• 제목/요약/키워드: 유동차단 영역

검색결과 19건 처리시간 0.027초

다익 팬/스크롤 시스템의 로터 내부 유동 특성에 관한 실험적 연구 (An Experimental Study for Flow Characteristics Inside the Rotor of a Multiblade Fan/Scroll System)

  • 맹주성;윤준용;안태범;윤종은;한덕전
    • 대한기계학회논문집B
    • /
    • 제23권5호
    • /
    • pp.646-652
    • /
    • 1999
  • Detailed characteristics of the mean flow field inside the rotor of a multiblade fan with scroll are presented in this paper by measurements and visualizations. The measurements were taken with a five-hole probe and conformed by smoke test. How field is distinguished clearly in 3 regions with respect to the flow directions. The first region is near the exit of scroll where the fluid flows the opposite direction to the rotation of rotor. The second is opposite side of the scroll exit where the fluid flows the same direction to the rotation of rotor. The third is the region where the fluid flows toward the blades directly with the largest values comparatively. The strongest recirculation is happened in the second region, and the weakest one is in the third region. This complex configuration makes the flow field highly non-uniform and may cause to generate a noise and ineffective flow efficiency.

영상분석을 이용한 기포유동특성 실험 (Experimental Study on Characteristics Air Bubble Flow Using the Image Analysis)

  • 김성중;장창래
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.317-317
    • /
    • 2023
  • 수자원의 확보와 어류 서식 환경보전이라는 두 가지 측면은 수자원 이용이라는 목적하에 합의되기 어려운 문제를 가지고 있다. 점차적으로 수자원이 고갈되는 현시점에 효율적 물관리를 위해 최근에는 단절된 하천을 연결하기 위한 기술들이 개발되고 있으며, 이중 안정적인 물공급 시스템을 구축하기 위한 수중터널이 그러한 기술 중 하나이다. 수자원의 확보 측면에서는 의미가 있는 방법일 수 있으나 물리적으로 동떨어져 있던 서로 다른 환경을 연결하는 문제로 인한 부작용이 발생하는데 이중 외래어종 유입으로 인한 수중생물의 환경변화가 가장 큰 문제로 대두되고 있다. 이러한 문제를 방지하기 위해 어류의 이동을 차단하는 기술 또한 개발되고 있으며 그물망, 버블스크린, 빛, 소리를 이용한 다양한 방법을 통해 어류의 접근을 방지하고자 노력하고 있다. 본 연구에서는 이러한 차단시설 중 기포를 이용한 버블스크린과 관련하여 효율성을 높이기 위한 방법을 모색하고자 실제 버블의 상승속도에 영향을 미치는 여러 가지 불확실성 인자들에 대한 상관성과 인과관계를 검토하고자 하였다. 이를 위해서 외부적 원인에 대한 오차요소를 확인하고 결과값에 영향을 미치는 여러 가지 변수에 대하여 검토하고자 하는 실험연구를 수행하였다. 버블실험을 위한 수로는 길이 15m, 폭 1.5m 의 제원을 가지는 직선수로에서 수행하였으며, 버블 발생을 위한 튜브는 PVC 재질이며, 5cm 간격으로 1mm 직경을 갖는 파이프를 제작하여 활용하였다. 실험의 분석은 이미지를 이용한 방법을 사용하였으며 분석위치 및 버블사이즈 그리고 해석격자 크기에 대한 상관분석 및 회귀분석을 통해 각각 인자들과의 관계를 규명하고자 하였다.

  • PDF

신경망 최적화 기법을 이용한 다익 홴/스크롤 시스템의 설부에 대한 형상 최적화 (Shape Optimization of Cut-Off in a Multi-blade Fan/Scroll System Using Neural Network)

  • 한석영;맹주성;유달현;진경욱
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1341-1347
    • /
    • 2002
  • In order to improve efficiency of a system with three-dimensional flow characteristics, this paper presents a new method that overcomes three-dimensional effects by using two-dimensional CFD and neural network. The method was applied to shape optimization of cut-off in a multi-blade fan/scroll system. As the entrance conditions of two-dimensional CFD, the experimental values at the positions out of the inactive zone were used. The distributions of velocity and pressure obtained by two-dimensional CFD were compared with those of three-dimensional CFD and experimental results. It was found that the distributions of velocity and pressure have qualitative similarity. The results of two-dimensional CFD were used for teaming as target values of neural network. The optimal angle and radius of cut-off were determined as 71$^{\circ}$and 0.092 times the outer diameter of impeller, respectively. It is quantified in the previous report that the optimal angle and radius of cut-off are approximately 72$^{\circ}$and 0.08 times the outer diameter of impeller, respectively.

