• 제목/요약/키워드: 위치영역

검색결과 3,964건 처리시간 0.029초

Effect of Patient Size on Image Quality and Dose Reduction after Added Filtration in Digital Chest Tomosynthesis (부가필터를 적용한 디지털 흉부단층합성검사에서 환자 체형에 따른 화질 평가와 선량감소 효과)

  • Bok, Geun-Seong;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • 제12권1호
    • /
    • pp.23-30
    • /
    • 2018
  • To evaluate the effect of patient size on effective dose and image quality for Digital Chest Tomosynthesis(DTS) using additional 0.3 mm copper filtration. Eighty artificial nodules were placed in the thorax phantom("Lungman," Kyoto Kagaku, Japan), and Digital Chest Tomosynthesis(DTS) images of the phantom were acquired both with and without added 0.3 mm Cu filtration. To simulate patients of three sizes: small, average size and oversize, one or two 20-mm-thick layer of PMMA(polymethyl methacrylatek) blocks were placed on the phantom. The Effective dose was calculated using Monte Carlo simulations. Two evaluations of image quality methods have been employed. Three readers counted the number of nodules detected in the lung, and the measured contrast-to-noise ratios(CNRs) were used. Data were analyzed statistically. The ED reduced $26{\mu}Sv$ in a phantom, $33{\mu}Sv$ in one 20-mm-thick layer of PMMA block placed on the phantom, and $48{\mu}Sv$ in two 20-mm-thick layer of PMMA blocks placed on the phantom. The Effective dose(ED) differences between DTS with and without filtration were significant(p<0.05). In particular, when we used two 20-mm-thick layer of PMMA blocks placed on the phantom, the ED was significantly reduced by 36% compared with those without additional filtration. Nodule detection sensitivities were not different between with and without added filtration. Differences of CNRs were statistically insignificant(p>0.05). Use of additional filtration allows a considerable dose reduction during Digital Chest Tomosynthesis(DTS) without loss of image quality. In particular, additional filtration showed outstanding result for effective dose reduction on two 20-mm-thick layer of PMMA blocks placed on the phantom. It applies to overweight patients.

Optical properties of $ZnIn_2Se$ and $ZnIn_2Se_4$:Co single crystals ($ZnIn_2Se_4$$ZnIn_2Se_4$:Co 단결정의 광학적 특성)

  • 최성휴;방태환;박복남
    • Journal of the Korean Vacuum Society
    • /
    • 제6권2호
    • /
    • pp.129-135
    • /
    • 1997
  • Undoped and Co-doped $ZnIn_2Se_4$ single crystals crystallized in the tetragonal space group 142m, with lattice constants a=5.748 $\AA$ and c=11.475 $\AA$, and a=5.567 $\AA$ and c=11.401 $\AA$. The optical absorption measured near the fundamental band edge showed that the optical energy band structure of these compounds had an indirect band gap, the direct and the indirect energy gaps of these compounds decreased as temperature changed from 10 to 300 K. The temperature coefficients of the direct energy gaps were found to be $\alpha=3.71\times10^{-4}$eV/K and $\beta$=519 K for $\alpha=3.71\times10^{-4}$eV/K and $\beta$=421K for $ZnIn_2Se_4$: Co. The temperature coefficients of the indirect energy gaps were also found to be $\alpha=2.31\times10^{-4}$ eV/K and $\beta$=285 K for $ZnIn_2Se_4$, and $\alpha=3.71\times10^{-4}$eV/K and $\beta$=609 K for $ZnIn_2Se_4$:Co, respectively. Six impurity optical absorption peaks due to cobalt are observed in $ZnIn_2Se_4$:Co single crystal. These impurity optical absorption peaks can be attibuted to the electronic transitions between the split energy levels of$CO^{2+}$ ions located at Td symmetry site of $ZnIn_2Se_4$ host lattice. The 1st order spin-orbit coupling constant ($\lambda$), Racah parameter (B), and crystal field parameter (Dq) ARE GIVEN AS -$243\textrm{cm}^{-1}, 587\textrm{cm}^{-1}, \;and\;327\textrm{cm}^{-1}$, respectively.

