Effects of Various Ventilation Systems on the Carbon Dioxide Concentration and Fruiting Body Formation of King Oyster Mushroom (Pleurotus eryngii) Grown in Culture Bottles (새송이버섯 병재배에서 환기방법이 이산화탄소 농도 및 자실체형성에 미치는 영향)

  • Lee, Hyun-Uk;Ahn, Mi-Jeong;Lee, Shin-Woo;Lee, Cheol-Ho
    • Journal of Life Science
    • /
    • v.17 no.1 s.81
    • /
    • pp.82-90
    • /
    • 2007
  • In an attempt to establish the appropriate ventilation device for the bottle culture of king oyster mushroom (Pleurotus eryngii), we investigated carbon dioxide concentration and fruiting body formation according to the various ventilation systems within the mushroom house. In addition to, the efficiency of air circulation and growth rate as well as the appearance of physiologically abnormal phenotypes during their growth stage were also evaluated. four different ventilation devices, parallel-pressure type, positive-pressure type, negative-pressure type, and positive- and negative-pressure type were applied in this study. The positive-and negative-pressure type showed the highest efficiency of air circulation as $CO_2$ concentration was 800 ppm and the level of air current was relatively low compared to the other types (the $CO_2$ concentration of parallel-pressure type was 1,400 ppm). Moreover, the stipe length, the cap diameter, yield, and general quality grown in positive- and negative type ventilation device were also better than in the other three devices though it took slightly longer period for harvesting (18.4 days) than the others (17.6, 17.9 and 18.3 days). The appearance of physiologically abnormal phenotypes such as fruiting body lump, soft rot, and brown rot were significantly decreased in positive-and negative type compared to other types, while the appearance rates were not much different for other symptoms of bacterial ooze, stipe limb and stipe bumpy. In summary, we propose that the optimal ventilation system for the bottle culture of king oyster mushroom is positive- and negative type, and this device is expected to increase the total quality as well as yield all year around.

Fabrication and Performance of Anode-Supported Flat Tubular Solid Oxide Fuel Cell Unit Bundle (연료극 지지체식 평관형 고체산화물 연료전지 단위 번들의 제조 및 성능)

  • Lim, Tak-Hyoung;Kim, Gwan-Yeong;Park, Jae-Layng;Lee, Seung-Bok;Shin, Dong-Ryul;Song, Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.283-287
    • /
    • 2007
  • KIER has been developing the anode-supported flat tubular solid oxide fuel cell unit bundle for the intermediate temperature($700{\sim}800^{\circ}C$) operation. Anode-supported flat tubular cells have Ni/YSZ cermet anode support, 8 moi.% $Y_2O_3$ stabilized $ZrO_2(YSZ)$ thin electrolyte, and cathode multi-layer composed of Sr-doped $LaSrMnO_3(LSM)$, LSM-YSZ composite, and $LaSrCoFeO_3(LSCF)$. The prepared anode-supported flat tubular cell was joined with ferritic stainless steel cap by induction brazing process. Current collection for the cathode was achieved by winding Ag wire and $La_{0.6}Sr_{0.4}CoO_3(LSCo)$ paste, while current collection for the anode was achieved by using Ni wire and felt. For making stack, the prepared anode-supported flat tubular cells with effective electrode area of $90\;cm^2$ connected in series with 12 unit bundles, in which unit bundle consists of two cells connected in parallel. The performance of unit bundle in 3% humidified $H_2$ and air at $800^{\circ}C$ shows maximum power density of $0.39\;W/cm^2$ (@ 0.7V). Through these experiments, we obtained basic technology of the anode-supported flat tubular cell and established the proprietary concept of the anode-supported flat tubular cell unit bundle.

