• Title/Summary/Keyword: 유동유속

Search Result 936, Processing Time 0.039 seconds

Survey of ICT Apply to Plastic Greenhouse, Rack·Pinion Adaption to Single Span and CFD Analysis (온실 ICT융복합 실태조사와 복숭아형 랙피니언천창 적용 단동온실 및 CFD 유동해석)

  • Cho, Kyu Jeong;Kim, Ki Young;Yang, Won Mo
    • Journal of Bio-Environment Control
    • /
    • v.24 no.4
    • /
    • pp.308-316
    • /
    • 2015
  • This study was conducted to investigate the situation of ICT apply to plastic greenhouse, and the results be apply to design of new one. A CFD analysis were conducted to monitering the ventilation and energy saving of the single span greenhouse newly designed. The causes of delay to apply ICT to plastic greenhouse are the high cost for installation(24%), insufficiency of after services(19%), often disorder(16%), unskillful management of soft ware(15%), insufficient ICT efficiency(13%) and unsatisfying of income increase(12%). The parts of problem occurred in ICT plastic greenhouse are the structure, actuator, environmental control system and sensor(approximate 14%, respectively), remote control technique(13%), plant management technique(12%), energy saving technique(10%) and utilization of software(8%). In the condition of lateral window closed, the average wind speed changed to slow, but it was faster in the condition of leeward side window opened than in the condition of lee and winward side window opened. The air movement in the condition of lateral window closed occur by air moving fan not by out air. It is not affect the room temperature but effective the uniformity of room temperature. The average temperature of low height greenhouse was uniform than high height one. The average temperature in condition of 3rd curtain opened become same with outside temperature after 2 hours, but take more 5 hours in condition of 3rd curtain closed.

Groundwater Flow Analysis Using Finite Difference Method in Volcanic Island (화산도서에서 유한차분법을 이용한 지하수 유동해석)

  • Choe, Yun-Yeong;Lee, Sun-Tak
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.5
    • /
    • pp.611-622
    • /
    • 2000
  • In this study, MODFLOW model is used to analyze the groundwater flow system of Seoguipo area in Cheju island, The final parameters of permeability coefficient and storage coefficient of target area can be obtained by trial and error method using the measured data of pumping rate as initial values. And it is found that the applicability for groundwater flow system is reflected well from the simulation result of the model. Seoguipo area spring water is thought to appear by relatively stable groundwater recharge below EL. 400m according to head distribution through the analysis of observed data considering topographic and geological characteristics, Lee's study(996), and the simulation result. Also it is known that point II, III, and VI show relatively large velocity vectors, and groundwater flows through the movement path which is distributed in various directions of I, II, III, IV, V, VI, and VIl form the result of velocity vector analysis using head distribution result values to analyze the groundwater flow path under unsteady flow condition.dition.

  • PDF

A Study on the Flow Characteristics according to the Change of Structure in Filtration Using the Numerical Model (수치모형을 이용한 여과기 내 구조 변경에 따른 유동특성 연구)

  • Kim, Taewon;Song, Sooho;Choi, Changhyung;Park, Youngjin;Kim, Jiho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.285-285
    • /
    • 2017
  • 최근 전 세계적으로 심각해지는 물 부족 현상과 수질오염으로 대량의 원수를 빠른 시간 내에 여과하기 위한 여과장치의 개발 및 효율성 향상을 위한 연구의 필요성이 증가되고 있다. 특히 여과필터의 내부구조에 의해 유동이 편중되는 현상이 발생하면 여과효율 및 여과필터 유지관리에 문제가 발생되기 때문에 최적의 여과필터를 설계하는 것이 중요하다. 이에 본 연구에서는 수리모형실험으로 검토하기에 어려움이 있는 여과기 내부구조에 대한 유동특성을 수치해석을 이용하여 검토하였다. 수치해석은 유한요소법 기반의 수치모형으로 여과기 내부를 상세하게 모의할 수 없기 때문에 유한체적법 기반인 ANSYS CFX 모형을 이용하였다. 여과기 내 여과필터는 두께 2.0 mm, 공극율 25%로 가정하고 다공성 기법(porous media)을 적용하였다. 검토를 위한 경계조건은 유입부에 목표 취수량, 유출부에 대기압 조건을 적용하였으며, 여과기에 비해 매우 작게 구성된 여과필터 내부의 유동특성을 검토하기 위해 여과기는 최소 3.0 mm, 여과필터는 1.0 mm의 격자를 적용하였다. 현재 실제 여과시설에 적용되고 있는 여과기 제품 형상을 기준으로 여과기 내부 흐름공간의 크기 및 각도 조정에 따른 유동특성을 검토하여 여과효율을 비교하였으며 통과유량, 유속, 유속벡터 등을 검토하여 균등한 유량과 유속이 발생되는 최적의 여과장치 구조를 도출하였다. 본 연구에서 여과기 내부 구조 변경에 따른 유동특성 검토를 통해 도출된 최적의 여과기 내부크기 및 각도에 대한 설계인자는 여과기 내 여과필터의 효율을 증가시킬 뿐만 아니라 내구성 증진에 도움이 될 것으로 예상된다.

