• Title/Summary/Keyword: 유동 저항

Search Result 464, Processing Time 0.025 seconds

CFD Analysis on the Continuous and Variable Damping Characteristics of a Semi-Active Shock Absorber (반능동형 충격흡수기의 연속가변 감쇠특성에 대한 CFD 해석)

  • 윤준원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.101-108
    • /
    • 2004
  • Recently, a semi-active shock absorber has been taking interest because of its low cost and simple structure than the active one. CFD analysis has been conducted to investigate the continuous and variable damping characteristics of the semi-active shock absorber. Also, the flow resistance characteristics of a spool valve has been examined to identify individual parameters(namely, exponent and discharge coefficient) of pressure-flow rate relation needed for the accurate valve modeling. The flow field in the damping valve was simulated using the commercial code, CFX-5.3. The numerical results showed reasonable agreement with the experimental outputs. The pressure distribution with the variation of spool opening length and volume flow rate were discussed in detail. And the continuous and variable damping performance was found clearly. The individual parameters of spool valve were obtained as a function of orifice area. The exponent and discharge coefficient were fitted in with the first and the third polynomial respectively.

Analysis of Interrupting Performance for Puffer GCB during the Thermal Failure Period (파퍼식 가스 차단기의 열적 파괴 영역에서의 차단성능 해석)

  • Kim, H.K.;Lee, B.Y.;Park, K.Y.;Park, S.K.;Lee, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.691-693
    • /
    • 2002
  • 본 연구에서는 전류 영점 직전까지의 대전류 구간에서의 열가스 해석을 수행하여, 그 결과와 과도 회복 전압에 따른 아크 후 전류를 계산하여, 아크 후 전류의 0으로의 수렴 여부를 이용하여 열적 파괴 영역에서의 차단성능을 평가한다 아크 후 전류는 유동해석을 통해 구하여진 극간의 온도분포로부터 계산된 아크 저항과 과도인가회복 전압을 이용하여 계산된다.

  • PDF

The characteristics in flow type of helical trim to unclear valve (원자력 밸브용 헬리컬트림의 유동 타입에 따른 특성)

  • Lee, Deok-Gu;Kim, Young-Bum;Yoon, In-Sik;Hwang, Ji-Hyuck;Kwon, Gap-Ju
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3074-3079
    • /
    • 2007
  • The conventional control valves have been used at the locations occurring high differential pressure and high temperature which causes cavitation, flashing, severe vibration due to abrupt flow change, and sudden pressure drop. Previous studies concerning control valves focused to prevent damage of valve trim due to the internal leak and low flow rate. The newly designed helical trim of control valve has been installed at the location of high pressure change and high temperature in a power plant, and operated for evaluation. It is confirmed that the new control valve developed in this study generates flow characteristics in comparison with previous helical trim of control valves.

  • PDF

Linear Proportional Control of Flow Over a Sphere (구 주위 유동의 선형비례제어)

  • Jeon, Seung;Choi, Hae-Cheon
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2753-2756
    • /
    • 2007
  • In the present study, we reduce the drag and lift fluctuations of the sphere by providing a linear proportional control. For this purpose, we measure the radial velocity along the centerline in the wake and provide blowing and suction at a part of sphere surface based on the measured velocity. Zero-net mass flow rate is satisfied during the control. This control is applied to the flow over a sphere at Re=300 and 425. We vary the sensing location at $0.8d{\leq}X_s{\leq}1.3d$ and find that the most effective sensing region coincides with the location at which minimum correlation between the lift and sensing-velocity directions occurs. As a result, the lift and drag fluctuations are significantly reduced.

  • PDF

A Numerical Study of Nonlinear Free-surface Flows Generated by Motions of Two Dimensional Cylinders (2차원 실린더의 운동에 기인한 비선형 자유표면 유동의 수치해석)

  • Lee, Ho-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.85-98
    • /
    • 1998
  • 본 논문의 수치해법은 경계치문제를 풀기 위하여 코시이론(Cauchy's theorem)을 사용하였다. 경계치문제는 완전한 물체표면조건과 자유표면조건을 만족시키는 초기치문제로 귀결된다. 현 수치해법에서 무한영역은 수치계산 영역인 비선형 영역과 선형 자유표면조건을 만족하는 선형영역으로 나누어진다. 선형영역의 해는 과도 그린(Green)함수를 사용하여 정합조건을 부과함으로써, 수치계산은 비선형 영역에서만 수행된다. 본 논문에서 저자는 수치계산 영역에서 코시이론을 사용하여 적분방정식을 도출하였고, 무한영역의 해는 정합면에서 과도 그린함수를 사용하여 표현하였다. 본 수치계산에서 자유표면에 요소 재분배법을 적용함으로써 쇄파현상에 대해서도 안정적인 수치해석을 할 수 있었다. 본 논문에서 개발된 수치방법을 적용한 문제는 다음과 같다. 첫째는 자유표면에서 실린더가 강제동요하는 경우에 자유표면형상과 힘을 계산하여 이전의 실험치 및 계산치와 비교하였다. 두번째로는 실린더가 자유수면하에서 일정한 속도로 항주하는 경우에는 조파저항과 양력을 계산하여 고차 스펙트럴법과 비교하였다.

