A Study of Cooldown Performance of Shutdown Cooling System of Korea Next Generation Reactor (차세대 원자로 정지냉각계통의 냉각 성능에 대한 연구)

  • 유성연;이상섭
    • Journal of Energy Engineering
    • /
    • v.8 no.4
    • /
    • pp.525-532
    • /
    • 1999
  • The standardized Korea Next Generation Reactor (KNGR) NSSS has developed in the basis of the ABB-CE System 80+ design concept. In this study, several regulatory requirements for the KNGR shutdown cooling system (SCS) operation are investigated. The purpose of this study is to establish the technical self-reliance for SCS design by supporting fundamental data such as SDCHX effective area and reactor CCW flow rate. Thermal power of KNGR would be increased to about 4,000 $MW_{th}$ in comparison with thermal power 2.825 $MW_{th}$ of UCN 3&4, therefore, SCS design data shall b recalculated by using the KDESCENT Code, which could evaluate cooling capability of SCS. It is found that SCS minimum flow rate is able to remove the primary sensible heat. Reviewing the major components such as heat exchanger, pump, value, and operating procedure, it is concluded as follows.

  • PDF

Analysis of Cooldown Capability for the HWR Shutdown Cooling System (중수로 정지냉각계통의 냉각능력 분석)

  • Sin, Jeong-Cheol
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.259-266
    • /
    • 2011
  • Following the reactor shutdown, the reactor shutdown cooling system must be designed to supply the coolant sufficiently not only to remove the decay heat but to maintain the adequate cooling rate to protect the reactor equipments. In this study, KDESCENT code for the light water reactor and SOPHT, SDCS codes for the heavy water reactor were compared and analyzed to investigate the cooling capability during the shutdown cooling process. The shutdown cooling system design requirements were satisfied during cooling process for both the SDCP and the HTP modes and the design cooling rate of $2.8^{\circ}C/min$ or below was maintained using the SDC heat exchangers. This study shows that the shutdown cooling system in the Wolsong 2, 3, 4 reactors provides sufficient cooling to maintain the nuclear fuel integrity by removing the decay heat of the nuclear fission product.

SOPHT 코드를 이용한 열수송계통의 정지냉각 천이해석

  • 김태한;김영보;정종식;한상구
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.371-376
    • /
    • 1995
  • CANDU-6형 원자로의 정지냉각계통(Shutdown Cooling System, SDCS)은 영출력 고온상태의 원자로를 상온상태로 냉각시킬 수 있도록 설계되었다. 본 해석은 증기발생기와 복수기증기방출밸브(CSDV) 및 정지냉각펌프를 이용한 정상냉각과 열수송펌프를 이용한 26$0^{\circ}C$부터 냉각 및 정지냉각펌프를 이용한 26$0^{\circ}C$부터 냉각의 두 가지 비정상냉각에 대해서 중수로 계통설계의 열수력 해석코드인 SOPHT 코드를 사용하여 해석하였다. 해석결과에 따라 주요기기들의 냉각천이에 따른 운전부하(service loadings)조건이 주어졌으며 또한 정지냉각계통은 열수송계통과 관련 보조계통을 정지냉각계통 열교환기 2차측에서 비등이 발생하지 않고 정상냉각 허용한계인 2.8$^{\circ}C$/min를 만족하면서 냉각할 수 있음을 확인하였다.

  • PDF

영광 3&4호기 부분충수운전시 정지냉각계통 최소유량 감소에 대한 영향분석

  • 오광석;오종필;김도현;이중섭;유병철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.385-390
    • /
    • 1996
  • 영광 3&4호기의 부분충수운전시 정지냉각계통 최소유량의 감소에 따른 영향을 노심의 잔열제거 능력 및 저압안전주입펌프의 성능 측면에서 분석하였다. 정지냉각계통 성능해석용 전산코드인 KDESCENT를 수정하여 사용하였으며 보수적인 초기조건 및 가정을 사용하였다. 분석결과 부분충수 운전동안 원자로냉각재의 최고 허용온도를 작업자의 접근을 위한 설계온도인 140 ℉로 설정할 경우 원자로 정지후 4일 시점에서 이를 만족할 수 있는 정지냉각계통의 최소유량은 실제값으로 3000 gpm(계측기의 오차포함 3440 gpm)임을 알 수가 있었다. 이 유량은 붕산희석이나 성층화, 저압안전 주입펌프의 성능 측면에서도 허용가능한 값이다.

