• Title/Summary/Keyword: 유용성 기대

Search Result 1,660, Processing Time 0.028 seconds

Preparation of $^{99m}Tc-HYNIC-PEG-liposomes$ for Imaging of the Focal Sites of Infection (농양 진단을 위한 $^{99m}Tc-HYNIC-PEG-liposomes$의 제조)

  • Hong, Jun-Pyo;Awh, Ok-Doo;Kim, Hyun-Suk;Lee, Eun-Sook;Lee, Tae-Sup;Choi, Tae-Hyun;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.333-343
    • /
    • 2002
  • Purpose: A new linker, hydrazino nicotinamide (HYNIC), was recently introduced for labelling of liposome with $^{99m}Tc$. In this study we synthesized HYNIC derivatized PEG (polyethylene glycol)-liposomes radiolabeled with $^{99m}Tc$. Materials and Methods: In order to synthesize HYNIC-DSPE (distearoyl phosphatidyl ethanolamine) which is a crucial component for $^{99m}Tc$ chelation, first of all succinimidyl 6-BOC-hydrazinopyridine-3-carboxylic acid was synthesized from 6-chloronicotinic acid by three sequential reactions. A DSPE derivative of succinimidyl 6-BOC-hydrazinopyridine-3-carboxylic acid was transformed into HYNIC-DSPE by HCI/dioxane. HYNIC-PEG-liposomes were prepared by hydration of the dried lipid mixture of EPC (egg phosphatidyl choline): PEG-DSPE : HYNIC-DSPE:cholesterol (1.85:0.15:0.07:1, molar ratio). The HYNIC-PEG-liposomes were labeled with $^{99m}Tc$ in the presence of $SnCl_2{\cdot}2H_2O$ (a reducing agent) and tricine (a coligand). To investigate the level of in vivo transchelation of $^{99m}Tc$ in the liposomes, the $^{99m}Tc$-HYNiC-PES-liposomes were incubated with a molar excess of DTPA, cysteine or glutathione solutions at $37^{\circ}C$ for 1 hour. The radiolabeled liposomes were also incubated in the presence of human serum at $37^{\circ}C$ for 24 hours. Results: 6-BOC-hydrazinopyridine-3-carboxylic acid was synthesized with 77.3% overall yield. The HYNIC concentration in the PEG-coated liposome dispersion was 1.08 mM. In condition of considering the measured liposomal size of 106 nm, the phospholipid concentration of $77.5\;{\mu}mol/m{\ell}$ and the liposomal particle number of $5.2{\times}10^{14}$ liposomes/ml, it is corresponded to approximate 1,250 nicotinyl hydrazine group per liposome in HYNIC-PEG-liposome. The removal of free $^{99m}Tc$ was not necessary because the labeling efficiency were above 99%. The radiolabeled liposomes maintained 98%, 96% and 99%, respectively, of radioactivity after incubation with transchelators. The radiolabeled liposomes possessed above 90% of the radioactivity in serum. Conclusion: These results suggest that the HYNIC can be synthesized easily and applied in labelling of PEG-liposomes with $^{99m}Tc$.

Estimation and Mapping of Soil Organic Matter using Visible-Near Infrared Spectroscopy (분광학을 이용한 토양 유기물 추정 및 분포도 작성)

  • Choe, Eun-Young;Hong, Suk-Young;Kim, Yi-Hyun;Zhang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.968-974
    • /
    • 2010
  • We assessed the feasibility of discrete wavelet transform (DWT) applied for the spectral processing to enhance the estimation performance quality of soil organic matters using visible-near infrared spectra and mapped their distribution via block Kriging model. Continuum-removal and $1^{st}$ derivative transform as well as Haar and Daubechies DWT were used to enhance spectral variation in terms of soil organic matter contents and those spectra were put into the PLSR (Partial Least Squares Regression) model. Estimation results using raw reflectance and transformed spectra showed similar quality with $R^2$ > 0.6 and RPD> 1.5. These values mean the approximation prediction on soil organic matter contents. The poor performance of estimation using DWT spectra might be caused by coarser approximation of DWT which not enough to express spectral variation based on soil organic matter contents. The distribution maps of soil organic matter were drawn via a spatial information model, Kriging. Organic contents of soil samples made Gaussian distribution centered at around 20 g $kg^{-1}$ and the values in the map were distributed with similar patterns. The estimated organic matter contents had similar distribution to the measured values even though some parts of estimated value map showed slightly higher. If the estimation quality is improved more, estimation model and mapping using spectroscopy may be applied in global soil mapping, soil classification, and remote sensing data analysis as a rapid and cost-effective method.