  • PDF

Fluid Flow Resistance in a Channel with Wire-screen Baffles (와이어 스크린 배플이 설치된 채널에서의 유체유동 저항)

  • Oh, S.K.;Ary, B.K.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.36-41
    • /
    • 2009
  • An experimental investigation was conducted to examine the fluid flow resistance in the rectangular channel with two inclined wire screen baffles. Two different types of wire screens; dutch weave and plain weave, were used as baffle devices in this experiment. Three kinds of baffles with different mesh specifications were made up of dutch type and four different kinds of baffles were made up of plain weave type. The stainless steel wire screen baffles were mounted on the bottom wall with varied angle inclination. Reynolds numbers were varied from 23,000 to 57,000. Results show that the mesh number of baffles plays an important role on friction factor behaviour. It is found that the baffle with the most number of meshes (type SA) has the highest fluid flow resistance.

  • PDF

The Characteristics of Ground Improvement by Thixotropy in the Ground Surrounding by Sand Piles (Sand Pile 설치지반에서 틱소트로피에 의한 지반개량특성)

  • 천병식;여유현
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.1
    • /
    • pp.99-107
    • /
    • 2001
  • 일반적으로 샌드파일 설치로 인해 파일주변지반은 교란되어 스미어 영향과 배수저항에 의해 압밀지연 현상이 발생하는 것으로 알려져 있다. 특히 예민한 점성토 지반일 경우 교란정도가 크며, 틱소트로피현상이 지연될 경우 지지력 및 압축특성은 불리하게 된다. 본 연구에서는 원지반 특성이 파악된 채취시료를 이용하여 완전 교란조건에서의 실내모형시험과, 염분농도변화에 의한 실내역학시험을 실시하였다. 실내모형시험 결과 낮은 하중단계에서의 압밀계수는 비교란 시료의 특성과 유사하게 나타났으며, 염분농도 증가에 따라 일축압출강도가 증가하고 강도회복은 빠르며 압축지수는 작게 나타났다. 결과적으로 점성토지반 간극수중 염분농도는 강도증대와 압축특성 변화에 영향을 주며, 틱소트로피 증대의 영향요소가 적은 담수지반에서 샌드파일을 시공할 경우 발생하는 과다침하의 한 원인으로 여겨지는바, 이와 같은 요인은 측방유동에 의한 침하거동과 함께 고려하여야 할 영향요소로 파악되어야 할 것으로 판단된다.

  • PDF

A Study on the Acoustic Properties of the Reticulated Plastic Foams (플라스틱 폼의 음향특성 조사)

  • 정성수;황철호
    • Journal of KSNVE
    • /
    • v.6 no.3
    • /
    • pp.333-339
    • /
    • 1996
  • The absorption coefficients of 3 largely reticulated urethan foams are measured by transfer function method which uses two microphones in an impedance tube. Based on the previously published data, the new modified empirical equations for predicting the characteristic impedance and propagation constant of the largely reticulated urethane foams are developed. Comparison is made between the measured data and the predicted data, based on the previously published equations and the new equation. Good agreement of the absorption coefficient between the measured and predicted data by the new modified empirical equation has been obtained.

  • PDF

Smooth Rotating Gate (완충회전수문)

  • Yoo, Dong-Hoon;Lee, Tae-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1118-1122
    • /
    • 2005
  • 수중보는 하천, 하수관 또는 인공수로에 건기시 유지수량을 확보할 목적으로 설치되며 제한 범위 이상의 물이 유입되는 경우 원활한 치수를 위하여 이를 자동적으로 방출시키도록 자동으로 수문을 개폐시키는 장치가 필요하다. 보통 10년 주기 내외의 평균 강우량에 맞추어서 그 용량이 결정되어야 경제성을 확보할 수 있게 된다. 그러나 10년 주기의 평균 강우량을 초과하는 강우가 발생할 경우에 유입되는 전체 수량을 유입시키면 해당 기기에 상당한 손상을 입히게 된다. 또한 재현기간을 너무 길게 잡을 경우, 해당 수처리의 설치비용이 과다하게 되고, 경제성이 낮아질 수 밖에 없다. 따라서 수처리를 위한 장치의 규모는 적정한 재현기간에 맞추어 설계하고, 재현기간을 초과하여 강우가 발생할 경우 강우 유입을 우회시킬 필요가 있게 된다. 이와 같이 수량을 우회 또는 통과시킬 목적으로 초과유량을 방출할 수 있는 완충회전수문 실험 모형을 제작하여 여러 차례의 실험을 토대로 한계수심 및 충격량을 이론적으로 산정하였다.

  • PDF

Flow Characteristics in a Clean Room after Divisional Filter Exchange (부분적인 필터교체에 따른 청정실내부의 유동특성)

  • 이재헌;박명식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.8
    • /
    • pp.2110-2121
    • /
    • 1993
  • A numerical investigation has been carried out for the flow characteristics after exchange of some filters from the original layer to the new low pressure loss layer with equal filtering efficiency. The solution domain includes upper plenum, filter layer, clean space, access panels, and lower plenum. The concept of the distributed pressure resistance was applied to describe the momentum loss in filter layer and access panels. The evolution of the flow field is simulated using the low Reynolds number k-.epsilon. over bar turbulent model and SIMPLE algorithm based on the finite volume method. As a result, after the exchange of filter layer the power requirement can be reduced by 8-9 percent. The results also demonstrate that the perpendicularity of the flow near access panels may become worse at new filter layer than origianl filter layer. But the situation can be recovered by adjusting the jopening ratio of access panels.