presented and their numerical results are compared with those obtained from the conventional stability design methods. Finally some useful conclusions are drawn.

Experimental Study on Bond Strength between Carbon Fiber Sheet and Concrete (탄소섬유쉬트와 콘크리트의 부착강도 실험연구)

  • 유영찬;최기선;최근도;이한승;김긍환
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.2
    • /
    • pp.168-174
    • /
    • 2001
  • Carbon fiber sheet(CFS) has been widely used for strengthening of the concrete building structures due to its excellent physical properties such as high strength, light weight and high durability. Bond strength or behavior, on the other hands, between carbon fiber sheet and concrete is very important in strengthening the concrete member using CFS. Therefore the bond failure mechanism between CFS and concrete should be fully verified and understood. This study is to investigate the bond strength of CFS to the concrete by the direct pull-out test and the tensile-shear test. In the direct pull-out tests, the bond strength under the various environmental conditions such as curing temperature, surface condition on concrete and water content of concrete are evaluated. Also, the effective bond length, lu and the average bond stress, $\tau$y are examined in the tensile-shear tests. Based on the test results, it is concluded that the curing temperature is the most critical element for the bond strength between CFS and concrete. And, the proper value of lu and $\tau$y is recommended with 15 cm and 9.78∼ 11.88 kgf/$\textrm{cm}^2$ respectively.

Improved Stability Design of Plane Frame Members (평면프레임 구조의 개선된 좌굴설계)

  • Kim, Moon Young;Song, Ju Young;Kyung, Yong Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.225-237
    • /
    • 2006
  • Based on the study conducted by Kim et al. (205a, b), an improved stability design method for evaluating the effective buckling lengths of beam-column members is proposed herein, using system elastic/inelastic buckling analysis and second-order elastic analysis. For this purpose, the stress-strain relationship of a column is inversely formulated from the reference load-carrying capacity proposed in design codes, so as to derive the tangent modulus of a column as a function of the slenderness ratio. The tangent stiffness matrix of a beam-column element is formulated using the so-called "stability functions," and elastic/inelastic buckling analysis Effective buckling lengths are then evaluated by extending the basic concept of a single simply-supported column to the individual members as one component of a whole frame structure. Through numerical examples of several structural systems and loading conditions, the possibilities of enhancement in stability design for frame structures are addressed by comparing their numerical results obtained when the present design method is used with those obtained when conventional stability design methods are used.

An Improved Stability Design of Cable-Stayed Bridges using System Buckling and Second-Order Elastic Analysis (활하중의 영향을 고려한 시스템 좌굴해석 및 2차 탄성해석을 이용한 사장교의 개선된 좌굴설계)

  • Kyung, Yong Soo;Kim, Moon Young;Chang, Sung Pil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3A
    • /
    • pp.485-496
    • /
    • 2006
  • Practical stability design method of main members of cable-stayed bridges is proposed and discussed through a design example. For this purpose, initial tensions of stay cables and axial forces of main members are firstly determined using initial shaping analysis of bridges under dead loads. And then the effective buckling length using system elastic/inelastic buckling analysis and bending moments considering $P-{\delta}-{\Delta}$ effect by second-order elastic analysis are calculated for main girder and pylon members subjected to both axial forces and moments, respectively. Particularly, three load combinations of dead and live loads, in which maximum load effects due to live loads are obtained, are taken into account and effects of live loads on effective buckling lengths are investigated.

The Extraction Method of LDD NMOSFET's Metallurgical Gate Channel Length (LDD NMOSFET의 Metallurgical 게이트 채널길이 추출 방법)

  • Jo, Myung-Suk
    • Journal of IKEEE
    • /
    • v.3 no.1 s.4
    • /
    • pp.118-125
    • /
    • 1999
  • A capacitance method to extract the metallurgical channel length of LDD MOSFET's, which is defined by the length between the metallurgical junction of substrate and source/drain under the gate, is presented. The gate capacitances of the finger type and plate type LDD MOSFET gate test patterns with same total gate area are measured. The gate bias of each pattern is changed, and the capacitances are measured with source, drain, and substrate bias grounded. The differences between two test pattern's capacitance data are plotted. The metallurgical channel length is extracted from the peak data at a maximum point using a simple formula. The numerical simulation using two-dimensional device simulator is performed to verify the proposed method.

  • PDF

Analysis of DIBL Characteristics for Double Gate MOSFET Using Series (급수를 이용한 DGMOSFET의 DIBL 특성 분석)

  • Han, Ji-Hyung;Jung, Hak-Kee;Jeong, Dong-Soo;Lee, Jong-In;Kwon, Oh-Shin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.709-711
    • /
    • 2011
  • 본 연구에서는 Double-gate MOSFET의 DIBL(Drain Induced Barrier Lowering)의 특성을 분석하기 위하여 분석학적 전송모델을 사용하였으며 분석학적 모델을 유도하기 위하여 포아송방정식을 풀 때 급수함수를 이용하였다. 단채널 효과에서는 유효채널길이 감소와 문턱전압 감소 그리고 DIBL이 있다. DIBL은 드레인 전압 변화에 따른 문턱전압의 변화로 알 수 있다. 채널길이가 감소하면 DIBL은 감소하지만, 채널길이가 감소하면 단채널 효과가 증가한다. 본 논문에서는 채널길이에 따른 DIBL을 분석하였고, 또한 채널 두께 및 게이트 산화막의 두께에 대한 DIBL에 대하여 분석하였다.

  • PDF

Longitudinal Control of Acceleration Lanes and its Impact on Congestion Alleviation (가속차로의 길이 제어와 고속도로 접속부 혼잡저감 효과)

  • Shin, Chi-Hyun;Kim, Kyu-Ok
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.5 s.83
    • /
    • pp.169-176
    • /
    • 2005
  • This paper introduces the dynamic control of acceleration lanes at freeway-ramp junctions. The feasibility of operation with flexible length of acceleration lane was tested with most possible traffic conditions. The operational qualify was also evaluated using average speed and total thru-put at both ramp section and freeway section. A CORSIM microscopic simulation model was used to evaluate the operation quality with a variety or volume conditions and three acceleration lanes, each representing different length categories. In addition, tollgate O-D data including travel times were obtained for two sections on the Gyeong-bu Freeway where an effective merging distance has been largely reduced. Its effect was analyzed and compared to the simulation results. Finally, the effects of acceleration lane are discussed and operational improvement at junctions is presented as research findings.