A study on Analyzing Domestic Cargo Transportation Platform Service Using the IPA Technique (IPA 기법을 활용한 국내 화물 운송중개 플랫폼의 실증분석)

  • Ho-Yeon Yoon;Hyang-Sook Lee
    • Korea Trade Review
    • /
    • v.48 no.1
    • /
    • pp.243-261
    • /
    • 2023
  • This study was conducted with the goal of analyzing the needs of Truckers, who are the main users of the cargo transportation platform, to find a development direction for the improvement and activation of the cargo transportation platform service. For this purpose, this study conducted an empirical analysis through IPA analysis targeting Truckers using domestic cargo transportation platforms. As a result of the IPA analysis, in the case of importance, fair fare presentation, unfair trade prevention measures, transportation payment deadline accuracy, transportation section information provision accuracy, quick interaction, application system quality, ease of use, user-customized service, settlement service support function, Variety of transportation sections, brand image, and additional services were shown in order. In the case of satisfaction, ease of use, settlement service support function, transport section information provision accuracy, application system quality, brand image, additional services, user-customized service, transport section diversity, quick interaction, transport payment deadline accuracy, unfair transaction prevention Measures and fair fares were presented in that order. The analysis results show high satisfaction with the ease of use related to the platform quality and the function to support the settlement work. These results can be seen as the result of a significant investment in system quality improvement for the convenience of users by suppliers in the domestic cargo transportation platform industry, where competition has become fierce. As the factors most urgently needed for improvement, 'observance of payment deadlines', 'prevention of unfair trade', and 'provision of fair fares' were selected, and these are related to chronic problems in the domestic freight transportation industry.

Evaluation of Application Possibility for Floating Marine Pollutants Detection Using Image Enhancement Techniques: A Case Study for Thin Oil Film on the Sea Surface (영상 강화 기법을 통한 부유성 해양오염물질 탐지 기술 적용 가능성 평가: 해수면의 얇은 유막을 대상으로)

  • Soyeong Jang;Yeongbin Park;Jaeyeop Kwon;Sangheon Lee;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1353-1369
    • /
    • 2023
  • In the event of a disaster accident at sea, the scale of damage will vary due to weather effects such as wind, currents, and tidal waves, and it is obligatory to minimize the scale of damage by establishing appropriate control plans through quick on-site identification. In particular, it is difficult to identify pollutants that exist in a thin film at sea surface due to their relatively low viscosity and surface tension among pollutants discharged into the sea. Therefore, this study aims to develop an algorithm to detect suspended pollutants on the sea surface in RGB images using imaging equipment that can be easily used in the field, and to evaluate the performance of the algorithm using input data obtained from actual waters. The developed algorithm uses image enhancement techniques to improve the contrast between the intensity values of pollutants and general sea surfaces, and through histogram analysis, the background threshold is found,suspended solids other than pollutants are removed, and finally pollutants are classified. In this study, a real sea test using substitute materials was performed to evaluate the performance of the developed algorithm, and most of the suspended marine pollutants were detected, but the false detection area occurred in places with strong waves. However, the detection results are about three times better than the detection method using a single threshold in the existing algorithm. Through the results of this R&D, it is expected to be useful for on-site control response activities by detecting suspended marine pollutants that were difficult to identify with the naked eye at existing sites.

