• 제목/요약/키워드: 유로판

검색결과 61건 처리시간 0.034초

다공판 유로 내의 유동한계(CCFL)에 대한 실험적 연구 (The Experimental Study on The Counter-Current Flow Limit in The Flow Path with a Porous Plate)

  • 양승우;이진기;권정태;김상녕;강용태
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.156-161
    • /
    • 2007
  • A set of experiments of counter-current flow limit (CCFL) was performed to improve the drawbacks of Wallis' correlation which neglected the effects of channel size, channel length, injection method and the boundary conditions at the inlet of liquid and gas phase. In this study, CCFL was observed by changing the shape of porous plate using air and water. The results show that as the size of porous increases, CCFL with a round shape of the porous plate start to disappear, In this study, the CCFL correlation was calculated and the corresponding CCFL map was developed based on the experimental results.

연료전지 냉각판의 냉각 특성에 대한 수치해석적 연구 (Numerical Simulation on Cooling Plates in a Fuel Cell)

  • 김윤호;이용택;이규정;김용찬;최종민;고장면
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.86-93
    • /
    • 2007
  • The PEM (polymer electrolyte membrane) fuel cell is one of the promising fuel cell systems as a new small power generating device for automobiles and buildings. The optimal design of cooling plates installed between MEA (membrane electrode assembly) is very important to achieve high performance and reliability of the PEMFC because it is very sensitive to temperature variations. In this study, six types of cooling plate models for the PEMFC including basic serpentine and parallel shapes were designed and their cooling performances were analyzed by using three-dimensional fluid dynamics with commercial software. The model 3 designed by revising the basic serpentine model represented the best cooling performance among them in the aspect of uniformity of temperature distribution and thermal reliability, The serpentine models showed higher pressure drop than the parallel models due to a higher flow rate.

탄소복합소재 분리판을 이용한 소형 고분자전해질 연료전지 스택 제작 및 성능분석 (Manufacture and Evaluation of Small Size PEMFC Stack Using Carbon Composite Bipolar Plate)

  • 한춘수;최만수;이지정;이재영;김인태;안정철;심중표;이홍기
    • 전기화학회지
    • /
    • 제13권2호
    • /
    • pp.81-88
    • /
    • 2010
  • 탄소복합소재 분리판의 연료전지 성능을 시험하기 위해 소형 고분자연료전지 스택을 제작하였으며 연료전지 운전에 따른 성능변화를 측정하여 탄소복합소재 분리판이 연료전지 스택의 성능에 미치는 영향을 조사하였다. 자체 설계한 가스유로로 디자인된 분리판과 MEA를 적층한 스택의 초기 성능과 장기간 운전에 따른 전압 감소를 측정하였다. 또한 장시간 운전 동안 각 셀의 전압 거동도 함께 측정하였으며 비교를 위해 흑연분리판을 이용하여 제작한 스택의 성능도 함께 시험하였다. 스택에서 각 셀의 성능은 단위전지에서의 성능과 유사하게 나타나 분리판과 스택의 구조가 셀의 성능을 충분히 보여줄 만큼 적절히 디자인된 것을 알 수 있었으며, 장시간 운전 동안 전류가 증가함에 따라 스택의 성능 감소도 점차 증가하였으며 두 종류의 스택이 유사한 성능 감소를 보여 자체 제작한 탄소복합소재 분리판이 흑연분리판과 유사한 성능을 보임을 알 수 있었다.

120kW급 하이브리드 전기 차량 구동용 IPMSM 제어기 개발 (A Development of 120kW Motor Control Unit for Hybrid Electric Vehicles)

  • 이재현;목형수;이지명;박래관;이진주;김상민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.16-17
    • /
    • 2011
  • 본 논문에서는 120kW급 하이브리드 전기 차량용 IPMSM 제어기 개발 사례를 소개 한다. 높은 출력 밀도를 요구하는 하이브리드 전기차량의 특성을 고려하여 개발된 IPMSM(매입형 영구자석 동기전동기)를 대상으로 대전류, 고효율 시스템 구성을 위해 수냉식 MCU(Motor Control Unit)를 개발 하였다. 또한 효율적인 차량 전원 배선 및 냉각 유로 구성을 고려한 전원 분배 기능 및 방열판 설계기법이 적용 되었다. 개발된 MCU를 모의 해석 및 실험을 통해 검증 하였다.

