• Title/Summary/Keyword: 위상 배열 초음파 기법

Search Result 26, Processing Time 0.021 seconds

Procedure Development and Qualification of the Phased Array Ultrasonic Testing for the Nuclear Power Plant Piping Weld (원자력발전소 배관 용접부 위상배열 초음파검사 절차서 개발 및 기량검증)

  • Yoon, Byung-Sik;Yang, Seung-Han;Kim, Yong-Sik;Lee, Hee-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.317-323
    • /
    • 2010
  • The manual ultrasonic examination for the nuclear power plant piping welds has been demonstrated by using KPD(Korean Performance Demonstration) generic procedure. For automated ultrasonic examination, there is no generic procedure and it should be qualified by using applicable automated equipment. Until now, most of qualified procedures used pulse-echo technique and there is no qualified procedure using phased array technique. In this study, data acquisition and analysis software were developed and phased-array transducer and wedge were designed to implement phased array technique for nuclear power plant in-service inspection. The developed procedure are qualified for performance demonstration for the flaw detection, length sizing and depth sizing. The qualified procedure will be applied for the field examination in the nuclear power plant piping weld inspection.

Power Supply of Ultrasonic Phased Array for Focus Control of Acoustic Pressure (음압 초점제어를 위한 초음파 위상배열의 전원 장치)

  • Jung, Hyung-Jon;Kim, Ui-Young;You, Bum-Jae;Choy, Ick
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.137-146
    • /
    • 2019
  • The ultrasonic phased arrays are used for treating tumors in the human body by the focus control of the acoustic pressure at the desired position. The magnitude and phase of the surface acoustic pressure in each ultrasonic transducer is controlled by the magnitude and phase of the applied voltage to it. In this paper, the relationship between the applied voltage and the surface acoustic pressure of the ultrasound transducer is modelled, and the desired voltage is realized by PWM technique. The validity of the proposed method is verified by computer simulation of the focus control of a ultrasonic phased array composed of 61 ultrasonic transducers.

Design and Performance Evaluation of Shear Wave Phased Array Ultrasonic Transducer (횡파 위상배열 초음파 탐촉자 설계 및 성능 평가)

  • Yoon, Byung-Sik;Lee, Hee-Jong;Braconnier, Dominique
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.185-191
    • /
    • 2012
  • Typically, a wedge is involved to generate effectively high inspection angle in pipe weld inspection using phased array ultrasonic technique. But the usage of this wedge for weld or access limited area can cause coverage limitation for the examination volume because of the wedge front length. Therefore, the shear wave phased array probe which can generate high inspection angle without wedge is essentially necessary. In this paper, the shear wave phased array ultrasonic probe which can generate high inspection angle designed by modeling and manufactured from the modelling result. And this shear wave probe tested whether it can detect and sizing for EDM test block that contains various depth. As results, the experimental results show that the designed shear wave phased array probe can detect and size with reliable accuracy. Therefore if this phased array probe apply in field inspection, it is expected that it show more reliable inspection result for plant structure having access limitation.

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique (위상배열 초음파 기법을 이용한 TOFD 검사에 관한 연구)

  • Yoon, Byung-Sik;Kim, Yong-Si;Lee, Hee-Jong;Lee, Young-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.304-310
    • /
    • 2005
  • The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in thick component such as the pressure vessel of power generation industry.

Dynamic Mode Tuning of Ultrasonic Guided Wave Using an Array Transducer (배열 탐촉자를 사용한 유도초음파의 모드선정 기법)

  • Kim, Young-H.;Song, Sung-Jin;Park, Joon-Soo;Kim, Jae-Hee;Eom, Heung-Sup
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.20-26
    • /
    • 2005
  • Ultrasonic guided waves have been widely employed for long range inspection of structures such as plates, rods and pipes. There are numerous modes with different wave velocities, and the appropriate mode selection is one of key techniques in the application of guided waves. In the present work, phase tuning by an array transducer was applied to generate ultrasonic guided waves. For this purpose, 8-channel ultrasonic pulser/receiver and their controller which enables sequential activation of each channels with given time delay were developed. Eight transducers were fabricated in order to generate guided waves by using an array transducer. The selective tuning of wave mode can be achieved by changing the interval between elements of an array transducer.

A Study on a Crack Evaluation Technique for Turbine Blade Root Using Phased Array Ultrasonics (위상배열 초음파를 이용한 터빈 블레이드 루트부내 결함평가 기법 연구)

  • Cho, Yong-Sang;Jung, Gye-Jo;Park, Sang-Ki;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.151-157
    • /
    • 2004
  • Ultrasonic testing is a kind of nondestructive test to detect a crack or discontinuity in materials or on material surfaces by sending ultrasound to it. This conventional ultrasonic technique has some limitations in reliably detecting crack or accurately assessing materials in the case of complex-shaped power plant components such as a turbine blade root. An alternative method for such a difficult inspection is highly needed. In this study, application of a phased array ultrasonic testing (UT) system to a turbine blade, one of the critical power plant components, has been considered, and the particular incident angle has been determined so that the greatest track detectability and the most accurate crack length evaluation nay be achieved. The response of ultrasonic phased array was also analyzed to establish a special method to determine the track )ength without moving the transducer. The result showed that the developed method for crack length assessment is a more accurate and effective method, compared with the conventional method.