Changes in quality characteristics of makjang depending on fermentation location and complex starters (발효 장소와 복합 종균에 따른 막장의 품질 특성 변화)

  • Jieon Park;Myeong-Hui Han;Woosoo Jeong;Soo-Hwan Yeo;So-Young Kim
    • Food Science and Preservation
    • /
    • v.30 no.6
    • /
    • pp.1056-1071
    • /
    • 2023
  • This study aimed to investigate the quality and microbial population changes for 90 days under two fermentation conditions, outdoors and indoors (35℃), with starters (single or mixed) in soybean paste. Bacillus velezensis NY12-2 (S1), Debaryomyces hansenii D5-P5 (S2), Enterococcus faecium N78-11 (S3), and their mixtures (M) were used for the makjang fermentation. The content of amino-type nitrogen among the makjang samples was highly shown in the indoors, followed by M, S3, and S2. The glutamic and aspartic acid contents in the M sample fermented in the indoors showed the highest values of 867.42±77.27 and 243.20±15.79 mg/g, respectively. By the electronic tongue analysis, the M sample fermented in the indoors exhibited lower saltiness and higher umami than the others. Consequently, we expect that using mixed strains, such as Bacillus, Debaryomyces, and Enterococcus, under constant conditions showed potential to the quality improvement of soy products.

Modeling of Sensorineural Hearing Loss for the Evaluation of Digital Hearing Aid Algorithms (디지털 보청기 알고리즘 평가를 위한 감음신경성 난청의 모델링)

  • 김동욱;박영철
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.59-68
    • /
    • 1998
  • Digital hearing aids offer many advantages over conventional analog hearing aids. With the advent of high speed digital signal processing chips, new digital techniques have been introduced to digital hearing aids. In addition, the evaluation of new ideas in hearing aids is necessarily accompanied by intensive subject-based clinical tests which requires much time and cost. In this paper, we present an objective method to evaluate and predict the performance of hearing aid systems without the help of such subject-based tests. In the hearing impairment simulation(HIS) algorithm, a sensorineural hearing impairment medel is established from auditory test data of the impaired subject being simulated. Also, the nonlinear behavior of the loudness recruitment is defined using hearing loss functions generated from the measurements. To transform the natural input sound into the impaired one, a frequency sampling filter is designed. The filter is continuously refreshed with the level-dependent frequency response function provided by the impairment model. To assess the performance, the HIS algorithm was implemented in real-time using a floating-point DSP. Signals processed with the real-time system were presented to normal subjects and their auditory data modified by the system was measured. The sensorineural hearing impairment was simulated and tested. The threshold of hearing and the speech discrimination tests exhibited the efficiency of the system in its use for the hearing impairment simulation. Using the HIS system we evaluated three typical hearing aid algorithms.

  • PDF

Effect of bronchial artery embolization in the management of massive hemoptysis : factors influencing rebleeding (대량객혈 환자에서 기관지 동맥색전술의 효과 : 색전술후 재발의 원인과 예측인자)

