• Title/Summary/Keyword: 유량측정 기준

Search Result 271, Processing Time 0.029 seconds

A Study on the Runoff Characteristics and Water Quality Management of Seung-Gi Stream Area (승기천 유역의 오염물 유출특성 및 수질관리방안 연구)

  • Seo, Hyung-Joon;Chung, Sang-Won;Park, Mi-Ok;Lee, Byung-Ryul
    • Clean Technology
    • /
    • v.7 no.4
    • /
    • pp.251-263
    • /
    • 2001
  • This study was conducted to provide a basic information for recovery plan of Seung-Gi Stream which is a major stream of Incheon metropolitan area. Source and characteristics of pollutants were analyzed and studied. Samples were taken 10 rounds in 5 sections in Seung-Gi stream. Annual pollutants loads and sectional characteristics of pollutants loads were investigated regarding flow rate, pH, DO, SS, $BOD_5$, $COD_{Cr}$, T-P, TKN and concentrations of Zn, Cd, Cu, Cr atoms which enter into Seung-Gi stream during rainy and dry season respectively. As one came close to the Nam-Dong Industrial Complex, sectional discharge loads were heavy and water quality was failed to meet the standard by "Environmental Standard of River Quality". As a result, heavy load of pollutants in Seung-Gi stream was considered to influence negatively the sea water quality of Incheon. Solution plans to solve problems are as follows. First, circulation of treated water at Seung-Gi WWTP(Wastewater Treatment Plant) and retreated water by URC(ultra rapid coagulation) process treat with that. Second, sewage and wastewater is gathered, make it disposed. After then, we circulate treated water. If solution plans be applied, we can predict water quality. Then we could grope for how make to recovery role of Seung-Gi stream as stream.

  • PDF

Enhanced Catalytic Activity of Cu/Zn Catalyst by Ce Addition for Low Temperature Water Gas Shift Reaction (Ce 첨가에 따른 저온수성가스전이반응용 Cu/Zn 촉매의 활성 연구)

  • Byun, Chang Ki;Im, Hyo Bin;Park, Jihye;Baek, Jeonghun;Jeong, Jeongmin;Yoon, Wang Ria;Yi, Kwang Bok
    • Clean Technology
    • /
    • v.21 no.3
    • /
    • pp.200-206
    • /
    • 2015
  • In order to investigate the effect of cerium oxide addition, Cu-ZnO-CeO2 catalysts were prepared using co-precipitation method for water gas shift (WGS) reaction. A series of Cu-ZnO-CeO2 catalyst with fixed Cu Content (50 wt%, calculated as CuO) and a given ceria content (e.g., 0, 5, 10, 20, 30, 40 wt%, calculated as CeO2) were tested for catalytic activity at a GHSV of 95,541 h-1, and a temperature range of 200 to 400 ℃. Cu-ZnO-CeO2 catalysts were characterized by using BET, SEM, XRD, H2-TPR, and XPS analysis. Varying composition of Cu-ZnO-CeO2 catlysts led the difference characteristics such as Cu dispersion, and binding energy. The optimum 10 wt% doping of cerium facilitated catalyst reduction at lower temperature and improved the catalyst performance greatly in terms of CO conversion. Cerium oxide added catalyst showed enhanced activities at higher temperature when it compared with the catalyst without cerium oxide. Consequently, ceria addition of optimal composition leads to enhanced catalytic activity which is attributed to enhanced Cu dispersion, lower binding energy, and hindered Cu metal agglomeration.

Monte Carlo Simulation Using QUALKO2 Model for Water Quality Reliability Analysis (수질 신뢰도 분석을 위한 QUALKO2 모형의 Monte Carlo 해석)

