• Title/Summary/Keyword: 유동 비정상성

Search Result 288, Processing Time 0.032 seconds

Premixture Composition Optimization for the Ram Accelerator Performance Enhancement (램 가속기 성능 향상을 위한 예 혼합기 조성비 최적화에 관한 연구)

  • 전용희;이재우;변영환
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.4 no.2
    • /
    • pp.21-30
    • /
    • 2000
  • Numerical design optimization techniques are implemented for the improvement of the ram accelerator performance. The design object is to find the minimum ram tube length required to accelerate projectile from initial velocity $V_o$ to target velocity $V_e$. The premixture is composed of $H_2$, $O_2$, $N_2$ and the mole numbers of these species are selected as design variables. The objective function and the constraints are linearized during the optimization process and gradient-based Simplex method and SLP(Sequential Linear Programming) have been employed. With the assumption of two dimensional inviscid flow for internal flow field, the analyses of the nonequilibrium chemical reactions for 8 steps 7 species have been performed. To determined the tube length, ram tube internal flow field is assumed to be in a quasi-steady state and the flow velocity is divided into several subregions with equal interval. Hence the thrust coefficients and accelerations for corresponding subregions are obtained and integrated for the whole velocity region. With the proposed design optimization techniques, the total ram tube length had been reduced 19% within 7 design iterations. This optimization procedure can be directly applied to the multi-stage, multi-premixture ram accelerator design optimization problems.

  • PDF

Flow and Thermal Analyses of Internet Data Center for Embodiment in Green IT (공공부문 전력절감과 그린IT구현을 위한 데이터센터 내 열유동해석)

  • Park, Sang-Lin;Shim, Jang-Sup;Song, Jong-Choul;Moon, Byong-Joo;Park, Kyoung-Woo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.243-246
    • /
    • 2010
  • 최근 정보량의 급격한 증가로 데이터센터는 점차 대형화되고 있으며, 통합적으로 관리/운영되기 위해서는 전산실내 적절한 온도와 습도의 유지가 필수적이므로, 전산실내 에너지의 사용 효율을 극대화하기 위한 연구가 꾸준히 이루어지고 있다. 이 연구에서는 국내 공공부문의 대형 전산실을 모델로 선정하여 전산실 내 서버의 위치, 용량 그리고 냉각시스템 등을 고려하여 전산실내 열/유동특성을 수치적으로 규명함으로써, 에너지 효율 극대화를 추구하고 전력을 절감하여 저탄소 녹색성장과 그린IT 환경을 구축 하고자 한다. 이를 위하여 실제 측정한 환경 데이터를 바탕으로 전산유체역학(CFD)을 이용하여 3차원 비압축성, 정상상태의 열/유동특성을 예측한다. 또한 기존 및 개선된 전산실에 대한 비교결과를 바탕으로 새로운 열/유동조건을 도출하며, 이를 통하여 전산실 운영에 필요한 에너지 효율향상 방안을 제안하고자 한다. 연구 결과, 전산실 천장의 냉기유입부분과 열기배출부분으로 나뉘어 냉복도와 온복도를 형성하며, 내부 서버와 기타 각종 장비들의 발열 등으로 부분적인 열섬(Thermal island)현상이 나타났다. 이러한 열섬현상을 줄이고, 전산실내 환경을 최적화하기 위하여 찬공기 유입부분의 속도, 배출구의 유량, 그리고 냉/온 복도의 역할 변경 등 여러 가지 가능한 매개변수에 대한 연구가 필수적이다. 또한, 서버에서 발생한 고온의 공기를 배출하는 것이 전산실 내 적절한 온도구현에 효과적이며, 열섬현상을 방지하기 위해서는 이 부분에 차가운 공기의 유입이 필요하다는 것을 알 수 있었다.

