• Title/Summary/Keyword: 유입하수

Search Result 567, Processing Time 0.03 seconds

Evaluation of the impact of sewage treatment plants in the Linked treatment through the sewage treatment computer simulation program (하수처리 전산모사 프로그램을 통한 연계처리시 하수처리장 영향 평가)

  • Kim, Sungji;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.22 no.4
    • /
    • pp.321-327
    • /
    • 2020
  • Recently The amount of wastewater and linked wastewater is being increased every year due to industrial development, population growth, and improvement in living standards. Linked wastewater shows the feature-low flow rate and high concentration. Therefore, it has been shown that it has a great impact on the operation of the sewage treatment plant and costs a lot for treating linked wastewater. In this study, a scenario with low increase of water quality when the total amount of the inflow of linked wastewater was entered into individual reactors is obtained. According to the result of modeling, The effluent water quality get the least increment once the water was introduced into the influent and anoxic tank. We generated the various scenarios Based on these results. scenarios are varying according to inflow from linked waste water's distribution ration. As a result of modeling through various scenarios, it was found that the increment of TN and TP were at the least when the inflow of linked water was distributed with ratio between sewage (80%) and oxygen-free tank (20%).

Effect of sewage flow on treatment efficiency of small scale wastewater treatment plant in rural community (농촌 지역에서 유입 유량이 소규모 하수처리장 처리 효율에 미치는 영향)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.267-274
    • /
    • 2016
  • Sewerage supply in rural community is the important for water quality protection of water system such as river, lake and wetland. And characteristic of small scale wastewater system that have wide range of inflow and concentration in sewage should be considered for stable operation of small scale wastewater treatment plant. In this research, characteristics of flow ratio (flow / designed flow), effect on treatment efficiency of small scale wastewater treatment plant and assessment of optimal flow ratio were conducted through analysis on operation result of 18 small scale wastewater treatment plant in Bong-hwa gun. As a result, flow ratio shows the higher value during summer. However pollutants concentration in sewage was shown the higher concentration during autumn and winter. Treatment of small scale wastewater treatment plant is increased when flow ratio increased, and nutrient treatment efficiency is more sensitive to change of flow ratio than organic compound and suspended solids. According to this research result, it need to be maintained flow ratio 0.8 over value for stable treatment efficiency of small scale wastewater treatment plant.

환경관련 특허동향 - 화장실의 중수도 시스템(해성엔지니어링)

  • 한국환경기술인연합회
    • Environmental engineer
    • /
    • s.328
    • /
    • pp.92-96
    • /
    • 2013
  • 본 발명은 화장실의 세면대에서 사용된 세척수 및 하수를 중수도 수질기준에 적합하도록 처리하여 화장실 용수로 재활용하는 화장실의 중수도 시스템에 관한 것이다. 화장실의 중수도 시스템의 구성을 살펴보면, 세면대에서 사용된 세척수 및 하수가 유입되는 반응조와, 상기 반응조로 유입된 세척수 및 하수를 살균 및 소독하는 마이크로버블 오존 발생장치와, 살균 및 소독된 처리수를 정장하는 처리수조와, 상기 처리수조에 저장된 처리수를 화장실 용수로 공급하는 용수공급펌프를 포함한다. 이 중에서 상기 마이크로버블 오존 발생장치는, 외부에서 유입된 공기를 정화하는 에어필터와, 상기 에어필터에서 정화된 공기를 공급하는 에어펌프와, 상기 에어펌프를 통해 유입된 공기에 자외선을 조사하여 오존을 발생시키는 오존발생기와, 상기 오존발생기에서 발생된 오존을 세척수 및 하수에 혼합시키는 기액혼합펌프와 상기 오존과 상기 세척수 및 상기 하수의 혼합 효과를 극대화하기 위한 라인믹서로 구성된다. 이와 같이 구성된 본 발명에 의한 화장실의 중수도 시스템은 상수(上水)의 소비량을 줄이고 하수(下水)의 발생량을 감소시켜 경비절감의 효과를 얻을 수 있고, 지하수의 고갈 및 생활용수의 증가에 따른 물 부족 현상에 대해 능동적으로 대처할 수 있다. 특히, 재활용된 화장실 용수에는 오존이 함유되어 화장실 내의 악취제거, 살균 및 소독효과가 있으며, 외부로 배출되는 세척수 및 하수에 포함된 유지성분을 제거하여 환경오염을 방지할 수 있다.