  • PDF

Evaluation of Image Quality in Low Tube-Voltage Chest CT Scan (흉부 CT 검사 시 저 관전압 영상의 화질평가에 관한 연구)

  • Kim, Hyun-Ju;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of Radiation Protection and Research
    • /
    • 제35권4호
    • /
    • pp.135-141
    • /
    • 2010
  • Purpose : The patients who visited this department for pulmonary disease and need CT scans for Follow-up to observe change of CT value, evaluation of image quality and decrease of radiation dose as change of kVp. Subjects and Methods : Subjects were the patients of 20 persons visited this department for pulmonary disease and Somatom Sensation 16(Semens, Enlarge, Germany) was used. Measurement of CT value as change of kVp was done by setting up ROI diameter of 1cm at the height of thyroid, aortic arch, right pulmonary artery in arterial phase image using 100 kVp, measuring 3 times, and recorded the average. CT value of phantom was measured by scanning phantoms which means contrast media diluted by normal saline by various ratio with tube voltage of 80 kVp, 100 kVp, 120 kVp, 140 kVp and recorded the average of 3 CT values of center of phantom image. In analysing radiation dose, CTDIVOL values of the latest arterial phase image of 120 kVp and as this research set that of 100 kVp were analyzed comparatively. 2 observers graded quality of chest images by 5 degrees (Unacceptable, Suboptimal, Adequate, Good, Excellent). Results : CT value of chest image increased at 100 kVp by 14.06%~27.26% in each ROI than 120 kVp. CT value of phantom increased as tube voltage lowered at various concentration of contrast media. CTDIVOL decreased at 100 kVp(5.00 mGy) by 36% than 120 kVp(7.80 mGy) in radiation dose analysis. here were 0 Unacceptable, 1 Suboptimal, 3 Adequate, 10 Good, 6 Excellent in totally 20 persons. Conclusion : Chest CT scanning with low kilo-voltage for patients who need CT scan repeatedly can bring images valuable for diagnose, and decrease radiation dose against patients.

NMR Spectroscopy and Mass Spectrometry of Phenylethanol Galactoside synthesized using Escherichia coli 𝛽-Galactosidase (대장균 베타-갈락토시데이즈를 이용하여 합성된 Phenylethanol Galactoside의 NMR Spectroscopy 및 Mass spectrometry)

  • Lee, Hyang-Yeol;Jung, Kyung-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • 제37권5호
    • /
    • pp.1323-1329
    • /
    • 2020
  • To characterize the molecular structure of PhE-gal synthesized using Escherichia coli 𝛽-gal, NMR (1H- and 13C-) spectroscopy and mass spectrometry of PhE-gal were conducted. 1H NMR spectrum of PhE-gal showed multiple peaks corresponding to the galactosyl group, which is an evidence of galactosylation on 2-phenylethanol (PhE). Downfield proton peaks at 𝛿H 7.30~7.21 ppm showed the presence of aromatic protons of PhE as well as benzyl CH2 protons at 𝛿H 2.88 ppm. Up field proton peaks at 𝛿H 4.31 ppm, 4.07 ppm and multiple peaks from 𝛿H 3.86~3.38 ppm are indicative of galactocylation on PhE. 13C NMR spectrum revealed the presence of 12 carbons suggestive of PhE-gal. Among 12 carbon peaks from PhE-gal, the four peaks at 138.7, 129.0, 128.6 and 126.5 were assigned aromatic carbons in the phenyl ring. Three peaks at 129.0, 128.6 and 126.5 showed high intensities, indicating CH aromatic carbons. 13C NMR data of PhE-gal showed 6 monosaccharide peaks from galactose and 2 peaks from aliphatic chain of PhE, indicating that PhE-gal was galactosyl PhE. The mass value (sodium adduct ion of PhE-gal, m/z = 307.1181) from mass spectrometry analysis of PhE-gal, and 1H and 13C NMR spectral data were in good agreement with the expecting structure of PhE-gal. We are expecting that through future study it will eventually be able to develop a new additive with low cytotoxicity.

Gaussian Filtering Effects on Brain Tissue-masked Susceptibility Weighted Images to Optimize Voxel-based Analysis (화소 분석의 최적화를 위해 자화감수성 영상에 나타난 뇌조직의 가우시안 필터 효과 연구)

  • Hwang, Eo-Jin;Kim, Min-Ji;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • 제17권4호
    • /
    • pp.275-285
    • /
    • 2013
  • Purpose : The objective of this study was to investigate effects of different smoothing kernel sizes on brain tissue-masked susceptibility-weighted images (SWI) obtained from normal elderly subjects using voxel-based analyses. Materials and Methods: Twenty healthy human volunteers (mean $age{\pm}SD$ = $67.8{\pm}6.09$ years, 14 females and 6 males) were studied after informed consent. A fully first-order flow-compensated three-dimensional (3D) gradient-echo sequence ran to obtain axial magnitude and phase images to generate SWI data. In addition, sagittal 3D T1-weighted images were acquired with the magnetization-prepared rapid acquisition of gradient-echo sequence for brain tissue segmentation and imaging registration. Both paramagnetically (PSWI) and diamagnetically (NSWI) phase-masked SWI data were obtained with masking out non-brain tissues. Finally, both tissue-masked PSWI and NSWI data were smoothed using different smoothing kernel sizes that were isotropic 0, 2, 4, and 8 mm Gaussian kernels. The voxel-based comparisons were performed using a paired t-test between PSWI and NSWI for each smoothing kernel size. Results: The significance of comparisons increased with increasing smoothing kernel sizes. Signals from NSWI were greater than those from PSWI. The smoothing kernel size of four was optimal to use voxel-based comparisons. The bilaterally different areas were found on multiple brain regions. Conclusion: The paramagnetic (positive) phase mask led to reduce signals from high susceptibility areas. To minimize partial volume effects and contributions of large vessels, the voxel-based analysis on SWI with masked non-brain components should be utilized.