  • PDF

A Study on Fluid Flow Analysis of High Pressure Positive Displacement Pump without Clearance (클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 유동해석에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul
    • Fire Science and Engineering
    • /
    • v.29 no.2
    • /
    • pp.33-38
    • /
    • 2015
  • For the purpose of high-pressure and suction of fixed amount, the development of ultra-high pressure rotating helical gear positive displacement pump with no clearance had been proceeded. The CFD analysis was performed to verify the internal pressure and the discharge flow velocity of the pump. Accordingly, a flow analysis were performed by FVM technique and we were unable to obtain a successful result since the fluid domain is separated because the grid is not configured in a row in FVM flow analysis of the fully enclosed type without clearance. Because of these problems, the flow analysis was performed by MPS method which grid configuration is not needed and the internal pressure and the discharge flow velocity of the pump were confirmed through the MPS flow analysis. At 1,000 rpm rotation speed of the rotor, the minimum internal pressure of the pump was 19.5 bar, maximum pressure was 44.6 bar and average pressure was 33.9 bar. And the minimum discharge flow velocity was 64.5 m/s, maximum discharge flow velocity was 84.8 m/s and average discharge flow velocity was 76.1 m/s. Through this study, we could confirm that MPS method was more suitable than FVM method in terms of flow analysis with no clearance. In addition, the relationship of the flow velocity according to the change of ultra-high pressure rotating helical gear positive displacement pump could be identified through this study.

A Study on Flow Characteristic due to the Periodic Velocity Fluctuation of Upstream at Single Tube (단일 원관에서 전방류의 주기적인 속도 변동에 따른 유동 특성에 관한 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.613-618
    • /
    • 2019
  • The flow-induced vibration in a heat exchanger may cause the damage to piping. Therefore, it is necessary to establish the flow induced vibration characteristics for the structural stability of a heat exchanger. The purpose of this study was to compare the generation, development, and separation characteristics of a vortex around a circular tube with respect to time when the flow velocity of the inlet was fluctuating constantly and periodically. The time characteristics of lift and drag and the PSD characteristics were also investigated. In the case of a constant inlet flow velocity, the well-known Kalman vorticity distribution was shown. The vortex generation, growth, and separation were also observed alternately at the upper and lower sides of the tube. In the case of periodic inlet flow velocity, the vortex occurred simultaneously in the upper and lower sides of the tube. In the case of constant inlet flow velocity, the magnitude of the lift PSD was 500 times larger than that of drag. The frequency was 31.15 Hz and that of drag was doubled at 62.3 Hz. In case of a periodic inlet flow velocity, the PSD of the drag was approximately 500 times larger than that of lift. The frequency was 15.57 Hz, which was the same as the inlet-flow velocity frequency. In addition, the frequency of lift was 31.15 Hz, which was the same Karman vortex frequency.

Flow control of air blowing and vacuuming module using Coanda effect (코안다 효과를 이용한 에어 블로어와 흡입구의 유동 제어)

  • Jeong, Wootae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.115-121
    • /
    • 2017
  • The efficiency of railway track cleaning vehicle for eliminating fine particulate matter (PM10 and PM2.5) in a subway tunnel depends strongly on the structure of the air blowing and suction system installed under the train. To increase the efficiency of underbody suction system, this paper proposes a novel method to use the Coanda effect for the air blower and dust suction module. In particular, through Computational Fluid Dynamics (CFD) analysis, the flow control device induced by the Coanda effect enables an increase in the overall flow velocity and to stabilize the flow distribution of the suction module at a control angle of $90^{\circ}$. In addition, the flow velocity drop at the edge of the air knife-type blower can be improved by placing small inserts at the edge of the blower. Those 4 modular designs of the dust suction system can help remove the dust accumulated on the track and tunnel by optimizing the blowing and suction flows.