Enhanced Growth Inhibition by Combined Gene Transfer of p53 and $p16^{INK4a}$ in Adenoviral Vectors to Lung Cancer Cell Lines (폐암세포주에 대한 p53 및 $p16^{INK4a}$의 복합종양억제유전자요법의 효과)

  • Choi, Seung -Ho;Park, Kyung-Ho;Seol, Ja-Young;Yoo, Chul-Gyu;Lee, Choon-Taek;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.1
    • /
    • pp.67-75
    • /
    • 2001
  • Background : Two tumor suppressor genes, p53 and p16, which have different roles in controlling the cell cycle and inducing apoptosis, are frequently inactivated during carcinogenesis including lung cancer. Single tumor suppressor gene therapies using either with p53 or p16 have been studied extensively. However, there is a paucity of reports regarding a combined gene therapy using these two genes. Methods : The combined effect of p53 and p16 gene transfer by the adenoviral vector on the growth of lung cancer cell lines and its interactive mechanism was investigated. Results : An isobologram showed that the co-transduction of p53 and p16 exhibited a synergistic growth in hibitory effect on NCI H358 and an additive effect on NCI H23. Cell cycle analysis demonstrated the induction of a synergistic G1/S arrest by a combined p53 and p16 transfer. This synergistic interaction was again confirmed in a soft agar confirmed in a soft agar clonogenic assay. Conclusion : These observations suggest the potential of a p53 and p16 combination gene therapy as another potent strategy in cancer gene therapy.

  • PDF

A preliminary assessment of high-spatial-resolution satellite rainfall estimation from SAR Sentinel-1 over the central region of South Korea (한반도 중부지역에서의 SAR Sentinel-1 위성강우량 추정에 관한 예비평가)

  • Nguyen, Hoang Hai;Jung, Woosung;Lee, Dalgeun;Shin, Daeyun
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.6
    • /
    • pp.393-404
    • /
    • 2022
  • Reliable terrestrial rainfall observations from satellites at finer spatial resolution are essential for urban hydrological and microscale agricultural demands. Although various traditional "top-down" approach-based satellite rainfall products were widely used, they are limited in spatial resolution. This study aims to assess the potential of a novel "bottom-up" approach for rainfall estimation, the parameterized SM2RAIN model, applied to the C-band SAR Sentinel-1 satellite data (SM2RAIN-S1), to generate high-spatial-resolution terrestrial rainfall estimates (0.01° grid/6-day) over Central South Korea. Its performance was evaluated for both spatial and temporal variability using the respective rainfall data from a conventional reanalysis product and rain gauge network for a 1-year period over two different sub-regions in Central South Korea-the mixed forest-dominated, middle sub-region and cropland-dominated, west coast sub-region. Evaluation results indicated that the SM2RAIN-S1 product can capture general rainfall patterns in Central South Korea, and hold potential for high-spatial-resolution rainfall measurement over the local scale with different land covers, while less biased rainfall estimates against rain gauge observations were provided. Moreover, the SM2RAIN-S1 rainfall product was better in mixed forests considering the Pearson's correlation coefficient (R = 0.69), implying the suitability of 6-day SM2RAIN-S1 data in capturing the temporal dynamics of soil moisture and rainfall in mixed forests. However, in terms of RMSE and Bias, better performance was obtained with the SM2RAIN-S1 rainfall product over croplands rather than mixed forests, indicating that larger errors induced by high evapotranspiration losses (especially in mixed forests) need to be included in further improvement of the SM2RAIN.

A Comparative Study of Subset Construction Methods in OSEM Algorithms using Simulated Projection Data of Compton Camera (모사된 컴프턴 카메라 투사데이터의 재구성을 위한 OSEM 알고리즘의 부분집합 구성법 비교 연구)