  • PDF

Development of Air Flow Calculation System for Sewage Treatment Plant according to Inflow Water Quality (유입수질에 따른 하수처리장 송풍량 산정 시스템 개발)

  • Shin Geol Kim;Wooseok Yeo;Deok-Hyeon Kim;Jong Kyu Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.486-486
    • /
    • 2023
  • 하수처리장 내 생물반응조에서는 유기물을 제거하거나 질산화(Nitrification) 반응을 일으키기 위하여 산소를 요구하고 있으며, 필요한 산소는 송풍기 운영을 통해 공급하고 있는 상황이다. 질산화 반응을 일으키기 위해서 처리장 내 일정 이상의 산소가 수중에 공급되어야 한다. 생물반응조내 용존산소가 부족할 경우 활성슬러지의 침전성이 저해되어 오염물질 저감 효율이 떨어지게 되며, 과도한 산소가 공급되어도 수처리의 효율은 개선되지 않으며 반응에 사용되지 않은 산소들은 대기중으로 방출된다. 또한 유입수질에 따라 실시간으로 반응조 내 필요한 산소는 달라지게 되므로 유입수질에 맞는 효율적인 하수처리장 운영이 요구되고 있다. 하수처리장 내 적절한 산소를 공급하기 위하여 많은 연구들이 활발하게 진행되어 왔으나 실제생물학적 처리시 요구되는 산소의 양을 산정할 수 있는 한계점을 지니고 있으며, 하수 성분, 용량과 같은 환경에 따라 차이를 보이고 있어 범용적으로 사용하기에는 어려움이 있다. 따라서 본 연구에서는 이러한 적용 한계점을 극복하기 위하여 하수도 설계 시 사용되어지고 있는 하수도 시설기준의 산소요구량 및 공기공급량 산정식을 통하여 유입수질에 따라 실제 하수처리장에 필요한 산소요구량 & 공기공급량을 산정하는 시스템을 개발하고자 하였다. 하수도 설계기준의 여러 가지 수식을 실제 하수처리장 내 필요한 요소로 변환시켜 범용적으로 사용가능한 시스템을 개발하였다. 본 연구에서 개발한 하수처리장 송풍량 산정 시스템 적용에 따른 송풍량 절감 효율을 비교분석하기 위하여 2021년 A하수처리장의 4월 월간 데이터를 활용하여 하수처리장에서 필요한 송풍량을 산정하여 실제 사용된 송풍량과 비교 분석하여 송풍량 절감 효율을 분석하였다. 본 연구의 결과를 바탕으로 실제 하수처리장 내 송풍량 산정 시스템을 도입하게 된다면 운전자 경험에 의존하고 있는 수동적인 제어 방식에서 벗어나 자율 제어를 통한 효율적인 하수처리장을 운영할 수 있어 송풍량 절감 및 탄소중립에도 이바지 할 수 있을 것이라고 판단된다.

  • PDF

Wastewater Reuse: Analysis of Water Quality in Paddy (하수재이용에 따른 논에서의 수질 특성 분석)

  • Ko, Jae-Young;Jang, Tae-Il;Park, Seung-Woo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.958-962
    • /
    • 2006
  • 하수처리수를 농업용수로 관개함에 있어서, 관개 유입수 및 논 담수에서의 수질은 작물이나 인체에 미치는 영향이 크다. 따라서 하수재처리수를 농업용수로 사용함에 있어서 수질 기준이 필요하게 되었으며, 이에 환경부에서 $\ulcorner$하수처리 재이용 수질 권고기준$\lrcorner$을 마련하게 되었다. 본 연구에서는 환경부에서 제시한 하수처리 재이용 수질 권고기준에 제시된 수질기준과 본 시험에 사용된 하수처리장 방류수 및 하수재 처리수의 수질을 비교하여 하수처리수의 농업용수 재이용의 적합성을 판단하였으며, 수질 모니터링을 실시하여 논에서의 수질 정화효율을 알아보았다. 본 시험을 위하여 경기도 수원시 하수처리장 인근에 시험포장을 설치하였으며, 하수처리장 방류수와 하수재처리수(여과, 소독, 저류)를 이용하여 논벼 작물 생육시험을 실시하였다. 하수처리장 방류수 수질과 하수재처리수의 수질을 분석한 결과, 수질 기준을 만족하는 것으로 나타났다. 또한, 4년간 실시된 논 유입수 및 담수의 수질 모니터링 결과 논에서의 수질 정화 효율은 TN의 경우 $40{\sim}65%$, TP의 경우 $15{\sim}60%$로 나타났다. 이는 배출수를 통한 하천이나 호소로의 유입에 있어서 환경개선효과를 기대할 수 있을 것이다. 농작업시 인체에 미치는 보건위생정도를 평가하기 위하여 지표미생물의 농도를 분석하였으며, 하수 재이용에 따른 농업용수 활용에 있어 인체에 크게 문제가 되지 않는 것으로 나타났다.