  • PDF

수소가스발생 장치의 전해조 분라판의 유로설계에 관한 전산모사 연구 (A study on the channel design of bipolar plate of electrolytic cell of hydrogen gas generation system by flow dynamic simulation)

  • 조현학;장봉재;송주영
    • 한국응용과학기술학회지
    • /
    • 제27권2호
    • /
    • pp.152-156
    • /
    • 2010
  • This study is focused on the channel design of bipolar plate in the electrode of hydrogen gas generator. The characteristics of hydrogen gas generation was studied in view of efficiency of hydrogen gas generation rate and a tendency of gas flow through the riv design of electrode. Since the flow rate of generated gas is the most crucial in determining the efficiency of hydrogen gas generator, we adopted the commercial analytical program of COMSOL $Multiphysics^{TM}$ to calculate the theoretical flow rate of hydrogen gas from the outlet of gas generator.

Six sigma 기법을 이용한 PEMFC Cathode 유로설계 최적화 (Optimization of Cathode Flow Field Design for a PEMFC with Six Sigma Technique)

  • 김선회
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.492-498
    • /
    • 2009
  • Six sigma methode was applied for optimization of flow field design of a proton exchange membrane fuel cell (PEMFC). The optimization between number of channel and channel/rib width was suggested in this paper with six sigma method. With the help of six sigma design of experiment (DOE) the number of experiments may be reduced dramatically. The fuel cell channel design optimization with results of these experiments with a 100 $cm^2$ serpentine flow field indicates a optimization data for a given constant operating conditions.

SOFC 셀 성능 향상 및 수명 저하 방지를 위한 입구와 출구 2개의 유로 설계 (Design of flow path with 2 inlet and outlets to improve cell performance and prevent cell degradation in Solid Oxide Fuel Cell)

  • 김동우;염은섭
    • 한국가시화정보학회지
    • /
    • 제19권2호
    • /
    • pp.56-62
    • /
    • 2021
  • Solid oxide fuel cells (SOFCs) is the high efficiency fuel cell operating at high temperatures ranging from 700-1000℃. Design of the flow paths of the fuel and air in SOFCs is important to improve cell performance and prevent cell degradation. However, the uneven distribution of current density in the traditional type having one inlet and outlet causes cell degradation. In this regard, the parallel flow path with two inlet and outlets was designed and compared to the traditional type based on computational fluid dynamics (CFD) simulation. To check the cell performance, hydrogen distribution, velocity distribution and current density distribution were monitored. The results validated that the parallel designs with two inlets and outlets have a higher cell performance compared to the traditional design with one inlet and outlet due to a larger reaction area. In case of uniform-type paths, more uniform current density distribution was observed with less cross-sectional variation in flow paths. In case of contracted and expanded inflow paths, significant improvement of performance and uniform current density was not observed compared to uniform parallel path. Considering SOFC cell with uniform current density can prevent cell degradation, more suitable design of SOFC cell with less cross-sectional variation in the flow path should be developed. This work can be helpful to understand the role of flow distribution in the SOFC performance.

대직경 스터드 전단연결재의 정적거동 (Static Behavior of Large Stud Shear Connectors)

  • 이필구;심창수;윤태양
    • 한국강구조학회 논문집
    • /
    • 제15권6호통권67호
    • /
    • pp.611-620
    • /
    • 2003
  • 강합성교량에서 19mm 또는 22mm 직경을 갖는 전단연결재가 일반적으로 사용되고 있다. 강교 상세의 단순화와 향후 바닥판 제거의 용이성 및 프리캐스트 바닥판 전단포켓의 효율적인 배치를 위해서는 대직경 스터드 전단연결재가 필요하다. 현재의 전단연결재 설계범위를 넘어서는 대직경 스터드 전단연결재에 대한 push-out 실험을 통해서 정적거동에 관한 항목들을 검토하고 기존 설계식과의 비교를 수행하였다. 25, 27, 30mm 직경의 스터드에 대한 전단실험을 통해서 탄성영역에서의 전단강성을 평가하고 세 개의 직선으로 구성된 하중-상대변위 곡선을 제안하였다. 파괴시의 극한상대변위를 평가하고 극한강도를 유로코드-4의 설계식과 비교하여 설계의 안전율을 평가하였다. 또한 30mm 스터드의 경우는 용접과 콘크리트 지압능력의 개선이 필요한 것으로 나타났다.