  • Kim, Soo-Mee;Lee, Jae-Sung;Lee, Mi-No;Lee, Ju-Hahn;Kim, Joong-Hyun;Kim, Chan-Hyeong;Lee, Chun-Sik;Lee, Dong-Soo;Lee, Soo-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.234-240
    • /
    • 2007
  • Purpose: In this study we propose a block-iterative method for reconstructing Compton scattered data. This study shows that the well-known expectation maximization (EM) approach along with its accelerated version based on the ordered subsets principle can be applied to the problem of image reconstruction for Compton camera. This study also compares several methods of constructing subsets for optimal performance of our algorithms. Materials and Methods: Three reconstruction algorithms were implemented; simple backprojection (SBP), EM, and ordered subset EM (OSEM). For OSEM, the projection data were grouped into subsets in a predefined order. Three different schemes for choosing nonoverlapping subsets were considered; scatter angle-based subsets, detector position-based subsets, and both scatter angle- and detector position-based subsets. EM and OSEM with 16 subsets were performed with 64 and 4 iterations, respectively. The performance of each algorithm was evaluated in terms of computation time and normalized mean-squared error. Results: Both EM and OSEM clearly outperformed SBP in all aspects of accuracy. The OSEM with 16 subsets and 4 iterations, which is equivalent to the standard EM with 64 iterations, was approximately 14 times faster in computation time than the standard EM. In OSEM, all of the three schemes for choosing subsets yielded similar results in computation time as well as normalized mean-squared error. Conclusion: Our results show that the OSEM algorithm, which have proven useful in emission tomography, can also be applied to the problem of image reconstruction for Compton camera. With properly chosen subset construction methods and moderate numbers of subsets, our OSEM algorithm significantly improves the computational efficiency while keeping the original quality of the standard EM reconstruction. The OSEM algorithm with scatter angle- and detector position-based subsets is most available.

Modeling of Sensorineural Hearing Loss for the Evaluation of Digital Hearing Aid Algorithms (디지털 보청기 알고리즘 평가를 위한 감음신경성 난청의 모델링)

  • 김동욱;박영철
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.59-68
    • /
    • 1998
  • Digital hearing aids offer many advantages over conventional analog hearing aids. With the advent of high speed digital signal processing chips, new digital techniques have been introduced to digital hearing aids. In addition, the evaluation of new ideas in hearing aids is necessarily accompanied by intensive subject-based clinical tests which requires much time and cost. In this paper, we present an objective method to evaluate and predict the performance of hearing aid systems without the help of such subject-based tests. In the hearing impairment simulation(HIS) algorithm, a sensorineural hearing impairment medel is established from auditory test data of the impaired subject being simulated. Also, the nonlinear behavior of the loudness recruitment is defined using hearing loss functions generated from the measurements. To transform the natural input sound into the impaired one, a frequency sampling filter is designed. The filter is continuously refreshed with the level-dependent frequency response function provided by the impairment model. To assess the performance, the HIS algorithm was implemented in real-time using a floating-point DSP. Signals processed with the real-time system were presented to normal subjects and their auditory data modified by the system was measured. The sensorineural hearing impairment was simulated and tested. The threshold of hearing and the speech discrimination tests exhibited the efficiency of the system in its use for the hearing impairment simulation. Using the HIS system we evaluated three typical hearing aid algorithms.

  • PDF

Validation of Sea Surface Wind Speeds from Satellite Altimeters and Relation to Sea State Bias - Focus on Wind Measurements at Ieodo, Marado, Oeyeondo Stations (인공위성 고도계 해상풍 검증과 해상상태편차와의 관련성 - 이어도, 마라도, 외연도 해상풍 관측치를 중심으로 -)