  • Han, Kun-Yeun;Choi, Hyun-Gu;Kwon, Na-Young;Im, Jae-Tae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.2058-2062
    • /
    • 2009
  • 1992년 한강수계법이 제정되면서 우리나라에 도입된 오염총량관리제는 현재 2차총량관리 시행계획수립 단계에 이르렀다. 오염총량제에서 수질모델은 수계구간별로 설정된 기준유량과 목표수질 조건을 달성하는 지를 판단할 수 있는 도구로 사용되며, 다양한 모델들이 사용되고 있다. 그 중 하천수질모형으로는 주로 QUAL2E, QUALKO, QUALKO2 모형으로 압축할 수 있다. QUAL2E 모형은 1980년대에 개발되어 국내외로 널리 이용하고 있으나 SOD를 0차나 일정량으로 처리하였고, 부착조류에 의한 용존산소 변화와 부유 조류 사멸시 발생하는 유기물이 고려되지 않았다. 또한 용존산소가 부족한 상태에서 반응이 활발한 탈질화과정이 포함되지 않아 이들 반응에 의해 수질이 영향을 받는 하천에 적용하기에는 한계가 있었다. 그리고 QUAL2E 모델은 여러 개의 지류를 가진 대형 하천에는 적용하기 어려운 단점이 있다. 국내에서는 1999년 QUAL2E 모델에 WASP5의 장점을 접목시켜 QUALKO 모델을 개발하였다. 이 모델은 QUAL2E에 부유성 조류의 사멸로 인한 유기물의 내부증가, 탈질화 반응 및 부착식물의 광합성 호흡 과정을 추가한 것이다. 또한 QUAL2E 모델에서 BOD는 CBOD로 입력되고 모의되므로 bottle BOD의 개념이 결여되어 있으므로 이러한 문제점을 보완하고, 조류의 생산 및 사멸에 의한 내부생산 유기물 증가와 탈질화 반응 과정을 추가한 것이다. 우리나라에서 진행되고 있는 총량관리 대상물질은 2010년까지는 $BOD_5$이며, 2011년부터는 일부 지역에 총인이 포함될 예정이다. 2007년에 실험실에서 측정하는 BOD5나 유기성 질소 또는 유기성 인을 그대로 입력하여 계산되고 출력할 수 있으며, 향후 오염총량제의 관리대상항목으로 논의되고 있는 TOC를 모의할 수 있는 QUALKO2가 개발되었다. 이에 본 연구에서는 향후 활용도가 클 것으로 기대되는 QUALKO2 모형에 기존 QUAL2E-UNCAS 모형에 서 수행할 수 있는 불확실성 해석 기법인 Monte Carlo 모의를 가능하도록 모형을 수정하고자 한다. 실제 하천에서의 수질해석에 대한 단순한 표현인 수학적 모형은 불확실성을 내포하고 있으며, Monte Carlo 해석을 사용하여 모형의 불확실도 정량화와 매개변수의 불확실성을 통계학적으로 기술할 수 있다. 또한 각 지점에 대한 계산결과치들에 대해 빈도 및 누가빈도분포 값을 제시함으로서 모형 예측치들의 전반적인 분포경향을 평가할 수 있으며, 하천수질에 대해서 환경기준치를 위배할 가능성을 산정하는데 활용할 수 있다. 우리나라 실정에 맞는 QUALKO2 모형에 Monte Carlo 모의를 통해 신뢰도 기반의 수질해석을 수행하게 된다면 수질정책의 기초자료 제공에 기여할 것으로 판단된다.

  • PDF

Practical Research for Quantitative Expression of Leakage Through Optical Gas Image (광학가스이미지에서 유출량의 정량표시 실험적 연구)

  • Park, Suri;Han, Sang-wook;Kim, Byung-jick
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.16-26
    • /
    • 2017
  • In chemical industry plants, the raw material, intermediate and final products can leak from unstable joints of flanges and valves as well as cracks of storage tanks. From the safety and economic standpoints, it is very important to understand whether leaks or not and leakage rate. The OGI(optical gas image) technique can tell gas leakages, but cannot give the leakage rate. Some special OGI devices can show the kind of gas in different color concentration in different darkness. Therefore the research on quantification of OGI is necessary. In this research, we have developed the practical method to quantify OGI of methane leakage. To estimate 3-dimensional gas leakages distribution from 2-dimensional OGI, the Monte Carlo Probability technique was applied. First the number of points in the area of width(2.54 cm) and length(2.54 cm) in OGI was counted. Total no of each experiment was compared with the measured flow rate. The correlation average between total points and measured flow rate was found to be 0.980. Reversely we estimated the leakage rate of OGI by use of the correlation table. The results showed good agreement between the estimation value and the measured value.

Application of Heat Balance Model Design of Ventilating and Cooling Greenhouse (온실의 환기 및 냉방 설계를 위한 열평형 모델의 작용)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.201-206
    • /
    • 2000
  • A certain system to overcome high temperature should be introduced for the stable year-round cultivation in greenhouses. There are efficient methods to overcome high temperature such as ventilation system with shading screen, fan and pad system with screen, and fog system with screen. This study was carried out to find a means to determine the capacity of such system. Heat balance equations for each system were established and verified by experimental results. The calculated ventilation rates from heat balance equations showed a good agreement with the measured ones. The evapotranspiration coefficient was the most important parameter affecting the ventilation requirement among input parameter affecting the ventilation requirement among input parameters except weather data. When the evaportanspiration coefficient increased 1%, the ventilation requirement decreased 1.3%. Therefore the data of evapotranspiration coefficient should be accumulated by various experiments, and then design standards and selection guidelines should be provided. The simulation results for same design conditions shown that air exchanges requirement and evaporating water of fan and pad system were 5.1∼7.7% and 6.8∼9.3% larger than those of fog system, respectively.

