• Title/Summary/Keyword: 유효염소

Search Result 52, Processing Time 0.037 seconds

Disinfection Effect of Chlorine Dioxide on Pathogenic Bacteria from Marine Fish (이산화염소의 해산어류 병원세균 살균효과)

  • 박경희;오명주;김흥윤
    • Journal of Aquaculture
    • /
    • v.16 no.2
    • /
    • pp.118-123
    • /
    • 2003
  • This study was conducted to investigate the disinfection effects of chlorine dioxide ($ClO_2$) on 4 fish pathogenic bacteria (Vibrio anguillarum, Edwardsiella tarda, Streptococcus sp. and Staphylococcus sp.) isolated from infected olive flounders. The bacteria were exposed to different concentrations of ClO$_2$ (0.129, 0.246 and 0.455 ppm) and response times (0.5, 1, 3, 5 and 10 min), and then were incubated for 12 hr. The effective disinfection concentrations of $ClO_2$ against experimental bacteria by $ClO_2$ for 0.5 min were observed with 0.455 ppm for Staphylococcus sp., 0.246 ppm for V. anguillarum and E. tarda, and 0.129 ppm for Streptococcus sp., respectively. The duration of exposure at low concentration of $ClO_2$ increased for the disinfectant ability to experimental bacteria.

Study on Reduction of Microbial Contamination on Daruma by Combination Treatment of Strong Acidic Hypochlorous Water and Ultrasonic Waves (강산성차아염소산수와 초음파를 병용처리한 조미오징어 반가공품의 미생물 오염도 저감화에 관한 연구)

  • Chung, Won-Hee;Ko, Jun-Soo;Shin, Il-Shik
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.166-172
    • /
    • 2015
  • This study was performed to develop treatment method for reducing microbial contamination on Daruma (a semi-processed product of seasoned and dried squid) by combination of strong acidic hypochlorous water (SAHW) and ultrasonic waves (UW). The available chlorine concentration, oxidation reduction potential (ORP) and pH of SAHW were $69.67{\pm}0.58ppm$, $1071.33{\pm}4.16mV$ and 2.79, respectively. The 1.49 log CFU/g of viable cell count and 1.32 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of sodium hypochlorite solution (SHS) for 120 min. The 3.62 log CFU/g of viable cell count and 3.22 log CFU/g of Staphylococcus aureus was reduced, and Escherichia coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 120 min. The antibacterial effects of SAHW were stronger than those of SHS at same available chroline concentration. SAHW treatment after washing strongly alkalic electrolyzed water (SAEW) showed better bactericidal effects than SAHW treatment only. The 4.0 log CFU/g of viable cell count was reduced, S. aureus was reduced below regulation limit (Log 2.0 CFU/g), and E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 90 min after washing with 20 times (w/v) of SAEW for 60 min. The viable cell number was reduced below detection limit and S. aureus was reduced below regulation limit when the Daruma was treated with 20 times (w/v) of SAHW for 60 min in ultrasonic washer. E. coli was reduced below detection limit when the Daruma was treated with 20 times (w/v) of SAHW for 10 min in ultrasonic washer. These results suggest that combination of SAHW and UW may be a good technique to reduce the microbial contamination in daruma.

Experimental study of NOx reduction in marine diesel engines by using wet-type exhaust gas cleaning system (선박용 디젤엔진의 NOx를 저감하기 위한 습식 배기가스 처리기술 적용에 관한 실험적 연구)

  • Ryu, Younghyun;Kim, Taewoo;Kim, Jungsik;Nam, Jeonggil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.216-221
    • /
    • 2017
  • Diesel engines have the highest brake thermal efficiency among internal combustion engines. Therefore, they are utilized in medium and large transportation vehicles requiring large amounts of power such as heavy trucks, ships, power generation systems, etc. However, diesel engines have a disadvantage of generating large quantities of nitrogen oxides during the combustion process. Therefore, the authors tried to reduce the amount of nitrogen oxides in marine diesel engines using a wet-type exhaust gas cleaning system utilizing the undivided electrolyzed seawater method. In this method, electrolyzed seawater in injected into the harmful gas discharge from the diesel engine using real seawater. The authors investigated the reduction of NO and NOx from the pH value, available chlorine concentration, and the temperature of electrolyzed seawater. The results of this experiment indicated that when the electrolyzed seawater is acidic, the NO oxidation rate in the oxidation tower is higher than that when the electrolyzed seawater has a neutral pH. Likewise, the NO oxidation rate increased with the increase in concentration of chlorine. Further, it was confirmed that the electrolyzed seawater temperature had no effect on the NO oxidation rate. Thus, the NOx exhaust emission value produced by the diesel engine was reduced by means of electrolyzed seawater treatment.