  • PDF

Energy Efficiency Evaluation of Publicly Owned Wastewater Utilities (공공하수처리장의 에너지 소비현황 및 효율성 평가)

  • Cho, Eulsaeng;Han, Dae Ho;Ha, Jongsik
    • Journal of Environmental Policy
    • /
    • v.11 no.4
    • /
    • pp.85-105
    • /
    • 2012
  • In this paper, the energy efficiency of wastewater utilities was evaluated to explore ways to save energy via operational measures. The correlation of each wastewater characteristic parameter to energy was assessed to find a set of parameters that explained most of the variations in energy use among utilities. The results show that increases in inflow, influent COD concentration, and ratio of advanced treatment generally increased the energy use. On the other hand, increases in load factor (influentaverage flow/design flow) reduced the energy use. In the regression analysis, the energy efficiency was highest in the A2O advanced process. On the other hand, the membrane process (among the advanced processes) and the contacted aeration process (among the secondary processes) require more efforts in saving energy. However, the data base system related to energy use must be supplemented in order for more accurate analysis of energy consumption in wastewater treatment facilities. In particular, i) electricity consumption of relay pumps and, ii) energy usage per unit process, iii) pump power usage to discharge treated wastewater in a long distance, if necessary, and iv) alternative energy production and utilization status must be recorded. By utilizing the results of the analysis conducted in this study, it is possible to quantify a level of energy savings needed and establish customized energy saving measures to achieve a certain target level for benchmarking a successful case of wastewater utilities.

  • PDF

Application of CFD model for the design of multi-layer settling basin structure (이층 침전지 설계를 위한 CFD모형의 적용)

  • Yu, Chang-Hwan;Kim, Tae-Won;Kim, Nam-Il;Lee, Kil-Seoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1677-1680
    • /
    • 2006
  • 하수처리장의 침전지 구조물은 고형물(SS) 및 현탁물을 침전, 제거하여 하수의 정화를 도모하는 시설로 초기 유입 하수의 생물학적 처리로 인해 발생되는 슬러지와 처리수를 분리함에 그 목적을 두고 있다. 침전지 구조물은 장소의 제약 및 침전지의 효율성 측면에서 많은 공법이 제안되고 있으며, 그중 이층 침전지의 경우 구조물의 시공비용 절감 및 공간 활용측면에서 단층 침전지에 비해 우수성을 인정받고 있다. 하지만 상 하 층에 위치하고 있는 침전지 유입부의 위치적 특성으로 인해 균등한 유량의 분배가 이루어지지 않고 유량이 한곳에 집중되는 현상으로 보일 수 있다. 본 연구에서는 3차원 수치모형인 FLOW-3D를 이용하여 이층 침전지의 유량분배 최적화를 위한 설계인자를 도출 하였다. 특히 상 하층에 위치하고 있는 유입부의 위치적인 특성을 고려하여 유입부의 직경을 상층 $500mm{\sim}600mm$, 하층 $500mm{\sim}700mm$으로 변화시키며 수치모의를 수행하였으며, 유입량의 분배효과를 확인하기 위해 각 동일한 위치에서 유입량을 산정하였다. 각 케이스별 분배효과를 분석한 결과 상 하층의 유입부 직경을 상층 600mm 와 하층 700mm를 적용했을 경우 유입량의 표준편차가 가장 작게 발생하며, 침전지 내부의 흐름이 원활하게 이루어지는 것으로 확인되었다. 본 연구에서는 상용 CFD모형인 FLOW-3D를 계획 중인 H하수처리장의 이층 침전지 설계에 적용하였으며 유입부 직경에 따른 분배효과를 분석하였다.

  • PDF

A comparative study of micro plastic detection among different pretreatment method (하수처리장 유입수 전처리 방식에 따른 미세플라스틱 검출 비교)