용융탄산염형 연료전지 분리판 재료의 부식거동

  • 이충곤
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 1998년도 춘계학술발표회 초록집
    • /
    • pp.21-21
    • /
    • 1998
  • 새로운 에너지원으로 각광받고 있는 연료전지는 우주선 동력윈으로서의 이용이래, 보다 실용적인 발전 시스템을 목적으로 많은 연구개발이 시도되고 있다. 이러한 연료전지는 사용하는 전해질의 특성으로 인하여 저온형($<300^{\circ}C$) 과 고온형($500^{\circ}C<$)으로 구분된 수 있는데, 저온형 연료전지의 경우는 전극반응 특성상 귀금속 촉매가 필요한 데 비해, 고온형 연료전지는 이러한 귀금속 촉매가 필요없다는 점등에서 다양한 장점을 가지게 된다. 즉, 저온형에 비해 다양한 연료가 가능하고, 대형화에 유리함며, 고온 페열을 이용할 수 있는 점 등을 들 수 있다. 용융탄산염형 연료전지(MFCFC)는 이러한 고온형 연료진지의 장점을 배경으로 현재 대규모의 개발이 진행되고 있다. 그러나 여기에 주로 사용되는 Li-K, Li-Na와 같은 용융탄신엽은 고부식성 전해질로서 대부분의 금속이 산화물을 형성하는 것으로 알려져 있다. MCFC의 분리판은 셀간을 전기적으로 이어주는 역할, 가스의 유로제공 및 가스 Sealing의 역할을 담당하는 부분으로서, 분리판의 부식은 이러한 특성의 저하 및 전해질의 소모를 유발시켜 MCFC의 내구성에 커다란 영향 을 미치는 요인으로 생각되고 있다. 이러한 배경으로부터 Uchida 그룹은 MCFC의 분라판 재료 의 부식거동을 계동적으로 검토하였다. 먼저 Fe에 Ni 과 Cr을 첨가한 재료를 산화성가스 분위기하에서 $(Li+K)CO_3$에 대하여 검토한 결과, Ni과 Cr 둘다 20wt%이상 첨가시, 내식성융 가지는 결 과를 보고하였다2) 이 경우 보호피막으로서 NiO 와 $LiCrO_2$가 작용하는데, $LiCrO_2$가 용융탄산염 중에서 보다 안정한 것으로 부터, Cr의 첨가가 내식성에 기여하는 것으로 판단하였다. 다음 단계 로서 Fe/Cr재료에 용-융탄산염 중에서 안정한 산화물을 형성하는 Al의 첨가효과를 검토하였다. Al의 첨가는 더욱 내식성을 향상시키는 것이 발견되었고, 약 4wt%의 첨가로 충분한 내식성을 가지 는 것을 보고 하였다. 그러나 이러한 안정한 산화물에 의한 내식성 향상은 전기진도도의 희생을 바탕으로 한 것으로서, 다읍 단계로서 Ti산화물의 반도체적인 특성을 이용하고자 제 4의 원소로서 Ti첨가를 시도하였다. 그러나 Fe/Cr/AVTi재료가 뛰어난 내식성을 가지는 것은 관찰되었으나, 전도도 향상에는 기여하지 못하는 것이 보고되었다. 현재 MCFC는 실용화를 위한 고성능화의 하나로서 가압하에서의 운전을 시도하고 있다. 이 러한 가압하에서의 운전은 기전력의 향상 및 전극반응의 촉진 등으로 출력의 향상을 가져오나. 현재 문제로 되고 있는 Cathode극인 NiO의 용해/석출 현상을 가속화하는 결과를 초래해, 이에대 한 대책으로서 Li-K보다 NiO의 용해가 적은 Li-Na탄산염으로의 전환이 진행되고 있다. 이러한 배경으로부터 Uchida그룹에서 개발한 FeiCr/AVTi재료와 현재 분리판 재료로 사용증인 SUS 310, S SUS 316재료에 대해. 산화성 분위기의 5기압까지의 가압하에서, Li-K, Li-Na탄산염에 대하여 부 식거동을 검토한 결과, 가압하에서 내식성이 향상되는 것이 발견되었다. 이유로서는 가압하에서 용융탄산엽의 증가된 산화력으로 보다 치밀한 내식성 산화물 피막이 형성되기 때문으로 생각되고 있다. 또한 Li-K, Li-Na탄산염에서의 부식의 정도에는 차이가 거의 없었으나, SUS 316의 경우 탄산염에 젖은 부분에서 내식성 피막이 형성되지 않는 이상부식현상이 관찰되었다. 재료간의 내식성 정도에서는 Fe/Cr/Al/Ti이 가장 내식성이 뛰어났으며, SUS 310 또한 뛰어난 내식성을 보였다.

