Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

The Irradiated Lung Volume in Tangential Fields for the Treatment of a Breast (유방암의 접선 조사시 피폭 폐용적)

  • Oh Young Taek;Kim Juree;Kang Haejin;Sohn Jeong Hye;Kang Seung Hee;Chun Mison
    • Radiation Oncology Journal
    • /
    • v.15 no.2
    • /
    • pp.137-143
    • /
    • 1997
  • Purpose : Radiation pneumonitis is one of the complications caused by radiation therapy that includes a Portion of the lung tissue. The severity of radiation induced pulmonary dysfunction depends on the irradiated lung volume, total dose, dose rate and underlying Pulmonary function. It also depends on whether chemotherapy is done or not. The irradiated lung volume is the most important factor to predict the pulmonary dysfunction in breast cancer Patients following radiation therapy. There are some data that show the irradiated lung volume measured from CT scans as a part of treatment Planning with the tangential beams. But such data have not been reported in Korea. We planned to evaluate the irradiated lung volume quantitatively using CT scans for the breast tangential field and search for useful factors that could Predict the irradiated lung volume Materials and Methods : The lung volume was measured for 25 patients with breast cancer irradiated with tangential field from Jan.1995 to Aug.1996. Parameters that can predict the irradiated lung volume included; (1) the peruendicular distance from the Posterior tangential edge to the posterior part of the anterior chest wall at the center of the field (CLD) ; (2) the maximum perpendicular distance from the posterior tangential field edge to the posterior Part of the anterior chest wall (MLD) ; (3) the greatest perpendicular distance from the Posterior tangential edge to the posterior part of anterior chest wall on CT image at the center of the longitudinal field (GPD) ; (4) the length of the longitudinal field (L). The irradiated lung volume(RV), the entire both lung volume(EV) and the ipsilateral lung volume(IV) were measured using dose volume histogram. The relationship between the irradiated lung volume and predictors was evaluated by regression analysis. Results :The RV is 61-279cc (mean 170cc), the RV/EV is $2.9-13.0\%\;(mean\;5.8\%)$ and the RV/IV is $4.9-29.0\%\;(mean\;12.2\%)$. The CLD, the MLD and the GPD ave 1.9-3.3cm, 1.9-3.3cm and 1.4-3.1cm respectively. The significant relations between the irradiated lung volume such as RV. RV/EV, RV/IV and parameters such as CLD, MLD, GPO, L. $CLD\timesL,\;MLD\timesL\;and\;GPD\timesL$ are not found with little variances in parameters. The RV/IV of the left breast irradiation is significantly larger than that of the right but the RV/EVS do not show the differences. There is no symptomatic radiation pneumonitis at least during 6 months follow up. Conclusion : The significant relationship between the irradiated lung volume and predictors is not found with little variation on parameters. The irradiated lung volume in the tangential held is liss than $10\%$ of entire lung volume when CLO is less than 3cm. The RV/IV of the left tangential field is larger than that of the right but there was no significant differences in RV/EVS. Symptomatic radiation pneumonitis has not occurred during minimum 6 months follow up.

  • PDF

Evaluation of the usefulness of Halcyon VMAT treatment plan through comparison with tomotherapy in bilateral breast cancer radiation therapy. (양측 유방암 방사선치료 시 토모테라피와의 비교를 통한 Halcyon VMAT 치료계획의 유용성 평가)

  • LIM JUN TAEK;PARK JU YOUNG;PARK SU YEON;JEON SEONG JIN;PARK TAE YANG;HWANG DA JIN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.83-92
    • /
    • 2022
  • Purpose: To evaluate usefulness of Tomotherapy and Halcyon VMAT treatment in radiation therapy for bi-breast cancer Materials and Methods: For 10 patients with bi-breast cancer, volumetric modulated arc therapy(VMAT) treatment plan was established using helical Tomotherapy(Accuray. USA) with field width of 5.0-cm and pitch of 0.287, and Halcyon(Varian Medical System, Palo Alto, CA, Version 3.0 USA) of 6arc and 8arc. Prescribed dose was 42.4 Gy/16, and V 40.3Gy of Planning Target Volume(PTV) was 90%. The quality of plan was evaluated by comparing the dose to tumor and normal organs, and the efficiency was evaluated by comparing total MU and beam on time. Results: About three treatment plans(Tomotherapy, Halcyon 6Arc VMAT, Halcyon 8Arc VMAT) , the mean homogeneity index(H.I) of PTV were 1.07, 1.10, 1.11, and the mean conformity index(C.I) of PTV were 1.21, 1.16, 1.17, respectively. The average value of the dose assessment item for a normal organ is V 5Gy(%) of both lung was 36.3, 31.2, 29.7, and V 15Gy(%) were 18.6, 15.5, 14.6, respectively. The mean heart dose(Gy) were 4.17, 2.69, 2.51. Total MU were (7498.6, 2494.2, 2471.5), and beam on time(sec) were 462.5, 195.4, 198.0. Conclusion: Halcyon VMAT showed similar quality of treatment plan compared to helical Tomotherapy, while also protecting normal organs. In addition, the efficiency of radiotherapy increased due to a decrease in Beam On Time and MU.