Clinical Evaluation of Open Thoracotomy Cases in Spontaneous Pneumothorax (자연 기흉의 개흉례에 대한 임상적 고찰)

  • 이연재;황산원
    • Journal of Chest Surgery
    • /
    • 제30권12호
    • /
    • pp.1225-1231
    • /
    • 1997
  • Spontaneous pneumothorax is the sudden collapse of a lung usually caused by air leakage from a subvisceral pleural blob. Responses to closed thoracostomy,thoracentesls and simple observation are usually prompt and effective. But in some cases, these are unsucceful and open thoracotomy is indicated. A clinical evaluation was performed on 242 cases(236 patients) of open thoracotomy in spontaneous pneumoth rax who were admitted and treated at department of Thoracic and Cardiovascular Surgery. Masan Samsung General Hospital during the past 9 years from January 1988 to December 1996. The results were as follows 1. The sex ratio was male predominance(M:F=11.7:1) 2. The most common age group were 2nd, 3rd decades(2nd=29.3%, 3rd=30.2%). 3. The most common chief complaints were chest pain and dyspnea(chest pain=41.7%. dryspnea= 36.8). 4. The etiologic factors of spontaneous pneumothorax were primary spontaneous pneumothorax(86.4%), tuberculosis(9.1%), COPD(3.7%) and pleuritis(0.8%). 5. The site of spontaneous pneumothorax was 52.1% in right, 45.4% in left and 2.5% in both. 6. The common indications of open thoracotomy were recurrence(44.2%), persistent air leakage(31.8%) and inadequate expansion(15.7%). 7. The operative procedures were bullectomy or mechanical pleurodesis through posterolateral thoracotomy or median sternotomy. 8. The most frequent location of bulla or blob were apical segme t oi RUL(35.1%) and apicoposterior segment of LUL(41.3 %). 9. The number of bulla or blob were mainly 1 to 5(88%), and there were no significant differences among operation indications. 10. The size of bulla or bleb were mainly below 5cm(81%)and small bulla($\leq$1cm) were predominant in recurrence group but large bulla(>5cm)were predominant in persistent air leakage and inadequate expansion group. 11. The pleural adhesion was seen in 54.5%.(Recurrence group 64.1%,Persistent air leakage group 51.9%,Inadequate expansion group 47.4%).

  • PDF

Analysis of Relativity Between Invasiveness on Chest of Tomographic Finding and Histopathologic Invasiveness (종격동 종양의 전산화 단층촬영(CT)소견, 수술소견 및 병리조직학적 침윤도 사이의 상관성 분석)

  • 김용희;이현우
    • Journal of Chest Surgery
    • /
    • 제30권8호
    • /
    • pp.780-785
    • /
    • 1997
  • Mediastinal tumor had been fascinated by its location on heart, great vessels, esophagus, and nervous tissue, its convenience of surgical treatment and superiority of its operative result. Between January 1989 and June 1995, eighty-seven patients with mediastinal tumor which were treated surgically in the Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, School of Medicine, University of Ulsan. To provide the appropriate surgical management of mediastinal tumor, the demographic data, diagnostic evaluation, clinical presentation, location, size, operative finding and histopathologic distribution were reviewed and we analyzed relativity between invasiveness in chest computed tomographic finding or invasiveness on operative finding and histopathologic invasiveness. The anterosuperior mediastinum was the most commonly involved site of a mediastinal tumor(57%), followed by the posterior mediastinum(35%) and middle mediastinum(8%). The most frequently encountered tumors were thymic neoplasia(31%), followed by primary cyst(22%), neurogenic tumor(22%) and teratoma(10%) in decreasing order of frequency. Histopathologically invasive tumors were present in 17 patients(20%) and its site included anterosuperior mediastinum(16%) and posterior mediastinum(4%). All patients in this study underwent chest CT. In chest CT's finding, 15 patients(17%) showed invasiveness. A total excision of the tumor was performed 80 patients(92%), subtotal excision 6 patients(7%) and biopsy only 1 patient(2%). In operative finding, 14 patients(16%) were suspected invasiveness. The mean size of the tumor was 6.0$\pm$ 3.2cm. In anterosuperior mediastinum, the mean size was 6.2$\pm$3.1cm, in middle mediastinum, it was 3.9$\pm$1.1cm, in posterior mediastinum, it was 5.8$\pm$2.6cm. In malignant tumors, the mean size was 7.3$\pm$4.6cm, in benign tumor, it was 5.5$\pm$2.6cm(P<0.05). Relativity between histopathological invasiveness(17 patients) and invasiveness in chest CT's finding(15 patients) included sensitivity 35%, specificity 87% and predictability 35%, relativity between histopathological invasiveness(17 patients) and invasiveness on operative finding included sensitivity 52%, specificity 93% and predictability 64%. In conclusion, since it was proved that the compatibility of preoperative chest CT findings or operative findings and histopathological invasiveness is quite low, it is considered that wide excision of the mediastinal tumor except cystic lesion including adjacent tissues would yield better postoperative results.

