• Title/Summary/Keyword: 유속제어

Search Result 196, Processing Time 0.023 seconds

Study on Ventilation Efficiency of A Naturally Ventilated Broiler House-( I ) Summer Season (자연환기식 육계사내의 환기효율성 조사연구-( I )하절기)

  • 이인복;유병기;정문성;윤진하;전종길;김경원;성시흥
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • Most of broiler houses in Korea have the trouble of environmental control such as suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens. Accordingly, it is very urgent to develop optimum designs of naturally and mechanically ventilated broiler houses for Korean climate. In this study, the internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were measured at a naturally ventilated broiler house. The data were collected during summer season including local weather data. It was found that the difference between measured and optimum air temperatures was $14.0^{\circ}C$ in maximum during the summer time. The daily maximum range of internal averaged air temperature was found $10.5^{\circ}C$ while the uniformity was $5.2^{\circ}C$ in maximum. The maximum, average, and minimum internal averaged relative humidity were 89.3%, 73.7%, and 49.2%, respectively while locally measured were 95.1% and 47.2%, respectively in maximum and minimum. Considering Temperature-humidity index, during summer season, over 97% of totally rearing period was shown that counter plan is needed for thermal stress while it was very dangerous situation for 22% of the rearing period. The ammonia gas and dust concentrations were seriously affected by the broilers activity, growth level, and relative humidity.

  • PDF

Performance Analysis for Turbo Blower According to Inlet-Vane Angles (입구베인 각도에 따른 터보블로어 성능특성 연구)

  • Jang, Choon-Man;Lim, Soo-Jung;Yang, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.301-307
    • /
    • 2011
  • Turbo blowers are mainly used in refuse collection systems. We discuss blower performance in relation to the angle of the inlet vane installed at the upstream of the blower. The flow characteristics of the components are analyzed by three-dimensional Navier-Stokes analysis and compared to experimental results. A two-stage serially connected turbo blower is introduced to analyze the performance experimentally. Throughout the experimental measurements and the numerical simulation, the distorted inlet velocity generated in the small vane angle reduces the performance of the blower, because of the local leading-edge separation and the resulting non-uniform blade loading. We also perform a detailed flow analysis using the results obtained in the numerical simulation.

Development of Chromatographic Downstream Processing for The Purification of Monoclonal Antibody from Ascites Fluid: Part 1. Tandem Use of Hydroxylapatite Chromatography and Gel Permeation Chromatography (복수로부터의 단세포군 항체의 정제를 위한 크로마토그래프 분리 정제 시스템의 개발 - 1. 히드록실 아파타이트 크로마토그라프와 겔 여과 크로마토그라프로 이루어진 2단계 연속공정 사용 -)

  • Ahn, I.S.;Park, C.Y.
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.1
    • /
    • pp.19-23
    • /
    • 1989
  • A sequential system composed of hydroxylapatite chromatography and gel permeation chromatography was developed to purify the IgM type monoclonal antibody against the colon cancer cell SC-1 from the ascitic fluid of mice injected with the murine hybridoma CH07E02. In the hydroxylapatite chromatographic step the band dilution could be reduced by controlling the gradient and flow rate of the eluent, the sodium phospate buffer, the optimum values for these variables being 5.82$\times$10$^{-3}$M/cm and 0.2$m\ell/\textrm{cm}^2$/min, respectively. A degree of purity better than 99.99% as judged from silverstaining of the SDS-PAGE bands, was obtained by adding the gel permeation chromatographic step in tandem.

  • PDF

An Experimental Study on Flow control around Foil with Coanda effect (콴다효과를 이용한 익 주위의 유동제어에 관한 실험적 연구)

  • Oh, Kyoung-Gun;Cho, Dae-Hwan;Lee, Gyoung-Woo;Ko, Jae-Yong
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.65-69
    • /
    • 2006
  • The flow around a foil with water jet was investigated using the two-frame PIV(CACTUS 3.1) system. After separation, unsteady recirculation & reattachment region was shown a result at reading edge. Separation area was decreased to 1/3 more by waterjet system with coanda effect. Angle of attack and water jet velocity was a variable in the experiment. Each parameters was controlled to $0^{\circ}\sim35^{\circ}$ and $0[m/s]\sim9.2[m/s]$. The separation of flow appearanced at first when the angle of attack is $17^{\circ}\sim18^{\circ}$, However, according to grew up of velocity, beginning of the separation was delayed. In this experiment, vortex and separation region was disappeared by blown when each parameters are low level, and separation controlled more certainly.

