• Title/Summary/Keyword: 유발프리즘

Search Result 8, Processing Time 0.021 seconds

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.

Induced Prisms of Wearing Glasses Measured by Photographing (사진촬영으로 측정한 착용안경의 유발프리즘)

  • Shin, Hyung-Sup;Jang, Jun-Kyu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.527-532
    • /
    • 2014
  • Purpose: The matching of the optical center and the pupil center was measured by photographs in wearing glasses. In this study, the influences of the induced prism by the mismatching are studied. Methods: 74 subjects (148 eyes) who were spectacles wearer were participated in this study. The mean age was $29.19{\pm}12.22$ years (range 19-55 years). The facial photographs of subjects were taken while wearing spectacles. The matching of the corneal reflected image and optical center of the spectacle lens in the horizontal deviations, and the vertical deviations were measured by the observation of the photo image. The prisms induced in accordance with various frame type were calculated from the mismatching deviations. Results: The binocular horizontal deviations were $1.55{\pm}1.70mm$ for the metal frame, $1.71{\pm}2.21mm$ for the clings type plastic frame, and $1.15{\pm}1.38mm$ for the plastic frame. In the horizontal direction induced prism, the ratio over the tolerance was 23%. The ratio were the 17.6% at the BI prism, and 5.4% at the BO prism. The binocular vertical deviation comparisons were $3.93{\pm}1.91mm$ for the metal frame, $5.79{\pm}1.93mm$ for the clings type plastic frame, and 1$6.01{\pm}2.94mm$ for the plastic frame. In the vertical direction induced prism, the ratio over the tolerance was 44.6%. Based on the refraction power, the ratio were 12.2% at -0.25${\leq}-3.00$, and 32.4% at -3.00${\leq}-12.00D$. Conclusions: The induced prisms in the horizontal direction were much in the BI prism. The binocular vertical deviations of the glasses.

Measurement of Horizontal and Vertical Prism Diopter According to Difference between the Optical Center and Pupil Center (안경 광학중심과 동공중심의 불일치에 의한 수평, 수직 유발프리즘의 측정)

  • Kim, Hyojin;Park, Jee-Hyun;Park, Seon-A;Baek, Ji-Seon;Lee, Eun-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: Measurement of the horizontal and vertical prism diopter was investigated which was occurred due to distance differences between the optical inter-centeral distance (OC) and the interpupillary distance (PD) of the prescribed glasses. Methods: We surveyed 96 subjects (192 eyes) at the average age of 21.56 years old. The PD was measured by using the PD measurement system (DONGYANG PD-85, Korea), and the OC of the glasses was measured by using the projective peak refractive power measurement system (TOPCON CL-200, Japan). The OH value was measured by using Penlight and the PD ruler. Results: The PD which had been measured by the PD system and the OC of the glasses revealed 78.1% of differences. 62.5% of the objects were base-in value prescribed glasses; 58.3% were out of permissible error. Only 8 subject showed concurrence between the prescribed glasses and the OH value, and 82.3% of the objects were induced vertical prism of over 1 (prism diopter). Conclusions: In order to improve the vision function of people who wear glasses, it is necessary to advance the accuracy of PD, OH measurement and making glasses as well.

A Study for the Horizontal Induced Phoria in Spectacles Wearers (안경 장용자의 수평 유발 사위에 관한 연구)

  • Sung, Duk Yong;Lee, Won Jin;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.85-91
    • /
    • 1996
  • Among the 110 glasses wearers, the hyperopic glasses wearers were 18(16.36%) persons and myopic glasses wearers were 92(83.64%) persons. The distance for optical centers was coincided to the pupillary distance in 9(8.18%) persons and discrepant in 101(91.82%) persons. Ophthalmic dispensing Pupillary Distance resulted from testing by the trouble error range(Germany RAL-915), unadopt spectacles had been wearers 52(51.49%) persons. The 65(64.56%) persons and 36(35.64%) persons showed the induced esophoria and the induced exophria, respectively. The maximal induced esophoria was 3.69 prism diopters and maximal induced exophoria was 3.68 prism diopters.