  • PDF

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • 제35권6호
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Study on Development of Embedded Source Depth Assessment Method Using Gamma Spectrum Ratio (감마선 스펙트럼 비율을 이용한 매립 선원의 깊이 평가 방법론 개발 연구)

  • Kim, Jun-Ha;Cheong, Jea-Hak;Hong, Sang-Bum;Seo, Bum-Kyung;Lee, Byung Chae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • 제18권1호
    • /
    • pp.51-62
    • /
    • 2020
  • This study was conducted to develop a method for depth assessment of embedded sources using gamma-spectrum ratio and for the evaluation of field applicability. To this end, Peak to Compton and Peak to valley ratio changes were evaluated according to 137Cs, 60Co, 152Eu point source depth using HPGe detector and MCNP simulation. The effects of measurement distance of PTV and PTC methods were evaluated. Using the results, the source depth assessment equation using the PTC and PTV methods was derived based on the detection distance of 50 cm. In addition, the sensitivity of detection distance changes was assessed when using PTV and PTC methods, and error increased by 3 to 4 cm when detection distance decreased by 20 cm based on 50 cm. However, it was confirmed that if the detection distance was increased to 100 cm, the effects of detection distance were small. And PTV and PTC methods were compared with the two distance measurement method which evaluates the depth of source by the change of net peak counting rate according to the detection distance. As a result of source depth assessment, the PTV and PTC showed a maximum error of 1.87 cm and the two distance measurement method showed maximum error of 2.69 cm. The results of the experiment confirmed that the accuracy of the PTV and PTC methods was higher than two distance measurement. In addition, Sensitivity evaluation by horizontal position error of source has maximum error of less than 25.59 cm for the two distance measurement method. On the other hand, PTV and PTC method showed high accuracy with maximum error of less than 8.04 cm. In addition, the PTC method has lowest standard deviation for the same time measurement, which is expected to enable rapid measurement.

Agronomic and Genetic Evaluation on a Dull Mutant Line Derived from the Sodium Azide Treated 'Namil', a Non-Glutinous Japonica Rice (남일벼 돌연변이 유래 중간찰 계통의 작물학적 특성 및 배유특성 지배유전자위 표지)

  • Chun, Jae-Buhm;Jeung, Ji-Ung;Cho, Seong-Woo;Kim, Woo-Jae;Ha, Ki-Young;Kang, Kyung-Ho;Ko, Jae-Kwon;Kim, Hyun-Soon;Kim, Bo-Kyeong
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • 제60권4호
    • /
    • pp.448-457
    • /
    • 2015
  • Developing rice lines with various amylose contents is necessary to diverse usages of rice in terms of raw materials for processed food production, and thereby to promote rice consumption in Korea. A rice mutant line, 'Namil(SA)-dull1' was established through sodium azide mutagenesis on 'Namil', a non-glutinous Korean Japonica rice cultivar. Namil(SA)-dull1' had dull endosperm characteristics and the evaluated amylose content was 12.2%. A total of 94 F2 progenies from a cross between 'Namil(SA)-dull1' and 'Milyang23', a non-glutinous Tongil-type rice cultivar, was used for genetic studies on the endosperm amylose content. Association analyses, between marker genotypes of 53 SSR anchor markers and evaluated amylose contents of each 94 F2:3 seeds, initially localized rice chromosome 6 as the harboring place for the modified allele(s) directing low amylose content of 'Namil(SA)-dull1'. By increasing SSR marker density on the putative chromosomal region followed by association analyses, the target region was narrowed down 0.94 Mbp segment, expanding from 28.95 Mbp to 29.89 Mbp, on rice chromosome 6 pseudomolecule. Among the SSR loci, RM7555 explained 84.2% of total variation of amylose contents in the $F_2$ population. Further physical mapping on the target region directing low amylose content of 'Namil(SA)-dull1' would increase the breeding efficiency in developing promising rice cultivars with various endosperm characteristics.