• Title/Summary/Keyword: 위험기계.기구

Search Result 49, Processing Time 0.017 seconds

A Study on the Examination of Explosion Hazardous Area Applying Ventilation and Dilution (환기 및 희석을 적용한 폭발위험장소 검토에 관한 연구)

  • kim, Nam Suk;Lim, Jae Geun;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.27-31
    • /
    • 2018
  • Classification of explosion hazard areas is very important in terms of cost and safety in the workplace handling flammable materials. This is because the radius of the hazardous area determines whether or not the explosion-proof equipment is installed in the electrical machinery and apparatus. From November 6, 2017, KS C IEC-60079-10-1: 2015 will be issued and applied as a new standard. It is important to understand and apply the difference between the existing standard and the new standard. Leakage coefficients and compression factors were added to the leakage calculation formula, and the formula of evaporation pool leakage, application of leakage ball size, and shape of explosion hazard area were applied. The range of the safety factor K has also been changed. Also, in the radius of the hazardous area, the existing standard applies the number of ventilation to the virtual volume, but the revised standard is calculated by using the leakage characteristic value. In this study, we investigated the differences from existing standards in terms of ventilation and dilution and examined the effect on the radius of the hazard area. Comparisons and analyzes were carried out by applying revised standards to workplaces where existing explosion hazard locations were selected. The results showed that even if the ventilation and dilution were successful, the risk radius was not substantially affected.

Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (I) : Based on API RBI Procedures (복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (I) : API RBI 절차에 기반한 위험도 평가)

  • Song, Jung Soo;Yu, Jong Min;Han, Seung Youn;Choi, Jeong Woo;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.1-13
    • /
    • 2018
  • The proportion of natural gas-fueled power generation is expanding due to the change of domestic energy policy pursuing reduction of dust and increasing clean energy consumption. Natural gas fuels used for the combined-cycle power plants and the district-heating power plants are operated at high temperature and high pressure in the fuel supply system. Accidents due to leakage of the gas such as fire and explosion should be prevented by applying risk management techniques. In this study, risk assessment was performed on the natural gas fuel supply system of a combined power plant based on the API RP 581 RBI code. For the application of the API RBI code, lines and segments of the evaluation target system were identified. Operational data and input information were analyzed for the calculations of probability of failure and consequence of failure. The results of the risk assessment were analyzed over time from the initial installation time. In the code-based evaluation, the gas fuel supply system was mainly affected by thinning, external damage, and mechanical fatigue damage mechanisms. As the operating time passes, the risk is expected to increase due to the external damage caused by the CUI(Corrosion Under Insulation).

Development of Osmotic Infusion Pump (삼투압 약물주입 펌프의 개발)

  • Kim, Dong Sun;Choi, Seong Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.6
    • /
    • pp.471-475
    • /
    • 2015
  • Because of increasing demand, a small portable drug injector that uses osmotic pressure for its operation force is developed, and its performance is evaluated. The osmotic drug injector can be small and lightweight because it does not require heavy batteries and an actuator, unlike previous electromechanical drug injectors. Moreover, its injection pressure can be sustained longer than that of previous elastic drug injectors. The new device is composed of a drug sac, osmotic pressure chamber, semipermeable membrane, and solvent chamber. To evaluate its performance, an in-vitro experiment was designed to measure the outflow and the injection pressure with respect to time. The experimental results show that the new drug infuser can continuously deliver 20 ml drug over a period of 20 h. The maximum injecting pressure was over 400 mmHg. Which prevents backflow caused by changes in the outlet pressure resulting from changes to the position of the device and the patient's posture.

Stiffness Analysis of Spring Mechanism for Semi-Automatic Gripper Motion of Tendon-Driven Remote Manipulator (와이어 구동방식 원격조작기용 그리퍼의 반자동 파지 및 해제 동작을 위한 스프링 강성 분석)

  • Yu, Seung-Nam;Lee, Jong-Kwang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.11
    • /
    • pp.1405-1411
    • /
    • 2012
  • Remote handling manipulators are widely used for performing hazardous tasks, and it is essential to ensure the reliable performance of such systems. Toward this end, tendon-driven mechanisms are adopted in such systems to reduce the weight of the distal parts of the manipulator while maintaining the handling performance. In this study, several approaches for the design of a gripper system for a tendon-driven remote handling system are introduced. Basically, this gripper has an underactuated spring mechanism that is combined with a slave manipulator triggered by a master operator. Based on the requirements under the specified tendon-driven mechanism, the connecting position of the spring system on the gripper mechanism and kinematic influence coefficient (KIC) analysis are performed. As a result, a suitable combination of components for the proper design of the target system is presented and verified.