Characteristics of Strong Alkaline Electrolyzed Water Produced in All-in-one Electrolytic Cell (일체형 전해조에서 생산된 강알카리성 전해수의 특성)

  • Lee, Ho Il;Rhee, Young Woo;Kang, Kyung Seok
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.446-450
    • /
    • 2012
  • Strong alkaline electrolyzed water which is produced in cathode by electrolyzing the solution where electrolytes (NaCl, $K_2CO_3$ etc.) are added in diaphragm electrolytic cell, is eco-friendly and has cleaning effects. So, it is viewed as a substitution of chemical cleaner. In addition, strong alkaline electrolyzed water is being used by some Japanese automobile and precision parts manufacturing industries. When strong alkaline electrolyzed water is produced by using diaphragm electrolytic cell, it is necessarily produced at the anode side. Since strong acidic electrolyzed water produced is discarded when its utilization cannot be found, production efficiency of electrolyzed water is consequently decreased. Also, there is a weakness electrolytic efficiency is decreasing due to the pollution of diaphragm. In order to overcome this, non-diaphragm all-in-one electrolytic cell integrated with electrode reaction chamber and dilution chamber was applied. Strong alkaline electrolyzed water was produced for different composition of electrolytes, and their properties and characteristics were identified. In comparing the properties between strong alkaline electrolyzed water produced in diaphragm electrolytic cell and that produced in all-in-one electrolytic cell, the differences in ORP and chlorine concentration were found. In emulsification test to confirm surface-active capability, similar results were obtained and strong alkaline electrolyzed water produced in non-diaphragm all-in-one electrolytic cell was identified to be useable as a cleaner like strong alkaline electrolyzed water produced in diaphragm electrolytic cell. Strong alkaline electrolyzed water produced in non-diaphragm all-in-one electrolytic cell is thought to have sterilizing power because it has active chlorine which is different from strong alkaline electrolyzed water produced in diaphragm electrolytic cell.

Soil Texture, Electrical Conductivity and Chemical Components of Soils under the Plastic Film House Cultivation in Northern Central Areas of Korea (중북부지역(中北部地域) 시설원예지(施設園藝地) 토양(土壤)의 토성(土性), 염농도(鹽濃度) 및 화학성분(化學成分)의 조성(組成))

  • Jung, Goo-Bok;Ryu, In-Soo;Kim, Bok-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.27 no.1
    • /
    • pp.33-39
    • /
    • 1994
  • This survey was conducted to investigate the factors affecting on salt accumulation and chemical components of soils cultivated with horticulture crops in plastic film houses. The soil samples were taken from 40 sites in the northern central areas of Korea and were analyzed for the chemical properties and soil separates. The data were evaluated with soil texture and years of cultivation as major factors. The results are summarized as follows : 1. The chemical properties of surface soils in plastic film house were pH 5.80, EC $3.59mScm^{-1}$, O.M. 4.20%, Av. $P_2O_5$ 1,178ppm, $NO_3-N$ 180ppm, Av. $SO_4{^{2-}}$ 353ppm, $Cl^-$ 240ppm, Ex. Na 0.40me/100g. 2. Compared to the outside soil of plastic film house, the inside soil had 2.5~3 times higher contents of $NO_3-N$, Av. $SO_4{^{2-}}$ and $Cl^-$, 1.2~1.8 times higher exchangeable base elements, and 2.8 times higher electrical conductivity. But pH value of the inside soil was lower than the outside soil by 0.3 pH unit. 3. Soil texture classification showed that sandy loam, loam and silt loam were 32.5 %, 37.5 %, and 30.0 %, respectively. The contents of $NO_3-N$, Av. $SO_4{^{2-}}$, $NH_4-N$ and EC value were very high in silt loam soils. Av. $P_2O_5$ content and pH value of sandy loam soils were higher than those of silt loam and loam soils. 4. The contents of O.M. and Av. $P_2O_5$ were higher in long term cultivation, but the contents of $NO_3-N$, Av. $SO_4{^{2-}}$, $Cl^-$, Ex. Mg and Ex. Na including EC of the soil with 2~4 years cultivation were higher than those of the soil with above 5 years cultivation. 5. Multiple linear regression analysis showed that contribution degree of soil chemical properties to the EC was high in the order of $NO_3-N$ > Av. $SO_4{^{2-}}$ > Ex. Na > $Cl^-$ > Av. $P_2O_5$ > $NH_4-N$ > Ex. Mg>Ex. Ca. Among the soil chemical properties the contribution of anions was remarkably high. 6. EC value correlated with ${\sum}A$(total content of anions)as $r=0.932^{**}$ and with ${\sum}C$(total content of cations) as $r=0.452^{**}$.