  • Kim, Byeong Cheol;Kim, Jeong Mee;Kim, Yeon Soo;Kim, Seong Min;Choi, Wan Young;Lee, Kyeong Sang;Yang, Suck Cheol;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo;Lee, Jung Hee;Kim, Chang Soo;Seo, Heung Suk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.590-599
    • /
    • 1996
  • Background : Bronchial artery embolization has been established as an effective means to control hemoptysis, especially in patients with decreased pulmonary function and those with advanced chronic obstructive pulmonary disease. We evaluated the effect of arterial embolization in immediate control of massive hemoptysis and investigated the clinical and angiographic characteristics and the course of patients with reccurrent hemoptysis after initial succeseful embolization. Another purpose of this study was to find predictive that cause rebleeding after bronchial artery embolization. Method : We reviewed 47 cases that underwent bronchial artery embolization for the management of massive hemoptysis, retrospectively. We analyzed angiographic findings in all cases before bronchial artery embolization and also reviewed the angiographic findings of patients that underwent additional bronchial artery embolization for the control of reccurrent hemoptysis to find the clauses of rebleeding. Results : 1) Underlying causes of hemoptysis were pulmonary tuberculosis(n=35), bronchiectasis(n=5), aspergilloma(n=2), lung cancer(n=2), pulmonary A-V malformation(n=1), and unknown cases(n=2). 2) Overal immediate success rate was 94%(n=44), an6 recurrence rate was 40%(n=19). 3) The prognostic factors such as bilaterality, systemic-pulmonary artery shunt, multiple feeding arteries and degree of neovascularity were not statistically correlated with rebleeding tendency (p value>0.05). 4) At additional bronchial artery embolization, Revealed recannalization of previous embolized arteries were 14/18cases(78%) and the presence of new deeding arteries was 8/18cases(44%). 5) The complications(31cases, 66%) such as fever, chest pain, cough, voiding difficulty, paralytic ileus, motor and sensory change of lower extremity, atelectasis and splenic infarction were occured. Conclusion : Recannalization of previous embolized arteries is the major cause of recurrence after bronchial artery embolization. Despite high recurrence rate of hemoptysis, bronchial artery embolization for management of massive hemoptysis is a effective and saute procedure in immediate bleeding control.

  • PDF

Evaluation of the combination of Bone Scan Image and Pelvic X-ray Image (뼈 검사 영상과 골반 X선 영상의 결합 유용성 평가)

  • Lee, Choong Woon;You, Yeon Wook;Kim, Yong Keun;Weon, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.23-27
    • /
    • 2018
  • Purpose The introduction of bone scan has been reported as a useful tool in the diagnosis, treatment, and treatment response of skeletal disease. The purpose of this study is to improve the anatomical information and tolerance of the bone by combining bone scan and pelvic X-ray without additional radiation exposure. Materials and Methods From November 2015 to August 2016, 236 patients(64 men and 172 women, average age $50.96{\pm}15.39years$) take Bone scan and Pelvis AP(Anteroposterior) X-ray scan at the National Cancer Center. The scan equipment was a gamma camera, Symbia Ecam (SIEMENS, Germany), and a digital x-ray, DRS-800 (Listem, Korea). Osirix version 3.8.1 (Osirix, USA) and Stata/SE version 14.0 (StataCorp, USA) were used for image combination and analysis. The patient was intravenously injected with $^{99m}Tc-DPD$ (740 MBq), and the scan was performed 2 to 4 hours later. Gamma camera image acquisition were Matrix size $256{\times}1024$, Zoom 1.00, and scan speed 17 cm/min. The digital X-ray was made with a collimator size of $14^{{\prime}{\prime}}{\times}17^{{\prime}{\prime}}$, 77 kVp (60 to 97 kVp) and an average of 30 mAs (20 to 48). ASIS and pubic symphysis Select virtual points then Combine three virtual points and pelvic contour lines. The acquired images were evaluated by three radiologists who worked for more than 5 years in the nuclear medicine department. Results Of the total 236 patients, 216 (91.53%) were matched. The median and range (min~max) of the age were 67 (46~81) years old in the unmatched group and 52 (22~87) years old in the matched group, The Wilcoxon rank-sum test was performed to determine whether age was different between the two groups. As a result, the age difference between the two groups was statistically significant at p < 0.0001. Of the 64 men, 60 (93.75%) were match and of the 172 women, 156 (93.75%) were match. There was no statistically significant difference according to gender(p = 0.4542). Of the 54 patients without pelvic lesions, 54 (100.00%) were match, and 162 (89.01%) of 182 patients with pelvic lesions were match. There was a statistically significant difference according to the presence of pelvic lesions. Conclusion There are many variables in the combination of bone scan and pelvic X-ray imaging, and the patient's age and pelvic lesion may have some effect on the image combination. This study is expected to be useful for the diagnosis of pelvic osteosarcoma of children without radiation exposure. It is expected that this combination of images will help to develop the nuclear medicine image.

