• Title/Summary/Keyword: 유전정접

Search Result 37, Processing Time 0.025 seconds

The Structures and Dielectric Properties of Plasma Polymerized Polyethylene (플라즈마 중합 폴리에틸렌 구조와 유전특성)

  • 김두석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.38-42
    • /
    • 2000
  • Plasma polymerized thin films were manufactured inter-electrode coupled plasma polymerization apparatus. The deposition rate reached its maximum between 40[W] and 100[W]. In the ESCA analysis, peaks revealing -CH2, -CH, -C- were present at 285.4 and 285.5[eV] respectively. The C=O peak at 532.8[eV] and the C-O peak at 533.8[eV], which were grouped with an unignorable amount of oxygen were conformed. In ESR analysis, the curve revealing strong amplification was in saturation, which was affected by weak power. This is considered as a -CH-Ch=Ch- structure containing the Allyl group. The relative permittivity of the plasma polymerized thin films was about 3.5 at a frequency of 100[Hz]∼200[kHz]. The dissipation factor showed allow value of 0.008.

  • PDF

The preparation and characteristics of (Ba,Sr,Mg) $TiO_3$ ceramic for BL capacitor ((Ba,Sr,Mg)$TiO_3$를 이용한 입계층 캐패시터의 제작 및 유전특성에 관한 연구)

  • 오재유;오의균;강도원;김범진;박태곤
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.251-254
    • /
    • 1998
  • The ($0.8BaTiO_3-0.1SrTiO_3-0.1MgTiO_3$)+$0.006Nb_2O_5$ ceramics were fabricated by conventional ceramic process. The dielectric property of specimen was investigated that the specimen was sintering temperature at 1,300C for 3hours and then annealed at $1,100^{\circ}C$ for 3hours in a atmosphere (air) to be painted on the surface with CuO paste. The results of the temperature and frequency are varied, the dielectric constant and loss tangent are unsuitable for BL capacitor. The dielectric constants were varied to be negative temperature coefficient(2.000-3,000) in the temperature range between -10 and $140^{\circ}C$, the dissipation factors (tan $\delta$) were some high(0.1-0.3). It was not grain insulation, in cause of the some difficult to be annealed temperature with CuO paste and fired atmosphere. But, we have some different annealing temperature and fired atmosphere, it will be suitable BL(Boundary Layer)capacitor.

  • PDF

Visualization of Permittivity Distribution in GFRP using Full-Field Scanning Free Space Measurement System (전영역 스캐닝 자유공간 측정 시스템을 이용한 GFRP의 유전율 분포 가시화)

  • Hyun, Jong-Min;Ahmed, Hasan;Lee, Jung-Ryul
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.99-103
    • /
    • 2018
  • This paper visualizes the full-field permittivity distribution at the standard specimens having known electromagnetic characteristics using a scanning free space measurement (SFSM) system. First, in the two Teflon specimens with different thicknesses, the real and loss tangent of permittivity could be measured and the results agreed to the theoretical and other measurement values. Then the system has been applied to Glass/epoxy and visualized different permittivity distribution depending on the material kind. Therefore, this approach will overcome the point measurement limitation of FSM and can be used for even sub-structural full-field electromagnetic evaluation of stealth and radome structures.

The Dependence of Temperature and Frequency for the Dissipation Factor in Liquid Dielectrics (액체절연체(실리콘유) 유전정접의 온도및 주파수의존성)

  • 이돈희;소병문;이수원;김왕곤;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.85-89
    • /
    • 1993
  • Silicone oil exhibits the properies of both organic and inorganic substances and, thus, it has many superior properties such as higher thermal resistance and lower thermal oxidation level when compared to other dielectric liquids. In order to investigate the dielectric characteristics, dielectric liquids of viscosity 1 [cSt] is chosen as the specimen and experiment is performed in the temperature range of 20∼65 [$^{\circ}C$] and frequency range of 30∼1${\times}$10$\^$6/ [Hz] respectively. As a result, the observed linear decrease in dissipation factor at the frequency range below 3 [kHz] is due to the influence of frequency, whereas the increase in dissipation factor at higher frequency range is contributed by electrode's resistance. At a fixed frequency of 30 [kHz], increasing temperature results in higher peak value and wide width of the absorption curve. This is due to the increase in dipole and viscosity. As temperature increases, dipole moment is decreased from 0.98 to 0.64 [debye]. The activation energy which causes the relaxation and loss of dielectric is obtained about 15 [kcal/mole].

