The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography (디지털 유방확대촬영술에서 노출방식에 따른 피폭선량 평가)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.293-298
    • /
    • 2012
  • In digital mammography, Exposure factor were automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a increase glandular dose. The purpose of this study was to investigate optimal image quality in digital magnification mammography to decrease radiation exposure of patient dose. Auto mode gives the best image quality however, AGD showed better image quality. Image quality of manual mode passed phantom test and SNR at 55% mAs of auto mode commonly used in the digital magnification mammography. Also it could reduce AGD. According to result, manual mode may reduce the unnecessary radiation exposure in digital magnification mammography.

Evaluation of the Usefulness for Air Gap Technique in Digital Magnification Mammography (디지털 유방확대촬영술에서 Air gap technique의 유용성 평가)

  • Kim, Mi-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.101-107
    • /
    • 2014
  • The purpose of this study was investigated optimal exposure condition in digital magnification mammography to decrease radiation dose and increase image quality of the examinee. Auto mode, the average glandular dose is higher than the manual mode. Average glandular dose and image quality were many differences on between grid and air gap technique in auto mode. However, Average glandular dose and signal-to-noise ratio were not different on between grid and air gap technique in manual mode. The signal-to-noise ratio was increased when using the air-gap technique in both mode. According to result, air gap technique may reduce average glandular dose and increase signal-to-noise ratio in digital magnification mammography.

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

Evaluation of Usefulness of Image by Using New Compression Paddle for Mammoplasty Patient During Mammography (유방촬영 시 유방보형물 환자에 대한 새로운 압박대 적용의 유용성 평가)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.229-235
    • /
    • 2015
  • Mammoplasty is currently increasing not only for cosmetic surgery, but as well as for the recovery after breast cancer surgery. The prostheses inserted into the breasts of women who have undergone mammoplasty, hide the breast substances and it is becoming increasingly difficult to diagnose breast disease, and fear is growing by the concern of the prostheses bursting by the strap. So we want to develop a strap applicable to women with prostheses inserted, to determine the usefulness, and we also want to compare the utility by comparing the total area of the Inner and Outer parts of the breast and Posterior Nipple Line (PNL), after obtaining video by applying the existing strap and the developed strap to phantom of the prostheses inserted patient shape. When the pressure by the developed pressure, the total area increased by 10.09% from CC view to $9,813.797mm^2$, 3.88% from CC-ID view to $7,621.531mm^2$, PNL increased by 3.41% from CC view to $90.916mm^2$, 1.64% from CC-ID view to$75.357mm^2$. And the breast tissue of the thorax side increased 3.53% from CC view to $177.725mm^2$, and 6.57% from CC-ID view to $152.510mm^2$, and we could verify that the prostheses were completely eliminated in the CC-ID images of developed strap, compared with the existing strap.

Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography (디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화)

  • Kwon, Soon Mu;Kim, Boo Soon;Park, Hyung Jun;Kang, Yeong Han
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.535-540
    • /
    • 2015
  • Collimator has important functions with control primary X-ray that decrease radiation exposure dose for patients and reduce scatter ray and make better quality of image. But there are no regulations for X-ray mammography device of collimator, so widely used device adopt rectangularly controlled collimator. Though digital X-ray mammography device expand supply recently, rectangularly controlled collimator of film/screen mode still used. After searching for real condition of beam field with digital mammography, we made a multi-leaf collimator which is able to adjust the beam field in accordance with size and shape of breast, and we measuring up the transitions of image quality, average glandular dose(AGD) and, Dose area product(DAP). There are no significant differences between rectangularly controlled collimator and multi-leaf collimator, and DAP value decreased by 50.72%. As conclusion, there needs to expand the use of multi-leaf collimator for optimum adoption of beam field in digital mammography, and also need to develop an automatic regulation of beam field for reduce of exposure dose to patients.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

Cancer Health Literacy and Cancer Screening Behaviors: A Systematic Review (암 건강정보문해력과 암 조기진단행위: 체계적 문헌고찰)

  • Guo, Lingru;Kim, Hyunli
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.9
    • /
    • pp.373-385
    • /
    • 2021
  • The purpose of this paper is to systematically evaluate the relationship between cancer health literacy and cancer screening behaviors using global data. Following the preferred reporting items for systematic reviews and meta-analyses review guidelines, full-text articles published on PubMed, CINAHL, Embase, and Cochrane Library were reviewed until 31 January 2021. The reference lists of all selected studies have been also included. The cancer health literacy and cancer-screening behaviors of the participants aged ≥18 years were assessed. Seventeen studies that met the inclusion criteria were included. The cancer screening behaviors included mammograms, clinical breast cancer examination, Papanicolaou test, colonoscopy, and PSA screening. Eleven studies revealed a statistically meaningful relationship between the cancer health literacy and cancer screening behaviors. Further research should focus on developing effective interventions and guidelines on cancer health knowledge. The research scope of all areas of cancer health literacy and cancer screening behaviors should be extended to improve the cancer screening rates and public health.

The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment (PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구)

  • Jeong, Jaeho;Kim, Eunsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.147-153
    • /
    • 2014
  • We tried to assessment about characteristics of image through quantitative evaluation method and qualitative evaluation method in Full Field Digital Mammography. It satisfied an approval standard of ten score regardless of compression ratio measuring detection score after compressing and appling an algorithm of JPEG2000 orJPEG compression targeting ACR accreditation phantom. Also, it was apparent that when we selected and compressed the image of real fine lesion and measured a change of diagnosis ability magnifing over 50 percent after compressing over 20:1 ratio, it had a strong influence on diagnosis ability. We realized that the difference between the original image according to compression ratio measuring a quantitative evaluation which is PSNR,RMSE,MAE and SSIM was relatively allowable.

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.