반응표면법을 이용한 다익 홴/스크롤 시스템의 설부에 대한 형상 최적화 (Shape Optimization of Cut-Off in a Multi-blade Fan/Scroll System Using Response Surface Method)

  • 한석영;맹주성;황영민
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.225-231
    • /
    • 2003
  • In order to improve efficiency of a system with three-dimensional flow characteristics, this paper presents a new method that overcomes three-dimensional effects by using two-dimensional CFD and response surface method. The method was applied to shape optimization of cut-off in a multi-blade fan/scroll system. As the entrance conditions of two-dimensional CFD, the experimental values at the positions out of the inactive zone were used. In order to examine the validity of the two-dimensional CFD the distributions of velocity and pressure obtained by two-dimensional CFD were compared with those of three-dimensional CFD and experimental results. It was found that the distributions of velocity and pressure show qualitatively similarity. The results of two-dimensional CFD were used for constructing the objective function with design variables using response surface method. The optimal angle and radius of cut-off were determined as $72.4^{\circ}$ and 0.092 times the outer diameter of impeller, respectively. It is quantified the previous report that the optimal angle and radius of cut-off are approximately $72^{\circ}$ and 0.08 times the outer diameter of impeller, respectively.

$SF_6$ 차단기의 열가스 수치해석 (Numerical Analysis of Arcs in SF6 Gas Circuit Breaker)

  • 배채윤;김홍규;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.816-818
    • /
    • 2000
  • 본 논문에서는 $SF_6$ 차단기 내의 대전류 아크에 대한 수치적인 해석을 모의하는 도구를 제시한다. 대전류의 차단을 위해서 해석을 통해 열적 파괴를 예측하는 것이 필수적이다. 본 논문에서 사용한 방법은 FVFLIC(finite volume fluid in cells)이며 지배방정식은 압축성 오일러 방정식으로 아크와 유동의 상호 작용을 해석한다. 아크는 기본적으로 에너지 보존식에서 열소스항으로 나타나며 주울열과 복사항으로 표현된다. 주울열은 플라즈마 영역내의 전계해석을 통해 계산되며 복사항은 방출과 흡수항의 합으로 나타내어지고 이것은 국소적인 온도와 압력의 함수이다. 본 논문에서는 수정된 방출과 흡수 모델로 복사 열전달을 계산하였다.

  • PDF

폐광 부지의 재해 및 오염대 조사관련 물리탐사자료의 고찰 (Case Studies of Geophysical Mapping of Hazard and Contaminated Zones in Abandoned Mine Lands)

  • 심민섭;주현태;김관수;김지수
    • 지질공학
    • /
    • 제24권4호
    • /
    • pp.525-534
    • /
    • 2014
  • 폐광 부지에서 발생하는 대표적인 환경 문제는 산성으로 오염된 지표수와 지하수, 적재된 폐광석 및 광미, 채굴 활동으로 야기된 지반침하 현상을 들 수 있다. 이 논문은 광해 유형에 따라 재해 및 오염영역을 효율적으로 탐지했던 지구물리탐사방법들을 고찰하는데 있다. 시험 자료로서 토양오염, 산성광산배수, 지반침하, 인공차수막 파손 및 광미/폐광석 적치장을 각각 대표하는 네 개의 폐광 부지를 선택하였다. 자료 검증을 위해 물리탐사자료는 자료의 유형에 따라 시추자료(코어 샘플, 물리검층, 토모그래피 등)와 물 자료(수소이온농도, 전기전도도, 중금속원소 등)와 비교하였다. 토양오염 탐지에 있어서 낮은 전기비저항 이상대는 특히 구리, 납, 아연의 중금속 농도가 높은 지역과 부합된다. 산성광산배수의 유동 경로는 자연전위 곡선에서 음의 전위 이상대, 전기비저항자료에서의 저비저항 이상대, 지하레이더 자료에서의 얕은 투과깊이 영역으로 탐지되었다. 채굴적은 전기비저항 단면에서의 저비저항 이상대, 탄성파토모그래피에서 낮은 속도 영역, 물리검층곡선의 복합해석으로 특징되며, 정확한 위치는 코어자료와 시추공영상자료에서 잘 확인되었다. 침출수 유동을 차단하기 위해 설치된 인공차수막의 파손 구간은 전기비저항 자료에서의 국부적인 이상대로 정확히 탐지되며 매립된 폐석더미는 고비저항 이상대와 저속도 이상대로 특징된다.