The Study for Breast Lymphoscintigraphy of Sentinal Lymph Node in breast cancer (유방암환자 전초림프절의 유방 림프신티그라피에 관한 연구)

  • Kim, Hwa-Gon;Kim, Chang-Soo;Kim, Myung-Jun
    • Journal of radiological science and technology
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2006
  • In the past, most patient of breast cancer suffered side effects due to the useless removement of Axillary Lymph Node, but there is no need to remove it because of the result in this study. The purpose of this study is to save surgery time and side effects after surgical operation for patients with breast cancer by making decisions of operation range for metastasis in first Stenosis Lymph Node using the $^{99m}Tc-Tincolloid$ Scintigraphy and the Micro Probe for radioisotope. As a result of this study, 15 among 20 patients became objects of this study could reduced side effects for operation because there were no axillary lymph node operations. However there is no standard for method of this treatment. It should be standardize where inject point is, how much $^{99m}Tc-Tincolloid$ should be injected(radioactivity value), and the need of massage and Lymph Scintigraphy. Nevertheless I think that this result of study is useful to reduce suffering and side effects from breast cancer and also we should try to do that continuously. The objects for this study were 20 patients diagnosed as breast cancer by Ultrasonography, Mammography & Biopsy. The average of patient age was 45.4 years and its range was between 31 and 71 years. In case of clinical period there were 9 patients of Period I and II patients of Period III. The equipment for this study were $^{99m}Tc-Tincolloid$ describing the Stenosis Lymph Node as a tracer, Micro Probe : Neoprobe 2000(the rest is Gamma Probe) tracing the location, and MS-II Gamma Camera : SIEMENS(the rest is MS-II Gamma Camera) describing the images. There were 3 methods for this study, after selecting one of those methods all 20 patients were performed Stenosis Lymph Node diagnosis & Gamma Probe in operation room. The result was that I imaged all the 20 patients, and seek the Stenosis Lymph Node by using Gamma Probe. Metastasis in Stenosis Lymph Node was 5 and Metastasis in Axillary Lymph Node was 3 between Metastasis in Stenosis Lymph Node cases. Finally 15 patients were also proved that Axillary Lymph Node was Positive and that means there was no Metastasis in Axillary Lymph Node.

  • PDF

Probabilities of Pulmonary and Cardiac Complications and Radiographic Parameters in Breast Cancer Radiotherapy (유방암의 방사선치료에서 방사선학적 지표에 따른 폐 및 심장의 부작용 확률)

  • Noh, O-Kyu;Park, Sung-Ho;Ahn, Seung-Do;Choi, Eun-Kyung;Lee, Sang-Wook;Song, Si-Yeol;Yoon, Sang-Min;Kim, Jong-Hoon
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.23-31
    • /
    • 2010
  • Purpose: To evaluate the relationship between the normal tissue complication probability (NTCP) of 3-dimensional (3-D) radiotherapy and the radiographic parameters of 2-dimensional (2-D) radiotherapy such as central lung distance (CLD) and maximal heart distance (MHD). Materials and Methods: We analyzed 110 patients who were treated with postoperative radiotherapy for breast cancer. A two-field tangential technique, a three-field technique, and the reverse hockey stick method were used. The radiation dose administered to whole breast or the chest wall was 50.4 Gy, whereas a 45 Gy was administered to the supraclavicular field. The NTCPs of the heart and lung were calculated by the modified Lyman model and the relative seriality model. Results: For all patients, the NTCPs of radiation-induced pneumonitis and cardiac mortality were 0.5% and 0.7%, respectively. The NTCP of radiation-induced pneumonitis was higher in patients treated with the reverse hockey stick method than in those treated by other two techniques (0.0%, 0.0%, 3.1%, p<0.001). The NTCP of radiation-induced pneumonitis increased with CLD. The NTCP of cardiac mortality increased with MHD ($R^2=0.808$). Conclusion: We found a close correlation between the NTCP of 3-D radiotherapy and 2-D radiographic parameters. Our results are useful to reanalyze the previous 2-D based clinical reports about breast radiation therapy complications as a viewpoint of NTCP.

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF

Postmastectomy Radiotherapy and Chemotherapy in Patients with Breast Cancer (유방절제술을 시행한 유방암 환자에서 방사선과 항암제 치료성적)