  • PDF

Single Point Vulnerability Analysis of Reactor Coolant System in OPR-1000 (표준형 원전 원자로냉각재계통의 발전정지유발기기 분석)

  • Lee, Eun-Chan;Bae, Yeon-Kyoung;Kim, Myung-Su
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1999-2000
    • /
    • 2011
  • 본 연구의 목적은 발전소의 정상적인 출력운전을 위해 필요한 주요 계통의 기능에 영향을 미쳐 발전소 불시정지를 유발할 수 있는 핵심 기기, 즉, 발전정지유발기기의 설치 개소를 체계적인 방법을 통하여 정밀 분석하고, 해당 기기의 고장모드와 그 영향을 검토하여 이를 방지하기 위한 대책을 수립하도록 하는 것이다. 발전정지유발기기의 평가는 발전소 종사자로 하여금 가동 중 발전소에서 발생 가능한 발전정지 영향기기와 그들의 상호관계를 이해하고, 정량적 평가를 통해 해당기기들의 발전소 발전정지 영향을 시각적으로 확인하여 불시 발전정지를 예방할 수 있는 대응 논리를 인지할 수 있도록 하는데 그 목적이 있다. 원자로냉각재계통에 대한 발전정지유발기기(SPV, Single Point Vulnerability)를 분석하기 위해 고장모드영향분석(FMEA, Failure Mode Effect Analysis)을 수행하고 상세 고장수목을 개발하여 통합단위의 계통 분석을 수행하였다. 분석결과 원자로냉각재계통의 발전정지유발기기는 원자로냉각재 펌프와 가압기 주살수 밸브의 제어회로에 집중되어 있는 것으로 나타났다.

  • PDF

Risk Model Development for PWR During Shutdown (원자로 정지 동안의 위해도 모델 개발)

  • Yoon, Won-Hyo;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1989
  • Numerous losses of decay heat removal capability have occurred at U during stutodwn while its significance to safety is needless to say. A study is carried out as an attempt to assess what could be done to lower the frequency of these events and to mitigate their consequences in the unlikely event that one occurs. The shutdown risk model is developed and analyzed using Event/Fault Tree for the typical pressurized water reactor. The human cognitive reliability (HCR) model, two-stage bayesian approach and staircase function model are used to estimate human reliability, initiating event frequency and offsite power non-recovery probability given loss of offsite power, respectively. The results of this study indicate that the risk of a Pm at shutdown is not much lower than the risk when the plant is operating. By examining the dominant accident sequences obtained, several design deficiencies are identified and it is found that some proposed changes lead to significant reduction in core damage frequency due to loss of cooling events.

  • PDF

가압중수형 원자로의 주증기관 파단사고 대처를 위한 운전기법

  • 권종수;박성훈;김성래
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.327-332
    • /
    • 1995
  • 가압중수형 원자로의 원자로건물내 주중기관 파단사고는 냉각재 상실사고와는 달리 핵연료 건전성이 유지됨에도 불구하고 파단 부위를 통한 과도한 중기 방출에 따른 일차측 급냉 및 감압에 의하여 경수를 수원으로 사용하는 비상노심냉각 계통(Emergency Core Cooling System:ECCS)의 작동으로 인하여 일차측 중수의 규정농도가 규정치 98% 이하로 저하되어 교체 또는 승급을 요하는 막대한 경제적 손실을 초래 할 수 있다. 원자로건물내 주중기관 파단사고시 비상노심냉각계통의 작동을 방지 또는 지연시키기 위한 운전기법으로 이차측 급수의 차단을 고려하였다. 주증기관 파단크기 50% 이하 범위에서는 원자로 정지후 급수 차단을 통해 비상노심냉각계통 작동을 막을 수 있음이 평가되었다.