Uncertainty Analysis of the Optical Smoke Density Measurement through the Doorway in a Compartment Fire (구획화재의 출입구를 통한 광학적 연기밀도 측정의 불확실성 해석)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.75-79
    • /
    • 2013
  • The present study measured the light transmission to quantify the smoke density(smoke mass concentration) through the doorway in a compartment fire and performed the uncertainty analysis to evaluate the reliability of the measurement technique. The optical light extinction method based on Bourguer's law was applied to estimate the smoke density of doorway exhausting smoke flow in upper layer of a compartment for methane gas fires. The measurement uncertainty of the light extinction measurement was evaluated for the light transmittance, path length, and specific mass extinction coefficient and the expanded uncertainty was estimated about 20% with confidence level of 95%. The mean smoke density through the doorway for the methane fire was calculated for quasi-steady fire and the smoke density linearly increased as the GER increased.

Introduction of Numerical Simulation Techniques for High-Frequency Combustion Instabilities (고주파 연소불안정 예측을 위한 해석기술 개발 사례)

  • Kim, Seong-Ku;Joh, Miok;Han, Sanghoon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.68-77
    • /
    • 2017
  • High-frequency combustion instability results from a feedback coupling between the unsteady heat release rate and the acoustic waves formed resonantly in the combustion chamber. It can be modeled as thermoacoustic problems with various degrees of the assumptions and simplifications. This paper presents numerical analysis of self-excited combustion instabilities in a variable-length lean-premixed combustor and designs of passive control devices such as baffle and acoustic resonators in a framework of 3-D FEM Helmholtz solver. Nonlinear behaviors such as steep-fronted shock waves and a finite amplitude limit cycle are also investigated with a compressible flow simulation technique.

  • PDF

Prediction of Pitch and Roll Dynamic Derivatives for Flight Vehicle using CFD (전산유체역학을 이용한 비행체의 피치와 롤 동안정 미계수 예측)

  • Lee, Hyung-Ro;Gong, Hyo-Joon;Kim, Beom-Soo;Lee, Seung-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.5
    • /
    • pp.395-404
    • /
    • 2012
  • This paper presents computations of the dynamic derivatives of three dimensional flight vehicle configurations using CFD. The pitch dynamic derivatives are computed from the pitch sinusoidal motion, while the roll damping is computed based on steady state calculation using a non-inertial frame method. The Basic Finner and the SDM(Standard Dynamic Model) are chosen for the benchmark tests against other numerical and experimental results. For the flow calculations, a 3-D Euler solver that can be run both on the non-inertial frame and on the inertial frame is developed. A dual-time stepping method is applied for the unsteady time accurate simulations. A good agreement of pitch-roll dynamic derivatives with previously published numerical results and the experimental results is observed.

The Power Spectral Density Characteristics of Lift and Drag Fluctuation of Fin Tube in a Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.23-29
    • /
    • 2016
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift and drag fluctuation over the fin tube was investigated. The derived nondimensional lift PSD was compared with the results of the previous experimental studies and the characteristics of lift and drag PSD over a single fin tube was established from the present CFD study.

A Study on the Characteristics of Lift and Drag Fluctuation Power Spectral Density in a Heat Exchanger Tube Array (전열관군에서 양력과 항력 변동의 PSD 특성 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.712-718
    • /
    • 2016
  • A heat exchanger tube array in a heat recovery steam generator is exposed to hot exhaust gas flow that can cause flow induced vibrations, which could damage the heat exchanger tube array. The characteristics of flow induced vibration in the tube array need to be established for the structural safe operation of a heat exchanger. Several studies of the flow induced vibrations of typical heat exchangers have been conducted and the nondimensional PSD (Power Spectral Density) function with the Strouhal number, fD/U, had been derived using an experimental method. The present study examined the results of the previous experimental research on the nondimensional PSD characteristics by CFD analysis and the basis for the application of flow induced vibration to the heat recovery steam generator tube array was determined from the present CFD analysis. The present CFD analysis introduced circular cylinder tube array and calculated using unsteady laminar flow for the tube array. The characteristics of lift and drag fluctuations over the cylinder tube array was investigated. The derived nondimensional lift and drag PSD was compared with the results of the previous experimental research and the characteristics of lift and drag PSD for a circular cylinder tube array was established from the present CFD study.