  • Ahn Sung-Ja;Chung Woong-Ki;Nam Taek-Keun;Nah Byung-Sik;Song Ju-Young;park Seung-Jin
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.17-24
    • /
    • 2004
  • Purpose: To evaluate the treatment outcomes after postmastectomy radiotherapy (PMRT) and chemotherapy in patients with breast cancer. Materials and Methods: The PMRT were retrospectively analyzed in 83 patients with stage II-III female breast cancer treated between 1989 and 1995. The median age was 46 years (range, 23-77): Seventy-seven patients had modified radical mastectomies, 5 radical mastectomies and 1 simple mastectomy. Three patients ($4\%$) had pathologically negative axillae, and the remaining 80 ($96\%$) had positive axillae. Eleven, 23, 44 and 5 patients had pathological stages IIA, IIB, IIIA, and IIIB, retrospectively. Eighty ($96\%$) patients were treated with hockey-stick fields. The median dose of PMRT was 50.4 ey, in 1.8 Gy fractions. Adjuvant systemic chemotherapy was given to 74 patients ($89\%$). CMF-based or doxorubicin-containing regimens were given to 54 patients ($55\%$). The median follow-up time was 82 months (range, 8-171) after the mastectomy. Results: The 5 and 10-year overall survival rates for all patients were 65 and $49\%$, respectively. The univariate and multivariate analyses of the factors affecting the overall survival revealed the stage to be the most significant prognostic factor (p=0.002), followed by the combination of chemotherapy. Thirteen patients $16\%$ developed a LRF, at an interval of 4-84 months after radiotherapy, with a median of 20 months. The only significant prognostic factor affecting LRF was the combination of chemotherapy, in both the univariate and multivariate analyses. With respect to the sequence of chemoradiation, the sequence had no saatistical significance (p=0.90). According to the time interval from mastectomy to the onset of radiotherapy, the LRFR of the patients group treated by RT within or after 6 month postmastectomy 6 months were 14 vs. $27\%$ respectively (p=0.24). One third of the pa41en1s (26/83) developed distant metastasis, in 2-92 months, after radiotherapy, with a median of 21 months. The most commonly involved site was bone in 13 cases. The pathological staging was the only significant prognostic factor in both the univariate and multivariate analyses that affected distant failure. Radiological finding of radiation pneumonitis on a simple chest x-ray was shown in $20\%$ (17/83), with a time interval ranging from 2 to 7 months post-radiotherapy, with a median of 3 months. The stable lung fibrosis settled in 11 patients ($65\%$). Conclusion: It was concluded through this analysis that the combination of PMRT with in chemotherapy resulted in better overall survival and local control than PMRT alone in patients needing PMRT.

Dobe Contamination by Tangential Irradiation of Breast Cancer (유방암의 방사선 절선조사에 의한 선량분포)

  • Lee Jong Gul;Lee Byung Jun;Lee Ho Soo;Lee Byung Je
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.67-70
    • /
    • 1994
  • The use of primary breast irraditation with advantage of improved cosmesis in breast cancer may be the potential risks of radiation for a change in the number of normal breast cancers and lung fibrosis. The magnitude of the scattered dose for a variety of radiation treatment techniques from patient of breast cancer and phantom was measured by adequate dosimeters. We can reduce the dose of the normal breast to treated with radiation by understanding the factors contributing to the unwanted dose and by determining ways to decrease this dose.

  • PDF

A Study on Radiation Dose in Mammography (유방촬영(乳房撮影)의 방사선량(放射線量)에 관(關)한 연구(硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Kim, Young-Ill;Choi, Jong-Woon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.31-36
    • /
    • 1981
  • We studied radiation dose in mammography through 34-46 kv range using acryl phantom. The obtained results were as follows: 1. Incident radiation was maximum with high kvp and thin added filtration. 2. Transmitted radiation by acryl phantom and its thickness were in reciprocal relationship. 3. The acryl thickness to produce comparable film density with soft tissue of breast was 6 cm. 4. The X-ray exposure for comparable density radiographs increased mammographic film more than medical x-ray film and the amount of x-ray exposure was directly proportional to the added filtration of x-ray beam. 5. The surface dose of x-ray exposure needed to produce film density of 1.0 for 6cm acryl phantom was 1,084-1,575mR in mammographic film and 476-625 mR in medical x-ray film.

  • PDF

Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation (유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인)

  • Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Bang, Dong-Wan;Kim, Yon-Lae;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.277-282
    • /
    • 2010
  • The study is to verify non-uniform dose distribution in Field-In-Field (FIF) technique using two-dimensional ionization chamber (MatriXX, Wellhofer Dosimetrie, Germany) for breast tangential irradiation. The MatriXX and an inverse planning system (Eclipse, ver 6.5, Varian, Palo Alto, USA) were used. Hybrid plans were made from the original twenty patients plans. To verify the non-uniform dose distribution in FIF technique, each portal prescribed doses (90 cGy) was delivered to the MatriXX. The measured doses on the MatriXX were compared to the planned doses. The quantitative analyses were done with a commercial analyzing tool (OmniPro IMRT, ver. 1.4, Wellhofer Dosimetrie, Germany). The delivered doses at the normalization points were different to average 1.6% between the calculated and the measured. In analysis of line profiles, there were some differences of 1.3-5.5% (Avg: 2.4%), 0.9-3.9% (Avg: 2.5%) in longitudinal and transverse planes respectively. For the gamma index (criteria: 3 mm, 3%) analyses, there were shown that 90.23-99.69% (avg: 95.11%, std: 2.81) for acceptable range ($\gamma$-index $\geq$ 1) through the twenty patients cases. In conclusion, through our study, we have confirmed the availability of the FIF technique by comparing the calculated with the measured using MatriXX. In the future, various clinical applications of the FIF techniques would be good trials for better treatment results.