화력발전소 터빈 본관의 환풍기 위치 및 용량 최적화에 관한 연구 (A Study on the Optimization of Ventilation Fan Position and Flow Rate for a Turbine Building of a Power Plant)

  • 김태권;하지수;박찬혁
    • 에너지공학
    • /
    • 제25권2호
    • /
    • pp.86-93
    • /
    • 2016
  • 화력발전소 터빈 본관 내부는 고온의 스팀 배관, 탈기기, 스팀 저장 탱크, 수증기 차단 밸브 등의 존재로 터빈 본관 작업 공간의 공기가 고온으로 올라가서 작업자가 장시간 작업하기 곤란한 경우가 발생한다. 터빈 빌딩 작업공간의 공기를 냉각하기 위해 터빈 빌딩 창문을 개방하여 외부의 찬 공기로 냉각하고 상부에 환풍기를 설치하여 외부로 배출한다. 이렇게 한 경우에도 국부적으로 고온의 영역이 존재하여 작업 공간의 냉각을 위한 추가적인 환풍기 설치가 필요하고, 이 경우 환풍기의 위치와 유량에 대한 최적화가 필요하다. 본 연구는 여러 가지 경우의 열 유동 해석을 통해 쾌적한 작업환경을 위한 추가적인 환풍기의 위치와 용량을 최적화한 방안을 제시 하는 것을 목적으로 하였다. 본 연구를 통해 기존 환풍기 위치와 용량을 기준으로 터빈 본관 내부의 고온 영역인 탈기기 영역근처의 열원을 배출하는 환풍기를 추가로 설치하는 것이 전체온도를 $3.0^{\circ}C$, 가장 고온의 영역인 탈기기영역의 온도를 $4.2^{\circ}C$ 저감할 수 있었다.

지능형 비디오 감시를 위한 능동적 객체 추적 시스템 (Active Object Tracking System for Intelligent Video Surveillance)

  • 박호식
    • 한국정보전자통신기술학회논문지
    • /
    • 제7권2호
    • /
    • pp.82-85
    • /
    • 2014
  • 지능형 영상 감시 시스템은 감시카메라의 영상정보를 디지털화 하여 시스템이 스스로 사물의 위치 및 패턴을 분석하고 위험 상황이 발생할 경우 경보 및 출입 차단 시스템을 작동하여 보안담당자에게 즉각 현황을 알려 사람의 관리로 인해 발생하는 취약점을 대체, 보완 할 수 있게 해준다. 그러나 원거리 화면에서에서 작은 객체를 확대하기 위해서는 객체 위치에 따른 정확한 확대 배율과 중심좌표 이동이 이루어져야 한다. 그래서 본 논문에서는 유동적 배경에서 객체 이동에 따른 Pan, Tilt 좌표와 확대 배율을 연산하여 객체가 근거리 혹은 원거리 어디에 있듯 일정한 크기의 객체를 추적할 수 있도록 하고자 하였다. 실험결과 카메라의 정확한 PTZ 제어를 위하여 무게 중심을 검출하여 제어한 결과, 거리에 따라 최소 94%~100%의 정확한 제어가 가능하여 객체의 주요 영역을 인식 및 추적할 수 있었다.

초음속 2차원 2단 혼합층에서 중간층의 역할 (A Study on the Effect of Mid Layer on Supersonic 2D Double Shear Layer)

  • 김동민;백승욱
    • 한국추진공학회지
    • /
    • 제19권1호
    • /
    • pp.9-17
    • /
    • 2015
  • 기본 유동 형상은 상대적으로 얇은 중간층이 연료와 공기 사이에 끼어있는 평행 2단 혼합층으로 구성되어 있다. 본 연구는 중간층의 두께 변화에 따른 연소 향상을 수치해석을 통해 조사하였다. 이 경우에, 난류 혼합층에서 열 방출에 의한 효과가 중요하다. 수치해석을 수행하기 위해 완전 보존적인 비정상 2차 시간 정확도의 하부 반복 기법과 2차 총 변화 억제 기법을 k-${\omega}$ 전단응력이동 모델이 결합된 유한체적법과 함께 사용하였다. 다음과 같이 3개의 경우에 대해 해석을 수행하였다. 연료와 공기로 구성된 단일 혼합층, 연료와 공기 사이에 불활성 기체층이 끼어있는 2단 혼합층, 그리고 연료와 공기 사이에 차가운 연료층이 끼어있는 2단 혼합층. 수치해석은 중간 기체층이 1, 2, 4 mm 인 경우에 대하여 수행되었다. 기체층의 총 두께는 4 cm이다. 불활성기체층이 2, 4 mm인 경우와 저온의 연료층이 4 mm인 경우에 단일 혼합층의 경우보다 연소영역이 확대된다.