  • PDF

A Study on the Electrical Properties of Electrical Tree Degradation in XLPE Cable Insulation (XLPE 케이블의 전기트리 열화에 따른 전기적 특성 검토)

  • Gang, Dong-Sik;Seon, Jong-Ho;Lee, Hong-Sik;Park, Jeong-Hu;Jo, Jeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.400-405
    • /
    • 2000
  • In order to improve the reliability of XLPE cables, it is necessary to understand the mechanism of electrical and water tree degradation. Especially, electrical tree initiation and propagation are important in XLPE cable insulation. This paper deals with the changes of electrical properties of XLPE cable insulation with electrical tree degradation. To understand the electrical properties of XLPE insulation, specimens were prepared by 22.9kV distribution cable and made in a type of block. Ogura needles having tip radius of 10${\mu}{\textrm}{m}$ were inserted into each block pieces. AC voltages of 8kV, 10kV and 12kV at 60Hz were applied to needle. We investigated the relationship between electrical properties(PD quantity, tan$\delta$ and DC current) and the growth of electrical tree. The electrical properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed.

  • PDF

The On-Line Measuring of Dissipation Factor on pole Transformer (주상 변압기의 절연유 유전정접 활선 측정 기법)

  • Lee, Su-Kil;Kim, Jae-Chul;Yoon, Yong-Han;Lee, Bo-Hoo;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.853-855
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on the operating transformer by using digital signal processing. After applying voltage to the electrodes which is installed In a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques. we can check the dissipation factor of insulating oil. To Improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

On-line Condition Monitoring Technology of Railway Electrification System (도시철도 전기설비 온라인 상태진단 기술)

  • Kim, Do-Yoon;Jung, Ho-Sung;Park, Young;Lee, Sang-Bin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.500-500
    • /
    • 2008
  • 최근들어, 도시철도 전력설비에는 온라인 상태진단이 가능한 센서를 설치하여 각 기기의 상태를 상시 감시하는 시스템이 도입되고 있다. 이러한 기술이 적용됨으로써 전력설비의 교체 주기를 판단하고, 사고를 미연에 방지 하는 등의 최적의 관리를 할 수 있게 되었다. 그러나 운영기관에 따라 다양한 방법의 진단설비가 설치되어 있어 유지보수가 어려워, 도시철도에 적합한 진단시스템의 개발이 요구되어 지고 있다. 도시철도 주요 전기설비로는 변압기, 단로기, 차단기, 정류기 등이 있다. 현재 이를 진단하기 위한 방법으로는 각 장치에 따라 부분방전시험, 유전정접시험, 절연유분석시험, 차단기동작시험 등이 있다. 본 연구에서는 현재 국내 외에서 제시되고 있는 전기설비의 온라인 상태진단 기술을 조사하고, 상용화된 온라인 상태진단 시스템을 분석하여 도시철도 전기설비에 적용 가능한 상태진단 항목과 상태진단 기법을 조사, 분석하였다.