The Usability Evaluation of the Usefulness of Bismuth Shields in PET/CT Examination (PET/CT 검사에서 비스무스(bismuth) 차폐체의 적용에 따른 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon;Nam, Kun-Sik;Lyu, Kwang-Yeul;Lee, Tae Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2014
  • Recently with CT developed, various studies for reduction of exposure dose is underway. Study of bismuth shields in these studies is actively underway, and has already been applied in the clinical. However, the application of the PET/CT examination was not activated. Therefore, through this study, depending on the application of bismuth shields in the PET/CT examination, we identify the quality of the image and the impact on the Standard Uptake Value (SUV). In this study, to apply to the shielding of the breast, by using the bismuth shields that contains 0.06 mm Pb ingredients, was applied to the PET/CT GEMINI TF 64 (Philips Healthcare, Cleveland, USA). Phantom experiments using the NEMA IEC Body Phantom, images were acquired according to the presence or absence of bismuth shields apply. Also, When applying, images were obtained by varying the spacing 0, 1, 2 cm each image set to the interest range in the depth of the phantom by using EBW-NM ver.1.0. When image of the PET Emission acquires, the SUV was in increased depending on the use of bismuth shields, difference in the depth to the surface from deep in the phantom increasingly SUV increased (P<0.005). Also, when using shields, as the more gab decreased, SUV is more increased (P<0.005). Through this study, PET/CT examination by using of bismuth shields which is used as purpose of reduction dose. When using shields, the difference of SUV resulting from the application of bismuth shields exist and that difference when gab is decrease and surface is wider. Therefore, setting spacing of shield should be considered, if considering the reduction of the variation of SUV and image quality, disease of deep organs should be a priority rather than superficial organ disease. Use of bismuth shielding factor considering the standard clinical examination, decrease unnecessary exposure can be expected to be considered.

Comparison of Mitral Valve Repair between a Minimally Invasive Approach and a Conventional Sternotomy Approach (승모판 성형술에 있어 최초 침습적 수술방식과 고전적 정중 흉골 절개술을 통한 접근방식의 비교)

  • Cho, Won-Chul;Je, Hyoung-Gon;Kim, Jeong-Won;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.12
    • /
    • pp.825-830
    • /
    • 2007
  • Background: Minimally invasive cardiac surgery appears to offer certain advantages such as earlier postoperative recovery and a greater cosmetic effect than that achieved through conventional sternotomy. However, this approach has not yet been widely adopted in Korea to replace complex open heart surgery such as mitral valve reconstruction. This study compared the results of robot assisted minimally invasive mitral valve repair with those results of conventional sternotomy. Material and Method: From December 1993 to December 2005, 520 consecutive patients underwent mitral valve reconstruction for mitral regurgitation in our institution. These patients were subdivided according to those whose surgery used the conventional sternotomy approach (Group S, n=432) and those who underwent minimally invasive right anterior thoracotomy (Group M, n=88); we then compared the clinical results of both groups. When we performed minimally invasive right thoracotomy, we used a robot (AESOP 3000) and made an incision less than 5 cm. Result: Our study patients in both groups were similar for their age, gender and preoperative ejection fraction. There were two hospital mortalities in group S. but there was no mortality in the group M patients. Significant reductions in the ICU stay and the postoperative hospital stay were observed in the group M patients compared with the group S patients. However, both the bypass time and the aortic cross-clamp time were significantly longer in the group M patients. In spite of the confined incision in the group M patients, there were no limitations on the mitral valve repair techniques. There was a similar frequency of postoperative significant residual mitral regurgitation in both groups. Conclusion: In this study, the minimally invasive mitral valve repair showed comparable early results with the conventional sternotomy patients. We will now need long-term follow-up of these patients who underwent minimally invasive mitral valve repair, but we anticipate that based on the results of this study, we will begin to routinely perform minimally invasive cardiac surgery as out primary approach for mitral valve reconstruction.