  • PDF

강섬유로 보강된 초고성능 콘크리트 바닥판과 역T형 강거더 합성보의 휨거동 실험 (Experiment of Flexural Behavior of Composite Beam with Steel Fiber Reinforced Ultra High Performance Concrete Deck and Inverted-T Steel Girder)

  • 유성원;안영선;차영달;조창빈
    • 콘크리트학회논문집
    • /
    • 제26권6호
    • /
    • pp.761-769
    • /
    • 2014
  • 인장강도 및 휨강도가 낮고 취성파괴의 특성을 가지는 일반적인 콘크리트의 단점을 극복하기 위하여 최근에는 압축강도가 180 MPa이상인 고성능 콘크리트에 강섬유를 혼입한 강섬유 보강 초고성능 콘크리트(UHPC)에 대한 연구가 활발히 진행되고 있다. UHPC 바닥판과 강재 거더를 이용하여 합성보를 구성할 때, UHPC 바닥판의 높은 강도와 강성으로 인하여 강재거더 상부 플랜지의 역할이 거의 불필요할 것으로 예상된다. 이러한 점을 착안하여 본 논문에서는 합성보 구성 시에 강재 거더의 상부플랜지를 없앤 역T형 거더를 적용하였다. 역T형 거더에 UHPC바닥판을 합성하여 합성보를 구성할 경우, 상부플랜지가 없는 이유로 전단연결재의 설치 위치가 상부플랜지 대신에 강재 거더 복부에 설치해야하는 문제점이 발생되며, 강재 복부에 설치되는 전단연결재에 대한 거동, 역T형 강거더 합성보의 휨거동 특성 등은 현재까지 실험 및 이론적으로 평가된 적이 거의 없는 실정인 이유로 이에 대한 연구가 절실하다. 이를 위하여 본 논문에서는 전단연결재 간격, 바닥판 두께 등을 변수로 하여 역T형 거더와 UHPC바닥판을 합성한 합성보를 8개 제작하여 전단연결재의 거동, 휨거동 특성 등을 파악하고자 하였다. 실험결과를 기준으로 볼 때, 향후 UHPC의 경우 스터의 간격은 100 mm에서 바닥판 두께의 2~3 배 사이로 규정함이 적절할 것으로 예상된다. 또한 실험 부재의 특성 상대변위는 Eurocode-4의 연성거동 기준에 의하면 충분한 연성 거동을 하는 것으로 판정되었으며, 바닥판이 지나치게 얇고 전단연결재의 간격이 지나치게 넓은 경우를 제외한 대부분의 부재들은 일반 콘크리트보다 UHPC의 성능이 우수하여 기존의 AASHTO LRFD 및 Eurocode-4의 식과 실험결과간의 차이가 있음을 알 수 있다.