  • PDF

Inprovenent of the Electrical Characteristics of Transformer Oil dissolved with $SF_6 Gas$ ($SF_6 Gas$를 용해시킨 변압기 절연유의 고주파 전기 특성의 향상)

  • Jeon, Chung-Saeng
    • Korean Journal of Materials Research
    • /
    • v.4 no.3
    • /
    • pp.312-318
    • /
    • 1994
  • In this paper the breakdown and dielectric characteristics of purified transformer oil dissolved with $SF_6$ Gas are investigated with a few decade MHz frequency voltage. The results are as follows. 1) High frequency current is a approximately proportional to the square root of high frequency voltage in purified transformer oil. 2) As frequency increase breakdown voltage decrease inversely proportional to the square root of frequency and the high frequency breakdown voltage is lower about 35 percentage than that of AC 3) The breakdown voltage of high frequency has a little increase with the pressure increase of dissolved $SF_6$, Air and Ar Gas. 4) As voltage freguency increases the value of the dielectric loss tangent has increased almost exponentially and the dielectric constant ($\varepsilon$) has tended to decrease with a slope[0.6% MHz]. 5) When dissolved with $SF_6$ Gas, oil electrical characteristics has more increased about 25% than in Air or Ar gas with high voltage frequency.

  • PDF

Sputtering deposition and post-annealing of $Pb(Zr, Ti)O_3$ ferroelectric thin films ($Pb(Zr, Ti)O_3$강유전체 박막의 스퍼터링 증착과 후속열처리)

  • 장지근;박재영;윤진모;임성규;장호정
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.1
    • /
    • pp.36-43
    • /
    • 1997
  • FECAPS(ferroelectric capacitors) have been fabricated by RF magnetron sputtering deposition of 3000$\AA$ PZT thin films on the Pt/Ti/$SiO_2$/Si substrates and post-annealing with the temperature of $550^{\circ}C$~$650^{\circ}C$ for 10 sec~50 sec in a RTA system. The electrical characteristics of the fabricated capacitors showed the highest dielectric constant and remanent polarization[${\varepsilon_r(1kHz)$=690, $2P_r$(-5V~5V sweep)=22$\mu$C/$ \textrm{cm}^2$] in the samples annealed at $650^{\circ}C$ for 30 sec, while the lowest tangent loss and leakage current [$tan\delta(\ge10kHz)\le0.02, \; J_i(5V)=3\mu\textrm{A}/\textrm{cm}^2$]in the samples annealed at $600^{\circ}C$ for 30 sec.

  • PDF

Reliability Assessment of High Voltage Rotating Machine Stator Windings Through Off-line Diagnosis (고압회전기기 고정자권선의 Off-line 진단을 통한 신뢰성 평가)

  • Chang, Jeong-Ho;Lim, Jae-Il;Lee, Dong-Keun;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1628-1629
    • /
    • 2011
  • 산업현장에서는 회전기기의 고체절연시스템(solid insulation system)의 열화정도를 평가하기 위하여 일정 진단주기에 맞춰 Off-line 상태에서 직류시험 및 교류시험을 통하여 효과적으로 절연물에 대한 상태평가를 시행하고 있다. 직류시험으로는 절연저항, 성극지수(PI) 시험 등이 있으며 교류시험으로는 교류전류시험(${\Delta}I$), 유전정접시험(${\Delta}tan{\delta}$), 부분방전(PD)시험이 있다. 여기서 부분방전은 절연체의 국부적인 열화현상을 추정할 수 있는 중요한 파라미터로, 부분방전시험(PD test)을 통하여 고정자권선(stator winding)에 대한 절연특성을 효과적으로 진단할 수 있다. 고압 전동기는 기동정지의 빈번함과 장기간 운전에 의해 열적, 전기적, 기계적 스트레스를 받게 되고, 이로 인해 과열, 진동, 절연파괴에 이르는 문제점이 발생되어 결국 시스템의 운전정지를 초래하는 심각한 사고로 이어질 수 있다. 따라서 고압 전동기의 절연상태를 주기적으로 감시하고 사고 징후를 검출하여 시스템을 안정적으로 운영하기 위한 고압 전동기 Off-line 절연진단에 대하여 기술하고 수차발전기에 대한 절연상태진단 결과를 바탕으로 절연시스템의 신뢰성 평가 방법에 대하여 고찰하고자 한다.

  • PDF