Runoff Analysis of Urban Watershed using MIKE SWMM Model (MIKE SWMM 모형을 이용한 도시유역 유출분석에 관한 연구)

  • Kim, Jong-Suk;Ahn, Jae-Hyun;Oh, Tae-Suk;Moon, Young-Il
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.11
    • /
    • pp.907-916
    • /
    • 2005
  • For an urban watershed modeling, the ILLVDAS and SWMM model were the popular rainfall-runoff models using in Korea. However, combined sewerage systems in urban area produce some problems when a flood event happens because of the surcharged precipitation amounts which drain to streams directly. Also, rack of pipe line data and difficulties of modeling yield inappropriate modeling results in urban runoff analysis. In addition, rainfall-runoff models in an urban which using channel routing could be inaccurate and complicated processes. In this paper, the MIKE SWMM model has been applied for a stable urban area runoff analysis. Watershed and pipe line data were established by using past inundated records, DEM data and numerical pipe line data. For a runoff modeling, the Runoff block was adapted to a basin and the Extran block using dynamic equation was applied for sewerage system. After a comparisons against existing models yield that the MIKE SWMM model produce reliable and consistence results without distorting parameter of the model.

Assessment of Harmonic Emission Limits for Customer at HV System (고압 수용가의 고조파 방출 한계 평가)

  • Wang, Yong-Peel;Jeon, Young-Soo;Kwak, No-Hong;Kim, Se-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.59-60
    • /
    • 2008
  • 비선형 부하의 급증으로 고조파로 인한 문제가 점차적으로 커지고 있으나 국내에서는 고조파 관리 기준 및 적용절차의 미비로 제대로 된 고조파 관리가 이루어지지 못하고 있다. 따라서 국내 송전계통에 연계되어는 있는 고압수용가에서 계통으로 유출할 수 있는 고조파 크기를 산정하는 프로그램이 필요하다. 국외에서는 IEC 61000-3-6 고조파 관리기준을 바탕으로 고압 수용가의 고조파 허용치 산정 알고리즘이 개발된 상태이다. 그러나 이 알고리즘을 국내 송전계통에 바로 적용할 수 없다. 따라서 이 알고리즘을 바탕으로 국내 송전계통 실정에 맞는 알고리즘으로 보완하고, 마이크로 소프트 엑셀 프로그램을 이용하여 고압 수용가 고조파 허용치 산정 프로그램을 개발하였다.

  • PDF

A Bayesian Approach to Storm Water Management Model (SWMM) for the Estimation of Parameters and Their Uncertainty (Bayesian 기법과 연계한 SWMM 매개변수 추정 및 불확실성 분석)

  • Kim, Jang-Gyeong;Ban, U-Sik;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.110-110
    • /
    • 2016
  • 도시 유역의 강우-유출 모의에는 지표 투수율 및 하수관거 영향 등 인위적 배수계통의 영향을 고려할 수 있는 도시유출모형이 널리 이용되고 있으며, 모형 검증을 통해 모의 성능을 평가한다. 도시유출모형의 검증은 일반적인 강우-유출 모형과 같이 강우사상별 유량의 관측시계열과 모의시계열의 목적함수가 최소가 되는 최적 매개변수를 탐색하는 과정이다. 도시유출모형의 검증에서 발생하는 문제점은 크게 다음과 같다. 첫째, 대규모 도시 유역의 복잡하고 다양한 하수관거에 대한 최적매개변수를 관거별로 구하는 것은 물리적으로 불가능하다. 따라서 동일 배수분구내 하수관거의 매개변수 값은 동일하다고 가정하거나, 모형 단순화 과정을 통해 매개변수의 물리적 범위 내에서 최적해를 탐색해야 하는 단순화에서 기인한 불확실성이 있다. 둘째, 다양한 매개변수들의 물리적 범위를 고려하기 위해서는 전역최적화기법이 유효하다. 그러나 전역최적화 종류, 목적함수, 모의횟수, 목표성능별 최적 매개변수 결과가 각각 다르므로 추정된 최적 매개변수의 범위에 대한 불확실성이 있다. 이에 본 연구에서는 Bayesian 모형과 EPA SWMM(Storm Water Management Model)을 연계하여 도시유출모형의 매개변수 불확실성을 정량적으로 분석할 수 있는 모형을 제안하고자 한다. 이를 위해 서울 우이천 유역을 대상으로 SWMM 모형을 구축하고, 절단 정규분포(truncated Gaussian distribution)를 사전분포(prior)로 가정하여 매개변수의 물리적 범위를 고려하였다. 최종적으로 결합확률분포로 계산된 각 매개변수간 사후분포를 통해 모의된 유출량의 불확실성을 정량적으로 분석하였다. 본 연구에서 제안된 모형은 대규모 도시 유역의 도시유출모형 구축 시 다양한 매개변수의 물리적 범위를 고려한 최적화와 동시에 내재된 불확실성을 정량적으로 분석할 수 있으므로, 침수예측 및 홍수예경보 등의 문제에서 상당한 신뢰성을 확보할 수 있을 것으로 판단된다.