Stewart Platform-Based Master System for Tele-Operation of a Robot Arm (로봇 팔의 원격제어를 위한 스튜어트 플랫폼 기반의 조작장치)

  • Lee, Sang-Duck;Yu, Hong-Sun;Ahn, Kuk-Hyun;Song, Jae-Bok;Kim, Jong-Won;Ryu, Jae-Kwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.2
    • /
    • pp.137-142
    • /
    • 2015
  • Teleoperation of a robot arm working in hazardous environments has been studied in the field of defense and security. A master system is an essential part that plays an important role in the teleoperation. We developed a master system, which is an essential part in the teleoperation, so that it can operate the slave robot arm intuitively and has excellent mobility and portability compared to conventional master systems. The master system adopted a Stewart platform to minimize the size and weight, and the legs of the Stewart platform are composed of wires to improve the operation range of the system. The experimental validation of the developed master system is conducted with a commercial IMU, and the experimental results show that the proposed master system can perform reliable and dexterous teleoperation.

Analysis of Sloping Ground When Lifting with Force Platform (힘판을 이용한 들기 작업시의 경사면 분석)

  • 서승록;김종석
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.5 no.1
    • /
    • pp.77-86
    • /
    • 2000
  • Even manual materials handling tasks(MMHT) is decreasing by adopt of automatic manufacturing system & transportation supporting machine because of increase of productivity, wage lack of labor, safety, in fact working at inclined & complicated slope such as farm, orchard, harbor loading & unloading, logging place and mining place can't be substituted by machine perfectly. So, workers should do MMHT at this place by themselves, lifting on slope can cause much of hazard, include falling. Keeping balance net to slip can be a reason of low back pain(LBP) by overloaded musculoskeletal system but, there's no enough study about lift on slope. Therefore, In this study, we assessed and analyzed change of center of pressure(COP) when lifting on slope by force platform. The result showed that the length lengthen as increasing angle of slope. Especially, the length extremely increased over 15°. Through These basic result, present proper angle boundary, prevent industrial accidents and give proper data not only lifting but also pushing and pulling on slope someday.

  • PDF

Measurement of Sulfur Dioxide Concentration Using Wavelength Modulation Spectroscopy With Optical Multi-Absorption Signals at 7.6 µm Wavelength Region (7.6 µm 파장 영역의 다중 광 흡수 신호 파장 변조 분광법을 이용한 이산화황 농도 측정)

  • Song, Aran;Jeong, Nakwon;Bae, Sungwoo;Hwang, Jungho;Lee, Changyeop;Kim, Daehae
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.293-303
    • /
    • 2020
  • According to the World Health Organization (WHO), air pollution is a typical health hazard, resulting in about 7 million premature deaths each year. Sulfur dioxide (SO2) is one of the major air pollutants, and the combustion process with sulfur-containing fuels generates it. Measuring SO2 generation in large combustion environments in real time and optimizing reduction facilities based on measured values are necessary to reduce the compound's presence. This paper describes the concentration measurement for SO2, a particulate matter precursor, using a wavelength modulation spectroscopy (WMS) of tunable diode laser absorption spectroscopy (TDLAS). This study employed a quantum cascade laser operating at 7.6 ㎛ as a light source. It demonstrated concentration measurement possibility using 64 multi-absorption lines between 7623.7 and 7626.0 nm. The experiments were conducted in a multi-pass cell with a total path length of 28 and 76 m at 1 atm, 296 K. The SO2 concentration was tested in two types: high concentration (1000 to 5000 ppm) and low concentration (10 ppm or less). Additionally, the effect of H2O interference in the atmosphere on the measurement of SO2 was confirmed by N2 purging the laser's path. The detection limit for SO2 was 3 ppm, and results were compared with the electronic chemical sensor and nondispersive infrared (NDIR) sensor.

