• Title/Summary/Keyword: 유압 제어 시스템

Search Result 412, Processing Time 0.035 seconds

Hybrid control of the swash plate-type variable displacement hydraulic piston pump for an EHA (EHA용 가변용적형 사판식 유압 피스톤 펌프의 하이브리드 제어)

  • Kwon, Yong-Cheol;Hong, Yeh-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.4
    • /
    • pp.291-298
    • /
    • 2013
  • In this paper a new hybrid-type control system is proposed which reduces the pump speed of an electro-hydraulic actuator consisting of a pressure-compensated variable displacement piston pump and a valve-controlled hydraulic cylinder, whenever the flow rate demand is low. In order to avoid interfering with the pressure regulator which also has an effect on swash plate angle, the pump speed is changed in proportion to the mean value of the speed component of position commands. Additionally a pressure switch is employed to prevent the system pressure from getting lower than a reference value. Based on computer simulation & experimental results, it is shown that the hybrid control can save the idling power up to 44% at a stand-by mode by reducing the pump speed from 1,800 rpm to 600 rpm without affecting the dynamic response of the electro-hydraulic actuator.

Trajectory Tracking Control of Injection Molding Cylinder Driven by Speed Controlled Hydraulic Pump (속도제어-유압펌프에 의하여 구동되는 사출성형 실린더의 궤적추적제어)

  • Cho, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.2
    • /
    • pp.21-27
    • /
    • 2007
  • This paper deals with the issue of trajectory tracking control of a clamping cylinder for injection moulding machine, which is directly driven by speed controlled hydraulic pump in combination with AC servomotor. As a fundamental step prior to tracking controller design, feedback control system is developed by implementing a position control loop parallel with a system pressure control loop. A sliding mode controller combining velocity feedforward scheme is developed for enhancing the tracking performance. Consequently a significant reduction in tracking error is achieved for both position and pressure control applications.

  • PDF

Modeling of hydro turbine-governor for simulation (수력 터빈-조속기 시뮬레이션을 위한 모델 구현)

  • 정창기
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.52-55
    • /
    • 1999
  • 디지털 시스템의 발전으로 발전소의 제어시스템도 디지털시스템으로 설비개체가 많이 시행되고 있다. 발전소 제어설비중에서도 아직 연구개발이 미진하고 상대적으로 낙후된 터빈 조속기 제어 분야는 최근 몇 년전부터 연구개발이 진행중이다. 본 논문에서는 수력발전소 수차제어시스템을 개발하기 위한 기본 단계로 수력 터빈-조속기 모델과 기계유압식 조속기의 모델을 검토해 보고 디지털 제어시스템으로 개조하기 위한 디지털 PID 모델을 제시하였다.

  • PDF

Fault Diagnosis for High Pressure Turbine Valve using Fuzzy Logic (퍼지 논리를 이용한 원자력 발전소 고압터빈 밸브 고장진단)

  • Kim Yeon-Tae;Jeong Byeong-Uk;Baek Gyeong-Dong;Kim Seong-Sin
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2006.05a
    • /
    • pp.79-82
    • /
    • 2006
  • 본 논문은 원자력 발전소의 주요 제어계통 중에서 터빈 조속기 제어계통에 관련한 성능평가를 목적으로 한다. 터빈 조속기 계통은 고압의 유압계통으로 구성되어 있어 구동설비가 복잡하다. 복잡한 기계설비는 운전 중 많은 오동작에 의한 고장을 일으키고, 유지보수에 어려움이 있다. 이러한 복잡한 기계설비에 있어 운전원에 의한 기계성능 평가는 불리한 점이 많다. 예를 들어 서로 다른 시간에서 일어나는 같은 상황에 대해 다른 판단을 내릴 수 있다는 점이다. 터빈 조속기 계통의 기계설비에 있어서 터빈 밸브 유압공급 및 구동장치는 각 터빈벨브 자체에 부착되어 있어 터빈벨브를 동작시킨다. 터빈벨브들은 구동기 유압 서보실린더(Actuator Hydraulic Servo Cylinder)에 의해 열리고 압축된 스프링에 의해 닫힌다. 이러한 시스템을 진단하기 위해서 본 논문에서는 밸브의 내부 압력의 특징정보를 입력으로 하는 퍼지이론을 적용하여 터빈 밸브 구동설비의 성능을 판단하고자 한다. 퍼지이론에 적용하기위해 터빈 조속기 제어계통의 고압 터빈 조절 벨브와 고압 터빈 정지 밸브의 압력변화 데이터를 이용한다. 퍼지이론의 적용과정에서 퍼지 Rule은 실제 운전원이 압력변화 데이터에 대한 판단기준을 근거로 하여 정하기로 한다. 그리고 퍼지이론에 적용한 결과를 분석하고 실제 터빈 조속기 계통의 전문가가 판단 결과와 비교하였다.

