• Title/Summary/Keyword: 유동 급팽창

Search Result 6, Processing Time 0.284 seconds

An Experimental Study on Swirling Flow in a Sudden Expansion Tube using 3D PIV Technique (3D PIV 기법을 이용한 선회유동의 급팽창에 관한 실험적 연구)

  • Chang, Tae-Hyun;Kil, Sang-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.272-281
    • /
    • 2009
  • The effect of swirl on the flow characteristics in a sudden expansion tube was examined experimentally by using 3D PIV(particle image velocimetry) to capture the velocity profiles. The swirling flow of water through a sudden 1:2 axisymmetric expansion has previously been studied experimentally within a horizontal round tube. A kind of tangential slot is used as a swirl generator for swirling flow and a honey comb is used for without swirl flow. The work with the swirl and without swirl results are compared to each other at the same Reynolds number. Liquid crystal was employed to measure temperature profiles and heating coil used for heat transfer with and without swirl flow. And then the Nusselt number ratoes(Nu/Nudb) are calculated along the test section.

An Experimental Study of the Swiriling Flow and Heat Transfer Downstream of an Abrupt Explansion in a Circular Pipe with Uniform Heat Flux (선회류를 동반한 급확대 원관내에서의 열전달 특성에 관한 실험적 연구)

  • 권기린;장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.94-101
    • /
    • 1994
  • 실험 데이터는 급확대비 3:1 팽창의 시험관에서의 실험결과를 나타내고 있으며, 실험에 이용된 동작유체로써는 공기가 사용되었다. 입구관에서 레이놀즈수는 60,000으로부터 120,000까지 변하게 하였고, 스월강도는 0으로부터 16까지 변화되게 하였다. 균일한 열 플럭스 경계조건이 사용되었는데, 그 결과 관벽온도 및 체적온도는 24$^{\circ}C$로부터 71$^{\circ}C$까지에 걸쳐 나타났다. 플롯상에 국소 Nusselt수는 최대 열전달점에서 정점을 이루는 모습을 보여 주고 있다. 스월강도가 0으로부터 최대값으로 증가 되었을때, 최고 Nusselt수의 위치는 시험관에서 4로부터 1스텝 하이트로 변경되는 것이 조사되었다. 이러한 최대 Nusselt수의 상류부 이동은 완전 발달된 유동에서의 값보다 2.2배에서 8.8배나 많은 그의 크기를 증가시킨다고 할 수 있다.

  • PDF

Supersonic Mach Disk Characteristics in a Plasma Wind Tunnel (플라즈마 풍동의 초음속 마하 디스크 특성)

  • Chinnaraj, Rajesh Kumar;Oh, Philyong;Choi, Seongman
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.1
    • /
    • pp.61-70
    • /
    • 2019
  • A primary investigation on the underexpanded flow generated in a 0.4 MW class high enthalpy supersonic arc-heated plasma wind tunnel is conducted experimentally. The diameter and the position of the Mach disk from the nozzle exit is measured for overall pressure ratios ranging from 200 to 30. The empirical correlations for Mach disk diameter and position are determined which show very good agreement with experimental results.

Experimental Analysis of a Supersonic Plasma Wind Tunnel Using a Segmented Arc Heater with the Power Level of 0.4 MW (0.4 MW 급 분절형 아크 히터를 이용한 초음속 플라즈마 풍동 특성 실험)

  • Kim, Min-Ho;Lee, Mi-Yeon;Kim, Jeong-Soo;Choi, Chea-Hong;Seo, Jun-Ho;Moon, Se-Yeon;Hong, Bong-Guen
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.700-707
    • /
    • 2013
  • Experimental analyses on a supersonic plasma wind tunnel of CBNU (Chonbuk National University) were carried out. In these experiments, a segmented arc heater was employed as a plasma source and operated at the gas flow rates of 16.3 g/s and the total currents of 300 A. The input power reached ~350 kW with the torch efficiency of 51.4 %, which is defined as the ratio of total exit enthalpy to the input power. The pressure of plasma gas in the arc heater was measured up to 4 bar while it was down to ~45 mbar in a vacuum chamber through a Laval nozzle. During this conversion process, the generated supersonic plasma was expected to have a total enthalpy of ~11 MJ/kg from the measured input power and torch efficiency. In addition to the measurement of total enthalpy, a cone type probe was inserted into the supersonic plasma flow in order to estimate the angle between shock layer and surface of the probe. From these measurements, the temperature and the Mach number of the supersonic plasma were predicted as ~2,950 K and ~3.7, respectively.

Performance analysis of a cold-air forced circulation type showcase (냉기 강제순환형 공랭식 쇼케이스 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1003-1010
    • /
    • 2013
  • In this study, a simulation program was developed, which predicts the performance of cold-air forced circulation type air cooled showcase. The showcase has an excellent display effect in addition to preserving the grocery. In the program, the compressor was analyzed using performance data supplied by the manufacturer and the capillary tube pressure drop was analyzed using a homogeneous model. The evaporator and condenser were analyzed by dividing the heat exchangers into small elements, where energy balance and appropriate heat transfer correlations were used. A showcase model with two 3/4 HP compressors, capillary tubes of 1.6 mm inner diameter, a fin-and-tube evaporator and condenser was tested, and the results are compared with the predicted values. It is shown that both evaporation and condensation temperatures are adequately predicted by the program.

The Newest Technology Development and Commercialization Status of Coal Gasification (석탄가스화 기술의 최신 개발 동향 및 상업화 현황)

  • Lee, Jin-Wook;Yun, Yongseung;Kang, Won-seok
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.150-163
    • /
    • 2015
  • Gasification technology is one of the representative next-generation fossil fuel utilization technologies, converting low grade fossil fuels such as coal, heavy residue oil, pet-coke into highly clean and efficient energy sources. Accordingly, related market demand for gasification technology is ever increasing steadily and rapidly. A few years ago, conventional pulverized coal utilization technology had an edge over the gasification technology but the most significant technical barrier of limited capacity and availability has been largely overcome nowadays. Futhermore, it will be more competitive in the future with the advancement of related technologies such as gas turbine, ion transfer membrane and so on. China has recently completed a commercialization-capable large-scale coal gasification technology for its domestic market expansion and foreign export, rapidly becoming a newcomer in the field and competing with existing US and EU technical leadership at comparable terms. Techno-economic aspect deserves intensive attention and steady R&D efforts need to continue in organized, considering that gasification technology is quite attractive combined with $CO_2$ capture process and coal to SNG plant is economically viable in Korea where natural gas is very expensive. In the present paper, recent technology development and commercialization trend of many leading companies with coal gasification expertise have been reviewed with significant portion of literature cited from the recently held '2014 Gasification Technology Conference'.