Comparative analysis of status of safety accidents and importance-performance analysis (IPA) about precautions of safety accidents by employment type of industry foodservices in Jeonbuk area (전북지역 산업체급식소 조리종사자의 고용형태에 따른 안전사고 실태 및 안전사고 예방관리에 대한 중요도와 수행도 분석)

  • So, Hee;Rho, Jeong Ok
    • Journal of Nutrition and Health
    • /
    • v.50 no.4
    • /
    • pp.402-414
    • /
    • 2017
  • Purpose: The purpose of the study was to evaluate the status of safety accidents and importance-performance analysis (IPA) between regular and non-regular employees in industry foodservices. Methods: The participants were regular employees (n = 119) and non-regular employees (n = 163) in industry foodservices in the Jeonbuk area. Demographic characteristics, status of safety accidents, safety education, and importance and performance status were assessed using a self-administered questionnaire. Results: Approximately 66.4% of regular employees and 53.4% of non-regular employees experienced safety accidents (p < 0.05). Types of safety accidents of regular and non-regular employees were mostly burns, and causes were mostly from their own negligence. Approximately 98.3% of regular employees and 95.1% of non-regular employees experienced safety education. Approximately 88.9% of regular employees and 96.8% of non-regular employees received safety education from dietitians. Approximately 41.9% of regular employees and 50.0% of non-regular employees had difficulty applying the contents of safety education due to lack of time during work. As a result of IPA, regular and non-regular employees were aware of the importance of the following and performed them well: 'Clean the floor of the work place', 'Arrange in the work area', 'Wear safety shoes', 'Check for heater cord', and 'Safety cooking when using oil'. On the other hand, they were not aware of the importance of the following and performed them insufficiently: 'Check for the MSDS', 'Aware of chemical signs', 'Wear protection gloves etc.', 'Do stretching exercise', and 'Using ancillary tools'. Conclusion: Therefore, it is necessary to improve the consciousness of dietitians for effective application of safety education contents, development of contents, especially MSDS, and related things.

Chronological observation of intestinal lesions of rots experimentally infected with Echinostoma hortense (흰쥐의 실험적 호르틴스극구흡충 감염에 있어서 장 병변에 대한 경시적 관찰)

  • 이순형;노태영
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.1
    • /
    • pp.45-52
    • /
    • 1990
  • Intestinal histopathological changes due to infection with Echinostcma hortense (Trematoda) were studied in rats after experimental infection with the metacercariae. The metacercariae were obtained from the tadpoles of Rana nigrcmaculata, a second intermediate host infected in the laboratory. Total 18 albino rats(Sprague-Dawley) were given 200 matacercariae each and sacrificed on the day 1, 3, 7, 11, 22 or 44 post-infection(PI) Segments of- the small intestine at 1, 3, 5, 8 and 30 cm posterior to the pylorus(PTP) were rejected and studied histopathologically. 1. The flukes were seen to have intruded into the intervillous space in the upper small intestine at early stages(1∼3 days PI), however, they were located mainly in the intestinal lumen at later stages(7∼44 days PI) . The flukes were sucking and destroying the epithelial layers of villi with their oral and ventral suckers. 2. Histopathological changes of the intestine were recognizable in as early as 1∼3 days after infection, and the changes became severer as the infection progressed. 3. The intestinal mucosa was histopathologically characterized by villous atrophy and crypt hyperplasia throughout the infection period. Major villous changes were blunting, fusion, severe destruction and loss of epithelial layers of villi. Villous/crypt(V/C) height ratio was remarkably reduced from 3 : 1 in controls to 1 : 1 in severely infected animals. In the stroma of villi, inaamma- tory cell infiltrations, vascular congestion, edema, and/or fibrosis were recognized. The goblet cells were increased in number after 11 days PI. It was revealed in the present study that the pathological changes in the intestine of rats infected with E. hortense were chieay confined to the mucosal layer of the upper small intestine, however, the changes were very severe accompanying remarkable destruction of villi and loss of mucosal integrity, and persistent until 44 days PI.

  • PDF