  • PDF

Grid-based Estimation of Reservoir Flood Inflow using Radar Observed-Precipitation (레이다강우를 이용한 격자기반의 저수지 홍수유입량 모의)

  • Kang Boosik;Kim Seoyoung;Ko Ick-Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.183-188
    • /
    • 2005
  • 레이더강우관측의 수문학적 적용성을 검토하고 개념적 유출모형과 분포형 유출모형에서 지점강수 및 레이더강수를 적용하여 매개변수의 민감도 및 수문곡선변화를 관찰하였다. 레이더강수의 계통적오차는 총강수량비를 이용하여 보정하였고, 이결과 레이더강수가 지점강수에 비하여 첨두강수를 더욱 양호하게 표현하고 있음을 확인할 수 있었다. 지점강수와 레이더강수를 이용하여 용담댐 상류유역에 대한 유출해석을 수행하였다. 개념적모형으로는 저류함수모형을, 분포형모형으로는 실시간 홍수 조절을 목적으로 미국 Oklahoma대학에서 개발된 $V\;flo^{TM}$모형을 이용하여 테스트하였다. 결과 개념적 모형과 분포형모형 모두에서 경험식으로부터 구한 매개변수의 초기값을 이용한 수문곡선은 관측수문 곡선과 상당한 차이를 보이고 있었으나 분포형 수문곡선의 경우 천천상류지점의 수문곡선은 매개변수의 추가적 보정이 필요없을 정도로 매개변수의 초기값이 수문곡선을 잘 모의 하고 있었다. 이는 매우 고무적인 결과로서 실시간 홍수모형으로서 요구되는 중요한 특성과 동시에 물리적 기반의 분포모형의 가장 큰 장점일 수 있는 사상독립적 유역매개변수군을 구축하는데 중요한 단서가 될 것으로 보여진다.

  • PDF

Design of Tritium Handling System(II): Injection System, Regeneration System (삼중수소취급계통의 설계(II): 주입계통, 재생계통)

  • 김광신;김경숙;정은수;손순환;김위수
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.117-123
    • /
    • 2003
  • In succession to the previous paper, the tritium injection system and the regeneration system of the tritium handling system are presented. Both systems should be placed inside glove boxes since there can be potential leakage of tritium from these systems. The tritium injection system should be capable of measuring the exact amount of the injected tritium to keep track of the tritium inventory. The tritium injection system is designed to recover the remaining tritium from the system after injection for the minimization of tritum release to the environment as well as for the recovery of precious resource. TRS equipment such as MS, Ni catalyst bed, and metal getter are regenerated with a standalone regeneration system. Unlike other equipments which can be regenerated by heating and purging with appropriate gas, regeneration of the metal getter used to recover tritium is somewhat complicated.