  • PDF

An On-Line Measurement of Ethanol Concentration by Membrane Gas Sensor (막가스센서에 의한 에탄올 농도의 온라인 측정)

  • 김형찬;박민선
    • KSBB Journal
    • /
    • v.10 no.2
    • /
    • pp.126-130
    • /
    • 1995
  • A membrane gas sensor was developed for the measurement of ethanol concentration during acetic acid fermentation. The fermentation broth including ethanol was permeated through the silicone membrane by synthetic air as a carrier gas and was detected by a semiconductor gas sensor. The optimum conditions of membrane gas sensor were 20m1/min of flow rate and 0.5mm of membrane thickness. In acetic acid fermentation, an on-line measurement of ethanol concentration was conducted by the proposed membrane gas sensor and then the on-line sensor signal, was compared with the result of off-line analysis by gas chromatography. As a result, a correlated response over the range of $0∼70g/\ell$ was shown between membrane gas sensor and gas chromatography and this use of membrane gas sensor was experimentally ascertained for the monitoring and control of bioprocess like acetic acid fermentation.

  • PDF

Analysis of Flame Shape in Flare Stack (플레어스택의 화염 형상 분석)

  • Lee, Heon-Seok;Kim, Bum-Su;Jung, Sang-Yong;Yoo, Jin-Hwan;Park, Chul-Hwan;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.49-53
    • /
    • 2009
  • Relief systems can improve the process safety because it has the function for the prevention of overpressure. Flare stacks is necessary to avoid explosion, radiation, or toxicity by waste-gas emitted from relief system. Safe combustion is one of the important factors to improve safety and the quantity and velocity emitted is ruled in the API code 521. Due to the pressure of released gas and mass flow, a flame from flare stack is similar to jet fire. In this study, we have investigated the effect of flame form on complete combustion and heat emission. API code was similar to jet fire model in flame length, the flame had an effect on the ground.

  • PDF

Cavitation Visualization Test for Shape Optimization of Bottom Plug in Reversing Valve (공동현상 가시화 실험을 통한 절환밸브 바텀플러그 형상 최적화)

  • Kim, Tae An;Lee, Myeong Gon;Han, Seung Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.913-918
    • /
    • 2016
  • A three-way reversing valve, which provides rapid and accurate changes in the water flow direction without requiring any precise control device, is used in automotive washing machines to remove oil and dirt that remain on the machined engine and transmission blocks. Because of the complicated shape of the bottom-plug, however, cavitation occurs in the plug. In this study, the cavitation index and POC (percent of cavitation) were used to quantitatively evaluate the cavitation effect occurring in the bottom-plug on the downstream side. An optimal shape design was conducted via parametric study with a simple CAE model to avoid time-consuming CFD analysis and hard-to-achieve convergence. To verify the results of the numerical analysis, a flow visualization test was conducted using a specimen prepared according to ISA-RP75.23. In this test, the flow characteristics, such as cavitation occurring on the downstream side, were investigated using flow test equipment that included a valve, pump, flow control system, and high-speed camera.

An Experimental Study of Aerodynamic Characteristics on a Projectile with Counter-Rotating Head Installed Fins (조종면이 장착된 회전하는 발사체에서의 공력특성 분석에 관한 실험적 연구)

  • Park, Young-Ha;Je, Sang-Eon;Cho, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.5
    • /
    • pp.357-365
    • /
    • 2013
  • In this study, forces and moments were measured on a projectile which consisted of a missile configuration body(shell) and a head installed control fins. The shell and the head were separated each other and the shell was rotated by an electric motor. The head rotated reversely against the rotational direction of the shell. The rotational force on the head was obtained from a couple of fixed fins of which angular displacement were set to the rotational direction equally. The air velocity was 40m/s on the experiment and the Reynolds number based on the diameter of head was $1.3{\times}10^5$. The other couple of fins were used to control the position and direction of the projectile by changing the angular displacement. From this experiment, the variation of force and moment were measured on the rotating projectile, and the effective amplitude and frequency were obtained through the FFT analysis.