Head Posture-Induced Phoria Deviation (머리 위치에 따른 사위도의 변화)

  • Ha, Eun-Mi;Son, Jeong-Sik;Moon, Byeong-Yeon;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate how phoria variations would vary with head positions, as well as to review the need to differentiate prism placement over either eye in a relation to the imbalance of the extraocular muscle. Methods: This study was carried out with 44 males (88 eyes) and 16 females (32 eyes) aged between 20 and 30. For all subjects, testings were performed using cover test, subjective refraction, phoria and vergence test. To analyze phoria variations comparatively for the head tilt test and the face turn test, phoria deviation were measured using the von Graefe. Results: For the phoria variation related with head tilt and face turn, a significant difference was observed in the group judged to be abnormal on the horizontal phoria of Morgan' norm (p<0.05); especially in patients who needed near prescription of Sheard's criterion, a higher variation was observed (p<0.05). The abnormal group was composed of patients who needed distance prescription of Sheard's criterion and ones who did not need the prescription, all of whom showed phoria variations, but the mean value was less than the near. Conclusions: With regard to the head tilt and face turn related phoria level, the patients who needed near horizontal prism prescription of Sheard's criterion showed a remarkably higher variation. Altogether, it is deemed to check whether extraocular muscles are ill-balanced in both eyes previously to determine the prism power on phoria level to the end that each of prism powers may be accurately determined.

Hydraulic Characteristics of Anaerobic Fluidized Bed Bioreactor (혐기성 유동상 반응기의 수리학적 특성)

  • Seok, Jong-Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.90-96
    • /
    • 2018
  • Tracer experiments were carried out on two laboratory modes, "without media mode" and "with media mode", to examine the hydraulic characteristics of the anaerobic fluidized bed bioreactor (AFBR). For both configurations, a formula was derived for the hydraulics and data interpretation to obtain the actual characteristics of the reactor. The dispersion model is based on the assumption that carriers are non-reacting and the dispersion coefficient is constant. The model represents the one-dimensional unsteady-state concentration distribution of the non-reacting tracer in the reactors. The experimental results showed that the media increased the mixing conditions in the reactor considerably. For the reactor without media, in the range tested, the dispersion coefficient was at least an order of magnitude smaller than that of the reactor with media. Advective transport dominates and the flow pattern approaches the plug flow reactor (PFR) regime. The dispersion coefficient increased significantly as us, the superficial liquid velocity, was increased proportionally to 0.82cm/s. On the other hand, for the reactor with media, the flow pattern was in between a PFR and a completely mixed flow reactor (CMFR) regime, and the dispersion coefficient was saturated at us=0.41cm/s, remaining relatively constant, even at us=0.82cm/s. The dispersion coefficient depends strongly on the liquid Reynolds number (Re) or the particle Reynolds number (Rep) over the range tested.

Prediction of Hydraulic Performance of a Scaled-Down Model of SMART Reactor Coolant Pump (스마트 원자로냉각재펌프의 축소모형에 대한 수력성능 예측)

  • Kwon, Sun-Guk;Park, Jin-Seok;Yu, Je-Yong;Lee, Won-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1059-1065
    • /
    • 2010
  • An analysis was conducted to predict the hydraulic performance of a reactor coolant pump (RCP) of SMART at the off-design as well as design points. In order to reduce the analysis time efficiently, a single passage containing an impeller and a diffuser was considered as the computational domain. A stage scheme was used to perform a circumferential averaging of the flux on the impeller-diffuser interface. The pressure difference between the inlet and outlet of the pump was determined and was used to compute the head, efficiency, and break horse power (BHP) of a scaled-down model under conditions of steady-state incompressible flow. The predicted curves of the hydraulic performance of an RCP were similar to the typical characteristic curves of a conventional mixed-flow pump. The complex internal fluid flow of a pump, including the internal recirculation loss due to reverse flow, was observed at a low flow rate.