  • PDF

Verification on the Design Formulas of Apron Length by Scour Analysis at Weir Downstream (보 하류부 세굴 분석을 통한 물받이공 길이 설계 공식 검토)

  • Ko, Dongwoo;Lee, Changhun;Kang, Joongu
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.2
    • /
    • pp.83-89
    • /
    • 2020
  • This hydraulic study analyzed the scour effect at fixed downstream weirs based on the changes in the upstream bed slope. The study was performed using six different bed slopes, that is, 0%, 2%, 3%, 4%, 7%, and 10% at 0.117 ㎥/s in all cases. The scour depth, scour length, and scour volume were measured using a broadband laser scanner to quantitatively analyze the scour at the downstream weir. This study also examined the adequacy of the designed apron length by comparatively analyzing the results of the scour experiments and the apron length calculated using conventional design standard formulas. The analysis of the local scour effect at the downstream weir showed that scour length and scour depth increased as the bed slope became steeper. A comparison between the results of the scour experiment and that of the conventional design formulas showed that both formulas of the National Construction Research Institute and the Bligh were distributed within the allowable values when there was no upstream bed slope. However, as the bed slope upstream of the weir gradually increased, the scour lengths of the apron deviated slightly from the values obtained from the conventional design formulas.

Analyzing the effect of LID(Low Impact Development) using the CAT(Catchment hydrologic cycle Assessment Tool) (CAT을 이용한 LID(Low Impact Development) 효과 분석)

  • Jang, Cheol-Hee;Kim, Hyeon-Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.278-278
    • /
    • 2012
  • 최근 녹색도시를 지향하면서 도시 내에서의 물의 순환에 대한 관심이 높아지고 있으며 도시계획 단계에서부터 물의 순환을 고려하려는 시도가 이루어지고 있다. 국토해양부, 환경부, 소방방재청 및 지방자치단체들은 법령, 기준, 지침 및 조례 등을 제정하여 물순환을 도시개발 이전의 상태가 될 수 있도록 시설 설치를 유도하고 있다. 그러나, 개별시설들의 조합이 유역규모의 물순환에 미치는 영향 평가는 이루어지고 있지 못한 실정이다. 종래에는 홍수저감을 목적으로 홍수저류지와 침투시설에 대하여 설계하고 시공을 하였으나 장기적인 관점에서 LID 시설의 효과를 평가하여 도시 계획 단계에서 반영하지는 못하였다. 그리고 이들 개별 LID 시설(침투, 저류 등)에 대한 단위 시설의 규모 설계에 그치고 있어 개선 시설이 다중으로 조합되어 분산 계획되었을 경우, 유역 규모에서 물순환의 긍정적인 변화를 판단하기는 어려운 형편이다. 도시지역에서의 LID(Low Impact Development) 효과 분석과 연계된 유역 물순환 해석을 위하여 독일, 호주 및 미국에서는 STORM, Urban Developer, SUSTAIN(System for Urban Stromwater Treatment, and Analysis INtegratration) 및 SWMM LID(Storm Wastewater Management Model LID) 등의 모형을 출시하고 실무에 적용하고 있다. 그러나, 해외에서 개발된 기술은 국내의 유역 환경을 충분히 반영하기 어렵다. 저수지 혹은 하천에서의 취수 등과 같이 국내의 복잡한 물순환 형태를 반영하는데 한계가 있으며, 기존의 물순환 해석모형에 의한 LID 시설을 계획하는 방법은 홍수저감에 국한되어 있고, 하천 유량이나 지하수위 측정 자료가 부족한 대상지역에 대한 장기적인 유역 물순환 및 도시 개발과 같은 토지이용 변화가 물순환에 미치는 영향을 해석하는데 있어 제한이 있고, 개별적으로 설치된 LID 시설들이 유역의 물순환을 개선하는 효과를 종합적, 정량적으로 구현하는데 한계가 있다. 본 연구에서는 도시 개발 지역의 장기간에 걸친 물순환의 변화를 예측하고 물순환을 개선시키는 대안 시설의 효과를 사전에 평가하는 것을 목표로 김현준 등(한국건설기술연구원, 2011)이 개발한 유역 물순환 해석 모형인 CAT(Catchment hydrologic cycle Assessment Tool)을 이용하였다. 특히, CAT은 사용자의 목적에 맞는 다양한 물순환 개선시설(침투시설, 저류지, 습지, 빗물저장 시설, 리사이클 및 외부급수 등)의 구현 및 모의가 가능하도록 개발되었다. 대상유역으로는 경기도 Y지구를 선정하였으며 도시개발 시나리오(전원도시 및 산업도시 등)에 따른 LID 효과 분석을 실시하였다. 대상지역에 대한 도시유형별 개발계획에 따른 개발 전 후 물순환 변화량 분석 및 LID 시설 계획에 의한 물순환 개선효과를 살펴보면 1998년부터 2007년까지의 평균 강우량을 1,271mm라고 할 때 산업도시의 경우 도시 개발 전의 증발산, 직접유출 및 기저유출은 각각 53%, 29%, 19%로 나타났으며 도시 개발 후 35%, 54%, 12%로 직접유출이 개발 전에 비해 86%나 증가하여 개발에 따른 영향이 큰 것으로 나타났다. 따라서, 이러한 개발에 따른 영향을 최소화하기 위하여 LID 시설을 계획하여 효과를 분석한 결과 증발산, 직접유출, 기저유출이 44%, 34%, 13%로 나타나 도시 개발 후의 왜곡된 물순환 체계가 개발전의 수준과 근접하게 나타나 LID 시설의 긍정적인 효과를 검토할 수 있었다. 이상에서와 같이 CAT 모형을 사용하여 도시유역의 물순환 체계를 진단하고, LID 시설의 효과를 평가할 수 있게 됨으로써 향후 도시유역에 대한 물순환 정상화를 실현하기 위한 정책 수립에 기초자료를 제공하고, 설계 실무에 활용될 수 있을 것이다.