  • PDF

Analysis of Total Loss of Feedwater Event for the Determination of Safety Depressurization Bleed Capacity (안전감압계통의 방출유량을 결정하기 위한 완전급수상실사고 해석)

  • Kwon, Young-Min;Song, Jin-Ho;Ro, Tae-Sun
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.470-482
    • /
    • 1995
  • The Ulchin 3&4, which are 2825 MWt PWRs, adopted Safety Depressurization System (SDS) to mitigate the beyond design basis event of Total Less of Feedwater(TLOFW). In this study the results and methodology of the analyses for the determination of SDS bleed capacity are discussed. The SDS design bleed capacity has been determined from the CEFLASH-4AS/REM simulation according to the following design criteria : 1) Each SDS flow path, in conjunction with one of two High Pressure Safety Injection (HPSI) pumps, is designed to have a sufficient capacity to prevent core uncovery if one SDS path is opened simultaneously with the opening of the Pressurizer Safety Valves (PSVs). 2) Both SDS bleed paths are designed to have sufficient total capacity with both HPSI pumps operating to prevent core uncovery if the Feed and Bleed (F&B) initiation is delayed up to thirty minutes from the time of the PSVs lift. To verify the results of CEFLASH-4AS/REM simulation a comparative analysis kas also been per-formed by more sophisticated computer code, RELAP5/MOD3. The TLOFW event without operator recovery and TLOFW event with F&B are analyzed. The predictions by the CEFLASH-4AS/REM of the transient too phase system behavior are in good qualitative and quantitative agreement with those by the RELAP5/MOD3 simulation. Both of the results of analyses by CEFLASH-4AS/REM and RELAP5/MOD3 have demonstrated that decay heat removal and core inventory make-up can be successfully accomplished by F&B operation during now event for the Ulchin 3&4.

  • PDF

Computation of Underground Storm Water Storage Facilities Volume for Reducing the Flood Damage in Urban Area (도시침수저감을 위한 지하저류조 용량 산정)

  • Han, Kun-Yeun;Son, In-Ho;Lee, Sang-Yeob;Im, Jae-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1007-1011
    • /
    • 2009
  • 도시지역에 있어서 홍수피해의 직접적인 원인으로는 외수의 범람에 의한 침수와 내수 배제 불량에 의한 침수피해로 구분할 수 있는데 최근 도시지역에 발생하는 홍수피해의 대부분은 외수의 직접 범람에 의한 피해보다는 각종 수리구조물의 배제능력 부족이나 방류지점에서의 배수위의 영향으로 인한 내수의 배제 불량에 기인한 피해가 증가하는 추세이다. 또한 최근 도시지역에 홍수피해를 유발하고 있는 강우의 특징은 단시간에 많은 강우가 집중하여 발생하는 국지성 집중호우로 단시간 내에 수공구조물의 기능을 마비시킴으로써 침수피해를 가중시키는 경향이 있으므로 배수시설 설계 시 이러한 강우의 특성과 도시유출 특성에 대한 고려가 요구되며 중요 시설물에 대해서는 설계빈도의 상향조정이 필요하다. 본 연구에서는 기존 도시유역에 적용되고 있는 강우-유출모형의 기본이론의 장 단점을 검토하여 본 연구의 목적과 용도에 가장 적합하다고 판단되는 SWMM 모형을 선정하여 적용하였다. 대구 서구 비산 7동 배수구역의 유출모의를 실시한바, 향후 경제적 편익을 고려하고, 정확한 실측 유량자료 값을 산정, 관거 내 유속을 방해하는 토사 등 보다 정확한 관거자료, 모의에 사용하는 각종 매개 변수값의 정확도를 높인다면 인위적인 배수계통을 가지는 도시유역에서의 각종 풍수해에 피해를 최소화 할 수 있는 보다 합리적인 방재대책 수립에 큰 도움을 줄 것으로 판단된다.