  • PDF

Failure Cause Analysis for Loss of Off-site Power Test during Normal Full Power Operation On Wolsong-4 NPP (월성원전 4호기 전 출력 운전시 소외전원상실시험 실패 원인분석)

  • Chang, Tae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.175-181
    • /
    • 2000
  • 월성원자력4호기가 '99.06.09일 11:53분 경 전출력 소외전원상실시험시 주발전기 병입차단기 및 기동용변압기 차단기의 트립과 동시에 예상 밖의 13.8Kv 원자로 냉각재펌프모터#3(9.000HP)이 순시과전류 보호계전기(50Y) 동작으로 트립되어 이로 인한 냉각재 저유량으로 원자로 제1정지계통이 동작되고 원자로가 비상정지 되어 동 시험이 실패되었음. 이 비정상적인 고장은 예비디젤발전기의 수동 기동 병입과 터빈 수동 정지 및 주발전기 트립후 적절한 조치로 소내전원은 정상적으로 복구되었음. 이에 대해 냉각재펌프모터#3의 순시과전류 동작 원인을 유도전동기의 전원상실 후 발생되는 잔류전압(Residual Voltage)과 공급 모선전압(Bus Voltage) 측면에서 분석하며, 모터의 회전속도, 위상각, 잔류전압크기 변화 및 신속개방 절체시 냉각재펌프모터의 돌입 기동전류를 계산하고, PSS/E 프로그램을 사용한 간략한 모의 사례로 검증하였으며 이에 대한 재발방지를 위한 대책을 제시함.