  • PDF

The Development of High Pressure Long Distance Fire-fighting Hose with Phosphorescent Performance (축광 성능을 갖는 고압용 장거리 호스 개발에 관한 연구)

  • Han, Yong-Taek;Na, Byung-Gyun;Choi, Jin-Seong;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.63-69
    • /
    • 2017
  • This study describes the development of a long-distance hose for ultra-high pressure operation, which can be used in conjunction with an ultra-high pressure pump and can be effectively applied to the fire suppression of high-rise buildings and a long, large tunnels. Also, it has phosphorescent properties, which can help to secure the withdrawal route of the fire-fighters when they are threatened by the fire. We developed an ultra-high pressure hose aiming at a pressure of 3 MPa and a flow rate of 2000 lpm and developed an ultra-high pressure fire hose that can withstand this very high pressure by using a double jacket, triple polyurethane coating and warf (Wp) of 52. In order to ensure the performance of the developed ultra-high pressure hose, its structure, appearance, leakage at high pressure, length and elongation were inspected by a certified certification agency, who also subjected it to a peeling test, friction test, breaking pressure test and free fall test. Also, it was studied in addition to the luminescent high-pressure hose for fire-fighting. In the phosphorescence test, the luminance measurement value was more than the reference value of the luminance test after 40 minutes, which confirmed that its performance was satisfactory for fire-fighting products. In the future, if such an ultra-high pressure fire hose were commercialized and applied in the field, it could contribute to securing improved fire suppression and safer exit from fires, as compared to the fire hoses currently used in the suppression of fires in skyscraper buildings and long tunnels.

Analysis of Density Current in the Tidal River (감조하천(感潮河川)의 하구(河口) 밀도류해석(密度流解析))

  • Suh, Seung Duk;Park, Sung Bae
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.70-76
    • /
    • 1986
  • The purpose of this study is to offer the basic data of the tidal river development program by grasping the diffusion between the high density-sea water and the low density-fresh water in the tidal river. The tidal range of Hyungsan river which flows at Youngil bay in Pohang was selected to analysis the phenomenon of density current. The results obtained are as follows ; The tide of Youngil bay was one time a day, 0.104m in high tide difference and 0.085m in mean tidy difference. The change of sea level by tide was negligible. The volume of reserved water by sea water was $2,700,000m^3$ and available water of irrigation was $1,200,000m^3$ that salt density is below $750{\mu}{\mho}/cm$ out of total volume. Salt intrusion phenomenon by density current was a little water level change, however, it become a salt wedge type by the much salt invasion during the spring tide and it makes a well-mixed type by the retreating salt wedge during the neap tide. As long as there were some density differences between sea water and fresh water, net upstream flow was existed along the bottom of water way from the estuary to the upstream channel.

  • PDF

Study of Factors for development of Advanced Media filter for Ballast water Treatment (밸러스트 수 처리용 메디아 필터 개발을 위한 여과특성에 관한 연구)

  • Park, Seon-Jeong;Lim, Jae-Dong;Kim, Dong-Geun;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.499-503
    • /
    • 2008
  • As the conference result of MEPC in IMO, development of ballast water management system corresponding to newly established ballast water management standard (D2 regulation) of shipping is being made an active progress over the whole world. The ballast water management system should treat particular material of more than $10{\mu}m$ in high capacity of more than 500t per hour in the event of filtration process. Also, it is very difficult to develop a practical management system since a limited element which a narrow space of the ship should be designed in the minimal volume is assumed. Therefore, the study promoted a study on the next generation auto back wash media filter to overcome such a limited element. Also, the study performed pressure and flux measurement test followed by thickness of each filter medium for filtration by each size to grasp a relation between absorption and pressure at the time of vacuum filtration and mechanical analysis and turbidity change observation of filtered water after vacuum filtration.