  • PDF

Start and Stop Characteristics of Single-Rod Electro-Hydrostatic Actuator (전동기 일체형 편로드 유압액추에이터의 기동 및 정지특성해석)

  • Jung, Gyu-Hong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1483-1490
    • /
    • 2011
  • Electro-hydrostatic actuators(EHAs), which are usually composed of a direct motor-driven hydraulic pump and a cylinder, have been widely adopted as aircraft actuation systems because of their benefits in terms of improved efficiency, weight savings and the fact that they use a standalone power source. Since the recent trend in construction vehicles has been focus on energy savings in their hydraulic systems, EHAs are expected to be potential substitutes for conventional power transmission, since they are capable of energy recovery as well as highly efficient pump control. In this paper, the start and stop characteristics of EHAs were investigated through cracking pressure analysis of the pilot-operated check valve(PCV), which enables the cylinder to standstill against an external load with no holding effort from the hydraulic pump. A mathematical model that includes the load dynamics and the EHA's internal hydraulic circuit was derived for simulation with the MATLAB Simulink package. This model verified the PCV's opening and closing sequence, which in turn affects the EHA's start and stop characteristics.

A study on the pressure controller design of multiple control valve structure (다중 제어밸브 구조의 압력제어기 설계에 관한 연구)

  • Shin, Suk-Shin;Park, Jong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.404-408
    • /
    • 2013
  • In this Study, another way to accomplish the goal of meeting large steam-flow requirements is the use of multiple valves. Multiple valves can provide better control in meeting the precision pressure controller requirements. Simulation demonstrates the effectiveness of the pressure controller. The key point of this study is to precisely control the position of the control valve on the outside of the electro-hydraulic system using a special PID controller. Simulation and experiments verify the performance of the controller.

A Study of Hybrid Power System for Construction Machine (건설기계용 하이브리드 동력 시스템에 관한 연구)

  • Kim, Chong-Chul;Huh, Sung-Jae;Cho, Yu-Hwan;Lee, Byeong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1136-1137
    • /
    • 2007
  • 현재 건설기계에 있어서 연비 절감에 대하여 유압 기기나 엔진의 에너지 손실 저감에 대한 대책이 있었으나 이것만으로는 한계가 있어 대폭적인 방안을 모색하는데 있어서 동력 시스템의 재검토가 필요한 시점이다. 더불어 자동차와 마찬가지로 건설기계에서도 배기가스 저감이나 연비 저감은 매우 중요한 과제이다. 그 해결책으로서 현재 자동차에서 개발된 하이브리드 시스템의 적용이 매우 유용하다 할 수 있다. 따라서 본 논문에서는 하이브리드 동력 시스템을 건설기계에 적용한 내용을 소개하고 있다. 건설기계의 하이브리드 동력 시스템을 구성하는 엔진, 발전기, 모터, 배터리, 커패시터 등의 전력전자 기기와 전동 유압을 구성하는 전동 유압 기기를 모델화 하여 하이브리드 동력 시스템을 적용한 건설기계의 기본적인 구조와 제어 성능을 파악하고 방식별 하이브리드 시스템의 성능을 비교하였다.

  • PDF

Active Control of Structural Vibration Using an Instantaneous Control Algorithm Including Acceleration (가속도가 포함된 순간최적제어 알고리듬을 이용한 구조물 진동의 능동제어)

  • 문석준;정태영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.254-260
    • /
    • 1995
  • 본 연구에서는 제어 알고리듬 적용면에서 가속도 계측이 보다 용이한 점을 고려하여 가속도가 포함된 가속도-속도-변위 되먹임 제어 알고리듬을 개발하고, 이를 유압식 능동 질량구동장치에 적용하여 능동제어시스템의 성능을 실증적으로 검토한다. 이 때 능동제어시스템의 구성요소들의 동특성을 시스템 모델링에 포함하여 제어력을 산정함으로써 시간 지연의 영향을 효과적으로 보상하는 방안을 제시한다.

  • PDF

Comparison of Control Performance in Electro.hydraulic Servo Systems (전기.유압 서보 시스템의 제어성능 비교)

  • Kim, D.T.;Park, K.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.2
    • /
    • pp.14-20
    • /
    • 2006
  • A controller design procedure for an electro-hydraulic positioning systems has been developed using $H{\infty}$ control. The generalized plant models and weighting function for multiplicative uncertainty modelling error was presented along with $H{\infty}$ controller designs in order to investigate the robust stability and performance. Both disturbance rejection and command tracking performances were improved with the $H{\infty}$ controller, and the better uniformity of time response is achieved across wide range of operating conditions than the PID, LQR and LQG control scheme. The multiplicative uncertainty case was specifically suited for the design of an electro-hydraulic positioning control systems using $H{\infty}$ control.

  • PDF