  • Choi, Do-Young;Woo, Hye-Jin;Park, Kyung-Ae;Byun, Do-Seong;Lee, Eunil
    • Journal of the Korean earth science society
    • /
    • v.39 no.2
    • /
    • pp.139-153
    • /
    • 2018
  • The sea surface wind field has long been obtained from satellite scatterometers or passive microwave radiometers. However, the importance of satellite altimeter-derived wind speed has seldom been addressed because of the outstanding capability of the scatterometers. Satellite altimeter requires the accurate wind speed data, measured simultaneously with sea surface height observations, to enhance the accuracy of sea surface height through the correction of sea state bias. This study validates the wind speeds from the satellite altimeters (GFO, Jason-1, Envisat, Jason-2, Cryosat-2, SARAL) and analyzes characteristics of errors. In total, 1504 matchup points were produced using the wind speed data of Ieodo Ocean Research Station (IORS) and of Korea Meteorological Administration (KMA) buoys at Marado and Oeyeondo stations for 10 years from December 2007 to May 2016. The altimeter wind speed showed a root mean square error (RMSE) of about $1.59m\;s^{-1}$ and a negative bias of $-0.35m\;s^{-1}$ with respect to the in-situ wind speed. Altimeter wind speeds showed characteristic biases that they were higher (lower) than in-situ wind speeds at low (high) wind speed ranges. Some tendency was found that the difference between the maximum and minimum value gradually increased with distance from the buoy stations. For the improvement of the accuracy of altimeter wind speed, an equation for correction was derived based on the characteristics of errors. In addition, the significance of altimeter wind speed on the estimation of sea surface height was addressed by presenting the effect of the corrected wind speeds on the sea state bias values of Jason-1.

A Study on Remediation of Explosives-Contaminated Soil/Ground Water using Modified Fenton Reaction and Fenton-like Reaction (Modified Fenton Reaction과 Fenton-like Reaction을 이용한 화약류 오염 토양/지하수의 처리에 관한 연구)

  • Hur, Jung-Wook;Seo, Seung-Won;Kim, Min-Kyoung;Kong, Sung-Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.153-160
    • /
    • 2005
  • There have been large areas of soil contaminated with high levels of explosives. For this experimental work, 2,4,6-trinitrotoluene (TNT) was tested as a representative explosive contaminant of concern in both aqueous and soil samples and its removal was evaluated using three different chemical treatment methods: 1) the classical Fenton reaction which utilizes hydrogen peroxide ($H_2O_2$) and soluble iron at pH less than 3; 2) a modified Fenton reaction which utilizes chelating agents, $H_2O_2$, and soluble iron at pH 7; and 3) a Fenton-like process which utilizes iron minerals instead of soluble iron and $H_2O_2$, generating a hydroxyl radical. Using classic Fenton reaction, 93% of TNT was removed in 20 h at pH 3 (soil spiked with 300 mg/L of TNT, 3% $H_2O_2$ and 1mM Fe(III)), whereas 21% removed at pH 7. The modified Fenton reaction, using nitrilotriacetic acid (NTA), oxalate, ethylenediaminetetraacetic acid (EDTA), acetate and citrate as representative chelating agents, was tested with 3% $H_2O_2$ at pH 7 for 24 h. Results showed the TNT removal in the order of NTA, EDTA, oxalate, citrate and acetate, with the removal efficiency of 87%, 71%, 64%, 46%, and 37%, respectively, suggesting NTA as the most effective chelating agent. The Fenton-like reaction was performed with water contaminated with 100 mg/L TNT and soil contaminated with 300 mg/L TNT, respectively, using 3% $H_2O_2$ and such iron minerals as goethite, magnetite, and hematite. In the goethite-water system, 33% of TNT was removed at pH 3 whereas 28% removed at pH 7. In the magnetite-water system, 40% of TNT was removed at pH 3 whereas 36% removed at pH 7. In the hematite-water system, 40% of TNT was removed at pH 3 whereas 34% removed at pH 7. For further experiments combining the modified Fenton reaction with the Fenton-like reaction, NTA, EDTA, and oxalate were selected with the natural iron minerals, magnetite and hematite at pH 7, based on the results from the modified Fenton reaction. As results, in case magnetite was used, 79%, 59%, and 14% of TNT was removed when NTA, oxalate, and EDTA used, respectively, whereas 73%, 25%, and 19% removed in case of hematite, when NTA, oxalate, and EDTA used, respectively.