On the Viscous Flow Around Breaking Waves Generated by a Submerged Cylinder(Part 2 : Aspects of Viscous Flow) (몰수실린더에 의하여 생성되는 쇄파주의 점성유동의 고찰(제2부: 점성유동특성))

  • B.S. Hyun;Y.H. Shin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.37 no.1
    • /
    • pp.91-98
    • /
    • 2000
  • The present paper is Part 2 of three-part paper for an experimental study on breaking waves generated by a submerged cylinder. Measurements of velocity and head loss profiles at the wakes of cylinder and breaker as well as the turbulent intensities in breaking region were made to elucidate the viscous aspects of breaking waves. Their mutual correlation is also investigated. It is found that the head loss profile is an excellent indicator of the strength and extent of breaker. Very high turbulent intensities measured at and just downstream of the breaker indicate the consequence of energy transfer of wave breaking into turbulence.

  • PDF

Experimental Study on the Flow-field and the Atomization Characteristics of Gas-liquid phase Coaxial Jet (기액동축 분류의 유동장 및 미립화특성에 관한 연구)

  • 전흥신;김형택
    • Journal of Energy Engineering
    • /
    • v.4 no.3
    • /
    • pp.394-401
    • /
    • 1995
  • 본 연구는 중심부에 액체, 외주부에 산화제가 흐르는 기액 동축분류의 유동장에 대한 것이다. 기액 동축 분사기는 연료의 분사량이 적은 소형 연소시스템을 고려하여, 실험은 연공비(W1/Wa)가 0.6 이하를 대상으로, 물과 공기를 사용하여 분사조건에 따른 분무특성과 기액 2상 분무류의 기본구조를 조사하여 액적의 확산, 기액혼합특성에 대하여 검토하여 다음과 같은 결론을 얻었다. 반경방향 기상속도분포 및 액적유속분포는 분구직경 및 분사조건에 관계없이 정규분포에 가까운 형태를 취하고 있으며, 각각 식 (2) 및 (3)으로 나타낼 수 있다. 기상속도는 반치폭은 축방향에 따라 일정한 구배 (≒4.6)로서 증가하며, 기상만의 단상분류의 구배(≒6)에 비해서 완만하다. 액적유속 반치폭은 축방향에 따라 더욱 완만한 구배(≒3.1)로서 증가한다. 무차원 액적유속분포는 축방향에 따라 일정한 구배(n≒1.5)로서 감소한다. 액적의 확산은 상대적으로 기액유량비가 클수록 효과적으라고는 말할 수 없고, 최대 확산을 이루는 최적의 기액유량비가 존재한다.

  • PDF

Development of Software for Electrochemical Plating Simulation Including Diffusion Layer Effects (확산층을 고려한 정밀 도금 Simulator 개발)

  • Seo, Seok;Lee, Ju-Dong;Gwon, Si-Hyeon;Ryu, Dong-Hwan
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.11a
    • /
    • pp.76-77
    • /
    • 2012
  • 전기 도금 시스템에서 전산모사 해석을 이용하여 도금층 두께를 정확히 예측하기 위해서 음극 표면의 확산층이 고려된 도금 Simulator를 개발하였다. 특정 형상의 경우 도금액 교반이 원활하지 않아 불균일한 도금이 이루어지는 경우가 있기 때문에 이를 예측하기 위해서는 교반 영향을 나타내는 확산층을 고려해야 한다. 유동해석을 통해 도금액 교반 조건 및 형상에 따른 음극 표면의 유속을 결정하고 유속별 도금액 DB를 구성하여 음극의 위치별 분극곡선을 차별화하여 유동 조건에 따른 확산층 변화를 고려하는 형태로 구현하였다. 유속별 도금액 DB는 실험 데이터 및 해석 데이터를 종합하여 구축하였다. 교반의 영향을 많이 받는 시스템을 대상으로 개발된 Simulator 결과의 타당성을 검증하였고 확산층 적용에 따른 도금 결과의 차이를 확인하였다.

  • PDF

Test Study about Electro magnetic force effect to apply dredging soil transport (준설토 이송시 유동효율에 미치는 전자기장 인가 영향에 대한 실험적 고찰)

  • Kim, Yuseung;Lee, Myunghan;Lee, Yunjin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2883-2890
    • /
    • 2015
  • As the research about increasing the efficiency of dredging soil transport, the technology, which reduce the friction between pipe wall and fluid in the pipe and disturbed generating pipe blockage, has been developed. So for the purpose of applying this technology to real construction site, main test has been tried at the real scale test in field(500m dredging soil transport length). As a test result, this paper will show 30% flow efficiency increasing by permitted electro magnetic force to the pipe. And test result was evaluated as a ultra sonic velocity profiler.