  • PDF

A Study on the Automatic Measurement of Salt Contamination Degree (염분오손도 자동측정 방법에 관한 연구)

  • Kang, Y.W.;Jang, T.I.;Jung, S.C.;Yang, B.M.;Kang, J.W.;Jo, S.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2138-2140
    • /
    • 2000
  • 송전선, 변전소, 발전소 등의 전력설비에 있어서 애자장치의 오손은 지락사고나 코로나 유발에 의한 환경장애 등의 원인이 되고 있어 염분에 의한 애자장치의 오손 대책이 설비 관리에 있어서 중요한 부분을 차지하고 있으며, 이를 위해서는 염분 오손도의 측정이 선행되어야 한다. 본 논문에서는 염분 오손도를 상시 자동으로 측정할 수 있는 방법으로서 제안되고 있는 전자식 애자 이용법, 열전 반도체를 이용한 전도도 측정법, Nd:YAG 레이저법, 레이저 광센서와 프리즘을 이용한 염분 오손도 측정법, 정전용량 검출센서를 이용한 염분 오손도 측정법, 백금 전극을 이용한 누설전류 측정법과 같은 염분 오손도 측정법을 소개하고자 한다.

  • PDF

다채널 표면 플라즈몬 공명 영상장치를 이용한 자기조립 단분자막의 표면 분석

  • Pyo, Hyeon-Bong;Sin, Yong-Beom;Yun, Hyeon-Cheol
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.74-78
    • /
    • 2003
  • Multi-channel images of 11-MUA and 11-MUOH self-assembled monolayers were obtained by using two-dimensional surface plasmon resonance (SPR) absorption. Patterning process was simplified by exploiting direct photo-oxidation of thiol bonding (photolysis) instead of conventional photolithography. Sharper images were resolved by using a white light source in combination with a narrow bandpass filter in the visible region, minimizing the diffraction patterns on the images. The line profile calibration of the image contrast caused by different resonance conditions at each points on the sensor surface (at a fixed incident angle) enables us to discriminate the monolayer thickness in sub-nanometer scale. Furthermore, there is no signal degradation such as photo bleaching or quenching which are common in the detection methods based on the fluorescence.

  • PDF

The Understanding of Determination of Horizontal Centration Point of Single-vision Reading Glasses (단초점 근용 안경의 수평방향 설계점 결정에 대한 이해)

  • Kim, Min Ho;Kim, Hyun-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purpose of this study is to compare degrees of asthenopia in after wearing of dispensed reading glasses with different criterion of P.D. Methods: The person who has minus near correction power (distance correction value (-)) is compared to the degree of asthenopia by wearing of dispensed reading glasses with near P.D(-B) and distance P.D. The person who has plus near correction power is compared to degree of asthenopia by wearing of dispensed reading glasses with near P.D-B, distance P.D, near P.D-A. The "Near-P.D-A" means reduced optical centre distance of reading glasses of positive correction value at which the same effect of prism B.O through near visual point in distance glasses exist at near visual point in reading glasses. Results: When near correction value is (-), dispensed reading glasses with distance P.D have caused less asthenopia than dispensed glasses with near P.D-B. When the near correction value is (+), we cannot confirm that which P.D is more useful for reading glasses. As a result of this study, dispensed reading glasses with near P.D-A have caused less asthenopia than another criterion of P.D. Conclusion: The effect of prism B.I through a near visual point in distance glasses ((-) correction value) reduce convergence demand. Therefore (-) correction value-reading glasses support convergence in near vision, because the effect of prism B.I of reading glasses is smaller than that of distance glasses. When the near correction value is (+), centration points can be determined by one of near P.D-A, near P.D-B, distance P.D.

  • PDF

Interpretation of in Plural Analysis (<센과 치히로의 행방불명>의 다원적 해석)

  • Pyo, Jeong-Hee;Lee, Tae-Gu
    • Cartoon and Animation Studies
    • /
    • s.42
    • /
    • pp.81-104
    • /
    • 2016
  • was released in South Korea in 2002 with more than 2million audiences and had been appraised as a successful and sensational work. The work let the audiences highly evoke interest and curiosity through offering magnificent sceneries, weird and funny creatures and stimulating imagination, before having no idea about the work producted by Miyajaki Hayao, one of the greatest directors. Well-concentrated his works seem to be easy to understand but have a variety of meanings in very different ways. Expending the range of analysis of his works, for example, from its technical to cultural and philosophical etc. has an enormous amount of value of diversity such as a ray of light passing through a prism. For this reason, has been studied in many different views. This paper will analyse this animation in respect of ideas of eastern as well as western to show differences from former papers. The ideas of eastern and western seem to be not in a line, but this study will suggest that the two different ideas are not different, actually. Through plural analysis of , ask questions about what life is and what the direction is.