The Consideration about Heavy Metal Contamination of Room and Worker in a Workshop (공작실에서 실내 및 작업종사자의 중금속 오염도에 관한 고찰)

  • Kim Jeong-Ho;Kim Gha-Jung;Kim Sung-Ki;Bea Suk-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2005
  • Purpose : Heavy metal use when producing the block from the workshop. At this time, production of heavy metal dust and fume gives risk in human. This like heavy metal to improve seriousness through measurement and analysis. And by the quest in solution is purpose of this thesis. Materials and Methods : Organization is Inductively Coupled Plasma Atomic Emission Spectrometer, and the object is Deajeon city 4 workshops in university hospital radiation oncology (Bismuth, Lead, Tin and cadmium). Method is the ppb the pumping it does at unit, comparison analysis. And the Calculation heavy metal standard level in air through heavy metal standard level in body and blood, so Heavy metal temporary standard set. Results : Subterranean existence room air quality the administration laws appointed Lead and Cadmium's exposure recommend that it is $3{\mu}g/m^3\;and\;2{\mu}g/m^3$. And Bismuth and Tin decides $7{\mu}g/m^3\;and\;6{\mu}g/m^3$ through standard level in air heavy metal and standard level in body and blood. Heavy metal measurement level of workshops in 4 university hospital Daejeon city compares with work existence and nonexistence. On work nonexistence almost measurement level is below the recommend level. But work existence case express high level. Also consequently in composition ratio of the block is continuous with the detection ratio. Conclusion : Worker's heavy metal contamination imbrued serious for solution founds basic part. In hospital may operation on local air exhauster and periodical efficiency check, protector offer, et al. And worker have a correct understanding part of heavy metal contamination, and have continuous interest, health control. Finally, learned society sphere administer to establishment standard level and periodical measurement. And it founds basic solution plan of periodical special health checkup.

  • PDF

A Study on Contact Dermatitis-Causing Substances Concentration in Commercial Oxidative Hair-Coloring Products (유통 산화형 염모제의 접촉성피부염 유발물질 함량 연구)

  • Na, Young Ran;Koo, Hee Soo;Lee, Seung Ju;Kang, Jung Mi;Jin, Seong Hyeon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.2
    • /
    • pp.203-214
    • /
    • 2014
  • We measured the contact dermatitis-causing substances concentrations in 28 commercial oxidative hair-coloring products. This study was aimed to provide the fundamental data about oxidative hair-coloring products. We selected 10 oxidation dyes (p-phenylenediamine, toluene-2,5-diamine, m-phenylenediamine, nitro-p-phenylenediamine, p-aminophenol, m-aminophenol, o-aminophenol, p-methylaminophenol, N,N'-bis(2-hydroxyethyl)-p-phenylenediamine sulfate, 2-methyl-5-hydroxyethylaminophenol) and 4 heavy metal (nikel; Ni, chromium; Cr, cobalt; Co, copper; Cu) as contact dermatitis-causing substances. To identify 10 oxidation dyes, hexane-2% sodium sulfite was used for the rapid and simple extraction and ultra performance liquid chromatography (UPLC) analysis was used for simultaneous analysis in 12 minutes. 10 oxidative dyes were detected as indicated on the product packaging and each concentration was lower than prescribed upper concentration limit by pharmaceutical manufacturing standards. And we analysed inductively coupled plasma-optical emission spectrophotometer (ICP-OES) for content search of heavy metal after microwave digestion. The heavy metal average concentration in oxidative hair-coloring products was 0.572 ${\mu}g/g$ for Ni, 3.161 ${\mu}g/g$ for Cr, 2.029 ${\mu}g/g$ for Co, 0.420 ${\mu}g/g$ for Cu, respectively. The average of concentration in powder type (henna) was higher than those of other foam and cream type oxidative hair-coloring products as follows; 1.800 ${\mu}g/g$ for Ni, 10.127 ${\mu}g/g$ for Cr, 7.082 ${\mu}g/g$ for Co, 1.451 ${\mu}g/g$ for Cu. Hair coloring products were classified into the six colors - black, dark brown, brown, dark brown, light brown, red brown and analyzed. Brown color had the highest average concentration of Co and the others had the highest average concentration of Cr.