  • PDF

Reliability Analysis of Chloride Ion Penetration based on Level II Method for Marine Concrete Structure (해양 콘크리트 구조물에 대한 Level II 수준에서의 염소이온침투 신뢰성 해석)

  • Han, Sang-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.129-139
    • /
    • 2008
  • Due to uncertainty of numerous variables in durability model, a probalistic approach is increasing. Monte Carlo simulation (Level III method) is an easily accessible method, but requires a lot of repeated operations. This paper evaluated the effectiveness of First Order Second Moment method (Level II method), which is more convenient and time saving method than MCS, to predict the corrosion initiation in harbor concrete structure. Mean Value First Order Second Moment method (MV FOSM) and Advanced First Order Second Moment method (AFOSM) are applied to the error function solution of Fick's second law modeling chloride diffusion. Reliability index and failure probability based on MV FOSM and AFOSM are compared with the results by MCS. The comparison showed that AFOSM and MCS predict the similar reliability index and MV FOSM underestimates the probability of corrosion initiation by chloride attack. Also, the sensitivity of variables in durability model to corrosion initiation probability was evaluated on the basis of AFOSM. The results showed that AFOSM is a simple and efficient method to estimate the probability of corrosion initiation in harbor structures.

A Study on the Mitigation of Threat Zones for Indoor Chlorine Release using Effective Leakage Areas of Building and Box Model (건물의 유효누출면적 및 박스모델을 이용한 염소 실내 누출의 위험지역 완화에 관한 연구)

  • Kwak, Sollim;Lee, Eunbyul;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2018
  • It is difficult to determine the outdoor toxic level of hazardous chemicals that are leaked in the building, since there are no efficient ways to calculate how much percentage of the leaked chemicals is released into the outdoor atmosphere. In address to these problems, we propose a reasonable box model that can quantitatively evaluate the mass rate of the indoor chlorine leakage into the outside of the building. The proposed method assumes that the indoor chlorine leakage is fully mixed with the indoor air, and then the mixture of the chlorine and indoor air is exfiltrated into the outside of the building through effective leakage areas of the building. It is found that the exfiltration rate of the mixture of the chlorine and indoor air is strongly dependent on the temperature difference between inside and outside the building than the atmospheric wind speed. As compared with a conventional method that uses a vague mitigation factor, our method is more effective to evaluate the outdoor toxic threat zone of the chlorine that are leaked in the building, because it can consider the degree of airtight of the building in the evaluation of the threat zone.

Simulation for Chlorine Residuals and Effect of Rechlorination in Drinking Water Distribution Systems of Suwon City (수원시 상수관망에서 잔류염소와 재염소주입의 효과 예측)

  • Kim, Kyung-Rok;Lee, Byong-Hi;Yoo, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.108-116
    • /
    • 2000
  • Chlorine is widely used as a disinfectant in drinking-water systems throughout the world. Chlorine residual was used as an indicator for prediction of water quality in water distribution systems. The variation of chlorine residual in drinking water distribution systems of Suwon city was simulated using EPANET. EPANET is a computerized simulation model which predicts the dynamic hydraulic and water quality behavior within a water distribution system operating over an extended time period. Sampling and analysis were performed to calibrated the computer model in 1999 (Aug. Summer). Water quality variables used in simulations are temperature, roughness coefficient, pipe diameter, pipe length, water demand, velocity and so on. Extended water residence time affected water quality due to the extended reaction time in some areas. All area showed the higher concentration of chlorine residual than 0.2mg/l(standard). So it can be concluded that any area in Suwon city is not in biological regrowth problem. Rechlorination turned out to be an useful method for uniform concentration of free chlorine residual in distribution system. The cost of disinfectant could be saved remarkably by cutting down the initial chlorine concentration to the level which guarantees minimum concentration (0.2mg/l) throughout the distribution system.