  • PDF

기기냉각수 최저온도와 정지냉각계통 유량조절밸브 개도에 관한 설계분석

  • 김도현;이중섭;오종필;오광석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.444-449
    • /
    • 1995
  • 한국형 표준 원자력발전소의 정지냉각운전시 최대냉각율은 75$^{\circ}$F/hr(41.7$^{\circ}C$/hr)로 기술사양서에 규정되어 있다. 정지냉각운전 냉각율에 가장 큰 영향을 미치는 2가지 중요한 변수는 정지냉각계통 열교환기를 지나는 원자로냉각재 유량과 기기냉각수의 온도다. 이중 열교환기를 지나는 원자로냉각재 유량은 butterfly형 정지냉각계통 유량조절밸브의 개도에 의하여 조절되는데 개도에 따른 throttle 능력이 중요한 인자다. 또 기기냉각수의 온도는 해수온도의 변화에 따라 편차가 발생하므로 유량조절밸브의 개도와 기기냉각수 온도의 상관관계에 따라 냉각능력이 달라진다. 본 논문에서는 현 울진 3&4호기 정지냉각계통 열 교환기 및 조절밸브 둥의 설비를 기준으로 기술사양서 상의 냉각율 75$^{\circ}$F/hr(41.7$^{\circ}C$/hr) 유지가 가능한 최저 기기냉각수의 온도를 찾아보았고, 아울러 기기냉각수의 온도와 조절밸브의 개도 사이의 관계를 조사하였다. 그 결과 현재의 울진 3&4호기 조절밸브를 최저개도로 조절할 때 약 57$^{\circ}$F(13.9$^{\circ}C$)의 기기냉각수가 공급되어도 냉각율 제한치를 넘지 않는 것으로 분석되었다. 한편, 최저조절가능 유량이 약 2000 gpm(7570 l/min)일 경우에는 낮은 기기냉각수가 공급될 경우 최대냉각율을 초과하므로 한 train을 정지시키고 한 train만으로 운전할 것을 고려하여야 할 것으로 보인다. 이 경우 최저 약 56.5$^{\circ}$F(13.6$^{\circ}C$)의 기기냉각수가 공급되어야 한다. 본 논문의 분석결과는 향후 기기설계사양서나 운전지침서 등에 반영되어 실제 발전소 설계 및 운전절차 수립에 기여할 수 있을 것으로 생각된다.공감대의 형성이 요구된다. 질적 측면에서는 공원 녹지의 기능성의 회복이라는 측면과 시대에 부합되는 새로운 기능 및 가치의 부여가 필요하며, 이를 위해서는 공원의 매력, 공원의 시설기능 증진, 녹지의 질의 향상 및 녹지 가치의 증진에 대한 다양한 시책이 요구된다. 구성적 측면에서는 공원녹지의 개별적 존재보다는 공원 녹지를 상호간 유기적인 계통을 확보하여 공원 녹지의 네트워크를 형성하여 도시 속의 산재된 고립된 섬으로서의 공원 녹지가 아닌 시민생활에 늘 가까이 있는 생활 속의 공원녹지로 재편되어야 한다. 이러한 정책의 의제는 양적 측면에서 보전(CONSERVATION)과 창출(CREATION), 질적 측면에서 쇄신(RENOVATION)과 복구(RESTORATION), 그리고 구성적 측면에서 공원 녹지의 연결(CONNECTION)과 시민 참여에 의한 운동(MOVEMENT)이라는 정책 개념의 구현을 통해 가능하다. 이러한 정책 개념과 의제를 가지고 서울시 공원 녹지 정책을 구체화시키기 위해서 푸르름의 새로운 탄생이라는 기치 아래 풍요로운 서울, 사랑 받는 공원, 생활 속의 녹지의 3대 목표, 공원 녹지의 보전, 잠재 공원 녹지의 창출, 공원의 활성화, 녹지의 복구, 경관 보전 및 복구, 공원 녹지의 네트워크, 도시 녹화의 7대 과제를 설정하고 미시설 공원 녹지 집행, 개발 사업시 공원 녹지의 확보, 환경 녹지의 총량 보호 관리, 도시 소공원 개발, 역사 문화 공원 조성, 하천 공간 복원, 공원 시설 기능 개선, 이용 프로그램 개발, 공원 관리 개선, 환경 피해 녹지의 회복, 도시 환경 림 조성, 녹지 기능 증진, 도시 자연 경관 보전, 공원 녹지체계 구성, 공원 녹지 공급 균형, 주변 환경 녹화, 가로 녹화의 17개 시책을 제안하였다. 이러한 정책사업의 원활한 추진을 위해서는 기존의 관주도의 일방적인 공원 녹지 행정이 아닌 시민의 참여를 통한 시민이 함께 하는 정 책 사업의 추진이 요구되며, 특히 민간 부문의

  • PDF

Reliability Evaluation of Reactor Coolant Pump Trip Signal Redundancy (원자로냉각재펌프 정지신호 다중화 변경에 대한 신뢰도평가)

  • Lee, Eun-Chan;Chi, Moon-Goo;Bae, Yeon-Kyoung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1760-1761
    • /
    • 2011
  • 원자력발전기술원은 발전정지 관련계통 제어케비넷 내에 장착된 제어용 기기들의 다중화 설계변경 활동을 지원하고 관련 기기의 배선상태 등의 육안점검을 통해 취약성 여부를 최종 확인하기 위하여 국내 Westinghouse형 원전 계측제어 케비넷 점검을 수행하였다. 또한 관련 설계변경에 대한 신뢰도평가 기술지원도 함께 수행하여 해당 설계변경이 설비의 신뢰도 향상에 효과가 있는지를 정량적으로 평가하고자 하였다. 이에 따라 원자로냉각재펌프(RCP, Reactor Coolant Pump) 제어 채널의 다중화 개선에 대하여 설계변경 전후의 기기 배열 변화에 따른 계통 신뢰도 변화를 대표유형 기기의 고장률에 근거하여 분석하였다. 고장수목을 이용하여 설계변경 전후의 RCP 고장정지로 인한 발전정지를 유발하는 고장조합을 도출하고, 고장정지 확률 변화를 정량화 하였다. 또한 기기 보호 측면에서 펌프 보호를 위한 신호를 출력하지 못하는 경우를 정량화하여 이를 비교하였다.