• Title/Summary/Keyword: 유지 장치

Search Result 2,431, Processing Time 0.037 seconds

RETENTIVE FORCES OF CLASPS OF REMOVABLE ORTHODONTIC APPLIANCES FOR CHILDREN (어린이에게 사용되는 가철식 교정장치용 clasp의 유지력비교)

  • Han, Jeong-Jae;Lee, Kwang-Hee;Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.207-217
    • /
    • 1999
  • The purpose of this study was to compare the retentive forces of various types of clasps for removable orthodontic appliances for primary and mixed dentition. Seven metal models of a single tooth and two teeth were made, including maxillary left primary canine, first primary molar, second primary molar and first molar. Retentive forces of Adams clasp, circumferential clasp(C clasp), Jackson clasp, Duyzing clasp, arrowhead clasp, ball clasp, eyelet clasp, and triangular clasp were measured by Universal Testing Machine(Zwick Z020, Germany). The obtained results were as follows. 1. Jackson clasp and Adams clasp showed the highest retentive force among single tooth clasps. 2. C clasp showed the lowest retentive force, and there was no statistically significant difference in retentive force between mesial end C clasp and distal end C clasp. 3. Eyelet clasp showed the highest, and ball clasp showed the lowest retentive farce among clasps for interdental undercut. 4. Triangular clasp showed higher retentive force than ball clasp.

  • PDF

Removal Efficiency and Applicability Analysis of Suspended Solids in Nonpoint Source Reduction Equipment (비점오염원 저감장치의 부유물질 제거효율 및 적용성 분석)

  • Jang, Suk-Hwan;Lee, Jae-Gyeong;Lee, Hae-Gwang;Oh, Ji Hwan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.245-245
    • /
    • 2018
  • 최근 도시화 및 산업화의 발달로 불투수면적이 증가함에 따라 건기 시 토지 표면에 축적된 오염물질이 강우유출수와 함께 하천으로 유출되는 등 수질오염의 가중과 불특정 지역에서 발생하는 비점오염원의 집중관리가 필요한 실정이다. 우리나라는 환경기초시설 등의 건설로 점오염원 관리는 강화되었지만, 비점오염원의 부하량은 점차 증가되고 있는 추세이며, 환경부 및 관계부처에서는 비점오염관리를 위한 여러 정책을 추진 중에 있다. 국내에서 사용하고 있는 비점오염저감장치는 자연형 시설과 장치형 시설로 구분되는데, 이 중 장치형 시설은 필터를 사용하여 비점오염저감의 효율성을 증가시키지만, 필터를 사용함으로써 유지관리 및 경제적인 측면에서 매우 불리하다. 이에 본 연구에서는 필터가 없는 장치형 시설을 고안하여 자연 순환기능을 최대한 유지하고, 오염물질을 최적으로 제거할 수 있는 방안을 마련하고자 수리실험을 통해 비점오염원의 제거효율을 분석하였다. 수리학적 상사법칙에 따라 원형대비 1/3축소모형과 2가지의 원형모형에 대해 총 3가지 모형에 대해 환경부에서 고시한 비점오염저감장치 기준을 뛰어넘는 유역면적, 강우강도 및 부유물질의 양으로 실험을 진행하였다. 실험결과는 유입수 농도에 대한 유출수의 농도로 계산하였으며, 장치에서 유출 직후 5분 간격으로 채취한 후, 수질공정시험법을 참고하여 부유물질에 대한 실험 중 하나인 유리섬유여과방법을 이용해 실험 결과를 도출하였다. 실험 결과, 본 연구에서 고안한 장치형 시설은 필터를 사용하지 않음에도 불구하고 환경부 기준인 부유물질 제거효율 80%이상을 만족한 것으로 나타나 현재 사용하고 있는 장치형 시설보다 유지관리 및 경제성 등이 우수할 것으로 기대된다.

  • PDF

A Study on the Design of Alarms to Maintain the distance in the COVID-19 Era. (코로나19시대의 거리유지를 위한 경보기 디자인에 관한 연구)

  • Kang, Hee-Ra
    • Journal of Digital Convergence
    • /
    • v.20 no.4
    • /
    • pp.513-518
    • /
    • 2022
  • In the past two years, all sectors of society have been underdeveloped and suffered a significant damage due to COVID-19. In particular, people who were working in many areas of research were unable to do anything due to restrictions on meetings with people and social distancing. The purpose of this study is to develop a social distancing device that allows users to maintain the distance in accordance with the government guidelines through an analysis of people's social distancing methods in the COVID-19 society through UX Design. In order to develop the social distancing device, the distance is expressed by changing the color of LED based on research related to UI design such as ultrasonic distance sensor, battery, charging method, distance display method, etc. The outer form of the social distancing device is designed using 3D, the device is developed by installing ultrasonic distance sensor, neo-pixel module and Arduino after printing a prototype using a 3D printer, and this device is tested to develop a final product that helps the social distancing practice amid COVID-19.

Development of Tension Control Device for Yarn (방사장력 제어장치의 개발)

  • 양승현;이석원
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.11a
    • /
    • pp.166-168
    • /
    • 2001
  • 본 연구에서는 현재 직조 산업현장에서 전량 수입에 의존하고 있는 장력제어장치를 국산화할 목적으로 주변조건에 관계없이 정확하게 실의 장력과 실의 끊어짐을 감지할 수 있는 센서장치를 개발하고, 생산 제품의 조직 구성이 균일하게 이루어지도록 실의 공급속도에 따라서 일정한 장력을 유지시켜주는 제어 장치를 구성한다.