Reconstructing Flaw Image Using Dataset of Full Matrix Capture Technique (Full Matrix Capture 데이터를 이용한 균열 영상화)

  • Lee, Tae-Hun;Kim, Yong-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.13-20
    • /
    • 2017
  • A conventional phased array ultrasonic system offers the ability to steer an ultrasonic beam by applying independent time delays of individual elements in the array and produce an ultrasonic image. In contrast, full matrix capture (FMC) is a data acquisition process that collects a complete matrix of A-scans from every possible independent transmit-receive combination in a phased array transducer and makes it possible to reconstruct various images that cannot be produced by conventional phased array with the post processing as well as images equivalent to a conventional phased array image. In this paper, a basic algorithm based on the LLL mode total focusing method (TFM) that can image crack type flaws is described. And this technique was applied to reconstruct flaw images from the FMC dataset obtained from the experiments and ultrasonic simulation.

A Study on the Flaw Evaluation in the Straddle Mount Type Low Pressure Turbine Disc Using Phased Array Ultrasonic Technique (위상 배열 초음파 기법을 이용한 Straddle Mount형 저압 터빈 디스크 결함 평가에 관한 연구)

  • Yang, Seung-Han;Yoon, Byung-Sik;Kim, Yong-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.231-238
    • /
    • 2006
  • Nondestructive examination for low pressure turbine disc in standard nuclear power plant using phased array technique was studied. For this purpose, disc mockups were made and notches were machined in the mockups. Detection and length sizing by different methods are compared. Depth of deep notches could be measured by using AATT(absolute arrival time technique) or RATT(relative arrival time technique) but shallow notches that must be detected in early stage couldn't be measured by these two methods. For this case, notch depth was estimated by using signal response angle range and preyed usefulness.

Study on Enhancements to Ultrasonic Data Imaging Using Full Matrix Capture Technique (Full Matrix Capture 기법을 통한 초음파신호 영상화 향상 연구)

  • Lee, Tae-Hun;Yoon, Byung-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.299-306
    • /
    • 2015
  • A conventional phased array system can control an ultrasonic beam electronically by adjusting the excitation time delay of individual elements in a multi-element probe and produce an ultrasonic image. In Contrast, full matrix capture (FMC) is a data acquisition process that allows receiving ultrasonic signals from one single shot of the phased array transducer element through all the other elements and captures the complete dataset from every possible transmit-receive combination. This FMC data can be used to create the ultrasonic image in post processing. It is possible to produce not only images equivalent to conventional phased array image but also total focusing method (TFM) images with improved resolution and sharpness, which is virtually focused at any point in a region of interest. In this paper, the system that can perform FMC by using a conventional phased array instrument is developed, and a study was conducted on the imaging algorithms to reconstruct sector B-scan and TFM images from FMC dataset.

The Utility of Phased Array Ultrasonic Testing(PAUT) for Corrosion Evaluation of Water Supply Steel Pipes (상수도 강관의 부식 평가에 대한 위상배열초음파(PAUT)의 활용)

  • Sang Hyeok Son;Chang Gun Shin;Jea Yeon Jeong;Jong Sik Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.490-490
    • /
    • 2023
  • 위상배열초음파검사(PAUT)는 기존 초음파검사에서 획득할 수 있었던 A-scan의 결과와 달리, 관로 내부로 진입하지 않고도 부식에 의한 강관 손상 정도를 정량적인 시각적 데이터로 파악할 수 있는 검사 기술이다. 관내부 직접조사가 가능한 상수도 강관을 대상으로 직접조사와 PAUT를 비교한 결과, PAUT는 높은 정확도와 신뢰성을 보여주었다. 또한, 강관 내부의 부식검사에서는 PAUT를 적용함으로써 관체의 부식 면적, 부식 최대 깊이, 부식 위치를 넓은 범위에서 신뢰성 높은 검사 및 결과 도출이 가능하였다. 이러한 결과는 PAUT 기술이 강재 구조물의 다양한 부식 문제를 신속하게 파악하고 해결하는 데 기여할 수 있음을 의미한다. 따라서, 본 검사 기법은 상수도 관로의 강재 진단 및 점검에 있어 높은 신뢰성 및 효율성을 보여 주는 진단기법으로써 다양한 강재 시설물의 평가에 활용성이 클 것으로 판단된다. 이에 따라 PAUT는 상수도 시설물뿐만 아니라 다양한 시설물에서도 높은 활용 가능성을 가질 것으로 예상된다.

  • PDF