  • Gil, Kyung Ik;Kim, Sung ryul;Lee, Ji Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.422-422
    • /
    • 2021
  • 현대사회에서 플라스틱의 요구량은 꾸준히 증가하고 있으며 이에따라 생산량 역시 맞춰 증가하고 있다. 이에 따라 전세계적으로 플라스틱으로 인해 발생하는 폐기물의 양 역시 증가하고 있으며 이로 인해 플라스틱 재질의 폐기물이 많아지고 있다. 이 중 가장 문제가 되는 폐기물이 바로 미세플라스틱이다. 미세플라스틱은 1㎛ ~ 5mm 미만의 플라스틱으로 그 물리 화학적인 특성으로 인해 회수가 어려우며 외부 환경에 잔류시 독성을 유발할 수 있다. 플라스틱의 약한강도와 열악한 내열성 그리고 유기용매에 취약하다는 단점을 보완하기 위해 첨가하는 화학물질로 인해 내분비계교란물질을 발생시켜 생명체의 내분비계를 교란시켜 최종적으로 성기능장애를 유발한다. 또한 미세플라스틱의 표면은 유기염류성 살충제와 같은 잔류성오염물질(POPs persistent organic pollutants)사이의 흡착성이 크기 때문에 미세플라스틱은 POPs 농도를 주변보다 최대 백만배 높게 만들 수 있다. 미세플라스틱의 분석은 표준화된 방식이 없어서 제각각이지만 대체로 미세플라스틱 표면에 응집된 유기물을 처리하는 전처리, 미세플라스틱의 농도를 분석하는 정량분석, 그리고 미세플라스틱의 성분을 분석하는 정성분석의 과정을 거쳐서 진행된다. 이러한 미세플라스틱의 분석법을 기반으로 하수처리장에 유입되는 하수의 미세플라스틱 분석방법을 제안하면 다음과 같다. 우선 유입수로부터 미세플라스틱을 따로 분리하기 위해 체거름을 진행했다. 이후 유입하수의 성상에 맞는 적정 전처리 방법을 알아내기 위해 유기물을 제거하기 위한 산화방식으롷서 과산화수소수, 80℃의 과산화수소수, 그리고 펜톤산화의 서로 다른 3가지 방식을 사용했다. 이후 이어지는 정량분석과 정성분석결과를 비교하여 유입하수에 가장 최적인 미세플라스틱 측정방법을 알아보고자 한다.

  • PDF

Analytical Evaluation of Influent Depending on the Occurrence of Rainfall by Case Study of Wastewater Treatment Facility (하수처리시설 사례 별 강우발생 유무에 따른 유입수 분석 평가)

  • Choi, Langkyu;Chung, Jin Do
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.35-49
    • /
    • 2019
  • Currently in 2018, Korea has over 600 operating sewage disposal facilities. The law requires a sewage treatment plant to treat 500 tons or more of water per day, and a small-decentralized sewage treatment facility in a community to treat 50 tons or more to less than 500 tons of water per day. However, most facilities fulfill neither the quantity nor the quality requirements from the original design for such reasons as inflow of rainwater and ground water due to deterioration of pipelines and unauthorized input of wastewater in the pipelines. The research has selected 2 representative cases among the technical diagnosif sewage pipelines in many regions within the country to use it as the baseline of: hourly flowrate and BOD water quality analysis in both clear and rainy days, proper plant operation through inflow rate and ratio calculation, and diagnostic evaluation for deterioration of the pipelines and their accessary structures. This also suggests facilities that treats 500 tons or more of inflow per day to sample and analyze the water hourly for 24 hours once a week in both clear weather and rainy weather considering the influence of rainfall on a regular basis.

Installation of Wastewater reuse System for Supply of Agricultural Use (하수처리수의 농업용수 재이용 공급시스템 시범설치)

  • Lee, Kwang-Ya;Kim, Hae-Do;Chung, Kwang-Kun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.662-666
    • /
    • 2007
  • 하수처리수를 농업용 목적으로 재이용하기 위한 기술을 실제 현장에 보급하기 위해 하수처리수가 주 수원공인 양수장에 하수처리수 재처리시스템인 $\ulcorner$농업용수 재이용공급시스템$\lrcorner$을 설치하였다. 본 양수장은 1992년 준공되었으며 양수장 유입구 상류 200m지점에 하수종말처리장 방류구가 위치해 있어 직접적으로 하수처리수가 양수장에 유입되어 농경지에 관개수를 공급하고 있었다. 본 시스템을 설치하기 위해 연간 사용량을 조사하여 적정 처리유량 및 운전시간을 설계하였고 유입수 수질분석을 바탕으로 하수재이용 공급시스템을 설치하여 관개목적에 적합한 수질로 공급할 수 있도록 하였다. 또한 수질 모니터링 시스템을 설치하여 공급 기간 동안 수질변동 상황에 대해 신속한 대처가 가능하도록 시스템을 구성하였다. 현재 농촌지역은 주변상황으로 인해 하수처리수를 관개용수로 이용할 수밖에 없는 지역이 발생하고 있고 앞으로도 하수처리장이 계속 증설되고 있는 한 기존의 농업수리시설물은 하수처리수의 영향이 더욱 커질 것으로 판단되므로 이러한 깨끗한 용수가 위협을 받고 있는 지역에 대해서는 안전한 농산물 생산 도모가 가능한 $\ulcorner$농업용수 재이용 공급시스템$\lrcorner$의 도입이 고려되어야 할 것이다.

  • PDF