The Design and Manufacture for Wheelchair ABS (휠체어 ABS에 대한 설계 및 제작)

  • 김세환;이종선
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.106-109
    • /
    • 2003
  • 기존 휠체어에 정지상태 유지의 의미를 가지고 있는 휠체어 브레이크 장치를 대체할 수 있으며, 안정적인 제동력을 제공함으로 운행 중에 제동할 수 있는 휠체어 제동장치의 설계 및 제작을 목적으로 한다. 장치를 설계, 제작함에 있어 설계단계에서부터 가공기술자가 참가함으로서 공정변화를 유도하였다. 또한, 외측라체트 휠을 이용한 제동장치를 제작함으로서 기존의 설계제작에 따른 시행착오를 줄였다.

  • PDF

신호장치 유지보수를 위한 채널별 신호상태분석 알고리즘 개발

  • 윤달환;임제탁
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.3
    • /
    • pp.318-326
    • /
    • 1993
  • It is not easy to diagnose rapidly the cause of trouble in the signal service which is currently provided by the fully electronic switching system such as TDX. To solve these problems, it is necessary to acquire and analyze the service signal. This paper describes the development of PCM acquirer which can analyze the signal characteristics by acquiring the PCM signal in SHW(subhighway). Also an algorithm which analyzes the acquired signal and determines the signal frequency si discussed by using CZT.

  • PDF

Computational Simulation for Comparison of Flow Field and Particle Behavior in a Ceramic Candle Filter Housing with Different Inlet Type (세라믹캔들필터 집진장치에서의 입구유입방식에 따른 유동장 및 입자거동현상 비교 수치해석)

  • 박석주;이동근;임정환;박영옥
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.481-482
    • /
    • 2003
  • 세라믹캔들필터 집진장치의 형상 설계 시 장치내의 유동장의 균일도와 필터 표면으로의 입자 부하 현상이 중요한 설계 요소로 다루어지고 있다. 장치 내부의 유동 조건을 조절하여 필터 표면상에 도달하는 입자의 농도를 낮추거나 균일하게 유지시킬 경우, 부착된 입자층 두께의 성장으로 인한 압력손실의 증가율을 줄일 수 있고 이로 인하여 탈진 주기 또한 감소시킬 수 있다. 탈진 조작의 저감으로 인하여 필터의 수명 증대로 필터의 교체 시기를 연장시킬 수 있으므로 세라믹캔들필터 집진장치의 운전 및 유지보수비의 저감을 이룰 수 있다. (중략)

  • PDF

Using a Borehole Stability Device for Hydraulic Testing in Unconsolidated Alluvium (공벽 유지장치를 이용한 미고결 충적층의 수리특성 평가)

  • Won, Kyoung-Sik;Kim, Chunsoo;Chae, Soo-Yong;Shin, Dong-Min
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.15-22
    • /
    • 2016
  • Hydraulic falling head and slug tests were carried out in an alluvium aquifer using a borehole stability device. The hydraulic testing had proved difficult in alluvial formations of sands and gravels due to borehole collapse and unstable borehole walls within the test section. This study aims to improve the hydraulic test results by using a borehole stability device. The device can minimize the collapse of borehole walls, and the use of a filter with a constant opening ratio improves the calculations per unit area of the test section. Permeability obtained from the falling head test without a borehole stability device was 8.82 × 10−5m/sec. When the borehole stability device was installed in the same test section the measured permeability increased to 4.00 × 10−4m/sec, which is 4.5 times that obtained without the borehole device. The relatively low permeability obtained using the conventional test method is attributed to the presence of a fine-grained slime generated during drilling and a reduction of the test area in the test interval due to a gradual collapse of the borehole walls. This study considers how the use of a borehole stability device to prevent borehole collapse can influence the results of hydraulic tests in alluvial formations. It is expected that the results can be used as a basis for improving the reliability and applicability of hydraulic tests performed in alluvial aquifers.

배관 세척장치의 성능평가

  • 조정식
    • 월간 기계설비
    • /
    • s.119
    • /
    • pp.71-83
    • /
    • 2000
  • 점차 복잡해지고 있는 사회적 욕구를 만족시키기 위한 건물에서는 반드시 복잡한 설비가 요구되고 있고, 이러한 설비시스템 중에는 급수, 급탕 및 배수설비라고 하는 배관시스템이 없다면 기능유지에 막대한 지장을 초래할 것은 자명하다고 하겠다. 이러한 배관시스템에서는 항시 또는 일부 사용되어질 물이나 사용된 물이 흐르기 때문에 배관내부에 발생하는 스케일(scale)이나 슬라임(slime) 등은 피할 수 없는 사실인 것이다. 건축물 내에 설치된 각종 배관은 건물의 기능을 유지하고 보건위생과 직결되는 중요한 기능을 담당하고 있어 세척의 필요성이 매우 높음에도 불구하고 배관의 수명이 다할 때까지 거의 세척이 이루어지지 않고 사용되어 왔다. 이들 배관에 대한 세척은 배관의 수명연장과 관마찰 계수를 낮추어 급수의 수송동력을 절감할 수 있고, 난방관의 열전달 효과를 높여 에너지 절약 효과를 거두어 건물의 유지관리 비용 절감에 기여할 수 있음에도 적절한 세척공법이 개발되지 않고 있다. 이러한 관점에 맞추어 건물배관의 특성에 맞도록 고압 세척장치를 개발하고 이를 이용한 세척공법을 적용하고자 하였다. 즉, 배관 내에 압축공기를 주기적으로 분사하여 맥동현상이 일어나도록 하면서 기포를 발생시켜 기포가 관의 내벽에서 성장하여 파괴될 때 관내에 부착된 이물질을 제거할 수 있고, 또한 세척효과를 높이기 위하여 관의 벽면에 접촉하면서 배출되는 과정에서 이물질을 제거할 수 있도록 구조와 아울러 이들 장치를 이용한 세척방법의 적용성에 대해서 고찰하고자 한다.

  • PDF