  • PDF

원자력발전소 1차계통 탈염기 제염계수 특성 분석

  • 성기방;강덕원
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.387-391
    • /
    • 1997
  • 냉각재중의 방사능을 띤 성분 중에는 이온교환기에서 제거가 가능한 이온성분과 함께 필터에 의해서 주로 제거되는 입자성 물질로 존재한다. 운전중의 냉각재내 방사성 부식생성물의 물리적 조성 분포 측정 결과에 따르면 90%이상이 0.45$mu extrm{m}$필터에 의해 제거되는 입자성 물질로 구성되어 있다. 이로 인해 새수지 충전후 얼마 사용하지 않은 탈염기의 제염계수가 탈염기에서 완벽한 제거가 어려운 입자성 부식생성물로 인해 10이하를 나타낼 수 있다. 1차계통에 쓰이는 수지의 성능검사를 위해 사용하고 있는 현재의 제염계수 측정법은 다음과 같은 두가지 이유로 완벽하지 않음을 알 수 있다. 첫째, 냉각재중의 방사능을 띤 성분중에는 이온교환기에서 제거가 가능한 이온성분과 함께 필터에 의해 제거되는 입자성 물질도 함께 존재하므로 탈염기의 제염계수 측정 절차는 입자성 물질을 배제한 후 측정해야 하며, 특히 수치 교체를 결정하기 위한 제염계수 측정시에는 여과된 여액으로 방사능 농도를 측정하는 것이 바람직하다. 둘째 운전중인 냉각재의 시료중에는 핵분열 수율이 높고 핵연료봉 손상부위로 유출이 용이한 불활성 기체핵종들이 많이 존재하며, 탈염기 후단에서 채취한 시료중에도 많이 존재하고, 시료 이송과 방사능 측정동안의 짧은 시간동안에도 계속 붕괴반응함으로서 새로 생긴 핵종으로 인해 마치 탈염기의 제거능이 낮은 것으로 오판될 수 있다. 이러한 측정 오차인자를 고려하여야 1차계통 탈염기의 교환능력을 정확히 판정할 수 있다.

  • PDF

Runoff Analysis for Urban Unit Subbasin Based on its Shape (유역형상을 고려한 도시 단위 소유역의 유출 해석)

  • Hur, Sung-Chul;Park, Sang-Sik;Lee, Jong-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.5
    • /
    • pp.491-501
    • /
    • 2008
  • In order to describe runoff characteristics of urban drainage area, outflow from subbasins divided by considering topography and flow path, is analyzed through stormwater system. In doing so, concentration time and time-area curve change significantly according to basin shape, and runoff characteristics are changed greatly by these attributes. Therefore, in this development study of FFC2Q model by MLTM, we aim to improve the accuracy in analyzing runoff by adding a module that considers basin shape, giving it an advantage over popular urban hydrology models, such as SWMM and ILLUDAS, that can not account for geometric shape of a basin due to their assumptions of unit subbasin as having a simple rectangular form. For subbasin shapes, symmetry types (rectangular, ellipse, lozenge), divergent types (triangle, trapezoid), and convergent types (inverted triangle, inverted trapezoid) have been analyzed in application of time-area curve for surface runoff analysis. As a result, we found that runoff characteristic can be quite different depending on basin shape. For example, when Gunja basin was represented by lozenge shape, the best results for peak flow discharge and overall shape of runoff hydrograph were achieved in comparison to observed data. Additionally, in case of considering subbasin shape, the number of division of drainage basin did not affect peak flow magnitude and gave stable results close to observed data. However, in case of representing the shape of subbasins by traditional rectangular approximation, the division number had sensitive effects on the analysis results.

Effect of in vitro Culture Condition and Lines on Growth Pattern of Lateral Bud from Nodal Cutting of Phalaenopsis Flower Stalk (팔레높시스 기내 화경 배양조건 및 계통이 액아의 발육형태에 미치는 영향)

  • 김미선;은종선;이영란
    • Korean Journal of Plant Tissue Culture
    • /
    • v.28 no.4
    • /
    • pp.189-195
    • /
    • 2001
  • This study was carried out to investigate the effects of in vitro culture condition and among lines on growth pattern of lateral buds from nodal cuttings of Phalaenopsis flower stalks. The ratio of bud growing into shoot from nodal cuttings of flower stalks were 90.9% and 54.4% on MS and hyponex medium, respectively. The number of buds grown vegetatively were increased remarkably on the MS medium containing 5 mg/L BA. The rate of buds grown vegetatively was higher in basal and middle parts than in upper part of flower stalks. The flower stalk sections cultured at 25~28$^{\circ}C$ showed the highest ratio of vegetative growth. Medium contamination was decreased by pretreatment of etiolation to the flower stalk. However, the pretreatment did not show specific effects on shoot development and reduction of phenolic compound. Average shoot number which was formed from flower stalk segments in 27 of 30 accessions were 3.17, while high number of shoots were obtained from Phal. 3020 and Phal. 3039. The growth pattern of lateral buds in F$_1$hybrids was similar to that of their parents.