Current Characteristics of a Flow Injection Type Enzyme-Sensor as the Variables of a Buffer Velocity, an Enzyme-Substrate Reaction and an Electrode for the Control of a Fermentation Process (완충용액유속, 효소.기질 반응 및 전극봉 요인에 따른 발효공정 제어용 흐름주입식 효소센서의 전류값 특성)

  • Song, Dae-Bin;Jung, Hyo-Seok;Kim, Sung-Tae
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.455-461
    • /
    • 2007
  • The electric current of a flow injection type enzyme-sensor was measured to confirm the stable operating conditions of the sensor. The current of the sensor was decreased as the buffer solution velocity increased. Under the limitation of the cycle time to be below 10 minutes, the effective ranges of the buffer solution velocity were suggested $0.10{\sim}0.26$, $0.12{\sim}0.24$, $0.1{\sim}0.25$ and $0.05{\sim}0.10\;cm/s$ of 1.0, 1.4, 2.4 and 3.4 mm of the electrode diameters, respectively. As the reaction time of the enzyme and the substrate was increased, the current was decreased because of the dilution between the sample and buffer solution. Therefore, it could be recommended that the reaction time was able to be selected as shortly as possible in consideration of the total cycle time. As the result of the experiments using a different volume ratio of the enzyme to substrate, it was concluded that the substrate had to be mixed with the same amount of the enzyme. The current have increased remarkably in proportion to the electrode diameter under 0.1 cm/s of the buffer solution velocity but there was no difference over 0.1 cm/s of the buffer solution velocity. The cross type arrangement of the electrode was highly suggested for application and machining of the sensor.

Numerical Study for Flow Uniformity in Selective Catalytic Reduction (SCR) (SCR 반응기 유동 균일화를 위한 수치적 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Lee, Gang-Woo;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.151-154
    • /
    • 2011
  • $NO_x$ 제어 기술로는 크게 연소 전 탈질, 연소 개선 및 연소 후 탈질 기술로 구분할 수 있으며, 연소 후 탈질 기술에 속하는 SCR은 촉매를 사용하여 $NO_x$를 환원하는 대표적인 배연탈질기술이다. SCR의 $NO_x$ 저감 성능은 촉매 요인(촉매 구성물질, 형태, 공간속도 등)과 배가스의 온도, 유속 분포, 공정 운전 조건 등의 다양한 인자에 의해 좌우되는데 특히, 촉매층으로 유입되는 유동의 균일도는 가장 중요한 요소가 된다. 유동이 균일하지 않을 경우 촉매 전단에 편류가 발생하게 될 것이며 일정 촉매만 사용하게 되어 촉매 사용주기 감소 및 SCR 성능 저하를 초래할 수 있기 때문이다. 본 연구에서는 3차원 수치 해석 기법을 이용하여 설계 초기의 SCR 반응기 내 유동 특성을 모사하여 기류 균일도 여부를 확인하고, SCR 내 유동 균일도를 최적화시키기 위한 설계를 목적으로 설치하는 가이드 베인과 배플, 다공판이 반응기 내부 유동 및 촉매층의 기류 균일도에 미치는 영향에 대하여 연구를 수행하였다. 그 결과, 유동 개선을 위해 인입 덕트 곡관부에 가이드 베인을 설치하여 처리가스를 적절하게 배분시키고, 반응기 상단에 3단 배플을 설치한 결과 반응기 내부 유동의 편류 개선에 매우 효과적임을 알 수 있었다. 또한 다공판을 예비 촉매층 하단부 위치에 추가로 설치함에 따라 유동을 한번 더 완충시킬 수 있어 기류 균일도가 매우 양호해짐을 알 수 있었다.

  • PDF