  • PDF

Assessment of Both Standard and Isolated Vibrio parahaemolyticus on Efficacy of Commercial Sanitizers and Disinfectants (Vibrio parahaemolyticus 표준 및 식품분리 균주에 대한 살균소독제 유효성분별 감수성 평가)

  • Kim, Il-Jin;Kim, Yong-Su;Kim, Hyung-Il;Choi, Hyun-Chul;Jeon, Dea-Hoon;Lee, Young-Ja;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.2
    • /
    • pp.127-131
    • /
    • 2007
  • This study evaluated the bactericidal effect of 10 sanitizers and disinfectants such as ethanol (75 and 95%), iodine (15 and 25 ppm), chlorine (100 and 200 ppm), quaternary ammonium, acid, hydrogen peroxide, and peroxide acetic acid against V. parahaemolyticus. Ten strains of V. parahaemolyticus isolated from Korean foods and 4 strains of standard V. parahaemolyticus were compared for efficacies of various sanitizers and disinfectants by EN 1276 method based on quantitative suspension test. Ethanol (75 and 95%), 25 ppm of iodine, 100 ppm of quaternary ammonium, 145 ppm of hydrogen peroxide and acid showed more than $5log_{10}CFU/mL$ reduction in both clean and dirty conditions. Tests result of chlorine (100 ppm) showed more than $5log_{10}CFU/mL$ reduction in clean condition. Iodine (15 ppm) showed more than $5log_{10}CFU/mL$ reduction except 4 isolated and 1 standard V. parahaemolyticus in clean condition. iodine (15 ppm) also showed under $5log_{10}CFU/mL$ reduction $(0.93{\sim}3.73log_{10}CFU/mL)$ in dirty condition. Eleven hundred ppm of hydrogen peroxide was evaluated as weak sanitizer and disinfectant due to their $0.99{\sim}4.79log_{10}CFU/mL$ reduction on both clean and dirty conditions. Consequently, ethanol, iodine (25 ppm), chlorine (200 ppm), quaternary ammonium, acid and peroxide acetic acid were thought to be effective sanitizer and disinfectant against V. parahaemolyticus.

Movement Of Applied Nutrients Through Soils By Irrigation -2. Effect of soil water on the movement of Cl and P in the soil (관수(灌水)에 의(依)한 시비양분(施肥養分)의 토양중(土壤中) 이동(移動)에 관(關)한 연구(硏究) -2. 토양수분(土壤水分) 조건(條件)과 Cl와 P의 이동(移動))

  • Ryu, Kwan Shig;Yoo, Sun Ho;Song, Kwan Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.24 no.3
    • /
    • pp.159-164
    • /
    • 1991
  • A field microplot(D 20cm, L 85cm) experiment filled with Bonryang sandy loam soil (Typic Udifluvents) was conducted to obtain quantitative information on the movement of applied nutrients under diffetent soil moisture regimes and ladino clover cultivation. Chloride moved rapidly with soil water. When soil moisture tension was maintained at loer than 0.2 bar most of the Cl appeared to move outside the microplot 4 month after the microplot installation. Regardless of soil moisture condition, Cl was not detected in the soil due to the fast movement of the Cl beyond the microplot after 5.5 months Although large amount of P and water were applied to the soil of high available P during the field experiment, movement of P was negligible and most of P remained in thc place where applied due to the low solubility of the fused and superphosphate. Phosphate in the soil extracted by Bray No.1 solution and taken up by plant increased with soil moisture. Under the condition of irrigation at 0.2 bar, plant took up 23% of the applied P, and 24% of the P was extracted by Bray NO.1 solution, while plant took up 14% and 13% of the P was turned out to be Bray No.1 P. at thc nonirrigated condition after final harvest.

  • PDF